SAP ABAP Table ISU_WA_ROUTING_S_CONTAINER (Container at Container Location)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷
IS-U-WA (Application Component) Waste Management
⤷
EEWA (Package) IS-U: Waste Management

⤷

⤷

Basic Data
Table Category | INTTAB | Structure |
Structure | ISU_WA_ROUTING_S_CONTAINER |
![]() |
Short Description | Container at Container Location |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
![]() |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
V_EGER | STRU | 0 | 0 | ||||
2 | ![]() |
MANDT | MANDT | CLNT | 3 | 0 | Client | ||
3 | ![]() |
EQUNR | EQUNR | CHAR | 18 | 0 | Equipment Number | ||
4 | ![]() |
BISZEITSCH | DATUM | DATS | 8 | 0 | Date at Which a Time Slice Expires | ||
5 | ![]() |
ABZEITSCH | DATUM | DATS | 8 | 0 | Date from which time slice is valid | ||
6 | ![]() |
LOGIKNR | LOGIKNR | NUMC | 18 | 0 | Logical device number | ||
7 | ![]() |
GERNR | GERNR | CHAR | 18 | 0 | Serial Number | ||
8 | ![]() |
MATNR | MATNR | CHAR | 18 | 0 | Material Number | ||
9 | ![]() |
WERKS_D | WERKS | CHAR | 4 | 0 | Plant | ||
10 | ![]() |
LGORT_D | LGORT | CHAR | 4 | 0 | Storage location | ||
11 | ![]() |
E_ZWGRUPPE | GEGST | CHAR | 8 | 0 | Register Group | ||
12 | ![]() |
EINBDAT | DATUM | DATS | 8 | 0 | Installation date | ||
13 | ![]() |
AUSBDAT | DATUM | DATS | 8 | 0 | Device removal date | ||
14 | ![]() |
GERWECHS | GERWECHS | CHAR | 2 | 0 | Activity reason | ||
15 | ![]() |
DEVLOC | TPLNR | CHAR | 30 | 0 | Device Location | ||
16 | ![]() |
WGRUPPE | GEGST | CHAR | 8 | 0 | Winding group | ||
17 | ![]() |
PRIMWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active primary winding | ||
18 | ![]() |
SEKWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active secondary winding | ||
19 | ![]() |
PRIMWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active primary winding | ||
20 | ![]() |
SEKWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active secondary winding | ||
21 | ![]() |
EAGRUPPE | GEGST | CHAR | 8 | 0 | Input/output group | ||
22 | ![]() |
KOMGRP | GEGST | CHAR | 8 | 0 | ARCR Command Group | ||
23 | ![]() |
LOS | GEGST | CHAR | 8 | 0 | Sample lot | ||
24 | ![]() |
MESSDRCK | MESSDRCK | DEC | 7 | 4 | Measured Pressure (Outlet Pressure) in Bars | ||
25 | ![]() |
UEBERVER | UEBERV | DEC | 10 | 3 | Transformation ratio | ||
26 | ![]() |
BESITZ | BESITZ | NUMC | 2 | 0 | Inspection relevance of device | ||
27 | ![]() |
BGLJAHR | JAHR | NUMC | 4 | 0 | Certification Year | ||
28 | ![]() |
WECHSEL | JAHR | NUMC | 4 | 0 | Advance replacement year | ||
29 | ![]() |
BGLSTAT | BGLSTAT | CHAR | 1 | 0 | Certification status | ||
30 | ![]() |
KZSTICH | KZSTICH | CHAR | 1 | 0 | Status of sample device | ||
31 | ![]() |
SCHWGRAD | DEC2_1 | DEC | 3 | 1 | Difficulty level: Factor for meter reader payment | ||
