SAP ABAP Table QMIPS_INSP_CHV (Dependent Characteristic Specifications with Addit. Info.)
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
QM-PT-IP (Application Component) Inspection Planning
⤷
QMIP_EA (Package) QM: Inspection Plans and Characteristics
⤷
⤷
Basic Data
| Table Category | INTTAB | Structure |
| Structure | QMIPS_INSP_CHV |
|
| Short Description | Dependent Characteristic Specifications with Addit. Info. |
Delivery and Maintenance
| Pool/cluster | ||
| Delivery Class | ||
| Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
| |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|---|---|---|---|---|---|---|---|---|---|
| 1 | |
0 | 0 | Maint. Task List: Inspection Characteristic Values | |||||
| 2 | |
CP_TASK_LIST_MAINT_MODE | CP_TASK_LIST_MAINT_MODE | CHAR | 1 | 0 | Maint. Task List: Mode | ||
| 3 | |
CP_TASK_LIST_MAINT_POINTER | NUMC | 10 | 0 | Maint. Task List: Pointer of Checkbox Structure | |||
| 4 | |
PLNFOLGE | PLNFOLGE | CHAR | 6 | 0 | Sequence | ||
| 5 | |
VORNR | VORNR | CHAR | 4 | 0 | Operation/Activity Number | ||
| 6 | |
OPRID | CHAR8 | CHAR | 8 | 0 | Operation ID | ||
| 7 | |
QMERKNRP | QMERKNRP | NUMC | 4 | 0 | Inspection Characteristic Number | ||
| 8 | |
QZUORDNR | QZUORDNR | NUMC | 4 | 0 | Number for Dependent Characteristic Specifications | ||
| 9 | |
MATNR | MATNR | CHAR | 18 | 0 | Material Number | * | |
| 10 | |
WERKS_D | WERKS | CHAR | 4 | 0 | Plant | * | |
| 11 | |
ELIFN | LIFNR | CHAR | 10 | 0 | Vendor's account number | * | |
| 12 | |
EKUNN | KUNNR | CHAR | 10 | 0 | Account number of customer | * | |
| 13 | |
QSUCHFELD | CHAR20 | CHAR | 20 | 0 | Search Field for Customer-Specific Task List Selection | ||
| 14 | |
PSNFH | PSNFH | NUMC | 4 | 0 | Item Number for Production Resource/Tool | ||
| 15 | |
QSTELLEN | QSTELLEN | INT1 | 3 | 0 | Number of Places to the Right of a Decimal Point (Accuracy) | ||
| 16 | |
QMASSEH | MEINS | UNIT | 3 | 0 | Unit of Measurement, in Which Quantitative Data Is Stored | * | |
| 17 | |
ISOCD_UNIT | ISOCD_UNIT | CHAR | 3 | 0 | ISO code for unit of measurement | * | |
| 18 | |
QSOLLWERTC | QSOLLWERTC | CHAR | 16 | 0 | Target Value for a Quantitative Characteristic | ||
| 19 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 20 | |
QTOLUNC | QSOLLWERTC | CHAR | 16 | 0 | Lower Specification Limit | ||
| 21 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 22 | |
QTOLOBC | QSOLLWERTC | CHAR | 16 | 0 | Upper Specification Limit | ||
| 23 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 24 | |
QKLASSZAHL | QKLASSZAHL | INT1 | 3 | 0 | Number of Value Classes for Inspection Results | ||
| 25 | |
QKLASSBRC | QSOLLWERTC | CHAR | 16 | 0 | Class Width | ||
| 26 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 27 | |
QKLASMITC | QSOLLWERTC | CHAR | 16 | 0 | Class Midpoint | ||
| 28 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 29 | |
QGRENZO1C | QSOLLWERTC | CHAR | 16 | 0 | First Upper Specification Limit | ||
| 30 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 31 | |
QGRENZU1C | QSOLLWERTC | CHAR | 16 | 0 | First Lower Specification Limit | ||
| 32 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 33 | |
QGRENZO2C | QSOLLWERTC | CHAR | 16 | 0 | Second Upper Specification Limit | ||
