Where Used List (Function Module) for SAP ABAP Table TC02 (Check whether an FCode is permitted)
SAP ABAP Table
TC02 (Check whether an FCode is permitted) is used by
# | Object Type | Object Name | Object Description | Package | Structure Package | Software Component |
---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |
||
1 | ![]() |
C2_DI_RECIPE_DIALOG VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
Dialog control for master recipe - objects process instruction and PIchar | ![]() |
![]() |
![]() |
2 | ![]() |
C2_DI_RECIPE_DIALOG VALUE(OK_CODE_IMP) LIKE TC02-FCODE
|
Dialog control for master recipe - objects process instruction and PIchar | ![]() |
![]() |
![]() |
3 | ![]() |
C4_DI_FT_DETAIL VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
Process instruction detail screen | ![]() |
![]() |
![]() |
4 | ![]() |
C4_DI_FT_LST_EDIT VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
Overview process instruction | ![]() |
![]() |
![]() |
5 | ![]() |
C5_DI_FV_DETAIL VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
PI characteristic detail screen | ![]() |
![]() |
![]() |
6 | ![]() |
C5_DI_FV_LST_EDIT VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
Overview PI characteristics | ![]() |
![]() |
![]() |
7 | ![]() |
CD_OV_O_ITM_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
8 | ![]() |
CD_OV_O_OPR_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
9 | ![]() |
CD_OV_O_PRT_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
10 | ![]() |
CD_OV_O_SEQ_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
11 | ![]() |
CE_DI_CALCULATION VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
Calculation of standard values | ![]() |
![]() |
![]() |
12 | ![]() |
CE_DI_CAP_PROCESS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
CAPP-Vorgabewertermittlung in der Workbench | ![]() |
![]() |
![]() |
13 | ![]() |
CF_DF_FHM_DETAIL_CALL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
PRT management detail screens in task lists and orders | ![]() |
![]() |
![]() |
14 | ![]() |
CF_DF_FHM_DETAIL_CALL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
PRT management detail screens in task lists and orders | ![]() |
![]() |
![]() |
15 | ![]() |
CF_DI_IMPORT_FHM_DETAIL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Import production resources/tools | ![]() |
![]() |
![]() |
16 | ![]() |
CF_DI_IMPORT_FHM_DETAIL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Import production resources/tools | ![]() |
![]() |
![]() |
17 | ![]() |
CF_OV_PRT_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
18 | ![]() |
CF_OV_PRT_OVV_SCREEN_PROCESS
|
Über Handle in die FHM Übersicht springen | ![]() |
![]() |
![]() |
19 | ![]() |
CI_OV_PAC_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
20 | ![]() |
CI_OV_PAC_OVV_SCREEN_PROCESS
|
Über Handle in die Wartungspaket-Übersicht springen | ![]() |
![]() |
![]() |
21 | ![]() |
CJDT_EVENT_PROCESSING
|
Message-Handling für Statusbearbeitung | ![]() |
![]() |
![]() |
22 | ![]() |
CJDT_EVENT_PROCESSING VALUE(OK_CODE) LIKE TC02-FCODE DEFAULT SPACE
|
Message-Handling für Statusbearbeitung | ![]() |
![]() |
![]() |
23 | ![]() |
CJDT_EVENT_PROCESSING VALUE(OK_CODE) LIKE TC02-FCODE
|
Message-Handling für Statusbearbeitung | ![]() |
