Where Used List (Function Module) for SAP ABAP View ITOB (PM technical objects (EQUI, funcational location))
SAP ABAP View
ITOB (PM technical objects (EQUI, funcational location)) is used by
# | Object Type | Object Name | Object Description | Package | Structure Package | Software Component |
---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |
||
1 | ![]() |
/CUM/CUINST_CHECK
|
CU: check CUI (hierarchy, TO, BOM, Quantity, CU data) | ![]() |
![]() |
![]() |
2 | ![]() |
/ISDFPS/FLUPS_FL_CHANGE REFERENCE(IS_ITOB_OLD) TYPE ITOB
|
DFPS: Verteilung von Technischen Plätzen | ![]() |
![]() |
![]() |
3 | ![]() |
/ISDFPS/FLUPS_FL_CHANGE
|
DFPS: Verteilung von Technischen Plätzen | ![]() |
![]() |
![]() |
4 | ![]() |
/ISDFPS/FLUPS_FL_CHANGE REFERENCE(PS_ITOB_NEW) TYPE ITOB
|
DFPS: Verteilung von Technischen Plätzen | ![]() |
![]() |
![]() |
5 | ![]() |
/ISDFPS/FLUPS_FL_CREATE REFERENCE(PS_ITOB) TYPE ITOB
|
DFPS: Verteilung von Technischen Plätzen | ![]() |
![]() |
![]() |
6 | ![]() |
/ISDFPS/FLUPS_FL_CREATE
|
DFPS: Verteilung von Technischen Plätzen | ![]() |
![]() |
![]() |
7 | ![]() |
/ISDFPS/FLUPS_FL_GETDETAIL
|
BAPI -> IDoc: /ISDFPS/ALE_FL_MAINTAIN | ![]() |
![]() |
![]() |
8 | ![]() |
/ISDFPS/FLUPS_FL_GETDETAIL REFERENCE(ES_ITOB) TYPE ITOB
|
BAPI -> IDoc: /ISDFPS/ALE_FL_MAINTAIN | ![]() |
![]() |
![]() |
9 | ![]() |
/ISDFPS/FLUPS_MAINTAIN
|
DFPS Verteilung von Technischen Plätzen | ![]() |
![]() |
![]() |
10 | ![]() |
/ISDFPS/FLUPS_MASTER_IDOC_CREA
|
Verteilung Technische Plätze - IDOC aufbauen | ![]() |
![]() |
![]() |
11 | ![]() |
/ISDFPS/FLUPS_STATUS_UPDATE REFERENCE(I_TPLNR) TYPE ITOB-TPLNR
|
/ISDFPS/ Verteilung - Bearbeiten Status Technischer Platz | ![]() |
![]() |
![]() |
12 | ![]() |
/ISDFPS/FLUPS_STATUS_UPDATE REFERENCE(I_OBJNR) TYPE ITOB-OBJNR
|
/ISDFPS/ Verteilung - Bearbeiten Status Technischer Platz | ![]() |
![]() |
![]() |
13 | ![]() |
/ISDFPS/FLUPS_TEXTS_UPDATE REFERENCE(I_TPLNR) TYPE ITOB-TPLNR
|
/ISDFPS/ Verteilung - Bearbeiten Texte Technischer Platz | ![]() |
![]() |
![]() |
14 | ![]() |
/ISDFPS/LM_READ_FORCE_BY_WK_LG REFERENCE(I_WERK) LIKE ITOB-WERK
|
Ermitteln des Strukturelements eines Equipments | ![]() |
![]() |
![]() |
15 | ![]() |
/ISDFPS/LM_READ_FORCE_BY_WK_LG REFERENCE(I_LGORT) TYPE ITOB-LAGER
|
Ermitteln des Strukturelements eines Equipments | ![]() |
![]() |
![]() |
16 | ![]() |
/ISDFPS/PM_INST_DISM_EQUI REFERENCE(I_SERNR) TYPE ITOB-SERNR OPTIONAL
|
Equipment Ein-/Ausbau | ![]() |
![]() |
![]() |
17 | ![]() |
/ISDFPS/PM_INST_DISM_EQUI
|
Equipment Ein-/Ausbau | ![]() |
![]() |
![]() |
18 | ![]() |
AAPM_AA_DETERMINE_ACTION VALUE(ES_ITOB_FROM_EQUI) TYPE ITOB
|
AA->PM: Ermitteln Synchronisationsaktion für Equi | ![]() |
![]() |
![]() |
19 | ![]() |
AAPM_AA_DETERMINE_ACTION
|
AA->PM: Ermitteln Synchronisationsaktion für Equi | ![]() |
![]() |
![]() |
20 | ![]() |
AAPM_AA_DETERMINE_ACTION VALUE(ES_ITOB) LIKE ITOB
|
AA->PM: Ermitteln Synchronisationsaktion für Equi | ![]() |
![]() |
![]() |
21 | ![]() |
AAPM_AA_PROCESS_EQUI VALUE(I_ITOB_OLD) TYPE ITOB OPTIONAL
|
AA->PM: Bearbeiten zu synchronisierendes Equi | ![]() |
![]() |
![]() |
22 | ![]() |
AAPM_AA_PROCESS_EQUI VALUE(C_ITOB_REC) LIKE ITOB
|
AA->PM: Bearbeiten zu synchronisierendes Equi | ![]() |
![]() |
![]() |
23 | ![]() |
AAPM_AA_PROCESS_EQUI
|
AA->PM: Bearbeiten zu synchronisierendes Equi | ![]() |
![]() |
![]() |
24 | ![]() |
AAPM_AA_READ_DATA_FROM_ASSET REFERENCE(ES_ITOB) TYPE ITOB
|
Erzeugen der SAAPM2 aus ANLA/Z/U/V | ![]() |
![]() |
![]() |
25 | ![]() |
AAPM_AA_READ_DATA_FROM_ASSET
|
Erzeugen der SAAPM2 aus ANLA/Z/U/V | ![]() |
![]() |
![]() |
26 | ![]() |
AAPM_AA_READ_EQUIS_OF_ASSET
|
Statisches Lesen aller einer Anlage zugeordneten Equis | ![]() |
![]() |
![]() |
27 | ![]() |
AAPM_AA_READ_EQUIS_OF_ASSET ET_ITOB STRUCTURE ITOB
|
Statisches Lesen aller einer Anlage zugeordneten Equis | ![]() |
![]() |
![]() |
28 | ![]() |
AAPM_AA_SYNCHRONIZE
|
AA->PM: Synchronisationslogik Anlage->Equipment | ![]() |
![]() |
![]() |
29 | ![]() |
AAPM_AA_SYNC_BY_WORKFLOW VALUE(I_EQUNR) LIKE ITOB-EQUNR
|
AA->PM: Via Workflow ausgelöste Synchronisation Anlage->Equipment | ![]() |
![]() |
![]() |
30 | ![]() |
AAPM_PM_DETERMINE_ACTION
|
PM->AA: Ermitteln Synchronisationsaktion für Anlage | ![]() |
![]() |
![]() |
31 | ![]() |
AAPM_PM_DETERMINE_ACTION VALUE(I_ITOB_OLD) LIKE ITOB OPTIONAL
|
PM->AA: Ermitteln Synchronisationsaktion für Anlage | ![]() |
![]() |
![]() |
32 | ![]() |
AAPM_PM_DETERMINE_ACTION VALUE(I_ITOB_REC) LIKE ITOB
|
PM->AA: Ermitteln Synchronisationsaktion für Anlage | ![]() |
![]() |
![]() |
33 | ![]() |
AAPM_PM_DETERMINE_SYNCDATA
|
PM->AA: Ermitteln Synchronisationsbedarf für Anlage | ![]() |
![]() |
![]() |
34 | ![]() |
AAPM_PM_DETERMINE_SYNCDATA VALUE(I_ITOB_REC) LIKE ITOB
|
PM->AA: Ermitteln Synchronisationsbedarf für Anlage | ![]() |
![]() |
![]() |
35 | ![]() |
AAPM_PM_INTERPRETE_ANKAZ
|
PM->AA: Ermitteln Anlagenklasse aus Equipmenttyp und /oder Equipmentart | ![]() |
![]() |
![]() |
36 | ![]() |
AAPM_PM_INTERPRETE_ANKAZ VALUE(I_ITOB_REC) LIKE ITOB
|
PM->AA: Ermitteln Anlagenklasse aus Equipmenttyp und /oder Equipmentart | ![]() |
![]() |
![]() |
37 | ![]() |
AAPM_PM_PROCESS_ASSET VALUE(I_ITOB_REC) TYPE ITOB OPTIONAL
|
PM->AA: Bearbeiten zu synchronisierende Anlage | ![]() |
![]() |
![]() |
38 | ![]() |
AAPM_PM_PROCESS_ASSET
|
PM->AA: Bearbeiten zu synchronisierende Anlage | ![]() |
![]() |
![]() |
39 | ![]() |
AAPM_PM_SYNCHRONIZE VALUE(C_ITOB_OLD) LIKE ITOB OPTIONAL
|
PM->AA: Synchronisationslogik Equipment->Anlage | ![]() |
![]() |
![]() |
40 | ![]() |
AAPM_PM_SYNCHRONIZE VALUE(I_READ_EQUNR) TYPE ITOB-EQUNR OPTIONAL
|
PM->AA: Synchronisationslogik Equipment->Anlage | ![]() |
![]() |
![]() |
41 | ![]() |
AAPM_PM_SYNCHRONIZE VALUE(C_ITOB_REC) LIKE ITOB OPTIONAL
|
PM->AA: Synchronisationslogik Equipment->Anlage | ![]() |
![]() |
![]() |
42 | ![]() |
AAPM_PM_SYNCHRONIZE
|
PM->AA: Synchronisationslogik Equipment->Anlage | ![]() |
![]() |
![]() |
43 | ![]() |
AAPM_PM_SYNC_BY_WORKFLOW VALUE(I_BUKRS) LIKE ITOB-BUKRS OPTIONAL
|
PM->AA: Via Workflow ausgelöste Synchronisation Equipment->Anlage | ![]() |
![]() |
![]() |
44 | ![]() |
AAPM_PM_SYNC_BY_WORKFLOW VALUE(I_ANLUN) LIKE ITOB-ANLUN OPTIONAL
|
PM->AA: Via Workflow ausgelöste Synchronisation Equipment->Anlage | ![]() |
![]() |
![]() |
45 | ![]() |
AAPM_PM_SYNC_BY_WORKFLOW VALUE(I_ANLNR) LIKE ITOB-ANLNR OPTIONAL
|
PM->AA: Via Workflow ausgelöste Synchronisation Equipment->Anlage | ![]() |
![]() |
![]() |
46 | ![]() |
AAPM_PM_SYNC_BY_WORKFLOW
|
PM->AA: Via Workflow ausgelöste Synchronisation Equipment->Anlage | ![]() |
![]() |
![]() |
47 | ![]() |
AAPM_PM_SYNC_BY_WORKFLOW VALUE(I_EQUNR) LIKE ITOB-EQUNR
|
PM->AA: Via Workflow ausgelöste Synchronisation Equipment->Anlage | ![]() |
![]() |
![]() |
48 | ![]() |
AISA_AAPM_WF_EVENT_POST REFERENCE(ID_EQUNR) TYPE ITOB-EQUNR
|
Posten eines WF Events der AAPM Integration | ![]() |
![]() |
![]() |
49 | ![]() |
