SAP ABAP Table QGEVAL_TS_CHARACTERISTIC_VIEW (Structure for Characteristics Table)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
QM-QC-AQC (Application Component) Active Quality Control
⤷
QG_EVAL (Package) QM: Online Evaluations
⤷
⤷
Basic Data
| Table Category | INTTAB | Structure |
| Structure | QGEVAL_TS_CHARACTERISTIC_VIEW |
|
| Short Description | Structure for Characteristics Table |
Delivery and Maintenance
| Pool/cluster | ||
| Delivery Class | ||
| Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
| |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|---|---|---|---|---|---|---|---|---|---|
| 1 | |
0 | 0 | QM Evaluations: Data Structure for Characteristics | |||||
| 2 | |
QPLOS | QPLOS | NUMC | 12 | 0 | Inspection Lot Number | * | |
| 3 | |
QTLOS | QTLOS | NUMC | 6 | 0 | Partial lot number | * | |
| 4 | |
QLFNKN | KNTNR | NUMC | 8 | 0 | Current Node Number from Order Counter APLZL | ||
| 5 | |
QPROBENRPP | QPROBENR | NUMC | 6 | 0 | Sample Number (Based on an Inspection Point) | * | |
| 6 | |
QMERKNRP | QMERKNRP | NUMC | 4 | 0 | Inspection Characteristic Number | ||
| 7 | |
VORNR | VORNR | CHAR | 4 | 0 | Operation/Activity Number | ||
| 8 | |
QBEASTATUS | QSTATUS | CHAR | 1 | 0 | Results Record Status | * | |
| 9 | |
QATTRIBUT | QATTRIBUT | CHAR | 1 | 0 | Attribute of the Results Record (Valid, Invalid,...) | ||
| 10 | |
QERGDATH | QERGDATH | CHAR | 2 | 0 | Origin of Results Data | * | |
| 11 | |
QDATUMERST | DATUM | DATS | 8 | 0 | Date on Which the Data Record Was Created | ||
| 12 | |
QDATUMAEND | DATUM | DATS | 8 | 0 | Date on Which Data Record Was Changed | ||
| 13 | |
QDBEWERTG | QEEBEWERTG | CHAR | 1 | 0 | Valuation of the Characteristic for Dynamic Modification | ||
| 14 | |
QMBEWERTG | QEEBEWERTG | CHAR | 1 | 0 | Inspection Result Valuation | ||
| 15 | |
QPRUEFDATV | DATUM | DATS | 8 | 0 | Inspection Start Date | ||
| 16 | |
QPRUEFZTV | QZEIT | TIMS | 6 | 0 | Starting Time of the Inspection | ||
| 17 | |
QKURZTEXT | QKURZTEXT | CHAR | 40 | 0 | Short Text | ||
| 18 | |
QANZSTIPRO | QANZAHL2 | INT2 | 5 | 0 | Number of Partial Samples for the Characteristic | ||
| 19 | |
QISTSTPUMF | QANZAHL4 | INT4 | 10 | 0 | Number of Recorded Sample Units | ||
| 20 | |
QANZFEHEH4 | QANZAHL4 | INT4 | 10 | 0 | Number of Nonconforming Sample Units | ||
| 21 | |
QANZFEHL4 | QANZAHL4 | INT4 | 10 | 0 | Number of Defects Found | ||
| 22 | |
QANZWERTO4 | QANZAHL4 | INT4 | 10 | 0 | Number of Measured Values Above the Tolerance Range | ||
| 23 | |
QANZWERTU4 | QANZAHL4 | INT4 | 10 | 0 | Number of Measured Values Below the Tolerance Range | ||
| 24 | |
QANZWERTG4 | QANZAHL4 | INT4 | 10 | 0 | Number of Inspected Sample Units | ||
| 25 | |
QMAXWERT | QSTATWERT | FLTP | 16 | 16 | Maximum Value of the Valid Measured Values | ||
| 26 | |
QMINWERT | QSTATWERT | FLTP | 16 | 16 | Minimum Value of the Valid Measured Values | ||
| 27 | |
QMITTELWRT | QSTATWERT | FLTP | 16 | 16 | Arithmetic Mean of Valid Measured Values | ||
| 28 | |
QVARIANZ | QSTATWERT | FLTP | 16 | 16 | Dispersion (Variance) of Valid Measured Values | ||
| 29 | |
QANTEILO | QSTATWERT | FLTP | 16 | 16 | Estimated Fraction Above the Tolerance Range | ||
| 30 | |
QANTEILU | QSTATWERT | FLTP | 16 | 16 | Estimated Fraction Below the Tolerance Range | ||