![]() |
![]() |
24 | ![]() |
CM_DI_MAT_PROV_BTCI VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Komponentenzuordnung für Batch Input | ![]() |
![]() |
![]() |
25 | ![]() |
CM_DI_MAT_PROV_BTCI VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Komponentenzuordnung für Batch Input | ![]() |
![]() |
![]() |
26 | ![]() |
CM_FV_VERID_DISPLAY VALUE(OK_CODE_EXP) LIKE TC02-FCODE DEFAULT SPACE
|
Fertigungsversion anzeigen/ändern | ![]() |
![]() |
![]() |
27 | ![]() |
CM_OV_COM_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes PICK im Bereich Komponentenzuordung | ![]() |
![]() |
![]() |
28 | ![]() |
CM_OV_OK_CODE_PROVIDE VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Übergabe des Ok-Codes | ![]() |
![]() |
![]() |
29 | ![]() |
CN_GR_ACTIVITY_DETAIL
|
Call detail screens | ![]() |
![]() |
![]() |
30 | ![]() |
CN_OV_MST_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
31 | ![]() |
COCI_CONFIRM_MFLOW
|
Rückmeldung: Materialfluß | ![]() |
![]() |
![]() |
32 | ![]() |
COCI_PP_CONFIRM_MFLOW
|
Rückmeldung: Materialfluß | ![]() |
![]() |
![]() |
33 | ![]() |
CORU_S_PROCESS_OK_CODE REFERENCE(I_OK_CODE) TYPE TC02-FCODE
|
ok_code-processor | ![]() |
![]() |
![]() |
34 | ![]() |
COS6_MATERIAL_CHK REFERENCE(I_OKCODE) LIKE TC02-FCODE OPTIONAL
|
Überprüfung der Materialdaten | ![]() |
![]() |
![]() |
35 | ![]() |
CO_IH_GET_OK_CODE VALUE(COIH_OK_CODE_CURR) LIKE TC02-FCODE
|
IH-Auftrag: letzter OK-CODE des SAPLCOIH | ![]() |
![]() |
![]() |
36 | ![]() |
CO_IH_GET_OK_CODE VALUE(COIH_OK_CODE) LIKE TC02-FCODE
|
IH-Auftrag: letzter OK-CODE des SAPLCOIH | ![]() |
![]() |
![]() |
37 | ![]() |
CO_NB_PRODNET_FUNCTION_CHECK VALUE(OK_CODE) LIKE TC02-FCODE
|
Prüfen ob für netzspezifische Fkt. (Teil-)netz eingelesen | ![]() |
![]() |
![]() |
38 | ![]() |
CO_RU_CONFIRMATION VALUE(OK_CODE_EXP) LIKE TC02-FCODE
|
CIM-Rückmeldung: Rückmeldekey über Funktionsbausteine mit Dialog | ![]() |
![]() |
![]() |
39 | ![]() |
CO_VG_OPR_CHECK
|
Loop über Detailbilder gem. TCO60 ... | ![]() |
![]() |
![]() |
40 | ![]() |
CP_CC_S_COPY_CHECK VALUE(I_OK_CODE) LIKE TC02-FCODE
|
Prüfung der Hierarchie der zu kopierenden Objekte | ![]() |
![]() |
![]() |
41 | ![]() |
CP_DI_ALTERNATIVE_DETAIL_CALL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Access an alternative detail screen | ![]() |
![]() |
![]() |
42 | ![]() |
CP_DI_ALTERNATIVE_DETAIL_CALL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Access an alternative detail screen | ![]() |
![]() |
![]() |
43 | ![]() |
CP_DI_IMPORT_ALT_DETAIL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL
|
Import einer Alternative durch den DIRECT INPUT | ![]() |
![]() |
![]() |
44 | ![]() |
CP_DI_IMPORT_ALT_DETAIL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG
|
Import einer Alternative durch den DIRECT INPUT | ![]() |
![]() |
![]() |
45 | ![]() |
CP_DI_IMPORT_FHM_DETAIL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG
|
Import einer Fertigungshilfsmittelzuordnung durch den DIRECT INPUT | ![]() |
![]() |
![]() |
46 | ![]() |
CP_DI_IMPORT_FHM_DETAIL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL
|
Import einer Fertigungshilfsmittelzuordnung durch den DIRECT INPUT | ![]() |
![]() |
![]() |
47 | ![]() |
CP_DI_IMPORT_MAT_DETAIL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL
