Where Used List (Function Module) for SAP ABAP Data Element TPLNR (Functional Location)
SAP ABAP Data Element
TPLNR (Functional Location) is used by
pages: 1 2
# | Object Type | Object Name | Object Description | Package | Structure Package | Software Component |
---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |
||
1 | ![]() |
PM_HIERARCHY_CALL_BOM_IFLO VALUE(TPLNR) LIKE IFLO-TPLNR
|
Aufruf der Darstellung der Equipmentstückliste | ![]() |
![]() |
![]() |
2 | ![]() |
PM_HIERARCHY_CALL_BOM_RFC VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
RFC-Aufruf von Stücklisten für Material, Equi und TP | ![]() |
![]() |
![]() |
3 | ![]() |
PM_HIERARCHY_CALL_IFLO VALUE(TPLNR) LIKE IFLO-TPLNR
|
Aufruf der Hierarchiedarstellung für Technische Plätze | ![]() |
![]() |
![]() |
4 | ![]() |
PM_HIERARCHY_CALL_LIGHT REFERENCE(FUNCTIONAL_LOCATION) TYPE TPLNR OPTIONAL
|
Hierarchieauflösung (Objektschlüssel) | ![]() |
![]() |
![]() |
5 | ![]() |
PM_HIERARCHY_CALL_REMOTE
|
RFC: Lesen der Hierarchie eines Technischen Objektes | ![]() |
![]() |
![]() |
6 | ![]() |
PM_HIERARCHY_CALL_WITH_TABLE VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
Åufruf der Strukturdarstellung allgemein | ![]() |
![]() |
![]() |
7 | ![]() |
PM_IFLO_LIST VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
Platzliste (mehrstufig) | ![]() |
![]() |
![]() |
8 | ![]() |
PM_OBJECT_CHECK_AUTHORITY VALUE(I_TPLNR) LIKE IFLO-TPLNR
|
PM: Berechtigungsprüfung für das Bezugsobjekt | ![]() |
![]() |
![]() |
9 | ![]() |
PM_OBJECT_PREDECESSOR VALUE(E_TPLNR) LIKE RIWO1-TPLNR
|
Bestimmung des Objectvorgänge in Objekt-Subscreen | ![]() |
![]() |
![]() |
10 | ![]() |
PM_OBJECT_PREDECESSOR VALUE(I_TPLNR) LIKE RIWO1-TPLNR OPTIONAL
|
Bestimmung des Objectvorgänge in Objekt-Subscreen | ![]() |
![]() |
![]() |
11 | ![]() |
PM_OBJECT_RFC_ACTIVITY VALUE(NEW_TPLNR) LIKE IFLOT-TPLNR
|
Status für Instandhaltungsobjekt setzen | ![]() |
![]() |
![]() |
12 | ![]() |
PM_OBJECT_RFC_ACTIVITY VALUE(TPLNR) LIKE IFLO-TPLNR OPTIONAL
|
Status für Instandhaltungsobjekt setzen | ![]() |
![]() |
![]() |
13 | ![]() |
PM_OBJECT_SCREEN VALUE(TPLNR) LIKE IFLO-TPLNR
|
Allgemeinebearbeitung Objektbildbaustein | ![]() |
![]() |
![]() |
14 | ![]() |
PM_OBJECT_SCREEN VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
Allgemeinebearbeitung Objektbildbaustein | ![]() |
![]() |
![]() |
15 | ![]() |
PM_OBJECT_SELECTION VALUE(ETPLNR) LIKE RIWO1-TPLNR
|
Objectselektion über Strukturaufloesung | ![]() |
![]() |
![]() |
16 | ![]() |
PM_OBJECT_SELECTION VALUE(ITPLNR) LIKE RIWO1-TPLNR
|
Objectselektion über Strukturaufloesung | ![]() |
![]() |
![]() |
17 | ![]() |
PM_PARTNER_COMPLETE VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
Prüfen, ob sich Partner geändert hat | ![]() |
![]() |
![]() |
18 | ![]() |
PM_PARTNER_DATA_IMPORT VALUE(TPLNR) LIKE IFLO-TPLNR OPTIONAL