32 | ![]() |
PLOMBDAT | DATUM | DATS | 8 | 0 | Date of last lead sealing | ||
33 | ![]() |
HERST | TEXT30 | CHAR | 30 | 0 | Manufacturer of asset | ||
34 | ![]() |
BGLART | BGLART | CHAR | 2 | 0 | Type of certification | ||
35 | ![]() |
BGLNUM | CHAR15 | CHAR | 15 | 0 | Certification number | ||
36 | ![]() |
UMBAUDAT | DATUM | DATS | 8 | 0 | Modification date | ||
37 | ![]() |
UMBAUGR | UMBAUGR | CHAR | 2 | 0 | Modification reason | ||
38 | ![]() |
EICHFAEL | KENNZX | CHAR | 1 | 0 | Use calibration validity | ||
39 | ![]() |
PARAMETR | PARAMETR | CHAR | 8 | 0 | Parametrization | ||
40 | ![]() |
PLOMBE | PLOMBE | CHAR | 2 | 0 | Seal code | ||
41 | ![]() |
ERDAT | DATUM | DATS | 8 | 0 | Date on which the record was created | ||
42 | ![]() |
ERNAM | USNAM | CHAR | 12 | 0 | Name of Person who Created the Object | ||
43 | ![]() |
AEDAT | DATUM | DATS | 8 | 0 | Last Changed On | ||
44 | ![]() |
AENAM | USNAM | CHAR | 12 | 0 | Name of Person Who Changed Object | ||
45 | ![]() |
E_ZSPANNS | SPANNUNG | DEC | 4 | 1 | Register factor: secondary transformer voltage | ||
46 | ![]() |
E_ZSPANNP | WSPANNP | DEC | 6 | 0 | Register factor: primary transformer voltage | ||
47 | ![]() |
E_ZSTROMS | E_ZSTROMS | DEC | 5 | 2 | Register factor: secondary transformer current | ||
48 | ![]() |
E_ZSTROMP | E_ZSTROMP | DEC | 5 | 1 | Register factor: primary transformer current | ||
49 | ![]() |
BAUJJ | CJAHR | CHAR | 4 | 0 | Year of construction | ||
50 | ![]() |
DEVGRP | DEVGRP | CHAR | 8 | 0 | Device group | ||
51 | ![]() |
SPARTE | SPART | CHAR | 2 | 0 | Division | ||
52 | ![]() |
TYPBZ | TYPBZ | CHAR | 20 | 0 | Manufacturer model number | ||
53 | ![]() |
APPROVALNR | CHAR15 | CHAR | 15 | 0 | Device inspection number | ||
54 | ![]() |
VLZEIT_DEV | ALLGVLZEIT | DEC | 2 | 0 | Individual cal. validity (years) of dev. subject to certif. | ||
55 | ![]() |
KOMBINAT | KOMBINAT | CHAR | 8 | 0 | Combination of a device category | ||
56 | ![]() |
BGLNETZ | KENNZX | CHAR | 1 | 0 | Certify installed devices | ||
57 | ![]() |
ORDERCODE2 | CHAR004 | CHAR | 4 | 0 | Special Order Code for Dev./Dev. Category in Replacement | ||
58 | ![]() |
NOTIF_CODE | CHAR004 | CHAR | 4 | 0 | Notification code | ||
59 | ![]() |
KZEQBS | KZEQBS | CHAR | 1 | 0 | EQSI Exists | ||
60 | ![]() |
PPM_METER | PPM_METER | NUMC | 2 | 0 | Prepayment Meter | ||
61 | ![]() |
J_OBJNR | J_OBJNR | CHAR | 22 | 0 | Object number | ||
62 | ![]() |
EGPL | STRU | 0 | 0 | ||||
63 | ![]() |
0 | 0 | Device Location | |||||
64 | ![]() |
MANDT | MANDT | CLNT | 3 | 0 | Client | ||
65 | ![]() |
DEVLOC | TPLNR | CHAR | 30 | 0 | Device Location | ||
66 | ![]() |
SPRAS | SPRAS | LANG | 1 | 0 | Language Key | ||
67 | ![]() |