| 31 | |
QIVARIANZ | QSTATWERT | FLTP | 16 | 16 | Internal Dispersion of Valid Measured Values | ||
| 32 | |
QKATAUSW | QKATART | CHAR | 1 | 0 | Catalog Type of Assigned Code Group or Selected Set | * | |
| 33 | |
QCGRAUSW | QCGRAUSW | CHAR | 8 | 0 | Assigned Code Group or Selected Set | ||
| 34 | |
QWERKAUSW | WERKS | CHAR | 4 | 0 | Plant of the Assigned Selected Set | * | |
| 35 | |
QCODEGRP | QCODEGRP | CHAR | 8 | 0 | Code Group | * | |
| 36 | |
QCODE | QCODE | CHAR | 4 | 0 | Code | * | |
| 37 | |
QVERSNR | QVERSNR | CHAR | 6 | 0 | Version Number | ||
| 38 | |
QFEHLKLAS | QFEHLKLAS | CHAR | 2 | 0 | Defect class | * | |
| 39 | |
QQRKNR | QQRKNR | NUMC | 12 | 0 | Control Chart Number | * | |
| 40 | |
QPRSTUFE | QPRSTUFE | NUMC | 4 | 0 | Inspection Stage | * | |
| 41 | |
QPRSCHAERF | QPRSCHAERF | NUMC | 3 | 0 | Inspection Severity | * | |
| 42 | |
QZAEHLER | QZAEHLER | CHAR | 4 | 0 | Plant for the Master Inspection Characteristic | ||
| 43 | |
QMERKNR | QMERKNR | CHAR | 8 | 0 | Master Inspection Characteristics | * | |
| 44 | |
QVERSNRMK | QVERSNR | CHAR | 6 | 0 | Version Number of the Master Inspection Characteristic | ||
| 45 | |
QPMETHODE | QPMETHODE | CHAR | 8 | 0 | Inspection Method | * | |
| 46 | |
QSTELLEN | QSTELLEN | INT1 | 3 | 0 | Number of Places to the Right of a Decimal Point (Accuracy) | ||
| 47 | |
QMASSEH | MEINS | UNIT | 3 | 0 | Unit of Measurement, in Which Quantitative Data Is Stored | * | |
| 48 | |
QSOLLWERTE | QSOLLWERTE | FLTP | 16 | 16 | Target Value for a Quantitative Characteristic | ||
| 49 | |
QTOLOB | QSOLLWERTE | FLTP | 16 | 16 | Upper Specification Limit | ||
| 50 | |
QTOLUN | QSOLLWERTE | FLTP | 16 | 16 | Lower Tolerance Limit | ||
| 51 | |
QEANTVERF | QEANTVERF | CHAR | 2 | 0 | Fraction Calculation | * | |
| 52 | |
QPROBEMGEH | MEINS | UNIT | 3 | 0 | Base Unit of Measure for the Sample Unit | * | |
| 53 | |
QCHARACT_ID1 | QCHARACT_ID | CHAR | 40 | 0 | Characteristic Description for Quality Data Exchange | ||
| 54 | |
QMASCHINE | QEQUNR | CHAR | 18 | 0 | General Information | ||
| 55 | |
0 | 0 | Characteristic control indicators | |||||
| 56 | |
QKZQUNMK | QKZ | CHAR | 1 | 0 | Quantitative Characteristic | ||
| 57 | |
QKZQUMK | QKZ | CHAR | 1 | 0 | Measured Values Must Be Recorded | ||
| 58 | |
QKZPKAT | QKZ | CHAR | 1 | 0 | Reference to Characteristic Attribute Required | ||
| 59 | |
QKZTOLOB | QKZ | CHAR | 1 | 0 | Upper Specification Limit | ||
| 60 | |
QKZTOLUN | QKZ | CHAR | 1 | 0 | Lower Specification Limit | ||
| 61 | |
QKZSOLLPR | QKZ | CHAR | 1 | 0 | Check Target Value | ||
| 62 | |
QPUMFKZ | QPUMFKZ | CHAR | 1 | 0 | Inspection Scope | ||
| 63 | |
QLZEITKZ | QKZ | CHAR | 1 | 0 | Long-Term Inspection | ||
| 64 | |
QESTUKZ | QESTUKZ | CHAR | 1 | 0 | Recording Type | ||
| 65 | |
QDOKUKZ | QDOKUKZ | CHAR | 1 | 0 | Documentation Required for Inspection Results | ||
| 66 | |
QRZWANG | QRZWANG | CHAR | 1 | 0 | Characteristic Category | ||
| 67 | |
QSYNCRO | QKZ | CHAR | 1 | 0 | Synchronization is Active | ||
| 68 | |
QADDPRO | QKZ | CHAR | 1 | 0 | Sample Quantity Is Added | ||
| 69 | |
QKZDESTROY | QKZ | CHAR | 1 | 0 | Destructive Inspection | ||
| 70 | |
QKZFORMEL | QKZFORMEL | CHAR | 1 | 0 | Calculated Characteristic | ||
