SAP ABAP Table REG30_AUTO_ZW_MOD (Automation Data for Modification of Registers in Inst./Rep.)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷ IS-U-DM-DI (Application Component) Device installation
⤷ EE07 (Package) IS-U: Installation, Removal and Replacement of Devices
⤷ IS-U-DM-DI (Application Component) Device installation
⤷ EE07 (Package) IS-U: Installation, Removal and Replacement of Devices
Basic Data
Table Category | INTTAB | Structure |
Structure | REG30_AUTO_ZW_MOD | Table Relationship Diagram |
Short Description | Automation Data for Modification of Registers in Inst./Rep. |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|
---|---|---|---|---|---|---|---|---|---|
1 | .INCLUDE | 0 | 0 | Screen Fields (New Device): Inst./Removal/Repl./Terminate | |||||
2 | ZWNUMMERE | E_ZWNUMMER | LFDNR3 | NUMC | 3 | 0 | Register | ||
3 | ABLSTATE | ABLSTAT | ABLSTAT | CHAR | 1 | 0 | Meter Reading Status | ||
4 | MESSDRCKE | MESSDRCK | MESSDRCK | DEC | 7 | 4 | Measured Pressure (Outlet Pressure) in Bars | * | |
5 | .INCLUDE | 0 | 0 | Register Data for EG30 - EG36 (New Device) | |||||
6 | ERFASSNACE | E_RUNDUNG | E_RUNDUNG | CHAR | 2 | 0 | Starting Point for Rounding | ||
7 | GERAETE | GERNR | GERNR | CHAR | 18 | 0 | Serial Number | ||
8 | EQUNRE | EQUNR | EQUNR | CHAR | 18 | 0 | Equipment Number | * | |
9 | MATNRE | MATNR | MATNR | CHAR | 18 | 0 | Material Number | * | |
10 | PROGTE | PROGT | PROGT | CHAR | 6 | 0 | ARCR Command | * | |
11 | LOGIKZWE | LOGIKZW | LOGIKZW | NUMC | 18 | 0 | Logical register number | ||
12 | METERDOCE | KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
13 | PERVERBRE | KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
14 | FIRST_ALLOC | KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
15 | .INCLUDE | 0 | 0 | Input Fields (New Device): Inst./Rem./Repl./Terminate | |||||
16 | KONDIGRE | KONDIGR | KONDIGR | CHAR | 10 | 0 | Rate fact group | * | |
17 | ZWSTANDCE | E_ZWSTAND | E_ZWSTAND | CHAR | 36 | 0 | Meter reading recorded | ||
18 | THGVER | THGVER | THGVER | CHAR | 8 | 0 | Gas procedure | * | |
19 | FESTTEMP | FESTTEMP | FESTTEMP | CHAR | 8 | 0 | Fixed temperature | TE551 | |
20 | ZUSZAHLZWE | E_ZUSZAHLZW | E_ZUSZAHL | DEC | 9 | 6 | Volume correction factor | ||
21 | STEUERGRPE | STEUERGRP | STEUERGRP | CHAR | 4 | 0 | Control group for multiple meter reading order creation | * | |
22 | PROFESTE | PROFEST | PROFEST | DEC | 7 | 3 | Consumption fixed value to be weighted linearly | ||
23 | PROPROZE | PROPROZ | PRZ32 | DEC | 5 | 2 | Consumption percentage for weighting | ||
24 | ZEITRAUME | E_ZEITRAUM | E_ZEITRAUM | CHAR | 8 | 0 | Validity period | ||
25 | RABZUSE | RABZUS | RABZUS | CHAR | 10 | 0 | Discount key | * | |
26 | ANZERG | ANZERG | ANZAHLENT | DEC | 2 | 0 | Number of meter reading results per meter reading | ||
27 | ZWNABR | E_ZWNABR | KENNZX | CHAR | 1 | 0 | Register not relevant to billing | ||
28 | PREISKLAE | PREISKLA | PREISKLA | CHAR | 10 | 0 | Price Class | TE431 | |
29 | TARIFART | TARIFART | TARIFART | CHAR | 8 | 0 | Rate Type | TE069 | |
30 | ANZDAYSOFPERIOD | ADOFPER | ADOFPER | NUMC | 3 | 0 | Number of days period consumption is valid | ||
31 | PERVERBR | PERVERBRD | CHAR14 | CHAR | 14 | 0 | Period Consumption | ||
32 | GVERRECH | GVERRECH | GVERRECH | CHAR | 1 | 0 | Pay rental price | ||
33 | KENNZIFFE | KENNZIFF | CHAR15 | CHAR | 15 | 0 | Code for Identifying a Register | TEKENNZIFF | |
34 | ZWZUORD | E_ZWNUMMER | LFDNR3 | NUMC | 3 | 0 | Register | ||
35 | TEMP_AREA | TEMP_AREA | TEMP_AREA | CHAR | 8 | 0 | Temperature area | TE307 | |
36 | PR_AREA_AI | PR_AREA_AI | PR_AREA_AI | CHAR | 8 | 0 | Air pressure area | TE309 | |
37 | CALOR_AREA | CALOR_AREA | CALOR_AREA | CHAR | 8 | 0 | Calorific value district | TE453 | |
38 | HOEKORR | HOEKORR | HOEKORR | DEC | 7 | 5 | Altitude correction pressure | ||
39 | KZAHLE | KZAHLE | KZAHL | DEC | 7 | 5 | Gas law deviation factor (set) | ||
