SAP ABAP Table ISU_MR_DOC_ATTR (Attribute Structure for IsuMReadDoc)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷
IS-U-DM-MR (Application Component) Meter Reading
⤷
EE17 (Package) IS-U: Meter Reading Data Entry

⤷

⤷

Basic Data
Table Category | INTTAB | Structure |
Structure | ISU_MR_DOC_ATTR |
![]() |
Short Description | Attribute Structure for IsuMReadDoc |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
![]() |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ABLBELNR | ABLBELNR | CHAR | 20 | 0 | Internal ID for meter reading document | * | |
2 | ![]() |
GERAET | GERNR | CHAR | 18 | 0 | Device | ||
3 | ![]() |
EQUNR | EQUNR | CHAR | 18 | 0 | Equipment Number | * | |
4 | ![]() |
STANZVORE | STANZVOR | NUMC | 2 | 0 | Number of predecimal places for register | ||
5 | ![]() |
STANZNACE | STANZNAC | NUMC | 2 | 0 | Number of decimal places for register | ||
6 | ![]() |
E_ZWNUMMER | LFDNR3 | NUMC | 3 | 0 | Register | ||
7 | ![]() |
E_ZWSTAND | E_ZWSTAND | CHAR | 36 | 0 | Meter reading recorded | ||
8 | ![]() |
ADAT | DATUM | DATS | 8 | 0 | Meter reading date relevant to billing | ||
9 | ![]() |
ATIM | HHMM | CHAR | 4 | 0 | Meter reading time (relevant to billing) | ||
10 | ![]() |
E_MASSREAD | MEINS | UNIT | 3 | 0 | Unit of measurement for meter reading | * | |
11 | ![]() |
ADATSOLL | DATUM | DATS | 8 | 0 | Scheduled meter reading date | ||
12 | ![]() |
ADATMAX | DATUM | DATS | 8 | 0 | Date of maximum meter reading | ||
13 | ![]() |
ATIMMAX | HHMM | CHAR | 4 | 0 | Time of maximum meter reading | ||
14 | ![]() |
ADATTATS | DATUM | DATS | 8 | 0 | Actual meter reading date | ||
15 | ![]() |
ATIMTATS | HHMM | CHAR | 4 | 0 | Actual meter reading time | ||
16 | ![]() |
ABLSTAT | ABLSTAT | CHAR | 1 | 0 | Meter Reading Status | ||
17 | ![]() |
E_AKTIV | E_AKTIV | CHAR | 1 | 0 | Meter reading active | ||
18 | ![]() |
ABLHINW | ABLHINW | CHAR | 4 | 0 | Note from meter reader | * | |
19 | ![]() |
ABLHINW_TEXT | CHAR50 | CHAR | 50 | 0 | Text for Meter Reading Note | ||
20 | ![]() |
STABLHW | STABLHW | CHAR | 2 | 0 | Control of follow-up action for MR result with MR note | ||
21 | ![]() |
ISTABLART | ISTABLART | CHAR | 2 | 0 | Meter reading type | * | |
22 | ![]() |
ISTABLART_TEXT | CHAR40 | CHAR | 40 | 0 | Text for User-Defined Meter Reading Type for Entry | ||
23 | ![]() |
ABLESTYP | ABLESETYP | CHAR | 2 | 0 | Meter reading category | * | |
24 | ![]() |
PRUEFPKT | PRUEFPKT | CHAR | 2 | 0 | Independent validation | * | |
25 | ![]() |
PRFPKT_TXT | CHAR40 | CHAR | 40 | 0 | Independent validation (not passed) | ||
26 | ![]() |
POPCODE | POPCODE | CHAR | 2 | 0 | Dependent validation | * | |
27 | ![]() |
ABLESGR | ABLESGR | CHAR | 2 | 0 | Meter reading reason | * | |
28 | ![]() |
E_ZWTYP | E_ZWTYP | NUMC | 2 | 0 | Register category | ||
