Hierarchy
⤷ IS-U-DM-DI (Application Component) Device installation
⤷ EE07 (Package) IS-U: Installation, Removal and Replacement of Devices
Basic Data
Data Element | E_ZWNABR |
Short Description | Register not relevant to billing |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | KENNZX | |
Data Type | CHAR | Character String |
Length | 1 | |
Decimal Places | 0 | |
Output Length | 1 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | ||
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | Not relev. |
Medium | 15 | No billing |
Long | 20 | Not rel. to billing |
Heading | 15 | No billing |
Documentation
Definition
Means that the meter reading of this register is not relevant for billing.
For all registers except resetting registers, this field and the rate type can be combined as follows:
- Field selected, rate type specified
The register is read as if the field had not been selected. The result from a control meter, for example, can be used for checking readings entry. However, such meter readings are not processed during billing:
- During billing, rate determination is not carried out for the rate type of the register. The rate of the register is not billed unless it is determined via another billing-relevant register.
- The register readings cannot be printed on the bill.
- A rental price is not charged for the register.
This does not apply to registers switched in series. When primary meters are billed, consumption from all registers is processed. Meter readings from secondary meters are therefore also processed during billing if the indicator is set.
- Field selected, rate type not specified
The register is not billed.
- Field not selected, rate type specified
The register must be read so that it can be used for billing. In this case, therefore, the Do not read field must not be selected. Otherwise an error occurs during billing. If the meter reading is only to be taken in order to display the meter reading result on the bill, then at least one variant must be entered in the rate found via the rate type. This variant writes one info line for each meter reading result.
- Field not selected, rate type not specified
This combination produces an error in billing because every register relevant for billing must have a rate type.
Dependencies
- The N (register not relevant for billing) field is only effective when the Do not read (do not read register) field is not selected.
- If the N (register not relevant for billing) field is selected for all registers and no rate type is specified in the installation or rate category facts, billing is terminated as no rate is found.
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in |