SAP ABAP Data Element E_ZWTYP (Register category)
Hierarchy
IS-UT (Software Component) SAP Utilities/Telecommunication
   IS-U-DM (Application Component) Device Management
     EE10 (Package) IS-U: Device Management
Basic Data
Data Element E_ZWTYP
Short Description Register category  
Data Type
Category of Dictionary Type D   Domain
Type of Object Referenced     No Information
Domain / Name of Reference Type E_ZWTYP    
Data Type NUMC   Character string with only digits 
Length 2    
Decimal Places 0    
Output Length 2    
Value Table      
Further Characteristics
Search Help: Name    
Search Help: Parameters    
Parameter ID   
Default Component name    
Change document    
No Input History    
Basic direction is set to LTR    
No BIDI Filtering    
Field Label
  Length  Field Label  
Short 10 Reg. cat. 
Medium 15 Register categ. 
Long 20 Register category 
Heading RC 
Documentation

Definition

You can use the following register categories:

  • Cumulative wattregister

    The difference between the current meter reading and the previous meter reading forms the basis for determining the demand. The difference between the meter readings for the beginning and the end of the base period forms the basis for determining the expected demand.

  • Balancing watt register

    This category is also known as a maximum or demand register. This register category is reset after meter reading has taken place. The current meter reading is the starting point for determining the demand. The meter reading for the end of the base period forms the basis for determining the expected demand.

  • Resetting register

    This register counts the number of resettings of a maximum or demand register. These meter readings are not billed. The required meter reading is determined by adding the number of expected meter reading results to the last billed meter reading.

  • Balancing consumption register

    The current meter reading forms the basis for determining the consumption. The meter reading for the end of the base period forms the basis for calculating the expected consumption in the forecast period.

  • Cumulative consumption register

    The difference between the current meter reading and the previous meter reading forms the basis for determining consumption. The difference between the meter readings for the end and beginning of the base period forms the basis for calculating the expected consumption in the forecast period.

  • Other register

    These registers (such as time meters) are not relevant to billing. All registers not to be allocated to any of the above register categories can be placed into this category. You can enter a description of the register category in the information field.

History
Last changed by/on SAP  20050224 
SAP Release Created in