SAP ABAP Table CCIHS_MJIOT (EHS: IOTAB for Measurements (CCIHT_MJ))
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
EHS-IHS (Application Component) Industrial Hygiene and Safety
⤷
CBIH (Package) EH&S: Industrial Hygiene and Safety
⤷
⤷
Basic Data
| Table Category | INTTAB | Structure |
| Structure | CCIHS_MJIOT |
|
| Short Description | EHS: IOTAB for Measurements (CCIHT_MJ) |
Delivery and Maintenance
| Pool/cluster | ||
| Delivery Class | ||
| Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
| |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|---|---|---|---|---|---|---|---|---|---|
| 1 | |
0 | 0 | EHS: Standard fields for IOTABs (step loop library) | |||||
| 2 | |
ESEMARKFLG | ESDFLAG | CHAR | 1 | 0 | Row Is Selected | ||
| 3 | |
ESESELEFLG | ESDFLAG | CHAR | 1 | 0 | Step Loop Line Selected | ||
| 4 | |
ESECOUNTER | NUMC10 | NUMC | 10 | 0 | General Auxiliary Counter | ||
| 5 | |
ESELINEMOD | CHAR1 | CHAR | 1 | 0 | Processing status or mode of a record/step loop line | ||
| 6 | |
ESECHCOFLG | ESDFLAG | CHAR | 1 | 0 | Indicator: Change number collision | ||
| 7 | |
ESELOCKMOD | CHAR1 | CHAR | 1 | 0 | Lock Mode (Shared, Exclusive) | ||
| 8 | |
ESEINTRFLG | ESDFLAG | CHAR | 1 | 0 | Flag for Internal Use | ||
| 9 | |
0 | 0 | EHS: Measurement | |||||
| 10 | |
0 | 0 | EHS: Structure for key info of master data | |||||
| 11 | |
MANDT | MANDT | CLNT | 3 | 0 | Client | T000 | |
| 12 | |
ESERECN | ESDRECN | NUMC | 20 | 0 | Sequential Number of Data Record | ||
| 13 | |
ESEACTN | ESDACTN | NUMC | 20 | 0 | Sequential Number of the Change State | ||
| 14 | |
0 | 0 | EHS: Structure for General Administration Information | |||||
| 15 | |
ESEVALFR | DATUM | DATS | 8 | 0 | Valid-From Date | ||
| 16 | |
ESEVALTO | DATUM | DATS | 8 | 0 | Valid-To Date | ||
| 17 | |
ESEAENNR | AENNR | CHAR | 12 | 0 | Change Number | AENR | |
| 18 | |
ESEDELFLG | ESDFLAG | CHAR | 1 | 0 | Deletion Indicator | ||
| 19 | |
ESEPARKFLG | ESDFLAG | CHAR | 1 | 0 | Data Record Is Inactive | ||
| 20 | |
ESECRDAT | DATUM | DATS | 8 | 0 | Created On | ||
| 21 | |
ESECRNAM | USNAM | CHAR | 12 | 0 | Created By | ||
| 22 | |
ESEUPDDAT | DATUM | DATS | 8 | 0 | Changed On | ||
| 23 | |
ESEUPDNAM | USNAM | CHAR | 12 | 0 | Last Changed By | ||
| 24 | |
ESESRSID | ESDSRSID | CHAR | 10 | 0 | Source of Data | TCG56 | |
| 25 | |
ESEVENDRID | AD_ADDRNUM | CHAR | 10 | 0 | Data Provider | * | |
| 26 | |
ESERECN | ESDRECN | NUMC | 20 | 0 | Sequential Number of Data Record | ||
| 27 | |
J_OBJNR | J_OBJNR | CHAR | 22 | 0 | Object number | * | |
| 28 | |
CCIHE_MJID | CCIHD_MJID | CHAR | 30 | 0 | Measurement Number | ||
| 29 | |
CCIHE_MJCAT | CCIHD_MJCAT | CHAR | 3 | 0 | Sampling Type | CCIHC_MJCAT | |
| 30 | |
EHSBE_STATUS | J_STATUS | CHAR | 5 | 0 | Status | ||
