| 1 |
MANDT |
PLMK |
MANDT |
|
|
MANDT |
|
Client |
| 2 |
PLNTY |
PLMK |
PLNTY |
|
|
PLNTY |
|
Task List Type |
| 3 |
PLNNR |
PLMK |
PLNNR |
|
|
PLNNR |
|
Key for Task List Group |
| 4 |
PLNKN |
PLMK |
PLNKN |
|
|
PLNKN |
|
Number of the task list node |
| 5 |
KZEINSTELL |
PLMK |
KZEINSTELL |
|
|
QKZEINSTMK |
|
Characteristic Type |
| 6 |
MERKNR |
PLMK |
MERKNR |
|
|
QMERKNRP |
|
Inspection Characteristic Number |
| 7 |
ZAEHL |
PLMK |
ZAEHL |
|
|
CIM_COUNT |
|
Internal counter |
| 8 |
GUELTIGAB |
PLMK |
GUELTIGAB |
|
|
DATUV |
|
Valid-From Date |
| 9 |
SERNV |
PLMK |
SERNV |
|
|
TECHV |
|
Technical status from |
| 10 |
LOEKZ |
PLMK |
LOEKZ |
|
|
LKENZ |
|
Deletion Indicator |
| 11 |
PARKZ |
PLMK |
PARKZ |
|
|
PARKZ |
|
Indicator: inactive changes |
| 12 |
AENDERGNR |
PLMK |
AENDERGNR |
|
|
AENNR |
|
Change Number |
| 13 |
AENDERER |
PLMK |
AENDERER |
|
|
QAENDERER |
|
Name of User who Most Recently Changed the Data Record |
| 14 |
AENDERDAT |
PLMK |
AENDERDAT |
|
|
QDATUMAEND |
|
Date on Which Data Record Was Changed |
| 15 |
STEUERKZ |
PLMK |
STEUERKZ |
|
|
QMKCONTROL |
|
Cntrl Indicator String for Insp. Char./Master Insp. Char. |
| 16 |
QMTB_WERKS |
PLMK |
QMTB_WERKS |
|
|
Q_METH_PLANT |
|
Plant for Inspection Method |
| 17 |
PMETHODE |
PLMK |
PMETHODE |
|
|
QPMETHODE |
|
Inspection Method |
| 18 |
PMTVERSION |
PLMK |
PMTVERSION |
|
|
QVERSNRPM |
|
Version Number of the Inspection Method |
| 19 |
QPMK_REF |
PLMK |
QPMK_REF |
|
|
QKZ_REF |
|
Reference to Master Insp. Characteristic in Task List |
| 20 |
QPMK_ZAEHL |
PLMK |
QPMK_ZAEHL |
|
|
QZAEHLER |
|
Plant for the Master Inspection Characteristic |
| 21 |
VERWMERKM |
PLMK |
VERWMERKM |
|
|
QMERKNR |
|
Master Inspection Characteristics |
| 22 |
MKVERSION |
PLMK |
MKVERSION |
|
|
QVERSNRMK |
|
Version Number of the Master Inspection Characteristic |
| 23 |
MKVERSDAT |
PLMK |
MKVERSDAT |
|
|
QVERSDAT |
|
Key Date for Version Selection |
| 24 |
MERKGEW |
PLMK |
MERKGEW |
|
|
QMERKGEW |
|
Weighting of the Characteristic |
| 25 |
PROBENR |
PLMK |
PROBENR |
|
|
QPROBEPL |
|
Partial Sample No. for Inspection Charac. in Task List |
| 26 |
PRUEFQUALI |
PLMK |
PRUEFQUALI |
|
|
QPRQUALIF |
|
Inspector Qualification |
| 27 |
TOLERANZSL |
PLMK |
TOLERANZSL |
|
|
QTOLERANZ |
|
Tolerance Key |
| 28 |
KURZTEXT |
PLMK |
KURZTEXT |
|
|
QTXT_CHA |
|
Short Text for Inspection Characteristic |
| 29 |
LTEXTKZ |
PLMK |
LTEXTKZ |
|
|
QLTEXTKZ |
|
Inspection Characteristic Long Text Exists |
| 30 |
LTEXTSPR |
PLMK |
LTEXTSPR |
|
|
SPRAS |
|
Language Key |
| 31 |
LTEXTEKZ |
PLMK |
LTEXTEKZ |
|
|
QKZPRZIEH |
|
Physical-Sample-Drawing Text Exists |
| 32 |
LTXTENTSPR |
PLMK |
LTXTENTSPR |
|
|
SPRAS |
|
Language Key |
| 33 |
STELLEN |
PLMK |
STELLEN |
|
|
QSTELLEN |
|
Number of Places to the Right of a Decimal Point (Accuracy) |
| 34 |
MASSEINHSW |
PLMK |
MASSEINHSW |
|
|
QMASSEH |
|
Unit of Measurement, in Which Quantitative Data Is Stored |
| 35 |
SOLLWERT |
PLMK |
SOLLWERT |
|
|
QSOLLWERTE |
|
Target Value for a Quantitative Characteristic |
| 36 |
SOLLWNI |
PLMK |
SOLLWNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 37 |
TOLERANZOB |
PLMK |
TOLERANZOB |
|
|
QTOLOB |
|
Upper Specification Limit |
| 38 |
TOLOBNI |
PLMK |
TOLOBNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 39 |
TOLERANZUN |
PLMK |
TOLERANZUN |
|
|
QTOLUN |
|
Lower Tolerance Limit |
| 40 |
TOLUNNI |
PLMK |
TOLUNNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 41 |
KLASANZAHL |
PLMK |
KLASANZAHL |
|
|
QKLASSZAHL |
|
Number of Value Classes for Inspection Results |
| 42 |
KLASBREITE |
PLMK |
KLASBREITE |
|
|
QKLASSBR |
|
Class Width |
| 43 |
KLASBRNI |
PLMK |
KLASBRNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 44 |
KLASMITTE |
PLMK |
KLASMITTE |
|
|
QKLASSMIT |
|
Class Midpoint |
| 45 |
KLASMINI |
PLMK |
KLASMINI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 46 |
GRENZEOB1 |
PLMK |
GRENZEOB1 |
|
|
QGRENZOB1 |
|
First Upper Specification Limit |
| 47 |
GRENZOB1NI |
PLMK |
GRENZOB1NI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 48 |
GRENZEUN1 |
PLMK |
GRENZEUN1 |
|
|
QGRENZUN1 |
|
First Lower Specification Limit |
| 49 |
GRENZUN1NI |
PLMK |
GRENZUN1NI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 50 |
GRENZEOB2 |
PLMK |
GRENZEOB2 |
|
|
QGRENZOB2 |
|
Second Upper Specification Limit |
| 51 |
GRENZOB2NI |
PLMK |
GRENZOB2NI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 52 |
GRENZEUN2 |
PLMK |
GRENZEUN2 |
|
|
QGRENZUN2 |
|
Second Lower Specification Limit |
| 53 |
GRENZUN2NI |
PLMK |
GRENZUN2NI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 54 |
PLAUSIOBEN |
PLMK |
PLAUSIOBEN |
|
|
QPLAUSIOB |
|
Upper Plausibility Limit |
| 55 |
PLAUSIOBNI |
PLMK |
PLAUSIOBNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 56 |
PLAUSIUNTE |
PLMK |
PLAUSIUNTE |
|
|
QPLAUSIUN |
|
Lower Plausibility Limit |
| 57 |
PLAUSIUNNI |
PLMK |
PLAUSIUNNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 58 |
TOLERWEIOB |
PLMK |
TOLERWEIOB |
|
|
QTOLWOB |
|
Change to Upper Specification Limit |
| 59 |
TOLWOBNI |
PLMK |
TOLWOBNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 60 |
TOLERWEIUN |
PLMK |
TOLERWEIUN |
|
|
QTOLWUN |
|
Change to Lower Specification Limit |
| 61 |
TOLWUNNI |
PLMK |
TOLWUNNI |
|
|
QNINITIAL |
|
Value Not Initial if Set |
| 62 |
TOLERWAB |
PLMK |
TOLERWAB |
|
|
QTOLWAB |
|
Date from Which the Tolerance Change Is Valid |
| 63 |
TOLERWBIS |
PLMK |
TOLERWBIS |
|
|
QTOLWBIS |
|
Date Until Which the Tolerance Change Is Valid |
| 64 |
STICHPRVER |
PLMK |
STICHPRVER |
|
|
QSTICHVERF |
|
Sampling Procedure in Inspection Characteristic |
| 65 |
FAKPLANME |
PLMK |
FAKPLANME |
|
|
QUMREN |
|
Factor for Converting MatUnitOfMeasure to SampUnitOfMeasure |
| 66 |
FAKPROBME |
PLMK |
FAKPROBME |
|
|
QUMRENPME |
|
Factor for Converting SampUnitOfMeasure to MatUnitOfMeasure |
| 67 |
PROBEMGEH |
PLMK |
PROBEMGEH |
|
|
QPROBME |
|
Sample Unit of Measure |
| 68 |
PRUEFEINH |
PLMK |
PRUEFEINH |
|
|
QPROBEFAK |
|
Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.) |
| 69 |
DYNKRIT |
PLMK |
DYNKRIT |
|
|
QDYNSTRING |
|
String for Dynamic Modification Criteria (Database Relevant) |
| 70 |
FORMELSL |
PLMK |
FORMELSL |
|
|
QFORMELSL |
|
Check and Calculate Formula in QM |
| 71 |
FORMEL1 |
PLMK |
FORMEL1 |
|
|
QFORMEL |
|
Formula Field |
| 72 |
FORMEL2 |
PLMK |
FORMEL2 |
|
|
QFORMEL |
|
Formula Field |
| 73 |
CODEGR9U |
PLMK |
CODEGR9U |
|
|
QCODEGRPU |
|
Defect Code Group for Rejection at Lower Tolerance |
| 74 |
CODE9U |
PLMK |
CODE9U |
|
|
QCODEU |
|
Defect Code for Rejection at Lower Specification Limit |
| 75 |
CODEVR9U |
PLMK |
CODEVR9U |
|
|
QVERSNR |
|
Version Number |
| 76 |
CODEGR9O |
PLMK |
CODEGR9O |
|
|
QCODEGRPO |
|
Defect Code Group for Rejection at Upper Tolerance |
| 77 |
CODE9O |
PLMK |
CODE9O |
|
|
QCODEO |
|
Defect Code for Rejection at Upper Specification Limit |
| 78 |
CODEVR9O |
PLMK |
CODEVR9O |
|
|
QVERSNR |
|
Version Number |
| 79 |
DUMMY10 |
PLMK |
DUMMY10 |
|
|
QTXT10 |
|
Text Line for Additional Information |
| 80 |
DUMMY20 |
PLMK |
DUMMY20 |
|
|
QTXT20 |
|
Text Line for Additional Information |
| 81 |
DUMMY40 |
PLMK |
DUMMY40 |
|
|
QTXT40 |
|
Text Line for Additional Information |
| 82 |
EEANTVERF |
PLMK |
EEANTVERF |
|
|
QEANTVERF |
|
Fraction Calculation |
| |
|
|
|
|
|
|
|
|