SAP ABAP Table WEABL_TYPE (Structure EABL)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷ IS-U-BI (Application Component) Contract Billing
⤷ EE20_JBP (Package) IS-U: Japanese Billing Preriod
⤷ IS-U-BI (Application Component) Contract Billing
⤷ EE20_JBP (Package) IS-U: Japanese Billing Preriod
Basic Data
Table Category | INTTAB | Structure |
Structure | WEABL_TYPE | Table Relationship Diagram |
Short Description | Structure EABL |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|
---|---|---|---|---|---|---|---|---|---|
1 | EABL | EABL | STRU | 0 | 0 | ||||
2 | MANDT | MANDT | MANDT | CLNT | 3 | 0 | Client | ||
3 | ABLBELNR | ABLBELNR | ABLBELNR | CHAR | 20 | 0 | Internal ID for meter reading document | ||
4 | GERNR | GERAET | GERNR | CHAR | 18 | 0 | Device | ||
5 | EQUNR | EQUNR | EQUNR | CHAR | 18 | 0 | Equipment Number | ||
6 | ZWNUMMER | E_ZWNUMMER | LFDNR3 | NUMC | 3 | 0 | Register | ||
7 | ADAT | ADAT | DATUM | DATS | 8 | 0 | Meter reading date relevant to billing | ||
8 | ATIM | ATIM | HHMM | CHAR | 4 | 0 | Meter reading time (relevant to billing) | ||
9 | V_ZWSTAND | V_ZWSTAND | V_ZWSTAND | DEC | 17 | 0 | Places Before Decimal Point in Meter Reading | ||
10 | N_ZWSTAND | N_ZWSTAND | N_ZWSTAND | DEC | 14 | 14 | Places After Decimal Point in the Meter Reading | ||
11 | V_ZWSTNDAB | V_ZWSTNDAB | V_ZWSTAND | DEC | 17 | 0 | Predecimal Places in Billed Meter Reading | ||
12 | N_ZWSTNDAB | N_ZWSTNDAB | N_ZWSTAND | DEC | 14 | 14 | Decimal Places in the Billed Meter Reading | ||
13 | MASSREAD | E_MASSREAD | MEINS | UNIT | 3 | 0 | Unit of measurement for meter reading | ||
14 | MASSBILL | E_MASSBILL | MEINS | UNIT | 3 | 0 | Unit of measurement for billing | ||
15 | STANZVOR | STANZVORE | STANZVOR | NUMC | 2 | 0 | Number of predecimal places for register | ||
16 | STANZNAC | STANZNACE | STANZNAC | NUMC | 2 | 0 | Number of decimal places for register | ||
17 | SCHAEVER | SCHAEVER | SCHAEVER | CHAR | 2 | 0 | Estimation procedure | ||
18 | SCHAEGR | SCHAEGR | SCHAEGR | CHAR | 2 | 0 | Estimation reason | ||
19 | AKTIV | E_AKTIV | E_AKTIV | CHAR | 1 | 0 | Meter reading active | ||
20 | ADATSOLL | ADATSOLL | DATUM | DATS | 8 | 0 | Scheduled meter reading date | ||
21 | ADATMAX | ADATMAX | DATUM | DATS | 8 | 0 | Date of maximum meter reading | ||
22 | ATIMMAX | ATIMMAX | HHMM | CHAR | 4 | 0 | Time of maximum meter reading | ||
23 | ADATTATS | ADATTATS | DATUM | DATS | 8 | 0 | Actual meter reading date | ||
24 | ATIMTATS | ATIMTATS | HHMM | CHAR | 4 | 0 | Actual meter reading time | ||
25 | ADATERZ | ADATERZ | DATUM | DATS | 8 | 0 | Meter reading date of implausible meter reading result | ||
26 | ATIMERZ | ATIMERZ | HHMM | CHAR | 4 | 0 | Meter reading time of implausible meter reading result | ||
27 | ADATPROG | ADATPROG | DATUM | DATS | 8 | 0 | Meter reading date from which forecast is made | ||
28 | ATIMPROG | ATIMPROG | HHMM | CHAR | 4 | 0 | Meter reading time from which consumption is determined | ||
29 | ZUORDDAT | E_ZUORDDAT | DATUM | DATS | 8 | 0 | Meter reading allocation date | ||
30 | THGDATUM | THGDATUM | DATUM | DATS | 8 | 0 | Gas allocation date | ||
31 | PRUEFZAHL | PRUEFZAHL | PRUEFZAH | NUMC | 2 | 0 | Check number | ||
32 | BAPERTYP | BAPERTYP | BAPERTYP | CHAR | 1 | 0 | Base period category | ||
33 | ABLSTAT | ABLSTAT | ABLSTAT | CHAR | 1 | 0 | Meter Reading Status | ||
34 | PRUEFPKT | PRUEFPKT | PRUEFPKT | CHAR | 2 | 0 | Independent validation | ||
35 | POPCODE | POPCODE | POPCODE | CHAR | 2 | 0 | Dependent validation | ||
36 | PRUEFTYP | PRUEFTYP | PRUEFTYP | CHAR | 1 | 0 | Validation category for meter readings | ||
37 | ABLHINW | ABLHINW | ABLHINW | CHAR | 4 | 0 | Note from meter reader | ||
38 | STABLHW | STABLHW | STABLHW | CHAR | 2 | 0 | Control of follow-up action for MR result with MR note | ||
