SAP ABAP Table SCSM_TOOLDEF_WRONG (Structure for Incorrect Tool Definition)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-CCM-MON (Application Component) Monitoring
     SCSM_CEN_CONFIG (Package) CCMS Consistency Check
Basic Data
Table Category INTTAB    Structure 
Structure SCSM_TOOLDEF_WRONG   Table Relationship Diagram
Short Description Structure for Incorrect Tool Definition    
Delivery and Maintenance
Pool/cluster      
Delivery Class      
Data Browser/Table View Maintenance     Display/Maintenance Allowed with Restrictions 
Components
     
Field Key Data Element Domain Data
Type
Length Decimal
Places
Short Description Check
table
1 CHECK_CUST SCSM_CHECK_CUST   STRU 0   0    
2 CHECKGROUP SCSM_CHECKGROUP TEXT60 CHAR 60   0   Check Group for CCMS Checks  
3 MTECLASS ALCUSGROUP TEXT40 CHAR 40   0   Alert: Customization: Name of Customization Group  
4 THRSHG2Y SCSM_TOBE_G2Y INT4 INT4 10   0   Threshold Value: Green -> Yellow from Customizing  
5 THRSHY2R SCSM_TOBE_Y2R INT4 INT4 10   0   Threshold Value: Yellow -> Red from Customizing  
6 THRSHR2Y SCSM_TOBE_R2Y INT4 INT4 10   0   Threshold Value: Red -> Yellow from Customizing  
7 THRSHY2G SCSM_TOBE_Y2G INT4 INT4 10   0   Threshold Value: Yellow -> Green from Customizing  
8 TOOLCOLL ALTOOLKEYCOL TEXT40 CHAR 40   0   Alert: Logical Name of Auto-Reaction Method  
9 TOOLONA ALTOOLKEYONA TEXT40 CHAR 40   0   Alert: Logical Name of Auto-Reaction Method  
10 TOOLANA ALTOOLKEYANA TEXT40 CHAR 40   0   Alert: Logical Name of Analysis Method  
11 CHECK_THRESH SCSM_CHECK_TRESH FLAG CHAR 1   0   Check Threshold Values  
12 CHECK_TOOLS SCSM_CHECK_TOOLS FLAG CHAR 1   0   Check Tool Assignments  
13 CHECK_COLL SCSM_CHECK_ALERTCOLL FLAG CHAR 1   0   Check Data Collection Methods  
14 MAXAGE SCSM_ALERTMAXAGE   INT4 10   0   Last Update of an MTE in Minutes  
15 COL_TO_DEF SALRTLDEF   STRU 0   0    
16 TOOLNAME ALTOOLKEY TEXT40 CHAR 40   0   Alert: Logical Name of Tool  
17 TOOLDISPAT ALTOOLDISP CHAR40 CHAR 40   0   Alert method dispatcher  
18 TOOLDEFSTA ALTOOLSTAT   INT4 10   0   Alert: Tool: Alert Tool Status  
19 CLASSORSPC ALUSECLASS   INT4 10   0   Alert: Use Class or TID-Specif. Customizing and Tools  
20 ASSBYPAR ALASSBYPAR CHAR1 CHAR 1   0   Alert: Shows if the method is assigned by a parent  
21 ONA_TO_DEF SALRTLDEF   STRU 0   0    
22 TOOLNAME ALTOOLKEY TEXT40 CHAR 40   0   Alert: Logical Name of Tool  
23 TOOLDISPAT ALTOOLDISP CHAR40 CHAR 40   0   Alert method dispatcher  
24 TOOLDEFSTA ALTOOLSTAT   INT4 10   0   Alert: Tool: Alert Tool Status  
25 CLASSORSPC ALUSECLASS   INT4 10   0   Alert: Use Class or TID-Specif. Customizing and Tools  
26 ASSBYPAR ALASSBYPAR CHAR1 CHAR 1   0   Alert: Shows if the method is assigned by a parent  
27 ANA_TO_DEF SALRTLDEF   STRU 0   0    
28 TOOLNAME ALTOOLKEY TEXT40 CHAR 40   0   Alert: Logical Name of Tool  
29 TOOLDISPAT ALTOOLDISP CHAR40 CHAR 40   0   Alert method dispatcher  
30 TOOLDEFSTA ALTOOLSTAT   INT4 10   0   Alert: Tool: Alert Tool Status  
31 CLASSORSPC ALUSECLASS   INT4 10   0   Alert: Use Class or TID-Specif. Customizing and Tools  
32 ASSBYPAR ALASSBYPAR CHAR1 CHAR 1   0   Alert: Shows if the method is assigned by a parent  
33 TID ALGLOBTID   STRU 0   0    
34 MTSYSID SYSYSID SYCHAR08 CHAR 8   0   Name of SAP System  
35 MTMCNAME ALMCNAME TEXT40 CHAR 40   0   Alert: Name of Monitoring Context  
36 MTNUMRANGE ALTIDNUMRG CHAR3 CHAR 3   0   Alert: monitoring type number range (perm., temp, ...)  
37 MTUID ALTIDUID CHAR10 CHAR 10   0   ALert: Unique Identifier for Monitoring Types (used in TID)  
38 MTCLASS ALTIDMTCL CHAR3 CHAR 3   0   Alert: monitoring type class (perf., single msg.,...)  
39 MTINDEX ALTIDINDEX CHAR10 CHAR 10   0   Alert: internal handle for TID  
40 EXTINDEX ALTIDINDEX CHAR10 CHAR 10   0   Alert: internal handle for TID  
41 GEN_INFO SALRMTEGEN   STRU 0   0    
42 .INCLUDE       0   0   Alert: global monitoring type identifier  
43 MTSYSID SYSYSID SYCHAR08 CHAR 8   0   Name of SAP System  
44 MTMCNAME ALMCNAME TEXT40 CHAR 40   0   Alert: Name of Monitoring Context  
45 MTNUMRANGE ALTIDNUMRG CHAR3 CHAR 3   0   Alert: monitoring type number range (perm., temp, ...)  
46 MTUID ALTIDUID CHAR10 CHAR 10   0   ALert: Unique Identifier for Monitoring Types (used in TID)  
47 MTCLASS ALTIDMTCL CHAR3 CHAR 3   0   Alert: monitoring type class (perf., single msg.,...)  
48 MTINDEX ALTIDINDEX CHAR10 CHAR 10   0   Alert: internal handle for TID  
49 EXTINDEX ALTIDINDEX CHAR10 CHAR 10   0   Alert: internal handle for TID  
50 SHORTNAME ALNAMESHRT CHAR40 CHAR 40   0   Alert: short name of MTE  
51 MTECLASS ALMTECLASS TEXT40 CHAR 40   0   CCMS Monitoring Architecture: Name of MTE class  
52 OBJECTNAME ALMOBJECT CHAR40 CHAR 40   0   Alert: Name of Monitoring Object  
53 MTESTATUS ALTDSTATUS   INT4 10   0   Alert: MT: Type Def Status  
54 MTESUBTYPE ALMTESUBT   INT4 10   0   Alert: monitoring tree element: subtype  
History
Last changed by/on SAP  20130604 
SAP Release Created in 711