PLTXT | TEXT40 | CHAR | 40 | 0 | Description of functional location | ||
68 | ![]() |
KZLTX | XFELD | CHAR | 1 | 0 | Indicator: More long text exists | ||
69 | ![]() |
TPLKZ | TPLKZ | CHAR | 5 | 0 | Functional location structure indicators | ||
70 | ![]() |
FLTYP | FLTYP | CHAR | 1 | 0 | Functional Location Category | ||
71 | ![]() |
HAUS | TPLNR | CHAR | 30 | 0 | Connection Object | ||
72 | ![]() |
DATAB | DATUM | DATS | 8 | 0 | Valid-From Date | ||
73 | ![]() |
IAUTG | IAUTG | CHAR | 4 | 0 | Authorization Group for Technical Object | ||
74 | ![]() |
INH_BEGRUI | INHER | CHAR | 1 | 0 | Data origin for authorization group field | ||
75 | ![]() |
IWERK | WERKS | CHAR | 4 | 0 | Maintenance Planning Plant | ||
76 | ![]() |
INH_IWERKI | INHER | CHAR | 1 | 0 | Data origin for planning plant field | ||
77 | ![]() |
ILOM_POSNR | CHAR4 | CHAR | 4 | 0 | Position in superior technical object | ||
78 | ![]() |
ILOM_ISTYP | ILOM_ISTYP | CHAR | 1 | 0 | Object category for Industry Solutions (IS) | ||
79 | ![]() |
VSTELLE | VSTELLE | CHAR | 10 | 0 | Premise | ||
80 | ![]() |
SWERK | WERKS | CHAR | 4 | 0 | Maintenance Plant | ||
81 | ![]() |
INH_SWERKI | INHER | CHAR | 1 | 0 | Data origin for maintenance plant field | ||
82 | ![]() |
BUKRS | BUKRS | CHAR | 4 | 0 | Company Code | ||
83 | ![]() |
INH_BUKRSI | INHER | CHAR | 1 | 0 | Data origin for company code field | ||
84 | ![]() |
AD_ADDRNUM | AD_ADDRNUM | CHAR | 10 | 0 | Address number | ||
85 | ![]() |
INH_ADRNRI | INHER | CHAR | 1 | 0 | Data origin for address field | ||
86 | ![]() |
PMLOC | AP_STAND | CHAR | 10 | 0 | Location of maintenance object | ||
87 | ![]() |
INH_STORTI | INHER | CHAR | 1 | 0 | Data origin for location field | ||
88 | ![]() |
STORTZUS | TEXT30 | CHAR | 30 | 0 | Addition to device location | ||
89 | ![]() |
ILOAN | ILOAN | CHAR | 12 | 0 | Location and account assignment for technical object | ||
90 | ![]() |
J_OBJNR | J_OBJNR | CHAR | 22 | 0 | Object number | ||
91 | ![]() |
IEQUI | X | CHAR | 1 | 0 | Installation of equipment allowed at the functional location | ||
92 | ![]() |
INH_IEQUII | INHER | CHAR | 1 | 0 | Data origin for equip. inst. allowed field | ||
93 | ![]() |
ICRDT | DATUM | DATS | 8 | 0 | Date on Which Object Was Created | ||
94 | ![]() |
ICRNA | USNAM | CHAR | 12 | 0 | Name of User Who Created the Object | ||
95 | ![]() |
IUPDT | DATUM | DATS | 8 | 0 | Date on which the object was last changed | ||
96 | ![]() |
IUPNA | USNAM | CHAR | 12 | 0 | Name of the User Who Last Changed the Object | ||
97 | ![]() |
GP_STRNO | ILOM_STRNO | CHAR | 40 | 0 | Device Location Identification | ||
98 | ![]() |
0 | 0 | ||||||
99 | ![]() |
EHAU | STRU | 0 | 0 | ||||
100 | ![]() |
0 | 0 | Connection Object Without Customer Include | |||||
101 | ![]() |
MANDT | MANDT | CLNT | 3 | 0 | Client | ||