ALM_MEREP_070_GETDETAIL
|
Technikerbestand eines Materials/Equipments | ![]() |
![]() |
![]() |
50 | ![]() |
ALM_ME_031_CREATE
|
ALM_ME_031_CREATE | ![]() |
![]() |
![]() |
51 | ![]() |
ALM_ME_ADDR_TECH_CHANGE
|
ALM_ME_ADDR_TECH_CHANGE | ![]() |
![]() |
![]() |
52 | ![]() |
ALM_ME_EQUIPMENT_CHANGE
|
Change equipment | ![]() |
![]() |
![]() |
53 | ![]() |
ALM_ME_EQUIPMENT_GETDETAIL
|
Equipment detail data | ![]() |
![]() |
![]() |
54 | ![]() |
ALM_ME_EQUI_HEADER VALUE(E_OBJECTNUMBER) TYPE ITOB-OBJNR
|
Kopfdaten technischer Platz | ![]() |
![]() |
![]() |
55 | ![]() |
ALM_ME_EQUI_HEADER
|
Kopfdaten technischer Platz | ![]() |
![]() |
![]() |
56 | ![]() |
ALM_ME_EQUI_USTATUS_CHANGE
|
Ändern des Anwenderstatus | ![]() |
![]() |
![]() |
57 | ![]() |
ALM_ME_FLOC_USTATUS_CHANGE
|
ALM_ME_FLOC_USTATUS_CHANGE | ![]() |
![]() |
![]() |
58 | ![]() |
ALM_ME_FUNCLOC_CHANGE
|
Änderungen am Technischen Objekt | ![]() |
![]() |
![]() |
59 | ![]() |
ALM_ME_FUNCLOC_GETDETAIL
|
Detail Data for Functional Location | ![]() |
![]() |
![]() |
60 | ![]() |
ALM_ME_FUNCLOC_HEADER
|
Kopfdaten technischer Platz | ![]() |
![]() |
![]() |
61 | ![]() |
ALM_ME_FUNCLOC_HEADER VALUE(E_OBJECTNUMBER) TYPE ITOB-OBJNR
|
Kopfdaten technischer Platz | ![]() |
![]() |
![]() |
62 | ![]() |
ALM_ME_MEAS_PTS_PARTNERS_COPY
|
A FM to copy measurement points and partners | ![]() |
![]() |
![]() |
63 | ![]() |
ALM_ME_ORDER_CREATE
|
Anlegen PM/CS-Auftrag | ![]() |
![]() |
![]() |
64 | ![]() |
ALM_ME_PARTNER_MAINTAIN REFERENCE(CS_ITOB) TYPE ITOB
|
ALM_ME_PARTNER_MAINTAIN | ![]() |
![]() |
![]() |
65 | ![]() |
ALM_ME_PARTNER_MAINTAIN
|
ALM_ME_PARTNER_MAINTAIN | ![]() |
![]() |
![]() |
66 | ![]() |
ALM_ME_TEC_MOBILE_STAT_CHANGE
|
ALM_ME_TEC_MOBILE_STAT_CHANGE | ![]() |
![]() |
![]() |
67 | ![]() |
ALM_ME_TOB_MEASUREMENT_POINTS VALUE(I_OBJNR) LIKE ITOB-OBJNR
|
Messpunkte / letzte Meßbelege zum technischen Objekt | ![]() |
![]() |
![]() |
68 | ![]() |
ALM_ME_TOB_PARTNERS VALUE(I_OBJNR) TYPE ITOB-OBJNR
|
Partner zum technischen Platz | ![]() |
![]() |
![]() |
69 | ![]() |
ALM_ME_TOB_WARRANTY VALUE(I_OBJNR) LIKE ITOB-OBJNR
|
Garantien zum technischen Objekt | ![]() |
![]() |
![]() |
70 | ![]() |
BAPI_EQUI_CHANGE
|
PM BAPI: Change Equipment | ![]() |
![]() |
![]() |
71 | ![]() |
BAPI_EQUI_CREATE
|
PM BAPI: Create Equipment | ![]() |
![]() |
![]() |
72 | ![]() |
BAPI_EQUI_CREATE_BY_REFERENCE
|
BAPI PM: Anlegen Equipment mit Vorlageequipment | ![]() |
![]() |
![]() |
73 | ![]() |
BAPI_EQUI_DISMANTLE
|
PM BAPI: Install Equipment (Functional Location, Superior Equipment) | ![]() |
![]() |
![]() |
74 | ![]() |
BAPI_EQUI_GETDETAIL
|
PM BAPI: Read Equipment | ![]() |
![]() |
![]() |
75 | ![]() |
BAPI_EQUI_INSTALL
|
PM BAPI: Install Equipment (Functional Location, Superior Equipment) | ![]() |
![]() |
![]() |
76 | ![]() |
BAPI_FUNCLOC_CHANGE
|
PM BAPI: Change Functional Location | ![]() |
![]() |
![]() |
77 | ![]() |
BAPI_FUNCLOC_CREATE
|
PM BAPI: Create Functional Location | ![]() |
![]() |
![]() |
78 | ![]() |
BAPI_FUNCLOC_GETDETAIL
|
PM BAPI: Read Functional Location | ![]() |
![]() |
![]() |
79 | ![]() |
BAPI_FUNCLOC_INHERIT_CHANGE
|
Change Inheritance Indicator of Functional Location | ![]() |
![]() |
![]() |
80 | ![]() |
BAPI_FUNCLOC_STRUC_ASSIGN
|
Assign Superior Functional Location | ![]() |
![]() |
![]() |
81 | ![]() |
BAPI_FUNCLOC_STRUC_REPLACE
|
Assign Superior Functional Location | ![]() |
![]() |
![]() |
82 | ![]() |
BAPI_FUNCLOC_STRUC_UNASSIGN
|
Revoke Assignment to Superior Functional Location | ![]() |
![]() |
![]() |
83 | ![]() |
BAPI_IE4N_BOM_INSTALL
|
Installation of Equipment BOM Item with Goods Movemement, Notif., and CCM | ![]() |
![]() |
![]() |
84 | ![]() |
BAPI_IE4N_BOM_REMOVE
|
Dismantling of Equipment BOM Item with Goods Movemement, Notif., and CCM | ![]() |
![]() |
![]() |
85 | ![]() |
BAPI_IE4N_DISMANTLE
|
Equipment Dismantling with Goods Movement, Notification, and CCM | ![]() |
![]() |
![]() |
86 | ![]() |
BAPI_IE4N_EXCHANGE
|
Exchange of Two Pieces of Equipment | ![]() |
![]() |
![]() |
87 | ![]() |
BAPI_IE4N_INSTALL
|
Equipment Installation with Goods Movement, Notification, and CCM | ![]() |
![]() |
![]() |
88 | ![]() |
CALL_EXIT_SAPLITO0_005
|
Calls customer exit for checking fleet ID data | ![]() |
![]() |
![]() |
89 | ![]() |
CALL_EXIT_SAPLITO0_005 REFERENCE(I_DATA_ITOB) LIKE ITOB
|
Calls customer exit for checking fleet ID data | ![]() |
![]() |
![]() |
90 | ![]() |
CCM09_EQUI_FIND_SUBEQUI
|
CCM : Find any child equis for an equipment | ![]() |
![]() |
![]() |
91 | ![]() |
CCM09_EQUI_FIND_SUBHOLE
|
CCM : Find any Holes in an (parent) equipment | ![]() |
![]() |
![]() |
92 | ![]() |
CCM09_EQUI_FIND_TOPOBJECT
|
CCM : Read TOP Object for Equipment | ![]() |
![]() |
![]() |
93 | ![]() |
CCM09_EQUI_READ
|
CCM : Read EQUI from DB | ![]() |
![]() |
![]() |
94 | ![]() |
CCM09_EQUI_READ REFERENCE(CS_ITOB) TYPE ITOB
|
CCM : Read EQUI from DB | ![]() |
![]() |
![]() |
95 | ![]() |
CCM09_FLOC_FIND_SUBFLOC
|
CCM : Find any child Flocs for an functional location | ![]() |
![]() |
![]() |
96 | ![]() |
CCM09_FLOC_FIND_SUBHOLE
|
CCM : Find any Holes in an (parent) functional location | ![]() |
![]() |
![]() |
97 | ![]() |
CCM09_FLOC_FIND_TOPOBJECT
|
CCM : Read TOP Object for Equipment | ![]() |
![]() |
![]() |
98 | ![]() |
CCM09_FLOC_READ REFERENCE(CS_ITOB) TYPE ITOB
|
CCM: Read FLOC data | ![]() |
![]() |
![]() |
99 | ![]() |
CCM09_FLOC_READ
|
CCM: Read FLOC data | ![]() |
![]() |
![]() |
100 | ![]() |
CCMEQ_SET_FCODE
|
Setzen von Funktionscodes für Table Control | ![]() |
![]() |
![]() |
101 | ![]() |
CCMEQ_SET_FCODE REFERENCE(E_ITOB) TYPE ITOB
|
Setzen von Funktionscodes für Table Control | ![]() |
![]() |
![]() |
102 | ![]() |
CCM_CFG_BOMITEM_AREA_BATCH
|
Display BOM Item Details from Background Job Log | ![]() |
![]() |
![]() |
103 | ![]() |
CCM_CFG_BOMITEM_AREA_IMPORT
|
ConfigMgmt hole screen data import | ![]() |
![]() |
![]() |
104 | ![]() |
CCM_CFG_EQUI_AREA_BATCH
|
Display Equipment Details from Background Job Log | ![]() |
![]() |
![]() |
105 | ![]() |
CCM_CFG_EQUI_AREA_EXPORT
|
ConfigMgmt equi screen data export | ![]() |
![]() |
![]() |
106 | ![]() |
CCM_CFG_EQUI_AREA_IMPORT
|
ConfigMgmt equi screen data import | ![]() |
![]() |
![]() |
107 | ![]() |
CCM_CFG_FLOC_AREA_IMPORT
|
ConfigMgmt floc screen data import | ![]() |
![]() |
![]() |
108 | ![]() |
CCM_CFG_HOLE_AREA_BATCH
|
Display Structure Gap Details from Background Job Log | ![]() |
![]() |
![]() |
109 | ![]() |
CCM_CFG_HOLE_AREA_IMPORT
|
ConfigMgmt hole screen data import | ![]() |
![]() |
![]() |
110 | ![]() |
CRM_ADDRESS_CHANGE_OS REFERENCE(CS_ITOB) TYPE ITOB
|
Ändern Adresse des Equipment durch den Upload | ![]() |
![]() |
![]() |
111 | ![]() |
CRM_ADDRESS_CHANGE_OS
|
Ändern Adresse des Equipment durch den Upload | ![]() |
![]() |
![]() |
112 | ![]() |
CRM_EQUI_CFG_SINGLE_CHANGE_OS REFERENCE(CS_ITOB) TYPE ITOB
|
