SAP ABAP Table REG42_DEV_INPUT (Device Mod.: Input Data at Device level)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷ IS-U-DM-DI (Application Component) Device installation
⤷ EE07 (Package) IS-U: Installation, Removal and Replacement of Devices
⤷ IS-U-DM-DI (Application Component) Device installation
⤷ EE07 (Package) IS-U: Installation, Removal and Replacement of Devices
Basic Data
Table Category | INTTAB | Structure |
Structure | REG42_DEV_INPUT | Table Relationship Diagram |
Short Description | Device Mod.: Input Data at Device level |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|
---|---|---|---|---|---|---|---|---|---|
1 | EAGRUPPE | EAGRUPPE | GEGST | CHAR | 8 | 0 | Input/output group | ||
2 | KOMGRP | KOMGRP | GEGST | CHAR | 8 | 0 | ARCR Command Group | ||
3 | MESSDRCK | MESSDRCK | MESSDRCK | DEC | 7 | 4 | Measured Pressure (Outlet Pressure) in Bars | * | |
4 | UEBERVER | UEBERVER | UEBERV | DEC | 10 | 3 | Transformation ratio | ||
5 | PLOMBDAT | PLOMBDAT | DATUM | DATS | 8 | 0 | Date of last lead sealing | ||
6 | HERST | HERST | TEXT30 | CHAR | 30 | 0 | Manufacturer of asset | ||
7 | BGLNUM | BGLNUM | CHAR15 | CHAR | 15 | 0 | Certification number | ||
8 | UMBAUGR | UMBAUGR | UMBAUGR | CHAR | 2 | 0 | Modification reason | TE791 | |
9 | PARAMETR | PARAMETR | PARAMETR | CHAR | 8 | 0 | Parametrization | TE927 | |
10 | PLOMBE | PLOMBE | PLOMBE | CHAR | 2 | 0 | Seal code | TE937 | |
11 | TYPBZ | TYPBZ | TYPBZ | CHAR | 20 | 0 | Manufacturer model number | ||
12 | .INCLUDE | 0 | 0 | Factors in Register | |||||
13 | ZSPANNS | E_ZSPANNS | SPANNUNG | DEC | 4 | 1 | Register factor: secondary transformer voltage | ||
14 | ZSTROMS | E_ZSTROMS | E_ZSTROMS | DEC | 5 | 2 | Register factor: secondary transformer current | ||
15 | ZSPANNP | E_ZSPANNP | WSPANNP | DEC | 6 | 0 | Register factor: primary transformer voltage | ||
16 | ZSTROMP | E_ZSTROMP | E_ZSTROMP | DEC | 5 | 1 | Register factor: primary transformer current | ||
17 | .INCLUDE | 0 | 0 | Device Mod.: Input Data at Device level | |||||
18 | ZWGRUPPE | E_ZWGRUPPE | GEGST | CHAR | 8 | 0 | Register Group | ||
19 | WGRUPPE | WGRUPPE | GEGST | CHAR | 8 | 0 | Winding group | ||
20 | PRIMWNR1 | PRIMWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active primary winding | ||
21 | SEKWNR1 | SEKWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active secondary winding | ||
22 | PRIMWNR2 | PRIMWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active primary winding | ||
23 | SEKWNR2 | SEKWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active secondary winding | ||
24 | SERVICE_PROV | EGERR_SERVICE_PROV | SERVICE_PROV | CHAR | 10 | 0 | Service Provider for Device Info Record | * | |
25 | EGERR_INFO | EGERR_INFO | TEXT30 | CHAR | 30 | 0 | Information Field of Device Info Record | ||
26 | PPM_METER | PPM_METER | PPM_METER | NUMC | 2 | 0 | Prepayment Meter | TEPPM | |
27 | .INCLUDE | 0 | 0 |
Foreign Keys
Source Table | Source Column | Foreign Table | Foreign Column | Dependency Factor | Cardinality left | Cardinality right | |
---|---|---|---|---|---|---|---|
1 | REG42_DEV_INPUT | PARAMETR | TE927 | PARAMETR | |||
2 | REG42_DEV_INPUT | PLOMBE | TE937 | PLOMBE | KEY | C | CN |
3 | REG42_DEV_INPUT | PPM_METER | TEPPM | PPM_METER | KEY | C | CN |
4 | REG42_DEV_INPUT | UMBAUGR | TE791 | UMBAUGR |
History
Last changed by/on | SAP | 20050411 |
SAP Release Created in |