102 | ![]() |
HAUS | TPLNR | CHAR | 30 | 0 | Connection Object | ||
103 | ![]() |
SPRAS | SPRAS | LANG | 1 | 0 | Language Key | ||
104 | ![]() |
PLTXT | TEXT40 | CHAR | 40 | 0 | Description of functional location | ||
105 | ![]() |
KZLTX | XFELD | CHAR | 1 | 0 | Indicator: More long text exists | ||
106 | ![]() |
TPLKZ | TPLKZ | CHAR | 5 | 0 | Functional location structure indicators | ||
107 | ![]() |
FLTYP | FLTYP | CHAR | 1 | 0 | Functional Location Category | ||
108 | ![]() |
TPLMA | TPLNR | CHAR | 30 | 0 | Superior functional location | ||
109 | ![]() |
DATAB | DATUM | DATS | 8 | 0 | Valid-From Date | ||
110 | ![]() |
IAUTG | IAUTG | CHAR | 4 | 0 | Authorization Group for Technical Object | ||
111 | ![]() |
INH_BEGRUI | INHER | CHAR | 1 | 0 | Data origin for authorization group field | ||
112 | ![]() |
IWERK | WERKS | CHAR | 4 | 0 | Maintenance Planning Plant | ||
113 | ![]() |
INH_IWERKI | INHER | CHAR | 1 | 0 | Data origin for planning plant field | ||
114 | ![]() |
ILOM_POSNR | CHAR4 | CHAR | 4 | 0 | Position in superior technical object | ||
115 | ![]() |
ILOM_ISTYP | ILOM_ISTYP | CHAR | 1 | 0 | Object category for Industry Solutions (IS) | ||
116 | ![]() |
ILOM_PREMS | CHAR10 | CHAR | 10 | 0 | Premise | ||
117 | ![]() |
EQFNR | CHAR30 | CHAR | 30 | 0 | Sort Field | ||
118 | ![]() |
SWERK | WERKS | CHAR | 4 | 0 | Maintenance Plant | ||
119 | ![]() |
INH_SWERKI | INHER | CHAR | 1 | 0 | Data origin for maintenance plant field | ||
120 | ![]() |
BUKRS | BUKRS | CHAR | 4 | 0 | Company Code | ||
121 | ![]() |
INH_BUKRSI | INHER | CHAR | 1 | 0 | Data origin for company code field | ||
122 | ![]() |
AD_ADDRNUM | AD_ADDRNUM | CHAR | 10 | 0 | Address number | ||
123 | ![]() |
INH_ADRNRI | INHER | CHAR | 1 | 0 | Data origin for address field | ||
124 | ![]() |
LVORM | XFELD | CHAR | 1 | 0 | Deletion Indicator | ||
125 | ![]() |
ILOAN | ILOAN | CHAR | 12 | 0 | Location and account assignment for technical object | ||
126 | ![]() |
IEQUI | X | CHAR | 1 | 0 | Installation of equipment allowed at the functional location | ||
127 | ![]() |
INH_IEQUII | INHER | CHAR | 1 | 0 | Data origin for equip. inst. allowed field | ||
128 | ![]() |
COUNC | COUNC | CHAR | 3 | 0 | County Code | ||
129 | ![]() |
REGIOGROUP | REGIOGROUP | CHAR | 8 | 0 | Regional structure grouping | ||
130 | ![]() |
REGPOLIT | REGPOLIT | CHAR | 8 | 0 | Political regional structure element | ||
131 | ![]() |
REGIOGROUP_PERMIT | REGIOGROUP | CHAR | 8 | 0 | Regional structure group for supply permit processing | ||
132 | ![]() |
J_OBJNR | J_OBJNR | CHAR | 22 | 0 | Object number | ||
133 | ![]() |
ICRDT | DATUM | DATS | 8 | 0 | Date on Which Object Was Created | ||
134 | ![]() |
ICRNA | USNAM | CHAR | 12 | 0 | Name of User Who Created the Object | ||