Ändern Konfiguration des Equipment durch den Upload | ![]() |
![]() |
![]() |
113 | ![]() |
CRM_EQUI_CFG_SINGLE_CHANGE_OS
|
Ändern Konfiguration des Equipment durch den Upload | ![]() |
![]() |
![]() |
114 | ![]() |
CRM_EQUI_CFG_SINGLE_CREATE_OS REFERENCE(CS_ITOB) TYPE ITOB
|
Ändern Konfiguration des Equipment durch den Upload | ![]() |
![]() |
![]() |
115 | ![]() |
CRM_EQUI_CFG_SINGLE_CREATE_OS
|
Ändern Konfiguration des Equipment durch den Upload | ![]() |
![]() |
![]() |
116 | ![]() |
CRM_EQUI_STATUS_CHANGE_OS REFERENCE(CS_ITOB) TYPE ITOB
|
Ändern Status des Equipments durch den Upload aus CRM | ![]() |
![]() |
![]() |
117 | ![]() |
CRM_IHPA_CHANGE_OS REFERENCE(CS_ITOB) TYPE ITOB
|
Geschäftpartnersbeziehung ändern | ![]() |
![]() |
![]() |
118 | ![]() |
CRM_IHPA_CHANGE_OS
|
Geschäftpartnersbeziehung ändern | ![]() |
![]() |
![]() |
119 | ![]() |
CRS_EQUIPMENTCU_COLLECT_DATA
|
Delta Download - Equi & serial number configuration | ![]() |
![]() |
![]() |
120 | ![]() |
CRS_PROXY_BAPI_EQUI_CHANGE2_OS
|
BAPI: Ändern Equipment | ![]() |
![]() |
![]() |
121 | ![]() |
DFPS_LM_INT_LBK_MEQ_SET_OKCODE REFERENCE(CS_ITOB) TYPE ITOB
|
OK-Code an Master Equipement Screen übergeben | ![]() |
![]() |
![]() |
122 | ![]() |
DIACL_ITOB_SUBSCR_PAI REFERENCE(CS_ITOB) TYPE ITOB
|
data transfer DIACL_GUI_ITOB -> ITOB | ![]() |
![]() |
![]() |
123 | ![]() |
DIACL_ITOB_SUBSCR_PAI
|
data transfer DIACL_GUI_ITOB -> ITOB | ![]() |
![]() |
![]() |
124 | ![]() |
DIACL_ITOB_SUBSCR_PBO REFERENCE(IS_ITOB) TYPE ITOB
|
data transfer ITOB -> DIACL_GUI_ITOB | ![]() |
![]() |
![]() |
125 | ![]() |
DIACL_ITOB_SUBSCR_PBO
|
data transfer ITOB -> DIACL_GUI_ITOB | ![]() |
![]() |
![]() |
126 | ![]() |
DIACL_ITOB_SUBSCR_PBO REFERENCE(IS_ITOB_OLD) TYPE ITOB
|
data transfer ITOB -> DIACL_GUI_ITOB | ![]() |
![]() |
![]() |
127 | ![]() |
DI_SUBCON_PART_TO_STOCK
|
Stock movement - Part to stock | ![]() |
![]() |
![]() |
128 | ![]() |
DPWTY_SERIAL_NUMBER_EQUI_GET
|
RFC to get the equipment number of a serial number | ![]() |
![]() |
![]() |
129 | ![]() |
EAM_SET_STATUS_FOR_OBJECT
|
Set user status for EAM object | ![]() |
![]() |
![]() |
130 | ![]() |
ECP_SRV_SWITCH_OBJ
|
switch to auth_check for equi or func.loc. | ![]() |
![]() |
![]() |
131 | ![]() |
ECP_SRV_SWITCH_OBJ VALUE(T_ITOB) TYPE ITOB
|
switch to auth_check for equi or func.loc. | ![]() |
![]() |
![]() |
132 | ![]() |
EM_NTF_ORD_CREATE
|
xEM: Meldung / Auftrag im ERP anlegen | ![]() |
![]() |
![]() |
133 | ![]() |
EQUIPMENT_BAPI_GET_DATA
|
Aufbereitung der Equidaten für ALE-Ausgang | ![]() |
![]() |
![]() |
134 | ![]() |
EQUIPMENT_CHECK
|
Lesen Equipment, ob vorhanden Übergabe Kurztext | ![]() |
![]() |
![]() |
135 | ![]() |
EQUIPMENT_CHECK_HISTORY_CHANGE REFERENCE(IS_ITOB_NEW) TYPE ITOB
|
Prüft ob historienrelevante Änderungen durchgeführt werden | ![]() |
![]() |
![]() |
136 | ![]() |
EQUIPMENT_CHECK_HISTORY_CHANGE
|
Prüft ob historienrelevante Änderungen durchgeführt werden | ![]() |
![]() |
![]() |
137 | ![]() |
EQUIPMENT_CHECK_HISTORY_CHANGE REFERENCE(IS_ITOB_OLD) TYPE ITOB
|
Prüft ob historienrelevante Änderungen durchgeführt werden | ![]() |
![]() |
![]() |
138 | ![]() |
EQUIPMENT_CHECK_UPDATE_EFHM
|
Check Update FHM-Segment | ![]() |
![]() |
![]() |
139 | ![]() |
EQUIPMENT_CHECK_UPDATE_EFHM REFERENCE(C_REC_ITOB) LIKE ITOB OPTIONAL
|
Check Update FHM-Segment | ![]() |
![]() |
![]() |
140 | ![]() |
EQUIPMENT_COPY
|
Kopieren eines Equipments über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
141 | ![]() |
EQUIPMENT_COPY REFERENCE(I_REFER_REC) LIKE ITOB
|
Kopieren eines Equipments über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
142 | ![]() |
EQUIPMENT_COPY REFERENCE(E_OBJECT_REC) LIKE ITOB
|
Kopieren eines Equipments über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
143 | ![]() |
EQUIPMENT_ONLY
|
Read EQUI segment of equipment/serial number | ![]() |
![]() |
![]() |
144 | ![]() |
EQUIPMENT_PERMIT_MAINTAIN
|
Genehmigungen zum Equipment pflegen | ![]() |
![]() |
![]() |
145 | ![]() |
EQUIPMENT_READ
|
Read equipment record | ![]() |
![]() |
![]() |
146 | ![]() |
EQUIPMENT_READ_VIEW
|
Read equipment view | ![]() |
![]() |
![]() |
147 | ![]() |
EQUIPMENT_SAVE REFERENCE(C_OBJECT_REC) LIKE ITOB OPTIONAL
|
Verbuchung eines Equipments über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
148 | ![]() |
EQUIPMENT_SAVE
|
Verbuchung eines Equipments über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
149 | ![]() |
EQUIPMENT_SAVE REFERENCE(I_OBJECT_OLD) LIKE ITOB OPTIONAL
|
Verbuchung eines Equipments über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
150 | ![]() |
EQUI_WORKFLOW_SET VALUE(I_ITOB_REC) LIKE ITOB
|
Setzen Workflowereignis | ![]() |
![]() |
![]() |
151 | ![]() |
EQUI_WORKFLOW_SET
|
Setzen Workflowereignis | ![]() |
![]() |
![]() |
152 | ![]() |
EQUI_WORKFLOW_SET VALUE(I_ITOB_OLD) LIKE ITOB OPTIONAL
|
Setzen Workflowereignis | ![]() |
![]() |
![]() |
153 | ![]() |
EXIT_SAPLAAPM_001 VALUE(I_ITOB_REC) LIKE ITOB
|
User Exit for Deriving Asset Class from Fields of Plant Maintenance | ![]() |
![]() |
![]() |
154 | ![]() |
EXIT_SAPLIPW4_001 REFERENCE(IS_ITOB) TYPE ITOB
|
CCM: User Screen (Remove) - Import Data from SAPLCCM06^ | ![]() |
![]() |
![]() |
155 | ![]() |
EXIT_SAPLIPW4_002 REFERENCE(ES_ITOB) TYPE ITOB
|
CCM: User Screen (Remove) - Export Data from SAPLCCM06 | ![]() |
![]() |
![]() |
156 | ![]() |
EXIT_SAPLIPW4_003 REFERENCE(IS_ITOB) TYPE ITOB
|
CCM: User Screen (Install) - Import Data from SAPLCCM06 | ![]() |
![]() |
![]() |
157 | ![]() |
EXIT_SAPLIPW4_004 REFERENCE(ES_ITOB) TYPE ITOB
|
CCM: User Screen (Install) - Export Data from SAPLCCM06 | ![]() |
![]() |
![]() |
158 | ![]() |
EXIT_SAPLIPW4_005 REFERENCE(IS_ITOB) TYPE ITOB
|
CCM: User Screen Message (Remove)- Import Data from SAPLCCM06 | ![]() |
![]() |
![]() |
159 | ![]() |
EXIT_SAPLIPW4_007 REFERENCE(IS_ITOB) TYPE ITOB
|
CCM: User Screen Message (Install) - Import Data from SAPLCCM06 | ![]() |
![]() |
![]() |
160 | ![]() |
EXIT_SAPLITO0_005 REFERENCE(I_DATA_ITOB) LIKE ITOB
|
Customer Exit Fleet Identification Data: Checks | ![]() |
![]() |
![]() |
161 | ![]() |
EXIT_SAPLITOBS_001 REFERENCE(I_REFOBJ_REC) LIKE ITOB
|
Customer Exit Creating With Copy Mmodel: Change Copied Field Contents | ![]() |
![]() |
![]() |
162 | ![]() |
FLEET_GET_CONSUMP_INFO
|
Fleet_consumption_information | ![]() |
![]() |
![]() |
163 | ![]() |
FLEET_GET_CONSUMP_INFO REFERENCE(I_ITOB) LIKE ITOB
|
Fleet_consumption_information | ![]() |
![]() |
![]() |
164 | ![]() |
FUNCLOC_BAPI_GET_DATA
|
Aufbereitung der Equidaten für ALE-Ausgang | ![]() |
![]() |
![]() |
165 | ![]() |
FUNCLOC_PERMIT_MAINTAIN
|
Genehmigungen zum Technischen Platz pflegen | ![]() |
![]() |
![]() |
166 | ![]() |
FUNC_LOCATION_SAVE REFERENCE(I_OBJECT_OLD) LIKE ITOB OPTIONAL
|
Verbuchung eines Technischen Platzes über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
167 | ![]() |
FUNC_LOCATION_SAVE
|
Verbuchung eines Technischen Platzes über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