| 31 | |
CCIHE_EPTYPE | ESDSUBCAT | CHAR | 10 | 0 | Agent Type | CCIHV_HAZTYPE | |
| 32 | |
CCIHE_EPID | CCIHD_EPID | CHAR | 20 | 0 | Agent | ||
| 33 | |
CCIHE_RECNTMPWA | ESDRECN | NUMC | 20 | 0 | Reference to Assigned Work Area | ||
| 34 | |
CCIHE_MJVALFR | DATUM | DATS | 8 | 0 | Start of Validity of Measurement | ||
| 35 | |
CCIHE_MJVALTO | DATUM | DATS | 8 | 0 | End of Validity of Measurement | ||
| 36 | |
CCIHE_MSRBGNDATE | DATUM | DATS | 8 | 0 | Date of Start of Measurement | ||
| 37 | |
CCIHE_MSRBGNTIME | UZEIT | TIMS | 6 | 0 | Time of Start of Measurement | ||
| 38 | |
CCIHE_MSRENDDATE | DATUM | DATS | 8 | 0 | Date of End of Measurement | ||
| 39 | |
CCIHE_MSRENDTIME | UZEIT | TIMS | 6 | 0 | Time of End of Measurement | ||
| 40 | |
CCIHE_MDURATION | CCIHD_MDURATION | TIMS | 6 | 0 | Actual Duration of Measurement | ||
| 41 | |
CCIHE_MPLDURATION | CCIHD_MDURATION | TIMS | 6 | 0 | Planned Measurement Duration | ||
| 42 | |
CCIHE_MEXCHANGE | ESDFLAG | CHAR | 1 | 0 | Perform Conversion | ||
| 43 | |
CCIHE_MSOURCEID | CCIHD_MSOURCEID | CHAR | 3 | 0 | Sampling Location | CCIHC_MSOURCE | |
| 44 | |
CCIHE_MSOURCENOTE | CCIHD_MSOURCENOTE | CHAR | 255 | 0 | Description for Sampling Location | ||
| 45 | |
CCIHE_FIXLOCFLG | ESDFLAG | CHAR | 1 | 0 | Fixed-Location Measurement | ||
| 46 | |
CCIHE_MPERIOD | CCIHD_MPERIOD | NUMC | 2 | 0 | Repetition of Measurement in Months | ||
| 47 | |
CCIHE_FLOW | CCIHD_FLOW | DEC | 5 | 2 | Flow Quantity of Measuring Device | ||
| 48 | |
CCIHE_FLOWUNIT | MEINS | UNIT | 3 | 0 | Flow Unit | * | |
| 49 | |
CCIHE_DVNR | CHAR20 | CHAR | 20 | 0 | Number of the Measuring Device | ||
| 50 | |
CCIHE_DVTYPE | CCIHD_DVTYPE | CHAR | 3 | 0 | Measuring Device Type | CCIHC_DVTYPE | |
| 51 | |
CCIHE_METHOD | CCIHD_METHOD | CHAR | 5 | 0 | Measurement Method | CCIHC_METHOD | |
| 52 | |
CCIHE_MJPERSON | CCIHD_MJPERSON | CHAR | 10 | 0 | Test Person | ||
| 53 | |
CCIHE_PERSGRP | CCIHD_PERSGRP | CHAR | 1 | 0 | Person Group | ||
| 54 | |
CCIHE_FULLNAME | TEXT80 | CHAR | 80 | 0 | Full Name of Person | ||
| 55 | |
CCIHE_MJNOTE | CCIHD_MNOTE | CHAR | 72 | 0 | Remarks on Measurement | ||
| 56 | |
ESELTXTFLG | ESDFLAG | CHAR | 1 | 0 | Long Text | ||
| 57 | |
CCIHE_MJNOTE | CCIHD_MNOTE | CHAR | 72 | 0 | Remarks on Measurement | ||
| 58 | |
ESELTXTFLG | ESDFLAG | CHAR | 1 | 0 | Long Text | ||
| 59 | |
CCIHE_RESPIRATOR | CCIHD_RESPIRATOR | CHAR | 1 | 0 | Respiratory Protection | ||
| 60 | |
CCIHE_SAMPLENR | CCIHD_SAMPLENR | CHAR | 30 | 0 | Container or Filter | ||
| 61 | |
CCIHE_MPCOSTAC | KOSTL | CHAR | 10 | 0 | Cost Center for Measurement Project | * | |
| 62 | |
CCIHE_MPCTRAREA | CACCD | CHAR | 4 | 0 | Controlling Area | TKA01 | |
| 63 | |
CCIHE_RECNTREFMJ | ESDRECN | NUMC | 20 | 0 | Reference to Partial Measurement | ||