| 71 | |
QSTICHPR | QKZ | CHAR | 1 | 0 | Sampling Procedure is Required | ||
| 72 | |
QAUSSLOS | QKZ | CHAR | 1 | 0 | Characteristic Relevant for Qual. Score and Scrap Share | ||
| 73 | |
QNAENDKZ | QKZ | CHAR | 1 | 0 | Default Control Indicators Cannot Be Changed | ||
| 74 | |
QBFHLZHL | QKZ | CHAR | 1 | 0 | Recording the Number of Defects | ||
| 75 | |
QLEITSTKZ | QKZ | CHAR | 1 | 0 | Control Characteristics Results - QM Subsystem | ||
| 76 | |
QVORGAEND | QKZ | CHAR | 1 | 0 | Specifications Can Be Changed | ||
| 77 | |
QPMZWANG | QKZ | CHAR | 1 | 0 | Assignment of Test Equipment Required | ||
| 78 | |
QFEHLREC | QKZ | CHAR | 1 | 0 | Defects Recording Automatically Called Up | ||
| 79 | |
QKZAENBEL | QKZ | CHAR | 1 | 0 | Create Change Documents During Results Recording | ||
| 80 | |
QSPCMK | QKZ | CHAR | 1 | 0 | SPC Characteristic | ||
| 81 | |
QDRUCK1 | QDRUCK1 | CHAR | 1 | 0 | |||
| 82 | |
QPARA | QKZ | CHAR | 1 | 0 | Control Indicator "Parameter Characteristic" Set/Not Set | ||
| 83 | |
QKZPROCCHAR | QKZ | CHAR | 1 | 0 | Process Characteristic | ||
| 84 | |
QTSTICHPRO | QKZUMFS | CHAR | 1 | 0 | Partial Samples Possible | ||
| 85 | |
QSOLLWERTC | QSOLLWERTC | CHAR | 16 | 0 | Target Value for a Quantitative Characteristic | ||
| 86 | |
QTOLOBC | QSOLLWERTC | CHAR | 16 | 0 | Upper Specification Limit | ||
| 87 | |
QTOLUNC | QSOLLWERTC | CHAR | 16 | 0 | Lower Specification Limit | ||
| 88 | |
QMITTEWRTC | QSTATWERTC | CHAR | 16 | 0 | Arithmetic Mean of Valid Measured Values | ||
| 89 | |
QSTDAWC | QSTATWERTC | CHAR | 16 | 0 | Standard Deviation of Valid Measured Values | ||
| 90 | |
QVARIANZC | QSTATWERTC | CHAR | 16 | 0 | Dispersion (Variance) of Valid Measured Values | ||
| 91 | |
QMAXWERTC | QSTATWERTC | CHAR | 16 | 0 | Maximum Value of the Valid Measured Values | ||
| 92 | |
QMINWERTC | QSTATWERTC | CHAR | 16 | 0 | Minimum Value of the Valid Measured Values | ||
| 93 | |
QANTEILOC | QSTATWERTC | CHAR | 16 | 0 | Estimated Fraction Above the Tolerance Range | ||
| 94 | |
QANTEILUC | QSTATWERTC | CHAR | 16 | 0 | Estimated Fraction Below the Tolerance Range | ||
| 95 | |
QCODETEXT | QTEXT80 | CHAR | 80 | 0 | Description of a Code in the Catalog | ||
| 96 | |
QMKKURZTXT | QKURZTEXT | CHAR | 40 | 0 | Short Text for the Inspection Characteristic | ||
| 97 | |
QMEAS_UNIT | TEXT6 | CHAR | 6 | 0 | Unit of Measurement (Internal Code) | ||
| 98 | |
QPRPLATZ | ARBPL | CHAR | 8 | 0 | Work Center | ||
| 99 | |
QZEITERSTL | QZEIT | TIMS | 6 | 0 | Time at which data record was created | ||
| 100 | |
QZEITAEND | QZEIT | TIMS | 6 | 0 | Time at which data record was last changed | ||
| 101 | |
0 | 0 | Evaluations: Fields Not Relevant for Characteristic Grouping | |||||
| 102 | |
QGEVAL_BATCH_HIERARCHY | QGEVAL_BATCH_HIERARCHY | CHAR | 30 | 0 | Batch Hierarchy | ||
| 103 | |
CHARG_D | CHARG | CHAR | 10 | 0 | Batch Number | * | |
| 104 | |
QGEVAL_TV_LIMITS_VIOLATED | QKZ | CHAR | 1 | 0 | Tolerance Limits Are Violated | ||
| 105 | |
QGEVAL_TV_ULIMITS_VIOLATED | QKZ | CHAR | 1 | 0 | Upper Tolerance Limit Is Violated | ||
| 106 | |
QGEVAL_TV_LLIMITS_VIOLATED | QKZ | CHAR | 1 | 0 | Lower Tolerance Limit Violated |
History
| Last changed by/on | SAP | 20130529 |
| SAP Release Created in | 700 |