168 | ![]() |
FUNC_LOCATION_SAVE REFERENCE(C_OBJECT_REC) LIKE ITOB OPTIONAL
|
Verbuchung eines Technischen Platzes über den ITOB-Schreibpuffer | ![]() |
![]() |
![]() |
169 | ![]() |
GHO_MEAS_POINT_CREATE
|
Create measuring point in core table(IMPTT) | ![]() |
![]() |
![]() |
170 | ![]() |
GHO_MP_ID_READ
|
Read Measurement Point Details | ![]() |
![]() |
![]() |
171 | ![]() |
GR_ORDER_SERIAL
|
Mat./Sernr. die zu einem Auftrag WE gebucht sind | ![]() |
![]() |
![]() |
172 | ![]() |
IBOC_DYNPRO_CHECK_SERIALNO REFERENCE(I_UII) TYPE ITOB-UII OPTIONAL
|
IBOC: material+serialno (EQUI) | ![]() |
![]() |
![]() |
173 | ![]() |
IBOC_DYNPRO_CHECK_SERIALNO VALUE(I_SERNO) LIKE ITOB-SERNR
|
IBOC: material+serialno (EQUI) | ![]() |
![]() |
![]() |
174 | ![]() |
IBOC_DYNPRO_CHECK_SERIALNO VALUE(I_MATNO) LIKE ITOB-MATNR
|
IBOC: material+serialno (EQUI) | ![]() |
![]() |
![]() |
175 | ![]() |
IBOC_DYNPRO_CHECK_SERIALNO_BAT VALUE(I_MATNO) LIKE ITOB-MATNR
|
IBOC: batch for serialmaster (EQUI) | ![]() |
![]() |
![]() |
176 | ![]() |
IBOC_DYNPRO_CHECK_SERIALNO_BAT VALUE(I_SERNO) LIKE ITOB-SERNR
|
IBOC: batch for serialmaster (EQUI) | ![]() |
![]() |
![]() |
177 | ![]() |
IBOC_DYNPRO_CHECK_SERIALNO_BAT VALUE(I_BATCH) LIKE ITOB-CHARGE
|
IBOC: batch for serialmaster (EQUI) | ![]() |
![]() |
![]() |
178 | ![]() |
IEQCM_ASSET_UPDATE
|
Arbeitstabellen verbuchen | ![]() |
![]() |
![]() |
179 | ![]() |
IEQCM_EXT_HOLE_AT_INSTALL
|
Bearbeitung Strukturlücken bei Einbau | ![]() |
![]() |
![]() |
180 | ![]() |
IEQM_MASS_CHANGE_EXEC
|
Mass Change for Equipments | ![]() |
![]() |
![]() |
181 | ![]() |
IEQM_USTATUS_CHANGE
|
Change user status | ![]() |
![]() |
![]() |
182 | ![]() |
ILOM_MASS_CHANGE_EXEC
|
Massenpflege: Online und Batch | ![]() |
![]() |
![]() |
183 | ![]() |
IQS0_CREATE_OBJECT
|
Anlegen Technisches Objekt (z.B. aus Bezugsobjekt-Screen) | ![]() |
![]() |
![]() |
184 | ![]() |
IQS0_CREATE_OBJECT VALUE(CS_ITOB) TYPE ITOB
|
Anlegen Technisches Objekt (z.B. aus Bezugsobjekt-Screen) | ![]() |
![]() |
![]() |
185 | ![]() |
ISU_CHANGE_CONNOBJ
|
Ändern des Anschlussobjekts im Geräteplatz | ![]() |
![]() |
![]() |
186 | ![]() |
ISU_DB_EEWA_PROP_H_UPDATE VALUE(X_OLD_ITOB) TYPE ITOB OPTIONAL
|
INTERN: Update von ewa_prop_h | ![]() |
![]() |
![]() |
187 | ![]() |
ISU_DB_EEWA_PROP_H_UPDATE
|
INTERN: Update von ewa_prop_h | ![]() |
![]() |
![]() |
188 | ![]() |
ISU_DB_EEWA_PROP_UPDATE_ALL VALUE(X_OLD_ITOB) TYPE ITOB OPTIONAL
|
INTERN: Update von eewa_prop | ![]() |
![]() |
![]() |
189 | ![]() |
ISU_DB_EEWA_PROP_UPDATE_ALL
|
INTERN: Update von eewa_prop | ![]() |
![]() |
![]() |
190 | ![]() |
ISU_DB_EGPL_SINGLE
|
INTERNAL: reads a device location | ![]() |
![]() |
![]() |
191 | ![]() |
ISU_DB_EGPL_UPDATE
|
INTERN: Datenbank-Update für Tabelle EGPL | ![]() |
![]() |
![]() |
192 | ![]() |
ISU_DB_EGPL_UPDATE REFERENCE(X_OLD_ITOB) TYPE ITOB
|
INTERN: Datenbank-Update für Tabelle EGPL | ![]() |
![]() |
![]() |
193 | ![]() |
ISU_DB_EHAU_SINGLE
|
INTERN: Liest ein Anschlußobjekt | ![]() |
![]() |
![]() |
194 | ![]() |
ISU_DB_EHAU_UPDATE VALUE(X_OLD_ITOB) TYPE ITOB OPTIONAL
|
INTERN: Update eines Anschlußobjekts (incl. technischer Platz) | ![]() |
![]() |
![]() |
195 | ![]() |
ISU_DB_EHAU_UPDATE
|
INTERN: Update eines Anschlußobjekts (incl. technischer Platz) | ![]() |
![]() |
![]() |
196 | ![]() |
ISU_DB_EWAA_PROP_H_SINGLE
|
INTERN: Lesen von eewa_prop_h (Direktzugriff) | ![]() |
![]() |
![]() |
197 | ![]() |
ISU_EQUIPMENT_UPDATE_PM
|
Einbau/Ausbau der ISU-Equipments im PM durchführen | ![]() |
![]() |
![]() |
198 | ![]() |
ISU_FUNCLOC_CLASSIFICATION
|
Klassifizierung | ![]() |
![]() |
![]() |
199 | ![]() |
ISU_IDOC_INPUT_ISU_SDSM_COMP
|
INTERN: IS-U Inbound für Idoc ISU_SDSM_ORDER | ![]() |
![]() |
![]() |
200 | ![]() |
ISU_M_FUNCLOC_CHANGE VALUE(Y_TPLNR) LIKE ITOB-TPLNR
|
IS-U Mig: Ändern eines technischen Platzes | ![]() |
![]() |
![]() |
201 | ![]() |
ISU_M_FUNCLOC_CHANGE
|
IS-U Mig: Ändern eines technischen Platzes | ![]() |
![]() |
![]() |
202 | ![]() |
ISU_M_FUNCLOC_CREATE
|
IS-U Mig: Anlegen technischer Platz | ![]() |
![]() |
![]() |
203 | ![]() |
ISU_M_FUNCLOC_CREATE VALUE(Y_TPLNR) LIKE ITOB-TPLNR
|
IS-U Mig: Anlegen technischer Platz | ![]() |
![]() |
![]() |
204 | ![]() |
ITO3_EQUIPMENT_READ_STATUS VALUE(I_STAT_OBJNR) LIKE ITOB-OBJNR OPTIONAL
|
ITOB Status RFC: Lesen Status eines Equipments | ![]() |
![]() |
![]() |
205 | ![]() |
ITO3_EQUIPMENT_READ_STATUS VALUE(I_EQUNR) LIKE ITOB-EQUNR
|
ITOB Status RFC: Lesen Status eines Equipments | ![]() |
![]() |
![]() |
206 | ![]() |
ITO3_EQUIPMENT_READ_STATUS
|
ITOB Status RFC: Lesen Status eines Equipments | ![]() |
![]() |
![]() |
207 | ![]() |
ITO3_FUNCLOC_READ_STATUS VALUE(I_STAT_OBJNR) LIKE ITOB-OBJNR OPTIONAL
|
ITOB Status RFC: Lesen Status eines Techn. Platzes | ![]() |
![]() |
![]() |
208 | ![]() |
ITO3_FUNCLOC_READ_STATUS
|
ITOB Status RFC: Lesen Status eines Techn. Platzes | ![]() |
![]() |
![]() |
209 | ![]() |
ITO3_OBJECT_READ_ADDRESS_GEOL
|
Adresse und Geolokation für Technisches Objekt lesen | ![]() |
![]() |
![]() |
210 | ![]() |
ITO3_OBJECT_READ_ADDRESS_GEOL REFERENCE(IV_ADRNR) TYPE ITOB-ADRNR OPTIONAL
|
Adresse und Geolokation für Technisches Objekt lesen | ![]() |
![]() |
![]() |
211 | ![]() |
ITO3_OBJECT_READ_STATUS
|
ITOB Status API: Lesen Status Technischer Objekte | ![]() |
![]() |
![]() |
212 | ![]() |
ITOB_BUF_EQ_CHECK_LOCKS
|
ITOB: Sperrprüfung Equipment/Serialnummer | ![]() |
![]() |
![]() |
213 | ![]() |
ITOB_BUF_SN_ADMIN
|
ITOB: Puffer: Serialnummernverwaltung | ![]() |
![]() |
![]() |
214 | ![]() |
ITOB_CALL_BADI
|
ITOB: Aufruf von BADI-Bausteinen | ![]() |
![]() |
![]() |
215 | ![]() |
ITOB_CALL_BADI VALUE(I_ITOB_REC) LIKE ITOB
|
ITOB: Aufruf von BADI-Bausteinen | ![]() |
![]() |
![]() |
216 | ![]() |
ITOB_CHECK_ALL
|
Prüfung sämtlicher ITOB-Daten | ![]() |
![]() |
![]() |
217 | ![]() |
ITOB_CHECK_ALL VALUE(I_ITOB_OLD_REC) LIKE ITOB OPTIONAL
|
Prüfung sämtlicher ITOB-Daten | ![]() |
![]() |
![]() |
218 | ![]() |
ITOB_CHECK_ALL VALUE(I_ITOB_REC) LIKE ITOB
|
Prüfung sämtlicher ITOB-Daten | ![]() |
![]() |
![]() |
219 | ![]() |
ITOB_CHECK_ALL VALUE(E_ITOB_REC) LIKE ITOB
|
Prüfung sämtlicher ITOB-Daten | ![]() |
![]() |
![]() |
220 | ![]() |
ITOB_CHECK_AUTHORITY REFERENCE(I_ITOB_REC) LIKE ITOB
|
Prüfung transaktions- und feldbezogener Berechtigung | ![]() |
![]() |
![]() |
221 | ![]() |
ITOB_CHECK_AUTHORITY
|
Prüfung transaktions- und feldbezogener Berechtigung | ![]() |
![]() |
![]() |
222 | ![]() |
ITOB_CHECK_CATALOG_PROFILE VALUE(RBNR) LIKE ITOB-RBNR
|
L1: Berichtsschema | ![]() |
![]() |
![]() |
223 | ![]() |
ITOB_CHECK_CHANGE_MATNR_SERNR REFERENCE(I_SERNR) TYPE ITOB-SERNR
|
Prüfungen Änderung Matnr/Sernr Equipment | ![]() |
![]() |
![]() |
224 | ![]() |
ITOB_CHECK_CHANGE_MATNR_SERNR REFERENCE(I_SUBMT) TYPE ITOB-SUBMT
|
Prüfungen Änderung Matnr/Sernr Equipment | ![]() |
![]() |
![]() |
