SAP ABAP View U_30011 (Device Category)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷
IS-U (Application Component) SAP Utilities
⤷
EE99 (Package) IS-U: Data Model
⤷
⤷
Basic Data
| View Type | D | Database View |
| Database View | U_30011 | |
| Short Description | Device Category | |
| Root table | ETYP | Dev. Cat.: IS-U Additional Material Data |
Table
| # | Table Name | Foreign Table | Foreign Field | Foreign DIR |
|---|---|---|---|---|
| 1 | ETYP | |||
| 2 |
Join Conditions
| # | Table Name | Field Name | Negation | Operator | Constants | Cont. line | AND/OR | Offset | F Length | Mco Field |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | MANDT | JL | EQ | 0 | 0 | |||||
| 2 | MANDT | JR | EQ | AND | 0 | 0 | ||||
| 3 | MATNR | JL | EQ | 0 | 0 | |||||
| 4 | MATNR | JR | EQ | 0 | 0 | |||||
View Fields
| # | View field | Table | Field | Maintenance Flag | Key | Data element | Mod | Short Description |
|---|---|---|---|---|---|---|---|---|
| 1 | MANDT | MANDT | Client | |||||
| 2 | MATNR | MATNR | Material Number | |||||
| 3 | FUNKLAS | FUNKLAS | Function class | |||||
| 4 | BAUKLAS | BAUKLAS | Construction class | |||||
| 5 | BAUFORM | BAUFORM | Device category description | |||||
| 6 | BAUTXT | BAUTXT | Text for description | |||||
| 7 | PREISKLA | PREISKLA | Price Class | |||||
| 8 | PTBNUM | PTBNUM | PTI number | |||||
| 9 | DVGWNUM | DVGWNUM | GGWA number | |||||
| 10 | BGLKZ | BGLKZ | Type of certification requirement | |||||
| 11 | VLZEITT | VLZEIT | Calibration validity (yrs) for ext. devs subject to certif. | |||||
| 12 | VLZEITTI | VLZEITI | Internal certification period (years) | |||||
| 13 | VLZEITN | VLZEITN | Old cal. validity/int. cert. period (yrs) until prod. year | |||||
| 14 | VLKZBAU | BISBAUJR | Prod. yr until which old calib. valid./int.insp.per.is valid | |||||
| 15 | ZWGRUPPE | E_ZWGRUPPE | Register Group | |||||
| 16 | EAGRUPPE | EAGRUPPE | Input/output group | |||||
| 17 | MESSART | MESSART | Type of measurement | |||||
| 18 | UEBERVER | UEBERVER | Transformation ratio | |||||
| 19 | BGLNETZ | BGLNETZ | Certify installed devices | |||||
| 20 | WGRUPPE | WGRUPPE | Winding group | |||||
| 21 | PRIMWNR1 | PRIMWNR | Winding number of active primary winding | |||||
| 22 | SEKWNR1 | SEKWNR | Winding number of active secondary winding | |||||
| 23 | PRIMWNR2 | PRIMWNR | Winding number of active primary winding | |||||
| 24 | SEKWNR2 | SEKWNR | Winding number of active secondary winding | |||||
| 25 | AENAM | AENAM | Name of Person Who Changed Object | |||||
| 26 | AEDAT | AEDAT | Last Changed On | |||||
| 27 | ZSPANNS | E_ZSPANNS | Register factor: secondary transformer voltage | |||||
| 28 | ZSTROMS | E_ZSTROMS | Register factor: secondary transformer current | |||||
| 29 | ZSPANNP | E_ZSPANNP | Register factor: primary transformer voltage | |||||
| 30 | ZSTROMP | E_ZSTROMP | Register factor: primary transformer current | |||||
Maintenance Status
| read only |
| read and change |
| Time-dependent views: like U, validity data like ' ' |
| read, change, delete and insert |
| Delivery Class | ||
| Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
History
| Last changed by/on | SAP | 20140121 |
| SAP Release Created in |