| 64 | |
CCIHE_LIMEXCEEDFLG | ESDFLAG | CHAR | 1 | 0 | Reference Value Exceeded | ||
| 65 | |
CCIHE_STMFLG | ESDFLAG | CHAR | 1 | 0 | Short-Term Sample | ||
| 66 | |
CCIHE_MCOSTS | CCIHD_METCOASTS | CURR | 10 | 2 | Cost of Analysis | ||
| 67 | |
CCIHE_METCUKY | WAERS | CUKY | 5 | 0 | Currency Key for Costs | * | |
| 68 | |
CCIHE_VOLUME | FLTP | FLTP | 16 | 16 | Total Volume in Liters | ||
| 69 | |
CCIHE_HQVALDECIMALS | INT4 | INT4 | 10 | 0 | Decimal Places for a Measured Physical Variable Value | ||
| 70 | |
CCIHE_MPCOCODE | BUKRS | CHAR | 4 | 0 | Company Code | * | |
| 71 | |
CCIHE_FLGEXPLCK | ESDFLAG | CHAR | 1 | 0 | Object Is in Export | ||
| 72 | |
CCIHE_OPCOND | CCIHD_OPCOND | CHAR | 3 | 0 | Operation Status of Work Area/Pattern | CCIHC_OC01 | |
| 73 | |
CCIHE_MSRPLBEGDATE | DATUM | DATS | 8 | 0 | Planned Measurement Start Date | ||
| 74 | |
CCIHE_MSRPLENDDATE | DATUM | DATS | 8 | 0 | Planned Measurement End Date | ||
| 75 | |
CCIHE_MSRTEMP | DEC5_2 | DEC | 7 | 2 | Temperature During Measurement | ||
| 76 | |
CCIHE_MSRTEMPUNIT | MEINS | UNIT | 3 | 0 | Temperature Unit During Measurement | * | |
| 77 | |
CCIHE_AIRHUM | DEC5_2 | DEC | 7 | 2 | Air Humidity During Measurement | ||
| 78 | |
CCIHE_AIRHUMUNIT | MEINS | UNIT | 3 | 0 | Air Humidity Unit During Measurement | * | |
| 79 | |
CCIHE_AIRCOND | CHAR21 | CHAR | 21 | 0 | Ventilation During Measurement | ||
| 80 | |
CCIHE_AIRCHNGRATE | DECV5_2 | DEC | 5 | 2 | Air Change Rate During Measurement | ||
| 81 | |
CCIHE_PROTEQUI | CHAR21 | CHAR | 21 | 0 | Safety Device During Measurement | ||
| 82 | |
CCIHE_FLG_NIGHT | ESDFLAG | CHAR | 1 | 0 | Night Measurement | ||
| 83 | |
CCIHE_MSRPLBEGTIME | UZEIT | TIMS | 6 | 0 | Planned Measurement Start Time | ||
| 84 | |
CCIHE_MSRPLENDTIME | UZEIT | TIMS | 6 | 0 | Planned Measurement End Time | ||
| 85 | |
CCIHE_MJCATTXT | TEXT60 | CHAR | 60 | 0 | Description of Sampling Type | ||
| 86 | |
J_TXT04 | TEXT4 | CHAR | 4 | 0 | Individual status of an object (short form) | ||
| 87 | |
J_TXT30 | TEXT30 | CHAR | 30 | 0 | Object status | ||
| 88 | |
CCIHE_EPTYPENAM | TEXT40 | CHAR | 40 | 0 | Description of Agent Type | ||
| 89 | |
CCIHE_EPNAM | TEXT60 | CHAR | 60 | 0 | Description of Agent | ||
| 90 | |
CCIHE_MSOURCE | CCIHD_MSOURCE | CHAR | 120 | 0 | Description of Sampling Location | ||
| 91 | |
CCIHE_DVTYPETXT | TEXT60 | CHAR | 60 | 0 | Description of Measuring Device Type | ||
| 92 | |
CCIHE_METHODTXT | TEXT60 | CHAR | 60 | 0 | Description of Measurement Method | ||
| 93 | |
CCIHE_COSTCNAM | CHAR20 | CHAR | 20 | 0 | Description of Cost Center | ||
| 94 | |
CCIHE_MJID | CCIHD_MJID | CHAR | 30 | 0 | Measurement Number | ||
| 95 | |
CCIHE_WAID | CCIHD_WAID | CHAR | 20 | 0 | Work Area or Pattern | ||
| 96 | |