225 | ![]() |
ITOB_CHECK_CHANGE_MATNR_SERNR
|
Prüfungen Änderung Matnr/Sernr Equipment | ![]() |
![]() |
![]() |
226 | ![]() |
ITOB_CHECK_CONFIG_CTL REFERENCE(C_OBJECT_REC) TYPE ITOB
|
Check configuration control fields for equipment | ![]() |
![]() |
![]() |
227 | ![]() |
ITOB_CHECK_CONFIG_CTL
|
Check configuration control fields for equipment | ![]() |
![]() |
![]() |
228 | ![]() |
ITOB_CHECK_CONFIG_CTL REFERENCE(I_OBJECT_OLD) TYPE ITOB OPTIONAL
|
Check configuration control fields for equipment | ![]() |
![]() |
![]() |
229 | ![]() |
ITOB_CHECK_CUSTOMER VALUE(KUNDE) LIKE ITOB-KUND1
|
L1: Kunde | ![]() |
![]() |
![]() |
230 | ![]() |
ITOB_CHECK_DATLWB VALUE(DATLWB) LIKE ITOB-DATLWB
|
Prüfung Datum der letzten Warenbewegung | ![]() |
![]() |
![]() |
231 | ![]() |
ITOB_CHECK_EQBS
|
Prüfen der Bestandsinformationen | ![]() |
![]() |
![]() |
232 | ![]() |
ITOB_CHECK_EQBS REFERENCE(IS_ITOB_OLD) TYPE ITOB
|
Prüfen der Bestandsinformationen | ![]() |
![]() |
![]() |
233 | ![]() |
ITOB_CHECK_EQBS REFERENCE(CS_ITOB_NEW) TYPE ITOB
|
Prüfen der Bestandsinformationen | ![]() |
![]() |
![]() |
234 | ![]() |
ITOB_CHECK_EQUITYPE VALUE(EQART_IMP) LIKE ITOB-EQART
|
L1: Objektart | ![]() |
![]() |
![]() |
235 | ![]() |
ITOB_CHECK_FLEET_ALL
|
Prüfung sämtlicher FLEET-Daten | ![]() |
![]() |
![]() |
236 | ![]() |
ITOB_CHECK_FLEET_ALL VALUE(I_ITOB_REC) LIKE ITOB
|
Prüfung sämtlicher FLEET-Daten | ![]() |
![]() |
![]() |
237 | ![]() |
ITOB_CHECK_FLEET_ALL VALUE(E_ITOB_REC) LIKE ITOB
|
Prüfung sämtlicher FLEET-Daten | ![]() |
![]() |
![]() |
238 | ![]() |
ITOB_CHECK_FLEET_ALL VALUE(I_ITOB_OLD_REC) LIKE ITOB OPTIONAL
|
Prüfung sämtlicher FLEET-Daten | ![]() |
![]() |
![]() |
239 | ![]() |
ITOB_CHECK_FLEET_IDENTITY VALUE(I_ITOB_REC) LIKE ITOB
|
L1: Identifikationsdaten eines Fahrzeugs | ![]() |
![]() |
![]() |
240 | ![]() |
ITOB_CHECK_FLEET_IDENTITY
|
L1: Identifikationsdaten eines Fahrzeugs | ![]() |
![]() |
![]() |
241 | ![]() |
ITOB_CHECK_MATERIAL_BATCH VALUE(BATCH_IMP) LIKE ITOB-CHARGE
|
L2: Erweiterte Chargenprüfung (Stammcharge) | ![]() |
![]() |
![]() |
242 | ![]() |
ITOB_CHECK_MATERIAL_BATCH VALUE(MATNR_IMP) LIKE ITOB-MATNR
|
L2: Erweiterte Chargenprüfung (Stammcharge) | ![]() |
![]() |
![]() |
243 | ![]() |
ITOB_CHECK_MATERIAL_BATCH VALUE(LOCAT_IMP) LIKE ITOB-LAGER
|
L2: Erweiterte Chargenprüfung (Stammcharge) | ![]() |
![]() |
![]() |
244 | ![]() |
ITOB_CHECK_MATERIAL_BATCH VALUE(PLANT_IMP) LIKE ITOB-WERK
|
L2: Erweiterte Chargenprüfung (Stammcharge) | ![]() |
![]() |
![]() |
245 | ![]() |
ITOB_CHECK_MATERIAL_MARA VALUE(MATNR_IMP) LIKE ITOB-MATNR
|
L2: Material A-Segment (MARA-Ebene) | ![]() |
![]() |
![]() |
246 | ![]() |
ITOB_CHECK_MATERIAL_MARC VALUE(PLANT_IMP) LIKE ITOB-WERK
|
L2: Material Werkssegment (MARC-Ebene) | ![]() |
![]() |
![]() |
247 | ![]() |
ITOB_CHECK_MATERIAL_MARC VALUE(MATNR_IMP) LIKE ITOB-MATNR
|
L2: Material Werkssegment (MARC-Ebene) | ![]() |
![]() |
![]() |
248 | ![]() |
ITOB_CHECK_MATERIAL_MBEW VALUE(BATCH_IMP) LIKE ITOB-CHARGE
|
L2: Material Bewertungsartensegment (MBEW-Ebene) | ![]() |
![]() |
![]() |
249 | ![]() |
ITOB_CHECK_MATERIAL_MBEW VALUE(MATNR_IMP) LIKE ITOB-MATNR
|
L2: Material Bewertungsartensegment (MBEW-Ebene) | ![]() |
![]() |
![]() |
250 | ![]() |
ITOB_CHECK_MATERIAL_MBEW VALUE(PLANT_IMP) LIKE ITOB-WERK
|
L2: Material Bewertungsartensegment (MBEW-Ebene) | ![]() |
![]() |
![]() |
251 | ![]() |
ITOB_CHECK_MATERIAL_MCHAR VALUE(BATCH_IMP) LIKE ITOB-CHARGE
|
L2: Material Chargensegment (MCHAR-Ebene) | ![]() |
![]() |
![]() |
252 | ![]() |
ITOB_CHECK_MATERIAL_MCHAR VALUE(LOCAT_IMP) LIKE ITOB-LAGER
|
L2: Material Chargensegment (MCHAR-Ebene) | ![]() |
![]() |
![]() |
253 | ![]() |
ITOB_CHECK_MATERIAL_MCHAR VALUE(MATNR_IMP) LIKE ITOB-MATNR
|
L2: Material Chargensegment (MCHAR-Ebene) | ![]() |
![]() |
![]() |
254 | ![]() |
ITOB_CHECK_MATERIAL_MCHAR VALUE(PLANT_IMP) LIKE ITOB-WERK
|
L2: Material Chargensegment (MCHAR-Ebene) | ![]() |
![]() |
![]() |
255 | ![]() |
ITOB_CHECK_MATERIAL_MINST VALUE(MATNR_IMP) LIKE ITOB-MATNR
|
L2: Material Instandhaltung (z.B. Bautyp) | ![]() |
![]() |
![]() |
256 | ![]() |
ITOB_CHECK_MATERIAL_MINST VALUE(PLANT_IMP) LIKE ITOB-WERK DEFAULT SPACE
|
L2: Material Instandhaltung (z.B. Bautyp) | ![]() |
![]() |
![]() |
257 | ![]() |
ITOB_CHECK_PLANT_MAINT VALUE(SWERK_IMP) LIKE ITOB-SWERK
|
L2: Werk Standort | ![]() |
![]() |
![]() |
258 | ![]() |
ITOB_CHECK_SERIALNO VALUE(MATNR_IMP) LIKE ITOB-MATNR OPTIONAL
|
L1: Serialnummer zum Material | ![]() |
![]() |
![]() |
259 | ![]() |
ITOB_CHECK_SERIALNO VALUE(UII) TYPE ITOB-UII OPTIONAL
|
L1: Serialnummer zum Material | ![]() |
![]() |
![]() |
260 | ![]() |
ITOB_CHECK_SERIALNO VALUE(SERNR_EXP) LIKE ITOB-SERNR
|
L1: Serialnummer zum Material | ![]() |
![]() |
![]() |
261 | ![]() |
ITOB_CHECK_SERIALNO VALUE(SERNR_IMP) LIKE ITOB-SERNR OPTIONAL
|
L1: Serialnummer zum Material | ![]() |
![]() |
![]() |
262 | ![]() |
ITOB_CHECK_UPDATE_FLEET
|
Check Update Flottenobjektsegment (FLEET) | ![]() |
![]() |
![]() |
263 | ![]() |
ITOB_CHECK_UPDATE_FLEET REFERENCE(C_REC_ITOB) LIKE ITOB OPTIONAL
|
Check Update Flottenobjektsegment (FLEET) | ![]() |
![]() |
![]() |
264 | ![]() |
ITOB_CHECK_UPDATE_FLEET REFERENCE(I_OLD_ITOB) LIKE ITOB OPTIONAL
|
Check Update Flottenobjektsegment (FLEET) | ![]() |
![]() |
![]() |
265 | ![]() |
ITOB_CHECK_VENDOR VALUE(ELIEF) LIKE ITOB-ELIEF
|
L1: Lieferant | ![]() |
![]() |
![]() |
266 | ![]() |
ITOB_CHECK_WARRANTY VALUE(MGANR_IMP) LIKE ITOB-MGANR
|
L1: Garantiedaten (Mustergarantie) | ![]() |
![]() |
![]() |
267 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(TPLNR_IMP) LIKE ITOB-TPLNR OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
268 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(EQUNR_IMP) LIKE ITOB-EQUNR OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
269 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(KOSTL_IMP) LIKE ITOB-KOSTL OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
270 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(GSBER_IMP) LIKE ITOB-GSBER OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
271 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(IWERK_IMP) LIKE ITOB-IWERK OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
272 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(BUKRS_IMP) LIKE ITOB-BUKRS OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
273 | ![]() |
ITOB_CHECK_WBSELEMENT VALUE(KOKRS_IMP) LIKE ITOB-KOKRS OPTIONAL
|
L1: PPS-Element | ![]() |
![]() |
![]() |
274 | ![]() |
ITOB_CHECK_WORKCENTER_INT VALUE(OBJID_IMP) LIKE ITOB-WKCTR
|
L1: Arbeitsplatz (über interne Objektnummer) | ![]() |
![]() |
![]() |
275 | ![]() |
ITOB_CONSUMPTION_MPPOS_GET REFERENCE(I_EQUNR) TYPE ITOB-EQUNR
|
Lesen verbrauchsrelevante Zähler | ![]() |
![]() |
![]() |
276 | ![]() |
ITOB_CONSUMPTION_MPPOS_GET REFERENCE(E_ITOB) TYPE ITOB
|
Lesen verbrauchsrelevante Zähler | ![]() |
![]() |
![]() |
277 | ![]() |