|
Import von Objektdaten in Partnerfunktionsgruppe | ![]() |
![]() |
![]() |
19 | ![]() |
PM_PARTNER_DETERMINE VALUE(TPLNR) LIKE IFLO-TPLNR
|
Partner von Bezugsobjekt bestimmen | ![]() |
![]() |
![]() |
20 | ![]() |
PM_PARTNER_DIALOG VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
Zentraler Aufruf des SD-Dialogbausteins für Partner | ![]() |
![]() |
![]() |
21 | ![]() |
PM_PARTNER_INIT VALUE(TPLNR) LIKE IFLO-TPLNR DEFAULT SPACE
|
Partnerverarbeitung initialisieren | ![]() |
![]() |
![]() |
22 | ![]() |
PM_PART_SELECTION VALUE(ITPLNR) LIKE RIWO1-TPLNR OPTIONAL
|
Baugruppenselektion über Strukturaufloesung | ![]() |
![]() |
![]() |
23 | ![]() |
PM_PREDECESSOR_EQUI VALUE(TPLNR) LIKE ILOA-TPLNR DEFAULT SPACE
|
Ermitteln Vorgänger zum Equipment | ![]() |
![]() |
![]() |
24 | ![]() |
PM_PREDECESSOR_EQUI_DIALOG VALUE(TPLNR) LIKE ILOA-TPLNR DEFAULT SPACE
|
Anzeige Dialogbox mit Vorgängern Equipment | ![]() |
![]() |
![]() |
25 | ![]() |
PM_PREDECESSOR_IFLO VALUE(TPLNR) LIKE IFLO-TPLNR
|
Ermitteln Vorgänger zum technischen Platz | ![]() |
![]() |
![]() |
26 | ![]() |
PM_PREDECESSOR_IFLO_DIALOG VALUE(TPLNR) LIKE IFLO-TPLNR
|
Anzeige Dialogbox mit Vorgängern Technischer Platz | ![]() |
![]() |
![]() |
27 | ![]() |
PM_PROOF_OBJECT_HIERARCHY VALUE(LTPLNR) LIKE RIWO1-TPLNR DEFAULT SPACE
|
Prüfen ob ein Object innerhabl der Struktur eines anderen Objektes liegt | ![]() |
![]() |
![]() |
28 | ![]() |
PM_PROOF_OBJECT_HIERARCHY VALUE(HTPLNR) LIKE RIWO1-TPLNR DEFAULT SPACE
|
Prüfen ob ein Object innerhabl der Struktur eines anderen Objektes liegt | ![]() |
![]() |
![]() |
29 | ![]() |
PM_PROOF_OBJECT_PART VALUE(ITPLNR) LIKE RIWO1-TPLNR OPTIONAL
|
Prüfen ob Baugruppe in Equistruktur vorhanden ist | ![]() |
![]() |
![]() |
30 | ![]() |
PM_ROUTINGS_SELECTION VALUE(I_TPLNR) LIKE IFLOT-TPLNR DEFAULT SPACE
|
PM Selektion von Arbeitsplänen/Anleitungen | ![]() |
![]() |
![]() |
31 | ![]() |
PM_SD_CONTRACT VALUE(TPLNR) LIKE VIQMEL-TPLNR DEFAULT SPACE
|
Reading contracts for equipment | ![]() |
![]() |
![]() |
32 | ![]() |
PM_SD_CONTRACT_CHECK VALUE(TPLNR) LIKE IFLO-TPLNR
|
PM_SD_CONTRACT_CHECK | ![]() |
![]() |
![]() |
33 | ![]() |
PM_SP_CALL_VB VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
Sichern der Genehmigungen | ![]() |
![]() |
![]() |
34 | ![]() |
PREPARE_IUID_HIERARCHY_DATA REFERENCE(IV_IFLO_NUMBER) TYPE IFLO-TPLNR
|
Prepare data for IUID hierarchy check | ![]() |
![]() |
![]() |
35 | ![]() |
QAPP_CUST_IP_PROPOSAL REFERENCE(E_TPLNR) LIKE QAPP-TPLNR
|
Default for Inspection Point Identification in Results Recording | ![]() |
![]() |
![]() |
36 | ![]() |
QELB_PM_OBJECT_SELECT VALUE(I_PM_OBJECT) LIKE IFLO-TPLNR OPTIONAL
|
Anzeigen aller (für das QM relevanten) Objekte zu einem PM-Auftrag | ![]() |
![]() |
![]() |
37 | ![]() |
QELB_PM_OBJECT_SELECT VALUE(E_PM_OBJECT) LIKE IFLO-TPLNR
|