39 | KONTRVRF | KONTRVRF | KENNZX | CHAR | 1 | 0 | Indicator: dummy record from automatic control procedure | ||
40 | ABLESART | GEPLABL | ABLESETYP | CHAR | 2 | 0 | Scheduled meter reading category | ||
41 | ABLESER | ABLESER | ABLESER | CHAR | 3 | 0 | Meter reader number | ||
42 | NACHERF | NACHERF | KENNZX | CHAR | 1 | 0 | Meter reading result inserted or modified | ||
43 | MDENR | MDENR | MDENR | NUMC | 3 | 0 | Number for mobile data entry (MDE) | ||
44 | MDEUPL | MDEDOWN | CHAR | 1 | 0 | Order has been output | |||
45 | E_ZEITVBL | E_ZEITVBL | KENNZX | CHAR | 1 | 0 | Multiple meter reading order creation | ||
46 | E_ZVLZUORD | E_ZVLZUORD | ANZAHL3 | NUMC | 3 | 0 | Multiple allocation | ||
47 | STEUERGRP | STEUERGRP | STEUERGRP | CHAR | 4 | 0 | Control group for multiple meter reading order creation | ||
48 | ARBAUF | ARBAUF | KENNZX | CHAR | 1 | 0 | Control Meter Reading Order ID Printed | ||
49 | KSTATUS | E_KSTATUS | E_KSTATUS | CHAR | 1 | 0 | Status for automatic monitoring of meter reading order | ||
50 | .INCLUDE | 0 | 0 | Creation and Change Data | |||||
51 | ERDAT | ERDAT | DATUM | DATS | 8 | 0 | Date on which the record was created | ||
52 | ERNAM | ERNAM | USNAM | CHAR | 12 | 0 | Name of Person who Created the Object | ||
53 | AEDAT | AEDAT | DATUM | DATS | 8 | 0 | Last Changed On | ||
54 | AENAM | AENAM | USNAM | CHAR | 12 | 0 | Name of Person Who Changed Object | ||
55 | ENTRYNUMB | ENTRYNUMB | NUM08 | NUMC | 8 | 0 | Entry number for fast entry | ||
56 | ACTOR | HROBJEC_14 | HROBJEC_14 | CHAR | 14 | 0 | Concatenated Identification (Type and ID) of Org.Objects | ||
57 | ISTABLART | ISTABLART | ISTABLART | CHAR | 2 | 0 | Meter reading type | ||
58 | ABLESTYP | ABLESTYP | ABLESETYP | CHAR | 2 | 0 | Meter reading category | ||
59 | E_ZVBL_BEZDAT | E_ZVBL_BEZDAT | DATUM | DATS | 8 | 0 | Scheduled meter reading date for base meter reading | ||
60 | SM_AUFNR | PM_SVCNR | PMSVCNR | CHAR | 12 | 0 | Service order or notification | ||
61 | DOC_TYPE | KZ_SM_DOC_TYPE | KZ_SM_DOC_TYPE | CHAR | 1 | 0 | Document category for plant maintenance and customer service | ||
62 | .INCLUDE | 0 | 0 | Special EABL Fields for JBP (Japanese Billing Period) | |||||
63 | ADATREAL | ADATREAL | DATUM | DATS | 8 | 0 | [JBP] Real Meter Reading Date | ||
64 | ATIMREAL | ATIMREAL | HHMM | CHAR | 4 | 0 | [JBP] Real Meter Reading Time | ||
65 | S_ISTABLART | S_ISTABLART | ISTABLART | CHAR | 2 | 0 | [JBP] Meter Reading Type for Original Meter Reading | ||
66 | S_AKTIV | S_AKTIV | E_AKTIV | CHAR | 1 | 0 | [JBP] Orig. Meter Reading: Meter Reading Active | ||
67 | S_ABLSTAT | S_ABLSTAT | ABLSTAT | CHAR | 1 | 0 | [JBP] Original Meter Reading Status | ||
68 | S_V_ZWSTAND | S_V_ZWSTAND | V_ZWSTAND | DEC | 17 | 0 | [JBP] Orig. MR: Decimal Places Before Meter reading | ||
69 | S_N_ZWSTAND | S_N_ZWSTAND | N_ZWSTAND | DEC | 14 | 14 | [JBP] Decimal Places of Meter Readings for Original MR | ||
70 | S_V_ZWSTNDAB | S_V_ZWSTNDAB | V_ZWSTAND | DEC | 17 | 0 | [JBP] Predecimal Places of Billed MR for Original MR | ||
71 | S_N_ZWSTNDAB | S_N_ZWSTNDAB | N_ZWSTAND | DEC | 14 | 14 | [JBP] Decimal Places of Billed Orginal Meter Reading | ||
72 | REMOVED | REMOVED | REMOVED | CHAR | 1 | 0 | [JBP] Status Indicator: MR Result Suppressed | ||
73 | BP | BP | BP | CHAR | 1 | 0 | Selection of Billing Period: Standard or JBP | ||
74 | REM_ABLBELNR | REM_ABLBELNR | ABLBELNR | CHAR | 20 | 0 | [JBP] Suppressed MR Document Number | ||
75 | REM_ABLESER | R_ABLESER | ABLESER | CHAR | 3 | 0 | Meter Reader Number of Suppressed Meter Reading | ||
76 | S_ADATSOLL | ADATSOLL | DATUM | DATS | 8 | 0 | Scheduled meter reading date | ||
77 | S_ZVBL_BEZDAT | E_ZVBL_BEZDAT | DATUM | DATS | 8 | 0 | Scheduled meter reading date for base meter reading | ||
78 | .INCLUDE | 0 | 0 |
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in | 471 |