135 | ![]() |
IUPDT | DATUM | DATS | 8 | 0 | Date on which the object was last changed | ||
136 | ![]() |
IUPNA | USNAM | CHAR | 12 | 0 | Name of the User Who Last Changed the Object | ||
137 | ![]() |
EHAU_GUID | SYSUUID | RAW | 16 | 0 | CRM GUID of Connection Object | ||
138 | ![]() |
AO_STRNO | ILOM_STRNO | CHAR | 40 | 0 | Connection Object Identification | ||
139 | ![]() |
0 | 0 | ||||||
140 | ![]() |
EADRDAT | STRU | 0 | 0 | ||||
141 | ![]() |
0 | 0 | Address return structure | |||||
142 | ![]() |
0 | 0 | Address selection parameter | |||||
143 | ![]() |
AD_ADDRNUM | AD_ADDRNUM | CHAR | 10 | 0 | Address number | ||
144 | ![]() |
AD_HANDLE | TEXT140 | CHAR | 140 | 0 | Handle for Creating Addresses/Persons (Bus. Addr. Services) | ||
145 | ![]() |
AD_NATION | AD_NATION | CHAR | 1 | 0 | Version ID for International Addresses | ||
146 | ![]() |
AD_DATE | DATUM | DATS | 8 | 0 | Date referred to | ||
147 | ![]() |
0 | 0 | Address transfer structure | |||||
148 | ![]() |
AD_DATE_FR | DATUM | DATS | 8 | 0 | Valid-from date - in current Release only 00010101 possible | ||
149 | ![]() |
AD_DATE_TO | DATUM | DATS | 8 | 0 | Valid-to date in current Release only 99991231 possible | ||
150 | ![]() |
0 | 0 | Include structure with name attributes of the ADRC address | |||||
151 | ![]() |
AD_TITLE | AD_TITLE | CHAR | 4 | 0 | Form-of-Address Key | ||
152 | ![]() |
AD_NAME1 | TEXT40 | CHAR | 40 | 0 | Name 1 | ||
153 | ![]() |
AD_NAME2 | TEXT40 | CHAR | 40 | 0 | Name 2 | ||
154 | ![]() |
AD_NAME3 | TEXT40 | CHAR | 40 | 0 | Name 3 | ||
155 | ![]() |
AD_NAME4 | TEXT40 | CHAR | 40 | 0 | Name 4 | ||
156 | ![]() |
AD_NAMETXT | TEXT50 | CHAR | 50 | 0 | Converted name field (with form of address) | ||
157 | ![]() |
0 | 0 | Include structure with ADRC attributes without name fields | |||||
158 | ![]() |
AD_NAME_CO | TEXT40 | CHAR | 40 | 0 | c/o name | ||
159 | ![]() |
AD_CITY1 | TEXT40 | CHAR | 40 | 0 | City | ||
160 | ![]() |
AD_CITY2 | TEXT40 | CHAR | 40 | 0 | District | ||
161 | ![]() |
AD_CITYNUM | CITY_CODE | CHAR | 12 | 0 | City code for city/street file | ||
162 | ![]() |
AD_CITYPNM | CITYP_CODE | CHAR | 8 | 0 | District code for City and Street file | ||
163 | ![]() |
AD_CITY3 | TEXT40 | CHAR | 40 | 0 | City (different from postal city) | ||
164 | ![]() |
AD_CITYHNM | CITY_CODE | CHAR | 12 | 0 | Different city for city/street file | ||
165 | ![]() |
AD_CHECKST | AD_CHECKST | CHAR | 1 | 0 | City file test status | ||
166 | ![]() |
REGIOGROUP | REGIOGROUP | CHAR | 8 | 0 | Regional structure grouping | ||
167 | ![]() |
AD_PSTCD1 | CHAR10 | CHAR | 10 | 0 | City postal code | ||
168 | ![]() |
AD_PSTCD2 | CHAR10 | CHAR | 10 | 0 | PO Box postal code | ||
169 | ![]() |
AD_PSTCD3 | CHAR10 | CHAR | 10 | 0 | Company postal code (for large customers) | ||