Anzeigen aller (für das QM relevanten) Objekte zu einem PM-Auftrag | ![]() |
![]() |
![]() |
38 | ![]() |
QFDL_INIT_SELECTION_SCHEME VALUE(I_TPLNR) LIKE IFLOT-TPLNR
|
Read catalog profile for notifications | ![]() |
![]() |
![]() |
39 | ![]() |
QGMK_INSPECTION_HISTORY_QI VALUE(I_TPLNR) LIKE QAPP-TPLNR OPTIONAL
|
Anzeigen der Ergebnishistorie zum Merkmal | ![]() |
![]() |
![]() |
40 | ![]() |
QGMK_INSPECTION_HISTORY_SHOW VALUE(I_TPLNR) LIKE QAPP-TPLNR OPTIONAL
|
Anzeigen der Ergebnishistorie zum Merkmal | ![]() |
![]() |
![]() |
41 | ![]() |
QGMK_QAPP_OBJECT_SELECT VALUE(E_TPLNR) LIKE IFLOT-TPLNR
|
Selektion eines Equipments, Technischen Platzs oder einer Physischen Probe | ![]() |
![]() |
![]() |
42 | ![]() |
QIBP_INSPPOINT_QUERY REFERENCE(IV_FUNCT_LOC) TYPE TPLNR OPTIONAL
|
Prüfpunkte suchen | ![]() |
![]() |
![]() |
43 | ![]() |
QIBP_INSPPOINT_QUERY
|
Prüfpunkte suchen | ![]() |
![]() |
![]() |
44 | ![]() |
QNMA_46C_MYNOTIFICATIONS_ALM
|
MiniApp: myNotifications in PM/CS | ![]() |
![]() |
![]() |
45 | ![]() |
RECA_GUI_BUSOBJ_F4_FOR_OBJTYPE
|
F4-Hilfe zur Objektart | ![]() |
![]() |
![]() |
46 | ![]() |
REEX_FL_HAS_OBJASS REFERENCE(ID_TPLNR) TYPE TPLNR
|
Zuordnung TP zu RE-FX Objekt feststellen | ![]() |
![]() |
![]() |
47 | ![]() |
RFC_CHANGE_FUNC_LOC_MASTER VALUE(FUNCTIONAL_LOCATION) LIKE IFLO-TPLNR OPTIONAL
|
CAD/RFC change to a functional location master record | ![]() |
![]() |
![]() |
48 | ![]() |
RFC_CREATE_FUNC_LOC_MASTER VALUE(REF_FUNCTIONAL_LOCATION) LIKE IFLO-TPLNR OPTIONAL
|
CAD/RFC create functionalal location master record | ![]() |
![]() |
![]() |
49 | ![]() |
RFC_CREATE_FUNC_LOC_MASTER VALUE(EXP_FUNCTIONAL_LOCATION) LIKE IFLO-TPLNR
|
CAD/RFC create functionalal location master record | ![]() |
![]() |
![]() |
50 | ![]() |
RFC_CREATE_FUNC_LOC_MASTER VALUE(REF_REFERENCE_LOCATION) LIKE IFLO-TPLNR OPTIONAL
|
CAD/RFC create functionalal location master record | ![]() |
![]() |
![]() |
51 | ![]() |
RFC_CREATE_FUNC_LOC_MASTER VALUE(IMP_FUNCTIONAL_LOCATION) LIKE IFLO-TPLNR OPTIONAL
|
CAD/RFC create functionalal location master record | ![]() |
![]() |
![]() |
52 | ![]() |
RFC_CREATE_PM_ORDER VALUE(FUNCTIONAL_LOCATION) LIKE RIWO1-TPLNR OPTIONAL
|
CAD/RFC create maintenance order | ![]() |
![]() |
![]() |
53 | ![]() |
RFC_CREATE_PM_REQUEST_MASTER VALUE(FUNCTIONAL_LOCATION) LIKE RIWO1-TPLNR OPTIONAL
|
CAD/RFC create maintenance notification | ![]() |
![]() |
![]() |
54 | ![]() |
RFC_DISPLAY_FUNC_LOC_MASTER VALUE(FUNCTIONAL_LOCATION) LIKE IFLO-TPLNR OPTIONAL
|
CAD/RFC display functional location master record | ![]() |
![]() |
![]() |
55 | ![]() |
RFC_GET_FUNC_LOC_DATA VALUE(I_FUNC_LOC) LIKE IFLO-TPLNR
|
CAD/RFC read functional location data (IFLO + text) | ![]() |
![]() |
![]() |
56 | ![]() |
RPLM_MP_GET_DESCRIPTIONS REFERENCE(IV_FUNCLOC) TYPE TPLNR OPTIONAL
|
Gets descriptions | ![]() |