|
Import einer Materialplanzuordnung durch den DIRECT INPUT | ![]() |
![]() |
![]() |
48 | ![]() |
CP_DI_IMPORT_MAT_DETAIL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG
|
Import einer Materialplanzuordnung durch den DIRECT INPUT | ![]() |
![]() |
![]() |
49 | ![]() |
CP_DI_IMPORT_MAT_PROV VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG
|
Import einer Komponente durch den DIRECT INPUT | ![]() |
![]() |
![]() |
50 | ![]() |
CP_DI_IMPORT_MAT_PROV VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL
|
Import einer Komponente durch den DIRECT INPUT | ![]() |
![]() |
![]() |
51 | ![]() |
CP_DI_IMPORT_OPR_DETAIL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL
|
Import eines Vorganges durch den DIRECT INPUT | ![]() |
![]() |
![]() |
52 | ![]() |
CP_DI_IMPORT_OPR_DETAIL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG
|
Import eines Vorganges durch den DIRECT INPUT | ![]() |
![]() |
![]() |
53 | ![]() |
CP_DI_IMPORT_SEQ_DETAIL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG
|
Import einer Planfolge durch den DIRECT INPUT | ![]() |
![]() |
![]() |
54 | ![]() |
CP_DI_IMPORT_SEQ_DETAIL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL
|
Import einer Planfolge durch den DIRECT INPUT | ![]() |
![]() |
![]() |
55 | ![]() |
CP_DI_OPERATION_DETAIL_CALL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Access an operation detail screen | ![]() |
![]() |
![]() |
56 | ![]() |
CP_DI_OPERATION_DETAIL_CALL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Access an operation detail screen | ![]() |
![]() |
![]() |
57 | ![]() |
CP_DI_SEQUENCE_DETAIL_CALL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Access a sequence detail screen | ![]() |
![]() |
![]() |
58 | ![]() |
CP_DI_SEQUENCE_DETAIL_CALL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Access a sequence detail screen | ![]() |
![]() |
![]() |
59 | ![]() |
CP_OV_OPR_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
60 | ![]() |
CP_OV_OPR_OVV_SCREEN_PROCESS
|
Prozessieren des Vorgangsübersichtbildes | ![]() |
![]() |
![]() |
61 | ![]() |
CP_OV_OPR_SCREEN_PROCESS
|
Darstellung von Vorgängen | ![]() |
![]() |
![]() |
62 | ![]() |
CP_OV_SEQ_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
63 | ![]() |
CP_OV_SEQ_OVV_SCREEN_PROCESS
|
Prozessieren des Folgenübersichtbildes | ![]() |
![]() |
![]() |
64 | ![]() |
CP_OV_SEQ_SCREEN_PROCESS
|
Darstellung von Folgen | ![]() |
![]() |
![]() |
65 | ![]() |
CP_OV_TSK_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
66 | ![]() |
CP_OV_TSK_OVV_SCREEN_PROCESS
|
Prozessieren des Planübersichtbildes | ![]() |
![]() |
![]() |
67 | ![]() |
CP_OV_TSK_SCREEN_PROCESS
|
Darstellung von Planköpfen | ![]() |
![]() |
![]() |
68 | ![]() |
CP_RC_CTRL_DATA_LOAD VALUE(C_OK_CODE) TYPE TC02-FCODE
|
Laden von Steuerinformationen zur Navigation | ![]() |
![]() |
![]() |
69 | ![]() |
CP_RC_DATA_LOAD VALUE(I_IDENT_SCREEN) LIKE TC02-FCODE OPTIONAL
|
Laden von Gültigkeits-, Änderungs-, und Kontextblock | ![]() |
![]() |
![]() |
70 | ![]() |
CP_RC_OK_CODE_CLA_PROVIDE VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Bereitstellen von OK-Codes für die Klassifizierung | ![]() |
![]() |
![]() |
71 | ![]() |
CP_RC_OK_CODE_LOAD VALUE(I_OK_CODE) LIKE TC02-FCODE
