Data Element list used by SAP ABAP Table BIW_ISU_DEVICE_I (BW Extract Structure for IS-U Device)
SAP ABAP Table
BIW_ISU_DEVICE_I (BW Extract Structure for IS-U Device) is using
| # | Object Type | Object Name | Object Description | Note |
|---|---|---|---|---|
| 1 | ABZEITSCH | Date from which time slice is valid | ||
| 2 | AD_ADDRNUM | Address number | ||
| 3 | AD_CITYNUM | City code for city/street file | ||
| 4 | AD_CITYPNM | District code for City and Street file | ||
| 5 | AD_STRNUM | Street Number for City/Street File | ||
| 6 | APPROVALNR | Device inspection number | ||
| 7 | AUSBDAT | Device removal date | ||
| 8 | BAUJJ | Year of construction | ||
| 9 | BESITZ | Inspection relevance of device | ||
| 10 | BGLART | Type of certification | ||
| 11 | BGLBIS | Next replacement year | ||
| 12 | BGLJAHR | Certification Year | ||
| 13 | BGLKENN | Determination of dev.req.planning/rep.yr from certification | ||
| 14 | BGLNETZ | Certify installed devices | ||
| 15 | BGLNUM | Certification number | ||
| 16 | BGLSTAT | Certification status | ||
| 17 | BISZEITSCH | Date at Which a Time Slice Expires | ||
| 18 | DEVGRP | Device group | ||
| 19 | DEVLOC | Device Location | ||
| 20 | EAGRUPPE | Input/output group | ||
| 21 | EICHFAEL | Use calibration validity | ||
| 22 | EINBDAT | Installation date | ||
| 23 | EQUNR | Equipment Number | ||
| 24 | E_ZSPANNP | Register factor: primary transformer voltage | ||
| 25 | E_ZSPANNS | Register factor: secondary transformer voltage | ||
| 26 | E_ZSTROMP | Register factor: primary transformer current | ||
| 27 | E_ZSTROMS | Register factor: secondary transformer current | ||
| 28 | E_ZWGRUPPE | Register Group | ||
| 29 | GERWECHS | Activity reason | ||
| 30 | KOMBINAT | Combination of a device category | ||
| 31 | KOMGRP | ARCR Command Group | ||
| 32 | KZSTICH | Status of sample device | ||
| 33 | LAND1 | Country Key | ||
| 34 | LGORT_D | Storage location | ||
| 35 | LOGIKNR | Logical device number | ||
| 36 | LOS | Sample lot | ||
| 37 | MANDT | Client | ||
| 38 | MATNR | Material Number | ||
| 39 | MESSDRCK | Measured Pressure (Outlet Pressure) in Bars | ||
| 40 | NOTIF_CODE | Notification code | ||
| 41 | ORDERCODE2 | Special Order Code for Dev./Dev. Category in Replacement | ||
| 42 | PARAMETR | Parametrization | ||
| 43 | PLOMBDAT | Date of last lead sealing | ||
| 44 | PLOMBE | Seal code | ||
| 45 | PRIMWNR | Winding number of active primary winding | ||
| 46 | PRIMWNR | Winding number of active primary winding | ||
| 47 | REGIO | Region (State, Province, County) | ||
| 48 | REGPOLIT | Political regional structure element | ||
| 49 | SCHWGRAD | Difficulty level: Factor for meter reader payment | ||
| 50 | SEKWNR | Winding number of active secondary winding | ||
| 51 | SEKWNR | Winding number of active secondary winding | ||
| 52 | STATANZ | Number in statistics | ||
| 53 | UEBERVER | Transformation ratio | ||
| 54 | UMBAUDAT | Modification date | ||
| 55 | UMBAUGR | Modification reason | ||
| 56 | VLZEIT_DEV | Individual cal. validity (years) of dev. subject to certif. | ||
| 57 | WECHSEL | Advance replacement year | ||
| 58 | WERKS_D | Plant | ||
| 59 | WGRUPPE | Winding group |