40 | KZAHLT | KZAHLT | KZAHL | DEC | 7 | 5 | Actual gas law deviation factor | ||
41 | GAS_PRS_AR | GAS_PRS_AR | GAS_PRS_AR | CHAR | 8 | 0 | Gas Pressure Area | TE343 | |
42 | CRGPRESS | CRGPRESS | CRGPRESS | DEC | 7 | 4 | Gas correction pressure | ||
43 | ABRFAKTE | ABRFAKT | ABRFAKT | DEC | 12 | 5 | Billing factor | ||
44 | NABLESENE | E_NABLESEN | KENNZX | CHAR | 1 | 0 | Do Not Read Register | ||
45 | MASSBILLE | E_MASSBILL | MEINS | UNIT | 3 | 0 | Unit of measurement for billing | T006 | |
46 | GEWKEYE | GEWKEY | GEWKEY | CHAR | 8 | 0 | Weighting key | TE266 | |
47 | PRUEFKLE | PRUEFKL | PRUEFKL | CHAR | 4 | 0 | Validation class for independent validations | TE408 | |
48 | .INCLUDE | 0 | 0 | Screen fields for virtual device input | |||||
49 | SPARTYPE | SPARTYP | SPARTYP | NUMC | 2 | 0 | Division category | ||
50 | ZWTYPE | E_ZWTYP | E_ZWTYP | NUMC | 2 | 0 | Register category | ||
51 | BLIWIRKE | BLIWIRK | BLIWIRK | NUMC | 2 | 0 | Reactive, apparent, or active registers | ||
52 | ZWARTE | E_ZWART | E_ZWART | CHAR | 2 | 0 | Register type | TE523 | |
53 | ZWKENNE | E_ZWKENN | E_ZWKENN | CHAR | 2 | 0 | Register identification | TE065 | |
54 | THGBERE | THGBER | THGBER | CHAR | 2 | 0 | Inclusion of factors in thermal gas billing | ||
55 | MEINS | MEINS_ISU | MSEC6 | CHAR | 6 | 0 | Unit of measurement for meter reading | * | |
56 | INTSIZEIDE | INTSIZEID | INTSIZEID | CHAR | 4 | 0 | Interval Length ID | EPROFINTSIZE | |
57 | MASSREADE | E_MASSREAD | MEINS | UNIT | 3 | 0 | Unit of measurement for meter reading | * | |
58 | KZMESSWE | KZMESSW | KENNZX | CHAR | 1 | 0 | Nonmetering register | ||
59 | STANZVORE | STANZVOR | STANZVOR | NUMC | 2 | 0 | Places before the decimal point in a register | ||
60 | STANZNACE | STANZNAC | STANZNAC | NUMC | 2 | 0 | Places after the decimal in a register | ||
61 | UEBERVERE | UEBERVER | UEBERV | DEC | 10 | 3 | Transformation ratio | ||
62 | ZWFAKTE | E_ZWFAKT | E_ZWFAKT | DEC | 12 | 5 | Register factor | ||
63 | ZSPANNSE | E_ZSPANNS | SPANNUNG | DEC | 4 | 1 | Register factor: secondary transformer voltage | ||
64 | ZSTROMSE | E_ZSTROMS | E_ZSTROMS | DEC | 5 | 2 | Register factor: secondary transformer current | ||
65 | ZSPANNPE | E_ZSPANNP | WSPANNP | DEC | 6 | 0 | Register factor: primary transformer voltage | ||
66 | ZSTROMPE | E_ZSTROMP | E_ZSTROMP | DEC | 5 | 1 | Register factor: primary transformer current | ||
67 | MASSBILLC6E | MASSBILLC6 | MSEC6 | CHAR | 6 | 0 | Unit of measurement for billing | * | |
68 | TOUPERIODE | E_TOUPERIOD | E_TOUPERIOD | CHAR | 10 | 0 | Time-of-use type | ETOU | |
69 | ZWNSETTLE | E_ZWNSETTL | KENNZX | CHAR | 1 | 0 | Register not relevant to settlement | ||
70 | DO_NOT_USE | DO_NOT_USE_ZW | KENNZX | CHAR | 1 | 0 | Do not use register |
Foreign Keys
Source Table | Source Column | Foreign Table | Foreign Column | Dependency Factor | Cardinality left | Cardinality right | |
---|---|---|---|---|---|---|---|
1 | REG30_AUTO_ZW_MOD | CALOR_AREA | TE453 | CALOR_AREA | |||
2 | REG30_AUTO_ZW_MOD | FESTTEMP | TE551 | FESTTEMP | |||
3 | REG30_AUTO_ZW_MOD | GAS_PRS_AR | TE343 | GAS_PRS_AR | |||
4 | REG30_AUTO_ZW_MOD | GEWKEYE | TE266 | GEWKEY | |||
5 | REG30_AUTO_ZW_MOD | INTSIZEIDE | EPROFINTSIZE | INTSIZEID | |||
6 | REG30_AUTO_ZW_MOD | KENNZIFFE | TEKENNZIFF | KENNZIFF | KEY | 1 | CN |
7 | REG30_AUTO_ZW_MOD | MASSBILLE | T006 | MSEHI | |||
8 | REG30_AUTO_ZW_MOD | PREISKLAE | TE431 | PREISKLA | |||
9 | REG30_AUTO_ZW_MOD | PRUEFKLE | TE408 | PRUEFKL | |||
10 | REG30_AUTO_ZW_MOD | PR_AREA_AI | TE309 | PR_AREA_AI | |||
11 | REG30_AUTO_ZW_MOD | TARIFART | TE069 | TARIFART | |||
12 | REG30_AUTO_ZW_MOD | TEMP_AREA | TE307 | TEMP_AREA | |||
13 | REG30_AUTO_ZW_MOD | TOUPERIODE | ETOU | TOUPERIOD | 1 | CN | |
14 | REG30_AUTO_ZW_MOD | ZWARTE | TE523 | ZWART | |||
15 | REG30_AUTO_ZW_MOD | ZWKENNE | TE065 | ZWKENN |
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in |