|
Laden des globalen OK-Codes | ![]() |
![]() |
![]() |
72 | ![]() |
CP_RC_OK_CODE_TRANSFORM VALUE(I_OK_CODE) LIKE TC02-FCODE
|
Transformation der Ok-Codes | ![]() |
![]() |
![]() |
73 | ![]() |
CP_RC_OK_CODE_TRANSFORM VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation der Ok-Codes | ![]() |
![]() |
![]() |
74 | ![]() |
CP_RC_SCREEN_INFO_PROVIDE VALUE(E_IDENT_SCREEN) LIKE TC02-FCODE
|
Bereitstellen von Informationen zum aktuellen Bild | ![]() |
![]() |
![]() |
75 | ![]() |
CP_RC_SCREEN_INFO_PROVIDE VALUE(E_IDENT_PREVIOUS_SCREEN) LIKE TC02-FCODE
|
Bereitstellen von Informationen zum aktuellen Bild | ![]() |
![]() |
![]() |
76 | ![]() |
CP_RC_STATUS_AND_TITLE_SET
|
PP-EWB: Bereitstellung von Status und Titel sowie globaler Einstellungen | ![]() |
![]() |
![]() |
77 | ![]() |
CQ_OV_CHA_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Ok-Code-Transformation für die Klasse der Prüfmerkmale | ![]() |
![]() |
![]() |
78 | ![]() |
CQ_OV_CHA_OVV_SCREEN_PROCESS
|
Über Handle in die CHA Übersicht springen | ![]() |
![]() |
![]() |
79 | ![]() |
CQ_OV_CHA_SCREEN_PROCESS
|
Darstellung von Prüfmerkmalen | ![]() |
![]() |
![]() |
80 | ![]() |
CQ_OV_CHV_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Ok-Code-Transformation für die Klasse der Prüfmerkmalswerte | ![]() |
![]() |
![]() |
81 | ![]() |
CQ_OV_CHV_OVV_SCREEN_PROCESS
|
Über Handle in die CHV Übersicht springen | ![]() |
![]() |
![]() |
82 | ![]() |
CS_OV_BOM_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
83 | ![]() |
CS_OV_BOM_OVV_SCREEN_PROCESS
|
Prozessieren der Stücklistengruppenübersicht | ![]() |
![]() |
![]() |
84 | ![]() |
CS_OV_BOM_SCREEN_PROCESS
|
Darstellung von Stücklistenköpfen | ![]() |
![]() |
![]() |
85 | ![]() |
CS_OV_ITMA_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes für Positionszuordnungen | ![]() |
![]() |
![]() |
86 | ![]() |
CS_OV_ITM_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
87 | ![]() |
CS_OV_ITM_OVV_SCREEN_PROCESS
|
Prozessieren der Positionsübersicht einer Stückliste | ![]() |
![]() |
![]() |
88 | ![]() |
CS_OV_ITM_SCREEN_PROCESS
|
Darstellung von Stücklistenpositionen | ![]() |
![]() |
![]() |
89 | ![]() |
CS_OV_MBM_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes für Material-Stücklistenzuordnungen | ![]() |
![]() |
![]() |
90 | ![]() |
CS_OV_SUI_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
EWB: Transformation des Ok-Codes bei Unterpositionen | ![]() |
![]() |
![]() |
91 | ![]() |
CZ_DI_OBJECT_LST_ALL VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Material-Alternativenzuordnung | ![]() |
![]() |
![]() |
92 | ![]() |
CZ_DI_OBJECT_LST_ALL VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Material-Alternativenzuordnung | ![]() |
![]() |
![]() |
93 | ![]() |
CZ_DI_OBJECT_LST_EDIT VALUE(IMP_DATA_PROG_IMP) LIKE TC02-CPROG DEFAULT ''
|
Material-Alternativenzuordnung | ![]() |
![]() |
![]() |
94 | ![]() |
CZ_DI_OBJECT_LST_EDIT VALUE(IMP_DATA_POOL_IMP) LIKE TC02-CPOOL DEFAULT ''
|
Material-Alternativenzuordnung | ![]() |
![]() |
![]() |
95 | ![]() |
CZ_OV_MTK_OK_CODE_PICK_TRANS VALUE(E_OK_CODE) LIKE TC02-FCODE
|
Transformation des Ok-Codes | ![]() |
![]() |
![]() |
96 | ![]() |
CZ_OV_MTK_OVV_SCREEN_PROCESS
|
Prozessieren der Übersichtsbilder | ![]() |