![]() |
![]() |
57 | ![]() |
RPLM_MP_GET_REF_FL REFERENCE(IV_FUNC_LOC) TYPE TPLNR
|
Returns Reference Functional Location | ![]() |
![]() |
![]() |
58 | ![]() |
RPLM_OBJ_HIST_ITM_DESC_FM REFERENCE(TPLNR) TYPE TPLNR
|
Fetches the Description Text | ![]() |
![]() |
![]() |
59 | ![]() |
SAMPLE_PROCESS_00700001 VALUE(C_TPLNR) LIKE IFLO-TPLNR OPTIONAL
|
Schnittstellenbeschreibung zu Prozess 00700001 | ![]() |
![]() |
![]() |
60 | ![]() |
SELECT_GRAPH_ADAPTER_FL_RFW VALUE(TPLNR) LIKE IFLO-TPLNR
|
Selektion einer Hierarchie technischer Plätze | ![]() |
![]() |
![]() |
61 | ![]() |
SET_EQUI_TO_EQUI_HIERARCHY VALUE(LOCATION) LIKE ILOA-TPLNR DEFAULT SPACE
|
Übergabe der Nummer des TechnPlatzes an Unterequipments | ![]() |
![]() |
![]() |
62 | ![]() |
SPECIALPER_ASSIGNMENT VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
Genehmigungsdialog | ![]() |
![]() |
![]() |
63 | ![]() |
STPE1_FUNCLOCAT_EXPORT VALUE(FUNCLOCAT) LIKE ILOA-TPLNR
|
Export eines Technischen Platzes | ![]() |
![]() |
![]() |
64 | ![]() |
TPLNR_GET_FOR_PLNNR VALUE(TPLNR_EXP) LIKE TAPL-TPLNR
|
TPLNR_GET_FOR_PLNNR | ![]() |
![]() |
![]() |
65 | ![]() |
VIEW_PM_FUNCLOC VALUE(X_TPLNR) TYPE IFLO-TPLNR
|
Die IL03 Transaktion wird angerufen | ![]() |
![]() |
![]() |
66 | ![]() |
WARRANTY_OBJEKT_GET REFERENCE(I_CAUFVD_TPLNR) LIKE CAUFVD-TPLNR OPTIONAL
|
Garantieprüfung Equipment/tech.Platz übernehmen | ![]() |
![]() |
![]() |
67 | ![]() |
WCFB_CHECK_ALL VALUE(I_TPLNR) TYPE TPLNR
|
WCM: I_IWERK, I_BEGRP, I_INGRP, I_SWERK, I_WCUSE, technical objects | ![]() |
![]() |
![]() |
68 | ![]() |
WCFG_AUTOMATICALLY_CREATE VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Automatisches Zuordnen von Genehmigungen | ![]() |
![]() |
![]() |
69 | ![]() |
WCFH_CREATE VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Erstellt die Objektliste | ![]() |
![]() |
![]() |
70 | ![]() |
WCFP_INSERT VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Schreibt den Eintrag (Bezugsobjekt) | ![]() |
![]() |
![]() |
71 | ![]() |
WCFW_CCOBJ_CHECK VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Prüfung für beide technischen Objekte | ![]() |
![]() |
![]() |
72 | ![]() |
WCFW_CCOBJ_INFO VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Liest die Information zu einem technischen Objekt | ![]() |
![]() |
![]() |
73 | ![]() |
WCFW_CCOBJ_OBJNR_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Bestimmt die Objektnummer des technischen Objekts | ![]() |
![]() |
![]() |
74 | ![]() |
WCFW_CCOBJ_SHOW
|
WCM: Technisches Objekt anzeigen | ![]() |
![]() |
![]() |
75 | ![]() |
WCFW_CCOBJ_SHOW VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Technisches Objekt anzeigen | ![]() |
![]() |
![]() |
76 | ![]() |
WCFW_CCTYP_GET VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Bestimmt den Typ des technischen Objekts | ![]() |
![]() |
![]() |
77 | ![]() |