CCIHE_WANAM | TEXT60 | CHAR | 60 | 0 | Language-Dependent Description of Work Area/Pattern | ||
| 97 | |
CCIHE_RECNTWAH | ESDRECN | NUMC | 20 | 0 | Reference to Work Area | ||
| 98 | |
CCIHE_WAID | CCIHD_WAID | CHAR | 20 | 0 | Work Area or Pattern | ||
| 99 | |
CCIHE_WANAM | TEXT60 | CHAR | 60 | 0 | Language-Dependent Description of Work Area/Pattern | ||
| 100 | |
CCIHE_RECNTWAH | ESDRECN | NUMC | 20 | 0 | Reference to Work Area | ||
| 101 | |
CCIHE_BUILDINGS | CCIHD_BUILDINGS | CHAR | 120 | 0 | Building | ||
| 102 | |
CCIHE_ANLAB | BU_PARTNER | CHAR | 10 | 0 | Analysis Laboratory | * | |
| 103 | |
CCIHE_ANLABNAM | BU_NAME | CHAR | 40 | 0 | Description of Analysis Lab | ||
| 104 | |
CCIHE_METINSTRUCT | CCIHD_METINSTRUCT | CHAR | 132 | 0 | Instructions for Measurement Method | ||
| 105 | |
CCIHE_MPTYPE | CCIHD_MPTYPE | CHAR | 3 | 0 | Measurement Project Type | * | |
| 106 | |
CCIHE_EPQUNITNAM | MSEH6 | CHAR | 6 | 0 | Unit of Measurement | ||
| 107 | |
CCIHE_VOLUME_CHAR | CHAR12 | CHAR | 12 | 0 | Total Volume in Liters | ||
| 108 | |
CCIHE_MDURATION_MIN | CHAR4 | CHAR | 4 | 0 | Actual Measurement Duration (in Minutes) | ||
| 109 | |
CCIHE_MPLDURATION_MIN | CHAR4 | CHAR | 4 | 0 | Planned Measurement Duration in Minutes | ||
| 110 | |
CCIHE_CTRAREANAM | TEXT25 | CHAR | 25 | 0 | Description of Controlling Area | ||
| 111 | |
CCIHE_OPCONDTXT | TEXT30 | CHAR | 30 | 0 | Description of Operation Status | ||
| 112 | |
CCIHE_AIRCONDTXT | TEXT132 | CHAR | 132 | 0 | Description of Ventilation During Measurement | ||
| 113 | |
CCIHE_PROTEQUITXT | TEXT132 | CHAR | 132 | 0 | Name of Safety Device During Measurement | ||
| 114 | |
CCIHE_FLOWUNITNAM | MSEH6 | CHAR | 6 | 0 | Flow Unit | CCIHV_UNIT | |
| 115 | |
CCIHE_MSRTEMPUNITNAM | MSEH6 | CHAR | 6 | 0 | Temperature Unit During Measurement | CCIHV_UNIT | |
| 116 | |
CCIHE_AIRHUMUNITNAM | MSEH6 | CHAR | 6 | 0 | Air Humidity Unit During Measurement | CCIHV_UNIT |
Foreign Keys
| |
Source Table | Source Column | Foreign Table | Foreign Column | Dependency Factor | Cardinality left | Cardinality right |
|---|---|---|---|---|---|---|---|
| 1 | CCIHS_MJIOT | AENNR | |
|
REF | 1 | CN |
| 2 | CCIHS_MJIOT | AIRHUMUNITNAM | |
|
REF | 1 | CN |
| 3 | CCIHS_MJIOT | EPTYPE | |
|
|||
| 4 | CCIHS_MJIOT | FLOWUNITNAM | |
|
REF | 1 | CN |
| 5 | CCIHS_MJIOT | MANDT | |
|
|||
| 6 | CCIHS_MJIOT | MDEVTYPE | |
|
KEY | 1 | CN |
| 7 | CCIHS_MJIOT | METHOD | |
|
1 | CN | |
| 8 | CCIHS_MJIOT | MJCAT | |
|
|||
| 9 | CCIHS_MJIOT | MJCTRAREA | |
|
|||
| 10 | CCIHS_MJIOT | MSOURCEID | |
|
|||
| 11 | CCIHS_MJIOT | MSRTEMPUNITNAM | |
|
REF | 1 | CN |
| 12 | CCIHS_MJIOT | OPCOND | |
|
REF | 1 | CN |
| 13 | CCIHS_MJIOT | SRSID | |
|
REF | 1 | CN |
History
| Last changed by/on | SAP | 20110901 |
| SAP Release Created in |