![]() |
![]() |
97 | ![]() |
DFPS_FCODE_HANDLING_ORDER REFERENCE(CHG_FCODE) TYPE TC02-FCODE
|
Ablaufsteuerung TST Auftrag | ![]() |
![]() |
![]() |
98 | ![]() |
DFPS_ORDER_CONFS_PROC_OK_BADI VALUE(I_UCOMM) TYPE TC02-FCODE
|
DFPS: int. SCREEN-BADI für Einzelrückmeldung IH-Auftrag - OK-Code | ![]() |
![]() |
![]() |
99 | ![]() |
EVENT_PROCESSING
|
Call up form routines for a module pool | ![]() |
![]() |
![]() |
100 | ![]() |
EVENT_PROCESSING VALUE(PANEL) LIKE TC02-PANEL DEFAULT '*'
|
Call up form routines for a module pool | ![]() |
![]() |
![]() |
101 | ![]() |
EVENT_PROCESSING VALUE(OK_CODE) LIKE TC02-FCODE
|
Call up form routines for a module pool | ![]() |
![]() |
![]() |
102 | ![]() |
EVENT_PROCESSING VALUE(OK_CODE) LIKE TC02-FCODE DEFAULT '*'
|
Call up form routines for a module pool | ![]() |
![]() |
![]() |
103 | ![]() |
EVENT_PROCESSING VALUE(BLDGR) LIKE TC02-BLDGR DEFAULT '*'
|
Call up form routines for a module pool | ![]() |
![]() |
![]() |
104 | ![]() |
EVENT_PROCESSING VALUE(AGIDV) LIKE TC02-AGIDV
|
Call up form routines for a module pool | ![]() |
![]() |
![]() |
105 | ![]() |
FUNCTION_PROCESSING
|
Call form routines for a module pool | ![]() |
![]() |
![]() |
106 | ![]() |
FUNCTION_PROCESSING VALUE(OK_CODE) LIKE TC02-FCODE
|
Call form routines for a module pool | ![]() |
![]() |
![]() |
107 | ![]() |
FUNCTION_PROCESSING VALUE(BLDGR) LIKE TC02-BLDGR DEFAULT '*'
|
Call form routines for a module pool | ![]() |
![]() |
![]() |
108 | ![]() |
FUNCTION_PROCESSING VALUE(AGIDV) LIKE TC02-AGIDV
|
Call form routines for a module pool | ![]() |
![]() |
![]() |
109 | ![]() |
FUNCTION_PROCESSING VALUE(PANEL) LIKE TC02-PANEL DEFAULT '*'
|
Call form routines for a module pool | ![]() |
![]() |
![]() |
110 | ![]() |
GET_OK_CODE_CORU_S REFERENCE(E_OK_CODE) LIKE TC02-FCODE
|
OK_CODE aus coru_s holen | ![]() |
![]() |
![]() |
111 | ![]() |
MS_PACKAGE_OK_CODE REFERENCE(E_OK_CODE) LIKE TC02-FCODE
|
Gibt den Ok-Code des Paketes an Subscreens | ![]() |
![]() |
![]() |
112 | ![]() |
MS_SUBSCREEN_OK_CODE VALUE(I_OK_CODE) LIKE TC02-FCODE
|
OK-Code an Subscreen übergeben | ![]() |
![]() |
![]() |
113 | ![]() |
PLM_PS_MAINTAIN_DATA VALUE(FCODE) LIKE TC02-FCODE
|
PLM PS: Pflege Projektstrukturen | ![]() |
![]() |
![]() |
114 | ![]() |
PS_STAT_FUNCTION_PROCESSING VALUE(BLDGR) LIKE TC02-BLDGR DEFAULT '*'
|
Aufruf von Formroutinen zu einem Modulpool (für Projekt-Statusverwaltung) | ![]() |
![]() |
![]() |
115 | ![]() |
PS_STAT_FUNCTION_PROCESSING
|
Aufruf von Formroutinen zu einem Modulpool (für Projekt-Statusverwaltung) | ![]() |
![]() |
![]() |
116 | ![]() |
PS_STAT_FUNCTION_PROCESSING VALUE(OK_CODE) LIKE TC02-FCODE
|
Aufruf von Formroutinen zu einem Modulpool (für Projekt-Statusverwaltung) | ![]() |
![]() |
![]() |
117 | ![]() |
PS_STAT_FUNCTION_PROCESSING VALUE(PANEL) LIKE TC02-PANEL DEFAULT '*'
|
Aufruf von Formroutinen zu einem Modulpool (für Projekt-Statusverwaltung) | ![]() |
![]() |
![]() |
118 | ![]() |
PS_STAT_FUNCTION_PROCESSING VALUE(AGIDV) LIKE TC02-AGIDV
|
Aufruf von Formroutinen zu einem Modulpool (für Projekt-Statusverwaltung) | ![]() |
![]() |
![]() |
119 | ![]() |
SET_OK_CODE_CORU_S REFERENCE(I_OK_CODE) LIKE TC02-FCODE
|
OK_CODE in CORU_S setzen | ![]() |
![]() |
![]() |