SAP ABAP Table ISU_TE685_ALL (Help Struct. for Selecting Repl.Volume Corr.Factor Proc.)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷
IS-U-BI (Application Component) Contract Billing
⤷
EE20 (Package) IS-U: Billing
⤷
⤷
Basic Data
| Table Category | INTTAB | Structure |
| Structure | ISU_TE685_ALL |
|
| Short Description | Help Struct. for Selecting Repl.Volume Corr.Factor Proc. |
Delivery and Maintenance
| Pool/cluster | ||
| Delivery Class | ||
| Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
| |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|---|---|---|---|---|---|---|---|---|---|
| 1 | |
0 | 0 | Vol. Corr. Fac. Proc. | |||||
| 2 | |
MANDT | MANDT | CLNT | 3 | 0 | Client | T000 | |
| 3 | |
E_ZUZVER | E_ZUZVER | CHAR | 8 | 0 | Volume Correction Factor Procedure | * | |
| 4 | |
THGBER | THGBER | CHAR | 2 | 0 | Inclusion of factors in thermal gas billing | ||
| 5 | |
GEWKEY | GEWKEY | CHAR | 8 | 0 | Weighting key | TE266 | |
| 6 | |
VFZZNAKT | VFZZNAKT | CHAR | 1 | 0 | Volume correction factor procedure inactive | ||
| 7 | |
MESDVON685 | MESDVON685 | DEC | 7 | 4 | From-measured pressure | ||
| 8 | |
MESDBIS685 | MESDBIS685 | DEC | 7 | 4 | To-measured pressure | ||
| 9 | |
NENNBELV | NENNBEL | DEC | 10 | 4 | From-nominal load | ||
| 10 | |
NENNBELB | NENNBEL | DEC | 10 | 4 | To-nominal load | ||
| 11 | |
FTEMPKZ | FTEMPKZ | CHAR | 1 | 0 | Fixed temperature | ||
| 12 | |
ARTMITTEL | ARTMITTEL | CHAR | 2 | 0 | Type of averaging | ||
| 13 | |
TEMPMITTEL | TEMPMITTEL | CHAR | 2 | 0 | Time base: temperature average | ||
| 14 | |
LUFTMESSD | LUFTMESSD | CHAR | 2 | 0 | Air Pressure | ||
| 15 | |
KORRMESSD | KORRMESSD | CHAR | 1 | 0 | Air pressure correction | ||
| 16 | |
KZAHLKZ | KZAHLKZ | CHAR | 2 | 0 | Determination of gas law deviation factor | ||
| 17 | |
KORRKZAHL | KORRKZAHL | CHAR | 1 | 0 | Correction of gas law deviation factor | ||
| 18 | |
ABGRENZKZ | ABGRENZKZ | CHAR | 1 | 0 | Proration for Changes in Measured Pressure | ||
| 19 | |
NPAMB | PAMB | DEC | 7 | 5 | Standard air pressure | ||
| 20 | |
TEMPSTEU | TEMPSTEU | CHAR | 1 | 0 | Indicator: ignore temperature component | ||
| 21 | |
FREMDZZZ | FREMDZZZ | CHAR | 1 | 0 | Volume correction factor from register relationship ZZ | ||
| 22 | |
FREMDZZE | FREMDZZE | CHAR | 1 | 0 | Volume correction factor from register relationship ZE | ||
| 23 | |
E_ZUSTZFIX | E_ZUSTZFIX | CHAR | 1 | 0 | Fixed volume correction factor | ||
| 24 | |
USECATZZ | USECATZZ | CHAR | 1 | 0 | Usage type of fixed volume correction factor | ||
| 25 | |
E_RUNDUNG | E_RUNDUNG | CHAR | 2 | 0 | Starting Point for Rounding | ||
| 26 | |
RUNDART | RUNDART | CHAR | 1 | 0 | Rounding Category | ||
| 27 | |
AKLASSE | AKLASSE | CHAR | 4 | 0 | Billing class | EAKLASSE | |
| 28 | |
E_RUNDUNG | E_RUNDUNG | CHAR | 2 | 0 | Starting Point for Rounding | ||
| 29 | |
RUNDART | RUNDART | CHAR | 1 | 0 | Rounding Category | ||
| 30 | |
MASS_ZZ | MEINS | UNIT | 3 | 0 | Unit of measurement after conversion w. volume corr. factor | * | |
| 31 | |
MASS_ZZQ | MEINS | UNIT | 3 | 0 | Unit of measurement before conversion with vol. corr. factor | * | |
| 32 | |
NTEMPB | NTEMPB | DEC | 5 | 2 | Standard temperature in absolute units | ||
| 33 | |
OTEMPB | OTEMPB | DEC | 5 | 2 | Zero point of temperature scale in absolute units | ||
| 34 | |
GAS_PRS_KZ | GAS_PRS_KZ | CHAR | 1 | 0 | Gas pressure determination via gas pressure area | ||
| 35 | |
CRG_PRS_KZ | CRG_PRS_KZ | CHAR | 1 | 0 | Gas Pressure Correction | ||
| 36 | |
SBZUZVER | SBZUZVER | CHAR | 8 | 0 | Replacement volume corrctn factor proc. for reg. reltnshp ZZ | * | |
| 37 | |
TIMRTEMP | TIMRTEMP | CHAR | 1 | 0 | Daily temperature | ||
| 38 | |
SUPCOMPR | SUPCOMPR | CHAR | 1 | 0 | Supercompressibility Factor Is Used | ||
| 39 | |
TPSUPPR | TPSUPPR | CHAR | 1 | 0 | Provide temperature component extra | ||
| 40 | |
PRSUPPR | PRSUPPR | CHAR | 1 | 0 | Provide pressure component extra | ||
| 41 | |
JOULTHOM | JOULTHOM | CHAR | 1 | 0 | Take Into Account the Joule-Thomsom Effect | ||
| 42 | |
RATIOJTH | RATIOJTH | CHAR | 2 | 0 | Key: Pressure-Temperature Ratio Joule-Thomson Effect | * | |
| 43 | |
LASTVAL_ZV | LASTVAL_ZV | CHAR | 1 | 0 | Volume Correction Factor Proc.: Last Value in Demand Billing | ||
| 44 | |
E_ZUSTZZW | E_ZUSTZZW | CHAR | 1 | 0 | Fixed volume correction factor from register | ||
| 45 | |
USEZUSTZZW | USEZUSTZZW | CHAR | 1 | 0 | Usage type of VC factor from register | ||
| 46 | |
APDAILY | APDAILY | CHAR | 1 | 0 | Air Pressure to-the-Day | ||
| 47 | |
SPRAS | SPRAS | LANG | 1 | 0 | Language Key | * | |
| 48 | |
TXT40 | TEXT40 | CHAR | 40 | 0 | Text, length 40 |
Foreign Keys
| |
Source Table | Source Column | Foreign Table | Foreign Column | Dependency Factor | Cardinality left | Cardinality right |
|---|---|---|---|---|---|---|---|
| 1 | ISU_TE685_ALL | AKLASSE | |
|
REF | 1 | CN |
| 2 | ISU_TE685_ALL | GEWKEY | |
|
1 | CN | |
| 3 | ISU_TE685_ALL | MANDT | |
|
KEY | 1 | CN |
History
| Last changed by/on | SAP | 20130529 |
| SAP Release Created in |