1 |
MANDANT |
|
MANDT |
MANDT |
CLNT |
3 |
0 |
Client |
T000 |
2 |
PRUEFLOS |
|
QPLOS |
QPLOS |
NUMC |
12 |
0 |
Inspection Lot Number |
QALS |
3 |
VORGLFNR |
|
QLFNKN |
KNTNR |
NUMC |
8 |
0 |
Current Node Number from Order Counter APLZL |
|
4 |
MERKNR |
|
QMERKNRP |
QMERKNRP |
NUMC |
4 |
0 |
Inspection Characteristic Number |
|
5 |
ERSTELLER |
|
QERSTELLER |
QAENDERER |
CHAR |
12 |
0 |
Name of User Who Created the Data Record |
|
6 |
ERSTELLDAT |
|
QDATUMERST |
DATUM |
DATS |
8 |
0 |
Date on Which the Data Record Was Created |
|
7 |
AENDERER |
|
QAENDERER |
QAENDERER |
CHAR |
12 |
0 |
Name of User who Most Recently Changed the Data Record |
|
8 |
AENDERDAT |
|
QDATUMAEND |
DATUM |
DATS |
8 |
0 |
Date on Which Data Record Was Changed |
|
9 |
PHYSPROBE |
|
QPHYSPROBE |
QPROBENR |
NUMC |
6 |
0 |
Number of the Partial Sample |
|
10 |
SATZSTATUS |
|
QSTATUS |
QSTATUS |
CHAR |
1 |
0 |
Specification Record Status |
TQ76 |
11 |
STEUERKZ |
|
QMKCONTROL |
QMKCONTROL |
CHAR |
30 |
0 |
Cntrl Indicator String for Insp. Char./Master Insp. Char. |
|
12 |
TSTICHPRKZ |
|
QTSTICHPRO |
QKZUMFS |
CHAR |
1 |
0 |
Partial Samples Possible |
|
13 |
NOINPUTKZ |
|
QNOINPUT |
QKZ |
CHAR |
1 |
0 |
Results Are Calculated Internally |
|
14 |
NIPLANMKKZ |
|
QNIPLANMK |
QKZ |
CHAR |
1 |
0 |
Unplanned Characteristic |
|
15 |
QMTB_WERKS |
|
WERKS_D |
WERKS |
CHAR |
4 |
0 |
Plant |
T001W |
16 |
PMETHODE |
|
QPMETHODE |
QPMETHODE |
CHAR |
8 |
0 |
Inspection Method |
QMTB |
17 |
PMTVERSION |
|
QVERSNRPM |
QVERSNR |
CHAR |
6 |
0 |
Version Number of the Inspection Method |
|
18 |
QPMK_WERKS |
|
QZAEHLER |
QZAEHLER |
CHAR |
4 |
0 |
Plant for the Master Inspection Characteristic |
|
19 |
VERWMERKM |
|
QMERKNR |
QMERKNR |
CHAR |
8 |
0 |
Master Inspection Characteristics |
QPMK |
20 |
MKVERSION |
|
QVERSNRMK |
QVERSNR |
CHAR |
6 |
0 |
Version Number of the Master Inspection Characteristic |
|
21 |
MERKGEW |
|
QMERKGEW |
QMERKKLAS |
CHAR |
2 |
0 |
Weighting of the Characteristic |
TQ17A |
22 |
KURZTEXT |
|
QMKKURZTXT |
QKURZTEXT |
CHAR |
40 |
0 |
Short Text for the Inspection Characteristic |
|
23 |
LTEXTKZ |
|
QLTEXTKZ |
QKZ |
CHAR |
1 |
0 |
Inspection Characteristic Long Text Exists |
|
24 |
LTEXTSPR |
|
SPRAS |
SPRAS |
LANG |
1 |
0 |
Language Key |
T002 |
25 |
LTEXTEKZ |
|
QKZPRZIEH |
QKZWSP |
CHAR |
1 |
0 |
Physical-Sample-Drawing Text Exists |
|
26 |
LTXTENTSPR |
|
SPRAS |
SPRAS |
LANG |
1 |
0 |
Language Key |
T002 |
27 |