WCFW_CHARACTERISTIC_ITEMS_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Klassifizierung auslesen | ![]() |
![]() |
![]() |
78 | ![]() |
WCFW_EQUIPMENT_INFO
|
WCM: Equipment und abhängige Information lesen | ![]() |
![]() |
![]() |
79 | ![]() |
WCFW_EQUIPMENT_USED_LIST
|
WCM: Verwendungsnachweis für das Equipment | ![]() |
![]() |
![]() |
80 | ![]() |
WCFW_FUNC_LOCATION_INFO VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Technischer Platz und abhängige Information lesen | ![]() |
![]() |
![]() |
81 | ![]() |
WCFW_FUNC_LOCATION_INFO VALUE(I_TPLNR_TMP) TYPE TPLNR OPTIONAL
|
WCM: Technischer Platz und abhängige Information lesen | ![]() |
![]() |
![]() |
82 | ![]() |
WCFW_FUNC_LOCATION_INFO VALUE(E_TPLNR_TMP) TYPE TPLNR
|
WCM: Technischer Platz und abhängige Information lesen | ![]() |
![]() |
![]() |
83 | ![]() |
WCFW_FUNC_LOCATION_USED_LIST VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Verwendungsnachweis für den Technischen Platz | ![]() |
![]() |
![]() |
84 | ![]() |
WCFW_IWERK_COMPARE VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Planungswerkvergleich | ![]() |
![]() |
![]() |
85 | ![]() |
WCFW_OBJNR_CCOBJ_GET
|
WCM: Bestimmt das technischen Objekt anhand der Objektnummer | ![]() |
![]() |
![]() |
86 | ![]() |
WCFW_PMOBJ_PREDECESSOR_SHOW VALUE(E_TPLNR) TYPE TPLNR
|
WCM: Vorgänger eines technischen Objekts anzeigen | ![]() |
![]() |
![]() |
87 | ![]() |
WCFW_PMOBJ_PREDECESSOR_SHOW VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Vorgänger eines technischen Objekts anzeigen | ![]() |
![]() |
![]() |
88 | ![]() |
WCFW_PMOBJ_STRUCTURE_LIST_SHOW
|
WCM: Strukturliste eines technischen Objekts anzeigen | ![]() |
![]() |
![]() |
89 | ![]() |
WCFW_PMOBJ_STRUCTURE_LIST_SHOW VALUE(E_TPLNR) TYPE TPLNR
|
WCM: Strukturliste eines technischen Objekts anzeigen | ![]() |
![]() |
![]() |
90 | ![]() |
WCFW_PMOBJ_STRUCTURE_LIST_SHOW VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Strukturliste eines technischen Objekts anzeigen | ![]() |
![]() |
![]() |
91 | ![]() |
WCGQ_LIST_EDITING_ICON_GET VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Ermittlung für die Listbearbeitung (Zusatzdaten) | ![]() |
![]() |
![]() |
92 | ![]() |
WCGQ_OBJLST_GET VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Ermittlung für die Objektliste | ![]() |
![]() |
![]() |
93 | ![]() |
WCGW_CCOBJ_DESCRIPTION_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Bestimmt die Beschreibung des technischen Objekts | ![]() |
![]() |
![]() |
94 | ![]() |
WCGW_CCOBJ_GET VALUE(I_TPLNR) TYPE TPLNR
|
WCM: E_CCOBJ, E_CCTYP <- I_MODE(I_TPLNR, I_EQUNR) | ![]() |
![]() |
![]() |
95 | ![]() |
WCGW_CCOBJ_IWERK_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Bestimmt das Planungswerk des technischen Objekts | ![]() |
![]() |
![]() |
96 | ![]() |