ITOB_CONSUMPTION_MPPOS_GET
|
Lesen verbrauchsrelevante Zähler | ![]() |
![]() |
![]() |
278 | ![]() |
ITOB_CONSUMPTION_UPDATE
|
Erfasser verbrauchsrelevanter Zählerstände | ![]() |
![]() |
![]() |
279 | ![]() |
ITOB_CONSUMPTION_UPDATE VALUE(I_EQUNR) TYPE ITOB-EQUNR
|
Erfasser verbrauchsrelevanter Zählerstände | ![]() |
![]() |
![]() |
280 | ![]() |
ITOB_CONSUMPTION_WINDOW REFERENCE(I_EQUNR) TYPE ITOB-EQUNR
|
Anzeigen Verbrauchsinformation | ![]() |
![]() |
![]() |
281 | ![]() |
ITOB_COPY_INIT REFERENCE(C_ITOB_REC) LIKE ITOB OPTIONAL
|
ITOB: Aufbereiten ITOB-Struktur als Kopiervorlage | ![]() |
![]() |
![]() |
282 | ![]() |
ITOB_COPY_INIT
|
ITOB: Aufbereiten ITOB-Struktur als Kopiervorlage | ![]() |
![]() |
![]() |
283 | ![]() |
ITOB_DATA_EXPORT REFERENCE(E_REC_ITOB) LIKE ITOB
|
Data export from ITO0 (e.g. into a calling module pool) | ![]() |
![]() |
![]() |
284 | ![]() |
ITOB_DATA_EXPORT
|
Data export from ITO0 (e.g. into a calling module pool) | ![]() |
![]() |
![]() |
285 | ![]() |
ITOB_DATA_IMPORT
|
Data import into ITO0 (e.g. from a calling module pool) | ![]() |
![]() |
![]() |
286 | ![]() |
ITOB_DATA_INTERNAL_GET
|
Get internal object data | ![]() |
![]() |
![]() |
287 | ![]() |
ITOB_DATA_INTERNAL_SET
|
Set internal object type and data | ![]() |
![]() |
![]() |
288 | ![]() |
ITOB_EQUIPMENT_CREATE_SINGLE
|
ITOB Puffer RFC: Anlegen einzelnes Equipment | ![]() |
![]() |
![]() |
289 | ![]() |
ITOB_EQUIPMENT_CREATE_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelnes Equipment | ![]() |
![]() |
![]() |
290 | ![]() |
ITOB_EQUIPMENT_CREATE_SINGLE VALUE(I_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelnes Equipment | ![]() |
![]() |
![]() |
291 | ![]() |
ITOB_EQUIPMENT_CREATE_SING_REF
|
ITOB Puffer RFC: Anlegen einzelnes Equipment mit Vorlage | ![]() |
![]() |
![]() |
292 | ![]() |
ITOB_EQUIPMENT_CREATE_SING_REF VALUE(I_REFOBJ_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelnes Equipment mit Vorlage | ![]() |
![]() |
![]() |
293 | ![]() |
ITOB_EQUIPMENT_CREATE_SING_REF VALUE(I_OBJNR) LIKE ITOB-EQUNR OPTIONAL
|
ITOB Puffer RFC: Anlegen einzelnes Equipment mit Vorlage | ![]() |
![]() |
![]() |
294 | ![]() |
ITOB_EQUIPMENT_CREATE_SING_REF VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelnes Equipment mit Vorlage | ![]() |
![]() |
![]() |
295 | ![]() |
ITOB_EQUIPMENT_ENHANCED_READ
|
RFC: Lesen eines Equipments mit Zusatzdaten | ![]() |
![]() |
![]() |
296 | ![]() |
ITOB_EQUIPMENT_ENHANCED_READ VALUE(ES_OBJECT_REC) TYPE ITOB
|
RFC: Lesen eines Equipments mit Zusatzdaten | ![]() |
![]() |
![]() |
297 | ![]() |
ITOB_EQUIPMENT_LOCK_SINGLE VALUE(I_OBJNR) LIKE ITOB-EQUNR
|
ITOB Puffer API: Sperren einzelnes Equipment | ![]() |
![]() |
![]() |
298 | ![]() |
ITOB_EQUIPMENT_MODIFY_SINGLE VALUE(I_OBJECT_REC_OLD) LIKE ITOB OPTIONAL
|
ITOB Puffer RFC: Ändern einzelnes Equipment | ![]() |
![]() |
![]() |
299 | ![]() |
ITOB_EQUIPMENT_MODIFY_SINGLE
|
ITOB Puffer RFC: Ändern einzelnes Equipment | ![]() |
![]() |
![]() |
300 | ![]() |
ITOB_EQUIPMENT_MODIFY_SINGLE VALUE(I_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Ändern einzelnes Equipment | ![]() |
![]() |
![]() |
301 | ![]() |
ITOB_EQUIPMENT_MODIFY_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Ändern einzelnes Equipment | ![]() |
![]() |
![]() |
302 | ![]() |
ITOB_EQUIPMENT_NUMBER_CHECK
|
ITOB. Prüfen Equipmentnummer auf ungültige Zeichen, zulässige Intervalle | ![]() |
![]() |
![]() |
303 | ![]() |
ITOB_EQUIPMENT_READ_SINGLE VALUE(I_OBJNR) LIKE ITOB-EQUNR
|
ITOB Puffer RFC: Lesen einzelnes Equipment | ![]() |
![]() |
![]() |
304 | ![]() |
ITOB_EQUIPMENT_READ_SINGLE
|
ITOB Puffer RFC: Lesen einzelnes Equipment | ![]() |
![]() |
![]() |
305 | ![]() |
ITOB_EQUIPMENT_READ_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Lesen einzelnes Equipment | ![]() |
![]() |
![]() |
306 | ![]() |
ITOB_EQUIPMENT_UNLOCK_SINGLE VALUE(I_OBJNR) LIKE ITOB-EQUNR
|
ITOB Puffer API: Entsperren einzelnes Equipment | ![]() |
![]() |
![]() |
307 | ![]() |
ITOB_FILTER_DATA REFERENCE(I_OBJECT_REC_OLD) LIKE ITOB OPTIONAL
|
ITOB: Ausfiltern nicht pflegbarer ITOB-Daten | ![]() |
![]() |
![]() |
308 | ![]() |
ITOB_FILTER_DATA
|
ITOB: Ausfiltern nicht pflegbarer ITOB-Daten | ![]() |
![]() |
![]() |
309 | ![]() |
ITOB_FILTER_DATA REFERENCE(C_OBJECT_REC) LIKE ITOB OPTIONAL
|
ITOB: Ausfiltern nicht pflegbarer ITOB-Daten | ![]() |
![]() |
![]() |
310 | ![]() |
ITOB_FUNCLOC_CREATE_SINGLE VALUE(I_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelner Technischer Platz | ![]() |
![]() |
![]() |
311 | ![]() |
ITOB_FUNCLOC_CREATE_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelner Technischer Platz | ![]() |
![]() |
![]() |
312 | ![]() |
ITOB_FUNCLOC_CREATE_SINGLE
|
ITOB Puffer RFC: Anlegen einzelner Technischer Platz | ![]() |
![]() |
![]() |
313 | ![]() |
ITOB_FUNCLOC_ENHANCED_READ VALUE(ES_OBJECT_REC) TYPE ITOB
|
RFC: Lesen eines Technischen Platzes mit Zusatzdaten | ![]() |
![]() |
![]() |
314 | ![]() |
ITOB_FUNCLOC_ENHANCED_READ
|
RFC: Lesen eines Technischen Platzes mit Zusatzdaten | ![]() |
![]() |
![]() |
315 | ![]() |
ITOB_FUNCLOC_MODIFY_SINGLE VALUE(I_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Ändern einzelner Technischer Platz | ![]() |
![]() |
![]() |
316 | ![]() |
ITOB_FUNCLOC_MODIFY_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Ändern einzelner Technischer Platz | ![]() |
![]() |
![]() |
317 | ![]() |
ITOB_FUNCLOC_MODIFY_SINGLE
|
ITOB Puffer RFC: Ändern einzelner Technischer Platz | ![]() |
![]() |
![]() |
318 | ![]() |
ITOB_FUNCLOC_MODIFY_SINGLE VALUE(I_OBJECT_REC_OLD) LIKE ITOB OPTIONAL
|
ITOB Puffer RFC: Ändern einzelner Technischer Platz | ![]() |
![]() |
![]() |
319 | ![]() |
ITOB_FUNCLOC_READ_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Lesen einzelner Technischer Platz | ![]() |
![]() |
![]() |
320 | ![]() |
ITOB_FUNCLOC_READ_SINGLE
|
ITOB Puffer RFC: Lesen einzelner Technischer Platz | ![]() |
![]() |
![]() |
321 | ![]() |
ITOB_GET_CLASS_STANDARD VALUE(TPLNR_IMP) LIKE ITOB-TPLNR OPTIONAL
|
L1: Lesen Standardklasse zum Technischen Objekt | ![]() |
![]() |
![]() |
322 | ![]() |
ITOB_GET_CLASS_STANDARD VALUE(EQUNR_IMP) LIKE ITOB-EQUNR OPTIONAL
|
L1: Lesen Standardklasse zum Technischen Objekt | ![]() |
![]() |
![]() |
323 | ![]() |
ITOB_GET_LONG_TEXT VALUE(EQUNR_IMP) LIKE ITOB-EQUNR OPTIONAL
|
L1: Lesen Langtext zum Technischen Objekt | ![]() |
![]() |
![]() |
324 | ![]() |
ITOB_GET_LONG_TEXT VALUE(TPLNR_IMP) LIKE ITOB-TPLNR OPTIONAL
|
L1: Lesen Langtext zum Technischen Objekt | ![]() |
![]() |
![]() |
325 | ![]() |
ITOB_HANDLE_CHANGEFLAGS
|
Behandlung der Änderungsflags | ![]() |
![]() |
![]() |
326 | ![]() |
ITOB_HANDLE_CHANGEFLAGS REFERENCE(I_OBJECT_NEW) LIKE ITOB
|
Behandlung der Änderungsflags | ![]() |
![]() |
![]() |
327 | ![]() |
ITOB_HANDLE_CHANGEFLAGS REFERENCE(C_OBJECT_OLD) LIKE ITOB
|
Behandlung der Änderungsflags | ![]() |
![]() |
![]() |
328 | ![]() |
ITOB_MOVE_ATTR REFERENCE(I_ITOB) LIKE ITOB