PRUEFQUALI |
|
QPRQUALIF |
QPRQUALIF |
CHAR |
5 |
0 |
Inspector Qualification |
TQ11 |
28 |
FORMEL1 |
|
QFORMEL |
QFORMEL |
CHAR |
60 |
0 |
Formula Field |
|
29 |
FORMEL2 |
|
QFORMEL |
QFORMEL |
CHAR |
60 |
0 |
Formula Field |
|
30 |
DUMMY10 |
|
QTXT10 |
QTXT10 |
CHAR |
10 |
0 |
Text Line for Additional Information |
|
31 |
DUMMY20 |
|
QTXT20 |
QTXT20 |
CHAR |
20 |
0 |
Text Line for Additional Information |
|
32 |
DUMMY40 |
|
QTXT40 |
QTXT40 |
CHAR |
40 |
0 |
Text Line for Additional Information |
|
33 |
CODEGR9U |
|
QCODEGRPU |
QCODEGRP |
CHAR |
8 |
0 |
Defect Code Group for Rejection at Lower Tolerance |
|
34 |
CODE9U |
|
QCODEU |
QCODE |
CHAR |
4 |
0 |
Defect Code for Rejection at Lower Specification Limit |
|
35 |
CODEGR9O |
|
QCODEGRPO |
QCODEGRP |
CHAR |
8 |
0 |
Defect Code Group for Rejection at Upper Tolerance |
|
36 |
CODEVR9U |
|
QVERSNR |
QVERSNR |
CHAR |
6 |
0 |
Version Number |
|
37 |
CODE9O |
|
QCODEO |
QCODE |
CHAR |
4 |
0 |
Defect Code for Rejection at Upper Specification Limit |
|
38 |
CODEVR9O |
|
QVERSNR |
QVERSNR |
CHAR |
6 |
0 |
Version Number |
|
39 |
STELLEN |
|
QSTELLEN |
QSTELLEN |
INT1 |
3 |
0 |
Number of Places to the Right of a Decimal Point (Accuracy) |
|
40 |
MASSEINHSW |
|
QMASSEH |
MEINS |
UNIT |
3 |
0 |
Unit of Measurement, in Which Quantitative Data Is Stored |
T006 |
41 |
SOLLWERT |
|
QSOLLWERTE |
QSOLLWERTE |
FLTP |
16 |
16 |
Target Value for a Quantitative Characteristic |
|
42 |
SOLLWNI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
43 |
TOLERANZOB |
|
QTOLOB |
QSOLLWERTE |
FLTP |
16 |
16 |
Upper Specification Limit |
|
44 |
TOLOBNI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
45 |
TOLERANZUN |
|
QTOLUN |
QSOLLWERTE |
FLTP |
16 |
16 |
Lower Tolerance Limit |
|
46 |
TOLUNNI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
47 |
GRENZEOB1 |
|
QGRENZOB1 |
QSOLLWERTE |
FLTP |
16 |
16 |
First Upper Specification Limit |
|
48 |
GRENZOB1NI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
49 |
TOLERWKZ |
|
QTOLERWKZ |
QKZ |
CHAR |
1 |
0 |
Tolerance Change Is Active |
|
50 |
GRENZEUN1 |
|
QGRENZUN1 |
QSOLLWERTE |
FLTP |
16 |
16 |
First Lower Specification Limit |
|
51 |
GRENZUN1NI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
52 |
GRENZEOB2 |
|
QGRENZOB2 |
QSOLLWERTE |
FLTP |
16 |
16 |
Second Upper Specification Limit |
|
53 |
GRENZOB2NI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
54 |
