Hierarchy
⤷ IS-U-DM (Application Component) Device Management
⤷ EE10 (Package) IS-U: Device Management
Basic Data
Data Element | UEBERVER |
Short Description | Transformation ratio |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | UEBERV | |
Data Type | DEC | Counter or amount field with comma and sign |
Length | 10 | |
Decimal Places | 3 | |
Output Length | 13 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | ||
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | Tran.ratio |
Medium | 15 | Transform.ratio |
Long | 20 | Transformation ratio |
Heading | 13 | Trans. ratio |
Documentation
Definition
The transformation ratio specifies the conversion factor used by the register to which a transformer is connnected.
The transformation ratio can be specified for the device category, for the device, and for register. The transformation ratio for the register overwrites the ratio for the device and the ratio for the device overwrites the ratio for the device category.
The transformation ratio can only be specified if the measuring type of the device category is 1 or 2 (i.e. for semi-indirect or indirect measuring).
The billing factor is calculated in conjunction with the transformer factor of the connected transformer. The following formula is used:
Billing factor = transformer factor / transformation ratio.
It is also possible to specify the transformation ratio by specifying the primary or secondary voltage or current. In this case the transformation ratio is calculated and cannot be overwritten.
The ratio is calculated as follows:
primary voltage primary current
Transformation ratio = ________________ * ______________
secondary voltage secondary current
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in |