29 | ![]() |
E_ZWTYP_TEXT | CHAR50 | CHAR | 50 | 0 | Text for Register Category | ||
30 | ![]() |
E_ZWART | E_ZWART | CHAR | 2 | 0 | Register type | * | |
31 | ![]() |
E_ZWART_TEXT | CHAR30 | CHAR | 30 | 0 | Text for Register Type | ||
32 | ![]() |
E_ZWKENN | E_ZWKENN | CHAR | 2 | 0 | Register identification | * | |
33 | ![]() |
KENNZIFF | CHAR15 | CHAR | 15 | 0 | Code for Identifying a Register | ||
34 | ![]() |
SPARTE | SPART | CHAR | 2 | 0 | Division | * | |
35 | ![]() |
E_SPARTE_TEXT | CHAR20 | CHAR | 20 | 0 | Division Text | ||
36 | ![]() |
SPARTYP | SPARTYP | NUMC | 2 | 0 | Division category | ||
37 | ![]() |
E_SPARTYP_TEXT | CHAR20 | CHAR | 20 | 0 | Text for Division Category | ||
38 | ![]() |
VERTRAG | VERTRAG | CHAR | 10 | 0 | Contract | * | |
39 | ![]() |
ANLAGE | ANLAGE | CHAR | 10 | 0 | Installation | * | |
40 | ![]() |
ABLBELNR | ABLBELNR | CHAR | 20 | 0 | Internal ID for meter reading document | * | |
41 | ![]() |
E_ZWSTANDPREV | E_ZWSTAND | CHAR | 36 | 0 | Previous Meter Reading Result of Register | ||
42 | ![]() |
ADATPREV | DATUM | DATS | 8 | 0 | Date of Previous Meter Reading for Register | ||
43 | ![]() |
ATIMPREV | HHMM | CHAR | 4 | 0 | Meter Reading Time of Previous Meter Reading for Register | ||
44 | ![]() |
ABLSTAT | ABLSTAT | CHAR | 1 | 0 | Meter Reading Status | ||
45 | ![]() |
ISTABLART | ISTABLART | CHAR | 2 | 0 | Meter reading type | * | |
46 | ![]() |
ISTABLART_TEXT | CHAR40 | CHAR | 40 | 0 | Text for User-Defined Meter Reading Type for Entry | ||
47 | ![]() |
CONSMPT | E_VERBR | CHAR | 36 | 0 | Consumption | ||
48 | ![]() |
CONSMPT_EX | E_VERBR | CHAR | 36 | 0 | Expected consumption | ||
49 | ![]() |
CSMPT_MIN | E_VERBR | CHAR | 36 | 0 | Minimum (permitted) expected consumption | ||
50 | ![]() |
CSMPT_MAX | E_VERBR | CHAR | 36 | 0 | Maximum (permitted) expected consumption | ||
51 | ![]() |
E_ZWSTD_EX | E_ZWSTAND | CHAR | 36 | 0 | Expected meter reading | ||
52 | ![]() |
MR_MIN | E_ZWSTAND | CHAR | 36 | 0 | Minimum expected meter reading | ||
53 | ![]() |
MR_MAX | E_ZWSTAND | CHAR | 36 | 0 | Maximum expected meter reading | ||
54 | ![]() |
KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
55 | ![]() |
FIELD | FIELD | CHAR | 10 | 0 | Field | ||
56 | ![]() |
KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
57 | ![]() |
ICON_D | ICON | CHAR | 4 | 0 | Icon in text fields (substitute display, alias) | * | |
58 | ![]() |
VSTELLE | VSTELLE | CHAR | 10 | 0 | Premise | * | |
59 | ![]() |
LINES | LINES | CHAR | 80 | 0 | Address line | ||
60 | ![]() |
KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
61 | ![]() |
KENNZX | KENNZX | CHAR | 1 | 0 | Indicators | ||
62 | ![]() |
KENNZX | KENNZX | CHAR | 1 | 0 | Indicators |
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in | 472 |