170 | ![]() |
AD_PST1XT | CHAR10 | CHAR | 10 | 0 | (Not Supported)City Postal Code Extension, e.g. ZIP+4+2 Code | ||
171 | ![]() |
AD_PST2XT | CHAR10 | CHAR | 10 | 0 | (Not Supported) PO Box Postal Code Extension | ||
172 | ![]() |
AD_PST3XT | CHAR10 | CHAR | 10 | 0 | (Not Supported) Major Customer Postal Code Extension | ||
173 | ![]() |
AD_POBX | CHAR10 | CHAR | 10 | 0 | PO Box | ||
174 | ![]() |
AD_NO_USEP | AD_NO_USE | CHAR | 4 | 0 | PO Box Address Undeliverable Flag | ||
175 | ![]() |
AD_POBXNUM | XFELD | CHAR | 1 | 0 | Flag: PO Box without number | ||
176 | ![]() |
AD_POBXLOC | TEXT40 | CHAR | 40 | 0 | PO Box city | ||
177 | ![]() |
AD_CIT2NUM | CITY_CODE | CHAR | 12 | 0 | City PO box code (City file) | ||
178 | ![]() |
AD_POBXREG | REGIO | CHAR | 3 | 0 | Region for PO Box (Country, State, Province, ...) | ||
179 | ![]() |
AD_POBXCTY | LAND1 | CHAR | 3 | 0 | PO box country | ||
180 | ![]() |
AD_PSTLAR | TEXT15 | CHAR | 15 | 0 | (Not Supported) Post Delivery District | ||
181 | ![]() |
LZONE | ZONE | CHAR | 10 | 0 | Transportation zone to or from which the goods are delivered | ||
182 | ![]() |
AD_STREET | TEXT60 | CHAR | 60 | 0 | Street | ||
183 | ![]() |
AD_NO_USES | AD_NO_USE | CHAR | 4 | 0 | Street Address Undeliverable Flag | ||
184 | ![]() |
AD_STRNUM | STRT_CODE | CHAR | 12 | 0 | Street Number for City/Street File | ||
185 | ![]() |
AD_STRABBR | STRTYPEAB | CHAR | 2 | 0 | (Not Supported) Abbreviation of Street Name | ||
186 | ![]() |
AD_HSNM1 | TEXT10 | CHAR | 10 | 0 | House Number | ||
187 | ![]() |
AD_HSNM2 | TEXT10 | CHAR | 10 | 0 | House number supplement | ||
188 | ![]() |
AD_HSNM3 | TEXT10 | CHAR | 10 | 0 | (Not supported) House Number Range | ||
189 | ![]() |
AD_STRSPP1 | TEXT40 | CHAR | 40 | 0 | Street 2 | ||
190 | ![]() |
AD_STRSPP2 | TEXT40 | CHAR | 40 | 0 | Street 3 | ||
191 | ![]() |
AD_STRSPP3 | TEXT40 | CHAR | 40 | 0 | Street 4 | ||
192 | ![]() |
AD_LCTN | TEXT40 | CHAR | 40 | 0 | Street 5 | ||
193 | ![]() |
AD_BLDNG | TEXT20 | CHAR | 20 | 0 | Building (Number or Code) | ||
194 | ![]() |
AD_FLOOR | TEXT10 | CHAR | 10 | 0 | Floor in building | ||
195 | ![]() |
AD_ROOMNUM | TEXT10 | CHAR | 10 | 0 | Room or Appartment Number | ||
196 | ![]() |
LAND1 | LAND1 | CHAR | 3 | 0 | Country Key | ||
197 | ![]() |
SPRAS | SPRAS | LANG | 1 | 0 | Language Key | ||
198 | ![]() |
REGIO | REGIO | CHAR | 3 | 0 | Region (State, Province, County) | ||
199 | ![]() |
AD_SORT1UL | TEXT20 | CHAR | 20 | 0 | Search Term 1 | ||
200 | ![]() |
AD_SORT2UL | TEXT20 | CHAR | 20 | 0 | Search Term 2 | ||
201 | ![]() |
AD_SRTPHN | CHAR20 | CHAR | 20 | 0 | (Not Supported) Phonetic Search Sort Field | ||
202 | ![]() |
AD_ORIGINA | AD_ORIGIN | CHAR | 4 | 0 | (Not Supported) Address Data Source (Key) | ||