WCGW_FUNC_LOCATION_READ_SINGLE VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Stammdaten Technischer Platz lesen | ![]() |
![]() |
![]() |
97 | ![]() |
WCGW_LIST_FUNCTION_CHECK VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Überpüft ob eine Funktion ausgeführt werden darf | ![]() |
![]() |
![]() |
98 | ![]() |
WCGW_RIIFLO10_SUBMIT VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Technischer Platz (Strukturdarstellung) - IH01 | ![]() |
![]() |
![]() |
99 | ![]() |
WCGW_RIIFLO10_SUBMIT
|
WCM: Technischer Platz (Strukturdarstellung) - IH01 | ![]() |
![]() |
![]() |
100 | ![]() |
WCGW_TASK_LIST_TEMPLATES_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Ermittelt alle Vorlagen zum Arbeitsplan | ![]() |
![]() |
![]() |
101 | ![]() |
WCGW_TECHNICAL_OBJECT_GET VALUE(E_TPLNR) TYPE TPLNR
|
WCM: E_TPLNR, E_EQUNR <- INTERNAL( I_CCOBJ, I_CCTYP) | ![]() |
![]() |
![]() |
102 | ![]() |
WCGW_WAP_TEMPLATES_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Ermittelt alle Vorlagen zur Arbeitsgenehmigung | ![]() |
![]() |
![]() |
103 | ![]() |
WCGW_WCA_TEMPLATES_GET VALUE(I_TPLNR) TYPE TPLNR OPTIONAL
|
WCM: Ermittelt alle Vorlagen zur Freischaltanforderung | ![]() |
![]() |
![]() |
104 | ![]() |
WCGZ_TEMPLATE_SEARCH_REPLACE VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Ersetzt die Auswahl von Vorlagen zum Zuordnen | ![]() |
![]() |
![]() |
105 | ![]() |
WCHB_SUBSCR_BEFORE VALUE(I_TPLNR) TYPE TPLNR
|
WCM: Vorlagenverknüpfungen via Subscreen vorbereiten | ![]() |
![]() |
![]() |
106 | ![]() |
WPSTLH_CREATE_TASKLIST_DIALOG VALUE(E_TPLNR) LIKE RC27E-TPLNR
|
Create hier. tasklist-header with dialog | ![]() |
![]() |
![]() |
107 | ![]() |
WPSTLH_CREATE_TASKLIST_DIALOG VALUE(I_TPLNR) LIKE RC27E-TPLNR OPTIONAL
|
Create hier. tasklist-header with dialog | ![]() |
![]() |
![]() |
108 | ![]() |
WPSTLH_CREATE_TASKLIST_DOCTABS VALUE(I_TPLNR) TYPE RC27E-TPLNR OPTIONAL
|
Create task list in document tables | ![]() |
![]() |
![]() |
109 | ![]() |
WPSTS_GET_SUBORDINATE_TL_ALL REFERENCE(TPLNR) LIKE CAUFVD-TPLNR OPTIONAL
|
Alle untergeordneten Arbeitspläne ab Ausgangsknoten auflisten | ![]() |
![]() |
![]() |
110 | ![]() |
WPSTS_GET_SUBORD_TL_WPSTLH_ALL REFERENCE(TPLNR) LIKE CAUFVD-TPLNR OPTIONAL
|
Untergeord. Arbeitspläne ab einem Ausgangsknoten der Hierarchie auflisten | ![]() |
![]() |
![]() |
111 | ![]() |
WPSTS_TL_CONF_OBJECT_CREATE REFERENCE(TPLNR) LIKE CAUFVD-TPLNR OPTIONAL
|
(Temporäre) Konfiguration für Arbeitsplan anlegen | ![]() |
![]() |
![]() |
112 | ![]() |
WPSTS_TL_ORDER_GENER REFERENCE(TPLNR) LIKE CAUFVD-TPLNR OPTIONAL
|
Auftrag für (konfigurierten) Arbeitsplan generieren (ohne konfig. Obj.) | ![]() |
![]() |
![]() |
113 | ![]() |
WTY09_HIERACHY_OBJECT
|
Objekt in der Hierachie nach oben ermitteln | ![]() |
![]() |
![]() |
114 | ![]() |
WTY10_WEBUI_MWARRANTY_CHECK
|
Master warranty check for web interface | ![]() |
![]() |
![]() |