|
ITOB: Move attributes from Buffers/DB to Structure ITOB | ![]() |
![]() |
![]() |
329 | ![]() |
ITOB_MOVE_DATA REFERENCE(C_ITOB) LIKE ITOB
|
ITOB: Subsequent moves from db buffers into ITOB structure | ![]() |
![]() |
![]() |
330 | ![]() |
ITOB_MOVE_DATA
|
ITOB: Subsequent moves from db buffers into ITOB structure | ![]() |
![]() |
![]() |
331 | ![]() |
ITOB_OBJECT_CREATE
|
ITOB Puffer API: Anlegen Technischer Objekte | ![]() |
![]() |
![]() |
332 | ![]() |
ITOB_OBJECT_GET_BEGRU
|
Auslesen der Berechtigungsgruppe eines technischen Objektes | ![]() |
![]() |
![]() |
333 | ![]() |
ITOB_OBJECT_MODIFY
|
ITOB Puffer API: Ändern Technischer Objekte | ![]() |
![]() |
![]() |
334 | ![]() |
ITOB_OBJECT_READ
|
ITOB Puffer API: Lesen Technischer Objekte | ![]() |
![]() |
![]() |
335 | ![]() |
ITOB_PREPARE_BADI
|
ITOB: Daten für BADI-Bausteine mappen | ![]() |
![]() |
![]() |
336 | ![]() |
ITOB_PREPARE_BADI REFERENCE(I_ITOB_REC) LIKE ITOB
|
ITOB: Daten für BADI-Bausteine mappen | ![]() |
![]() |
![]() |
337 | ![]() |
ITOB_READ_FLEET REFERENCE(I_ITOB) LIKE ITOB OPTIONAL
|
Lesen Flottenobjektsegment (FLEET) | ![]() |
![]() |
![]() |
338 | ![]() |
ITOB_READ_FLEET
|
Lesen Flottenobjektsegment (FLEET) | ![]() |
![]() |
![]() |
339 | ![]() |
ITOB_REFERENCE_MATERIAL VALUE(E_TPLNR) LIKE ITOB-TPLNR
|
ITOB: Prüfung Referenz Techn.Objekte auf Materialnummer | ![]() |
![]() |
![]() |
340 | ![]() |
ITOB_REFERENCE_MATERIAL VALUE(E_TRPNR) LIKE ITOB-TRPNR
|
ITOB: Prüfung Referenz Techn.Objekte auf Materialnummer | ![]() |
![]() |
![]() |
341 | ![]() |
ITOB_REFERENCE_MATERIAL VALUE(E_EQUNR) LIKE ITOB-EQUNR
|
ITOB: Prüfung Referenz Techn.Objekte auf Materialnummer | ![]() |
![]() |
![]() |
342 | ![]() |
ITOB_REFERENCE_MATERIAL VALUE(I_MATNR) LIKE ITOB-MATNR
|
ITOB: Prüfung Referenz Techn.Objekte auf Materialnummer | ![]() |
![]() |
![]() |
343 | ![]() |
ITOB_SERIALNO_CREATE_SINGLE
|
ITOB Puffer RFC: Anlegen einzelne Serialnummer | ![]() |
![]() |
![]() |
344 | ![]() |
ITOB_SERIALNO_CREATE_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelne Serialnummer | ![]() |
![]() |
![]() |
345 | ![]() |
ITOB_SERIALNO_CREATE_SINGLE VALUE(I_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Anlegen einzelne Serialnummer | ![]() |
![]() |
![]() |
346 | ![]() |
ITOB_SERIALNO_LOCK_SINGLE VALUE(I_MATNR) LIKE ITOB-MATNR
|
ITOB Puffer API: Sperren einzelne Serialnummer | ![]() |
![]() |
![]() |
347 | ![]() |
ITOB_SERIALNO_LOCK_SINGLE VALUE(I_SERNR) LIKE ITOB-SERNR
|
ITOB Puffer API: Sperren einzelne Serialnummer | ![]() |
![]() |
![]() |
348 | ![]() |
ITOB_SERIALNO_MODIFY_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Ändern einzelne Serialnummer | ![]() |
![]() |
![]() |
349 | ![]() |
ITOB_SERIALNO_MODIFY_SINGLE
|
ITOB Puffer RFC: Ändern einzelne Serialnummer | ![]() |
![]() |
![]() |
350 | ![]() |
ITOB_SERIALNO_MODIFY_SINGLE VALUE(I_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Ändern einzelne Serialnummer | ![]() |
![]() |
![]() |
351 | ![]() |
ITOB_SERIALNO_MODIFY_SINGLE VALUE(I_OBJECT_REC_OLD) LIKE ITOB OPTIONAL
|
ITOB Puffer RFC: Ändern einzelne Serialnummer | ![]() |
![]() |
![]() |
352 | ![]() |
ITOB_SERIALNO_READ_SINGLE
|
ITOB Puffer RFC: Lesen einzelne Serialnummer | ![]() |
![]() |
![]() |
353 | ![]() |
ITOB_SERIALNO_READ_SINGLE VALUE(E_OBJECT_REC) LIKE ITOB
|
ITOB Puffer RFC: Lesen einzelne Serialnummer | ![]() |
![]() |
![]() |
354 | ![]() |
ITOB_SERIALNO_READ_SINGLE VALUE(I_MATNR) LIKE ITOB-MATNR
|
ITOB Puffer RFC: Lesen einzelne Serialnummer | ![]() |
![]() |
![]() |
355 | ![]() |
ITOB_SERIALNO_READ_SINGLE VALUE(I_UII) TYPE ITOB-UII OPTIONAL
|
ITOB Puffer RFC: Lesen einzelne Serialnummer | ![]() |
![]() |
![]() |
356 | ![]() |
ITOB_SERIALNO_READ_SINGLE VALUE(I_SERNR) LIKE ITOB-SERNR
|
ITOB Puffer RFC: Lesen einzelne Serialnummer | ![]() |
![]() |
![]() |
357 | ![]() |
ITOB_SERIALNO_UNLOCK_SINGLE VALUE(I_SERNR) LIKE ITOB-SERNR
|
ITOB Puffer API: Entsperren einzelne Serialnummer | ![]() |
![]() |
![]() |
358 | ![]() |
ITOB_SERIALNO_UNLOCK_SINGLE VALUE(I_MATNR) LIKE ITOB-MATNR
|
ITOB Puffer API: Entsperren einzelne Serialnummer | ![]() |
![]() |
![]() |
359 | ![]() |
ITOB_SET_LONG_TEXT VALUE(EQUNR_IMP) LIKE ITOB-EQUNR OPTIONAL
|
L1: Setzen Langtext zum Technischen Objekt | ![]() |
![]() |
![]() |
360 | ![]() |
ITOB_SET_LONG_TEXT VALUE(TPLNR_IMP) LIKE ITOB-TPLNR OPTIONAL
|
L1: Setzen Langtext zum Technischen Objekt | ![]() |
![]() |
![]() |
361 | ![]() |
ITOB_TRANS_CHECK_CONTROLS
|
Checks ITO0 text control status | ![]() |
![]() |
![]() |
362 | ![]() |
ITOB_TRANS_CHECK_CONTROLS VALUE(C_LONGTEXT_EXISTS) LIKE ITOB-KZLTX OPTIONAL
|
Checks ITO0 text control status | ![]() |
![]() |
![]() |
363 | ![]() |
MAM25_070_GETDETAIL
|
Technikerbestand eines Materials/Equipments | ![]() |
![]() |
![]() |
364 | ![]() |
MAM30_070_GETDETAIL
|
Technikerbestand eines Materials/Equipments | ![]() |
![]() |
![]() |
365 | ![]() |
MAM30_070_GETDETAIL_SD
|
Inventory get detail for server driven | ![]() |
![]() |
![]() |
366 | ![]() |
MAP2E_ITOB_TO_ALM_BAPI_ITOB REFERENCE(ITOB) LIKE ITOB
|
itob -> alm_me_pm_bapi_itob | ![]() |
![]() |
![]() |
367 | ![]() |
MAP2E_ITOB_TO_ALM_BAPI_ITOB
|
itob -> alm_me_pm_bapi_itob | ![]() |
![]() |
![]() |
368 | ![]() |
MAP2E_ITOB_TO_ALM_BAPI_ITOB_EQ
|
itob -> alm_me_pm_bapi_itob_eq_only | ![]() |
![]() |
![]() |
369 | ![]() |
MAP2E_ITOB_TO_ALM_BAPI_ITOB_EQ REFERENCE(ITOB) LIKE ITOB
|
itob -> alm_me_pm_bapi_itob_eq_only | ![]() |
![]() |
![]() |
370 | ![]() |
MAP2E_ITOB_TO_ALM_BAPI_ITOB_FL REFERENCE(ITOB) LIKE ITOB
|
itob -> alm_me_pm_bapi_itob_fl_only | ![]() |
![]() |
![]() |
371 | ![]() |
MAP2E_ITOB_TO_ALM_BAPI_ITOB_FL
|
itob -> alm_me_pm_bapi_itob_fl_only | ![]() |
![]() |
![]() |
372 | ![]() |
MAP2E_ITOB_TO_BAPI_ITOB REFERENCE(ITOB) LIKE ITOB
|
itob -> bapi_itob | ![]() |
![]() |
![]() |
373 | ![]() |
MAP2E_ITOB_TO_BAPI_ITOB
|
itob -> bapi_itob | ![]() |
![]() |
![]() |
374 | ![]() |
MAP2E_ITOB_TO_BAPI_ITOB_EQ_ONL REFERENCE(ITOB) LIKE ITOB
|
itob -> bapi_itob_eq_only | ![]() |
![]() |
![]() |
375 | ![]() |
MAP2E_ITOB_TO_BAPI_ITOB_EQ_ONL
|
itob -> bapi_itob_eq_only | ![]() |
![]() |
![]() |
376 | ![]() |
MAP2E_ITOB_TO_BAPI_ITOB_FL_ONL
|
itob -> bapi_itob_fl_only | ![]() |
![]() |
![]() |
377 | ![]() |
MAP2E_ITOB_TO_BAPI_ITOB_FL_ONL REFERENCE(ITOB) LIKE ITOB
|
itob -> bapi_itob_fl_only | ![]() |
![]() |
![]() |
378 | ![]() |
MAPXI_ALM_ME_PM_BAPI_ITOB_EQ_O
|
alm_me_pm_bapi_itob_eq_only -> itob | ![]() |
![]() |
![]() |
379 | ![]() |
MAPXI_ALM_ME_PM_BAPI_ITOB_EQ_O REFERENCE(ITOB) LIKE ITOB
|
alm_me_pm_bapi_itob_eq_only -> itob | ![]() |
![]() |
![]() |
380 | ![]() |
MAPXI_ALM_ME_PM_BAPI_ITOB_TO_I
|
alm_me_pm_bapi_itob -> itob | ![]() |
![]() |
![]() |
381 | ![]() |
MAPXI_ALM_ME_PM_BAPI_ITOB_TO_I REFERENCE(ITOB) LIKE ITOB
|
alm_me_pm_bapi_itob -> itob | ![]() |
![]() |
![]() |
382 | ![]() |
MAPXI_BAPI_ITOB_EQ_ONLY_TO_ITO
|
bapi_itob_eq_only -> itob | ![]() |
![]() |