GRENZUN2NI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
55 |
PLAUSIOBEN |
|
QPLAUSIOB |
QSOLLWERTE |
FLTP |
16 |
16 |
Upper Plausibility Limit |
|
56 |
GRENZEUN2 |
|
QGRENZUN2 |
QSOLLWERTE |
FLTP |
16 |
16 |
Second Lower Specification Limit |
|
57 |
PLAUSIOBNI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
58 |
PLAUSIUNTE |
|
QPLAUSIUN |
QSOLLWERTE |
FLTP |
16 |
16 |
Lower Plausibility Limit |
|
59 |
PLAUSIUNNI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
60 |
KLASANZAHL |
|
QKLASSZAHL |
QKLASSZAHL |
INT1 |
3 |
0 |
Number of Value Classes for Inspection Results |
|
61 |
KLASBREITE |
|
QKLASSBR |
QSOLLWERTE |
FLTP |
16 |
16 |
Class Width |
|
62 |
KLASBRNI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
63 |
KLASMITTE |
|
QKLASSMIT |
QSOLLWERTE |
FLTP |
16 |
16 |
Class Midpoint |
|
64 |
KLASMINI |
|
QNINITIAL |
QKZ |
CHAR |
1 |
0 |
Value Not Initial if Set |
|
65 |
STICHPRVER |
|
QSTICHVERF |
QSTPRVER |
CHAR |
8 |
0 |
Sampling Procedure in Inspection Characteristic |
QDSV |
66 |
FAKPLANME |
|
QUMREN |
QUMRENFAK |
FLTP |
16 |
16 |
Factor for Converting MatUnitOfMeasure to SampUnitOfMeasure |
|
67 |
FAKPROBME |
|
QUMRENPME |
QUMRENFAK |
FLTP |
16 |
16 |
Factor for Converting SampUnitOfMeasure to MatUnitOfMeasure |
|
68 |
ANTVERF |
|
QEANTVERF |
QEANTVERF |
CHAR |
2 |
0 |
Fraction Calculation |
TQ72 |
69 |
BEWREGEL |
|
QBEWERT |
QKEY1 |
CHAR |
2 |
0 |
Valuation Rule |
QDFM |
70 |
PROBMGFAK |
|
QPROBEFAK |
QPROBEFAK |
DEC |
5 |
2 |
Sample Quantity Factor for Sample(Mult. Sample Unit of Msr.) |
|
71 |
PROBEMGEH |
|
QPROBME |
MEINS |
UNIT |
3 |
0 |
Sample Unit of Measure |
T006 |
72 |
SOLLSTPUMF |
|
QGESUMF |
QANZAHL4 |
INT4 |
10 |
0 |
Sample Size that Has to Be Inspected for a Characteristic |
|
73 |
PRUEFUMF |
|
QPRUEFUMF |
QMENGEPLOS |
QUAN |
13 |
3 |
Quantity to Be Inspected |
|
74 |
MENGENEINH |
|
QPROBEMGEH |
MEINS |
UNIT |
3 |
0 |
Base Unit of Measure for the Sample Unit |
T006 |
75 |
HPZ |
|
QHPZ |
QKZ |
CHAR |
1 |
0 |
100% Inspection |
|
76 |
SOLLSTPANZ |
|
QSOSTPANZ |
QANZAHL2 |
INT2 |
5 |
0 |
Number of Planned Partial Samples |
|
77 |
ANTEILKZ |
|
QANTEILKZ |
QKZ |
CHAR |
1 |
0 |
Take Share Estimate into Account |
|
78 |
RUECKMELNR |
|
QRUECKNR |
QRUECKNR |
NUMC |
8 |
0 |
Confirmation Number for Inspection Characteristic |
|
79 |
KZEINSTELL |
|
QKZEINSTMK |
QKZEINSTMK |
CHAR |
1 |
0 |
Characteristic Type |
|
80 |
ZAEHL |
|
CIM_COUNT |
CIM_COUNT |
NUMC |
8 |
0 |
Internal counter |
|