203 | ![]() |
AD_EXTENS1 | TEXT40 | CHAR | 40 | 0 | Extension (only for data conversion) (e.g. data line) | ||
204 | ![]() |
AD_EXTENS2 | TEXT40 | CHAR | 40 | 0 | Extension (only for data conversion) (e.g. telebox) | ||
205 | ![]() |
AD_TZONE | TZNZONE | CHAR | 6 | 0 | Address time zone | ||
206 | ![]() |
AD_TXJCD | AD_TXJCD | CHAR | 15 | 0 | Tax Jurisdiction | ||
207 | ![]() |
AD_ADDR_ID | AD_ADDR_ID | CHAR | 10 | 0 | (Not supported) Physical address ID | ||
208 | ![]() |
AD_REMARK1 | TEXT50 | CHAR | 50 | 0 | Address notes | ||
209 | ![]() |
AD_LANGUCR | SPRAS | LANG | 1 | 0 | Address record creation original language | ||
210 | ![]() |
AD_PO_BOX_LBY | TEXT40 | CHAR | 40 | 0 | PO Box Lobby | ||
211 | ![]() |
AD_DELIVERY_SERVICE_TYPE | AD_DELIVERY_SERVICE_TYPE | CHAR | 4 | 0 | Type of Delivery Service | ||
212 | ![]() |
AD_DELIVERY_SERVICE_NUMBER | CHAR10 | CHAR | 10 | 0 | Number of Delivery Service | ||
213 | ![]() |
AD_CNTYNUM | CNTY_CODE | CHAR | 8 | 0 | County code for county | ||
214 | ![]() |
AD_COUNTY | TEXT40 | CHAR | 40 | 0 | County | ||
215 | ![]() |
AD_TWSHPNUM | TWSHP_CODE | CHAR | 8 | 0 | Township code for Township | ||
216 | ![]() |
AD_TOWNSHIP | TEXT40 | CHAR | 40 | 0 | Township | ||
217 | ![]() |
AD_COMM | AD_COMM | CHAR | 3 | 0 | Communication Method (Key) (Business Address Services) | ||
218 | ![]() |
AD_TLNMBR1 | CHAR30 | CHAR | 30 | 0 | First telephone no.: dialling code+number | ||
219 | ![]() |
AD_TLXTNS1 | CHAR10 | CHAR | 10 | 0 | First Telephone No.: Extension | ||
220 | ![]() |
AD_FXNMBR1 | CHAR30 | CHAR | 30 | 0 | First fax no.: dialling code+number | ||
221 | ![]() |
AD_FXXTNS1 | CHAR10 | CHAR | 10 | 0 | First fax no.: extension | ||
222 | ![]() |
AD_GROUP | AD_GROUP | CHAR | 4 | 0 | Address Group (Key) (Business Address Services) | ||
223 | ![]() |
SPRAS | SPRAS | LANG | 1 | 0 | Language Key | ||
224 | ![]() |
LGZUSATZ | LGZUSATZ | CHAR | 40 | 0 | Additional Information on Location | ||
225 | ![]() |
AD_STRSPP2 | TEXT40 | CHAR | 40 | 0 | Street 3 | ||
226 | ![]() |
AD_LCTN | TEXT40 | CHAR | 40 | 0 | Street 5 | ||
227 | ![]() |
AD_HSNM2 | TEXT10 | CHAR | 10 | 0 | House number supplement | ||
228 | ![]() |
AD_FLOOR | TEXT10 | CHAR | 10 | 0 | Floor in building | ||
229 | ![]() |
AD_ROOMNUM | TEXT10 | CHAR | 10 | 0 | Room or Appartment Number | ||
230 | ![]() |
PMLOC | AP_STAND | CHAR | 10 | 0 | Location of maintenance object | ||
231 | ![]() |
LAGETEXT | TEXT40 | CHAR | 40 | 0 | Text for location | ||
232 | ![]() |
STORTZUS | TEXT30 | CHAR | 30 | 0 | Addition to device location | ||
233 | ![]() |
AD_TITLETX | TEXT30 | CHAR | 30 | 0 | Title text | ||
234 | ![]() |
ISU_WA_ROUTING_T_SERV_SHARE | TTYP | 0 | 0 |
History
Last changed by/on | SAP | 20130529 |
SAP Release Created in | 471 |