| 34 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 35 | |
QGRENZU2C | QSOLLWERTC | CHAR | 16 | 0 | Second Lower Specification Limit | ||
| 36 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 37 | |
QPLAUSIOBC | QSOLLWERTC | CHAR | 16 | 0 | Upper Plausibility Limit | ||
| 38 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 39 | |
QPLAUSIUNC | QSOLLWERTC | CHAR | 16 | 0 | Lower Plausibility Limit | ||
| 40 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 41 | |
QTOLWOBC | QSOLLWERTC | CHAR | 16 | 0 | Change to Upper Specification Limit | ||
| 42 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 43 | |
QTOLWUNC | QSOLLWERTC | CHAR | 16 | 0 | Change to Lower Specification Limit | ||
| 44 | |
QNINITIAL | QKZ | CHAR | 1 | 0 | Value Not Initial if Set | ||
| 45 | |
QTOLWAB_C | CHAR10 | CHAR | 10 | 0 | Date, from Which the Tolerance Change Is Valid (Batch Input) | ||
| 46 | |
QTOLWBIS_C | CHAR10 | CHAR | 10 | 0 | Date, to Which the Tolerance Change Is Valid (Batch Input) | ||
| 47 | |
QKTTAB | QKTTAB | CHAR | 1 | 0 | Catalog Entry Is a Selected Set | ||
| 48 | |
QKATAUSW | QKATART | CHAR | 1 | 0 | Catalog Type of Assigned Code Group or Selected Set | * | |
| 49 | |
QCGRAUSW | QCGRAUSW | CHAR | 8 | 0 | Assigned Code Group or Selected Set | ||
| 50 | |
QWERKAUSW | WERKS | CHAR | 4 | 0 | Plant of the Assigned Selected Set | * | |
| 51 | |
QKTTAB | QKTTAB | CHAR | 1 | 0 | Catalog Entry Is a Selected Set | ||
| 52 | |
QKATAUSW | QKATART | CHAR | 1 | 0 | Catalog Type of Assigned Code Group or Selected Set | * | |
| 53 | |
QCODEGR | QCGRAUSW | CHAR | 8 | 0 | Assigned Code Group | ||
| 54 | |
QWERKAUSW | WERKS | CHAR | 4 | 0 | Plant of the Assigned Selected Set | * | |
| 55 | |
QKTTAB | QKTTAB | CHAR | 1 | 0 | Catalog Entry Is a Selected Set | ||
| 56 | |
QKATAUSW | QKATART | CHAR | 1 | 0 | Catalog Type of Assigned Code Group or Selected Set | * | |
| 57 | |
QCODEGR | QCGRAUSW | CHAR | 8 | 0 | Assigned Code Group | ||
| 58 | |
QWERKAUSW | WERKS | CHAR | 4 | 0 | Plant of the Assigned Selected Set | * | |
| 59 | |
QKTTAB | QKTTAB | CHAR | 1 | 0 | Catalog Entry Is a Selected Set | ||
| 60 | |
QKATAUSW | QKATART | CHAR | 1 | 0 | Catalog Type of Assigned Code Group or Selected Set | * | |
| 61 | |
QCODEGR | QCGRAUSW | CHAR | 8 | 0 | Assigned Code Group | ||
| 62 | |
QWERKAUSW | WERKS | CHAR | 4 | 0 | Plant of the Assigned Selected Set | * | |
| 63 | |
QKTTAB | QKTTAB | CHAR | 1 | 0 | Catalog Entry Is a Selected Set | ||
| 64 | |
QKATAUSW | QKATART | CHAR | 1 | 0 | Catalog Type of Assigned Code Group or Selected Set | * | |
| 65 | |
QCODEGR | QCGRAUSW | CHAR | 8 | 0 | Assigned Code Group | ||
| 66 | |
QWERKAUSW | WERKS | CHAR | 4 | 0 | Plant of the Assigned Selected Set | * | |
| 67 | |
Q_MS_OBJECT | Q_MS_OBJECT | CHAR | 30 | 0 | Object for Multiple Specifications | ||
| 68 | |
Q_MS_OBJTYPE | Q_MS_OBJTYPE | CHAR | 2 | 0 | Type of Object for Multiple Specifications | * | |
| 69 | |
QKZ_MS_REF | QKZ | CHAR | 1 | 0 | Reference for Standard Specifications | ||
| 70 | |
NUMC4 | NUMC4 | NUMC | 4 | 0 | Count parameters | ||
| 71 | |
QTXT_CHA | QKURZTEXT | CHAR | 40 | 0 | Short Text for Inspection Characteristic |
History
| Last changed by/on | SAP | 20130529 |
| SAP Release Created in | 605 |