![]() |
383 | ![]() |
MAPXI_BAPI_ITOB_EQ_ONLY_TO_ITO REFERENCE(ITOB) LIKE ITOB
|
bapi_itob_eq_only -> itob | ![]() |
![]() |
![]() |
384 | ![]() |
MAPXI_BAPI_ITOB_FL_ONLY_TO_ITO
|
bapi_itob_fl_only -> itob | ![]() |
![]() |
![]() |
385 | ![]() |
MAPXI_BAPI_ITOB_FL_ONLY_TO_ITO REFERENCE(ITOB) LIKE ITOB
|
bapi_itob_fl_only -> itob | ![]() |
![]() |
![]() |
386 | ![]() |
MAPXI_BAPI_ITOB_TO_ITOB
|
bapi_itob -> itob | ![]() |
![]() |
![]() |
387 | ![]() |
MAPXI_BAPI_ITOB_TO_ITOB REFERENCE(ITOB) LIKE ITOB
|
bapi_itob -> itob | ![]() |
![]() |
![]() |
388 | ![]() |
MP_RFC_SINGLE_CREATE
|
RFC: Messpunkt anlegen | ![]() |
![]() |
![]() |
389 | ![]() |
MP_TRANS_WITHIN_OBJECT VALUE(IS_ITOB) TYPE ITOB
|
Messwertweitergabe innerhalb eines Objekts | ![]() |
![]() |
![]() |
390 | ![]() |
MP_TRANS_WITHIN_OBJECT
|
Messwertweitergabe innerhalb eines Objekts | ![]() |
![]() |
![]() |
391 | ![]() |
MSAM10_FUNCLOCATION_CREATE
|
PM/CS: Functional location Change | ![]() |
![]() |
![]() |
392 | ![]() |
MSAM_MO_ADDR_CREATE
|
Change Address of Technical Object | ![]() |
![]() |
![]() |
393 | ![]() |
MSAM_MO_ADDR_TECH_CHANGE
|
Change Address of Technical Object | ![]() |
![]() |
![]() |
394 | ![]() |
MSAM_MO_EQUIPMENT_CHANGE
|
Change Equipment | ![]() |
![]() |
![]() |
395 | ![]() |
MSAM_MO_EQUIPMENT_CREATE
|
Create Equipment | ![]() |
![]() |
![]() |
396 | ![]() |
MSAM_MO_EQUIPMENT_GETDETAIL
|
Detail Data of the Equipment | ![]() |
![]() |
![]() |
397 | ![]() |
MSAM_MO_EQUI_HEADER
|
Fetch Equipment Header Data | ![]() |
![]() |
![]() |
398 | ![]() |
MSAM_MO_EQUI_HEADER VALUE(E_OBJECTNUMBER) TYPE ITOB-OBJNR
|
Fetch Equipment Header Data | ![]() |
![]() |
![]() |
399 | ![]() |
MSAM_MO_EQUI_SUBOBJS_COPY
|
A FM to copy measurement points and partners | ![]() |
![]() |
![]() |
400 | ![]() |
MSAM_MO_EQUI_USTATUS_CHANGE
|
Changing of the User Status | ![]() |
![]() |
![]() |
401 | ![]() |
MSAM_MO_EQ_RNODE_GETLIST
|
List out the Funcloc root node objects | ![]() |
![]() |
![]() |
402 | ![]() |
MSAM_MO_FLOC_USTATUS_CHANGE
|
Changing User Status Functional Location | ![]() |
![]() |
![]() |
403 | ![]() |
MSAM_MO_FUNCLOC_CHANGE
|
Changes to the Technical Object | ![]() |
![]() |
![]() |
404 | ![]() |
MSAM_MO_FUNCLOC_CREATE
|
Changes to the Technical Object | ![]() |
![]() |
![]() |
405 | ![]() |
MSAM_MO_FUNCLOC_GETDETAIL
|
Detail Data of the Functional Location | ![]() |
![]() |
![]() |
406 | ![]() |
MSAM_MO_FUNCLOC_HEADER
|
Fetch Header Data of the Functional Location | ![]() |
![]() |
![]() |
407 | ![]() |
MSAM_MO_FUNCLOC_HEADER VALUE(E_OBJECTNUMBER) TYPE ITOB-OBJNR
|
Fetch Header Data of the Functional Location | ![]() |
![]() |
![]() |
408 | ![]() |
MSAM_MO_FUNC_SUBOBJS_COPY
|
A FM to copy measurement points and partners | ![]() |
![]() |
![]() |
409 | ![]() |
MSAM_MO_GET_TEMPLATE_FUNCLOC
|
Get the template functional location data | ![]() |
![]() |
![]() |
410 | ![]() |
MSAM_MO_MEAS_PTS_PARTNERS_COPY
|
A FM to copy measurement points and partners | ![]() |
![]() |
![]() |
411 | ![]() |
MSAM_MO_ORDER_CREATE
|
MSAM: Create Order | ![]() |
![]() |
![]() |
412 | ![]() |
MSAM_MO_PARTNER_MAINTAIN
|
MSAM: Maintain Partner | ![]() |
![]() |
![]() |
413 | ![]() |
MSAM_MO_PARTNER_MAINTAIN REFERENCE(CS_ITOB) TYPE ITOB
|
MSAM: Maintain Partner | ![]() |
![]() |
![]() |
414 | ![]() |
MSAM_MO_TECHOBJ_MEASUREMENT_PT VALUE(I_OBJNR) LIKE ITOB-OBJNR
|
Selects all Measurement Points to a Technical Object | ![]() |
![]() |
![]() |
415 | ![]() |
MSAM_MO_TECHOBJ_PARTNERS VALUE(I_OBJNR) TYPE ITOB-OBJNR
|
Partners in the Technical Object | ![]() |
![]() |
![]() |
416 | ![]() |
MSAM_MO_TECHOBJ_WARRANTY VALUE(I_OBJNR) LIKE ITOB-OBJNR
|
Warranties for the Technical Object | ![]() |
![]() |
![]() |
417 | ![]() |
OBJECT_CHECK_EQUI
|
Check if Equi Exists for Classification (Otherwise Do Not Use) | ![]() |
![]() |
![]() |
418 | ![]() |
OBJECT_GET_ACCESS_LEVEL VALUE(ID_EQUNR) LIKE ITOB-EQUNR OPTIONAL
|
Lesen des Zugriffslevels auf ein Objekt | ![]() |
![]() |
![]() |
419 | ![]() |
OBJECT_SET_ACCESS_LEVEL VALUE(ID_EQUNR) LIKE ITOB-EQUNR OPTIONAL
|
Setzen des Zugriffslevels für ein Objekt | ![]() |
![]() |
![]() |
420 | ![]() |
PAMS_HNDL_SEND_MAIL
|
Versenden eines Emails | ![]() |
![]() |
![]() |
421 | ![]() |
PERMITS_FOR_OBJECT
|
Genehmigungen vom Puffer lesen | ![]() |
![]() |
![]() |
422 | ![]() |
PM_OBJECT_SCREEN
|
Allgemeinebearbeitung Objektbildbaustein | ![]() |
![]() |
![]() |
423 | ![]() |
PM_PARTNER_MAINTAIN
|
Partner in Partnerverarbeitung ändern/hinzufühen | ![]() |
![]() |
![]() |
424 | ![]() |
PREPARE_IUID_HIERARCHY_DATA
|
Prepare data for IUID hierarchy check | ![]() |
![]() |
![]() |
425 | ![]() |
REEX_FL_HAS_OBJASS
|
Zuordnung TP zu RE-FX Objekt feststellen | ![]() |
![]() |
![]() |
426 | ![]() |
RPLM_MP_GET_REF_FL
|
Returns Reference Functional Location | ![]() |
![]() |
![]() |
427 | ![]() |
RPLM_OBJ_HIST_ITM_DESC_FM
|
Fetches the Description Text | ![]() |
![]() |
![]() |
428 | ![]() |
RPLM_OBJ_HIST_ITM_DESC_FM REFERENCE(SHTXT) TYPE ITOB-SHTXT
|
Fetches the Description Text | ![]() |
![]() |
![]() |
429 | ![]() |
SERIALNUMBER_ARRAY
|
Array Fetch für Serialnummern | ![]() |
![]() |
![]() |
430 | ![]() |
SERIALNUMBER_CHECK_UPDATE_EQBS
|
Check Bestandsupdate (EQBS) Equipment/Serialnummer | ![]() |
![]() |
![]() |
431 | ![]() |
SERIALNUMBER_CHECK_UPDATE_EQBS REFERENCE(C_REC_ITOB) LIKE ITOB OPTIONAL
|
Check Bestandsupdate (EQBS) Equipment/Serialnummer | ![]() |
![]() |
![]() |
432 | ![]() |
SERIALNUMBER_LIST_SAVE
|
Serialnummer aus Liste verbuchen | ![]() |
![]() |
![]() |
433 | ![]() |
SERIALNUMBER_READ
|
Read serial number record | ![]() |
![]() |
![]() |
434 | ![]() |
SUBEQUI_READ_ONLY
|
Lesen von Unterequipments zu einem bestimmten Zeitpunkt (1-stufig) | ![]() |
![]() |
![]() |
435 | ![]() |
WARRANTY_OBJEKT_GET REFERENCE(I_ITOB) TYPE ITOB OPTIONAL
|
Garantieprüfung Equipment/tech.Platz übernehmen | ![]() |
![]() |
![]() |
436 | ![]() |
WARRANTY_OBJEKT_GET
|
Garantieprüfung Equipment/tech.Platz übernehmen | ![]() |
![]() |
![]() |
437 | ![]() |
WCGW_EQUIPMENT_READ_SINGLE
|
WCM: Stammdaten Equipment lesen | ![]() |
![]() |
![]() |
438 | ![]() |
WCGW_FUNC_LOCATION_READ_SINGLE
|
WCM: Stammdaten Technischer Platz lesen | ![]() |
![]() |
![]() |
439 | ![]() |
WTY09_MEASURE_POINT_DETERMINE
|
Messpunkte zum Objekt bestimmen | ![]() |
![]() |
![]() |
440 | ![]() |
WTY20_DB_UPDATE_BGMKOBJ2
|
Update BGMKOBJ | ![]() |
![]() |
![]() |
441 | ![]() |
WTY20_OBJNR_DETERMINE
|
Objektnummer ermitteln von technischen Objekt | ![]() |
![]() |
![]() |
442 | ![]() |
WTY20_OBJNR_DETERMINE REFERENCE(EV_OBJNR) TYPE ITOB-OBJNR
|
Objektnummer ermitteln von technischen Objekt | ![]() |
![]() |
![]() |
443 | ![]() |
WTY20_OBJNR_DETERMINE REFERENCE(ES_ITOB) TYPE ITOB
|
Objektnummer ermitteln von technischen Objekt | ![]() |
![]() |
![]() |
444 | ![]() |
WTY20_TABLE_BUFFER_REFRESH
|
Löschen des Tabellen und Variablen im Puffer | ![]() |
![]() |
![]() |