Where Used List (Class) for SAP ABAP Class CL_FRML_CALC_SPC_IO (Formula Calculations Input/Output)
SAP ABAP Class
CL_FRML_CALC_SPC_IO (Formula Calculations Input/Output) is used by
# | Object Type | Object Name | Object Description | Package | Structure Package | Software Component |
---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |
||
1 | ![]() |
CL_DEF_IM_BADI_FRML_CALC Method: IF_EX_BADI_FRML_CALC~CALCULATE_FORMULA
|
Default Implementation for BAdI Definition BADI_FRML_CALC | ![]() |
![]() |
![]() |
2 | ![]() |
CL_FRML_CALC_SERVICE Method: EXPLODE_INTO_COSTS
|
Material Staging | ![]() |
![]() |
![]() |
3 | ![]() |
CL_FRML_CALC_SPC_IO | Formula Calculations Input/Output | ![]() |
![]() |
![]() |
4 | ![]() |
CL_FRML_CALC_SPC_IO Method: CHECK_PROPOR_UNITS
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
5 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PROPORTION_MULTIPLE
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
6 | ![]() |
CL_FRML_CALC_SPC_IO Method: SUM_UP_REF_QTY
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
7 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_SUMS
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
8 | ![]() |
CL_FRML_CALC_SPC_IO Method: CLASS_CONSTRUCTOR
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
9 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PO_EVAPORATION
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
10 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PO_EVAP_VALUES_FROM_VOL
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
11 | ![]() |
CL_FRML_CALC_SPC_IO | Formula Calculations Input/Output | ![]() |
![]() |
![]() |
12 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_ITEM
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
13 | ![]() |
CL_FRML_CALC_SPC_IO Method: GET_UNITS
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
14 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_RATIO
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
15 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PERCENTAGE_OF_EVAP
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
16 | ![]() |
CL_FRML_CALC_SPC_IO Method: INVERT_2ND_OUT_NEG_INP
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
17 | ![]() |
CL_FRML_CALC_SPC_IO Method: CONVERT_TO_DIALOG_FORMAT
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
18 | ![]() |
CL_FRML_CALC_SPC_IO Method: DETERMINE_EVAP_DENSITY
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
19 | ![]() |
CL_FRML_CALC_SPC_IO Method: CHECK_PROPERTY_CHANGED
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
20 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PRIMARY_OUTPUT_SPEC
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
21 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALCULATE_PRIMARY_OUTPUT
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
22 | ![]() |
CL_FRML_CALC_SPC_IO Method: LAUNCH_CALC_ITEM
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
23 | ![]() |
CL_FRML_CALC_SPC_IO Method: CONVERT_QTY_VIA_EXIT
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
24 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PACKAGING_FACTOR
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
25 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_RECON_RATE
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
26 | ![]() |
CL_FRML_CALC_SPC_IO Method: BUILT_CALC_CTRL_LMTS
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
27 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_LOSS_PERCENT
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
28 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PO_REACTION
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
29 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_ITQ_BPO
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
30 | ![]() |
CL_FRML_CALC_SPC_IO Method: LAUNCH_CALC_OUTPUT
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
31 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PO_NORMAL
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
32 | ![]() |
CL_FRML_CALC_SPC_IO Method: CALC_PO_EVAP_VALUES_FROM_MASS
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
33 | ![]() |
CL_FRML_CALC_SPC_IO Method: BUILT_CALC_CTRL_QTY
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
34 | ![]() |
CL_FRML_CALC_SPC_IO Method: ADD_UNIT
|
Formula Calculations Input/Output | ![]() |
![]() |
![]() |
35 | ![]() |
CL_FRML_CALC_SPC_IO_MAIN Method: IF_FRML_CALC_IO_FIELDS~CALC_FIELD
|
Calculation of Formula Fields | ![]() |
![]() |
![]() |
36 | ![]() |
CL_FRML_CALC_SPC_IO_VOL Method: IF_FRML_CALC_IO_FIELDS~CALC_FIELD
|
Calculation of Volume Field | ![]() |
![]() |
![]() |
37 | ![]() |
CL_FRML_CALC_SPC_IO_VOL_OVR Method: IF_FRML_CALC_IO_FIELDS~CALC_FIELD
|
Calculation of Aeration Volume | ![]() |
![]() |
![]() |
38 | ![]() |
CL_FRML_CHECK_ADAPT_HEADER Method: CHECK_INP_TGT_QTY
|
Checks/Adjustments for Formula Header Data | ![]() |
![]() |
![]() |
39 | ![]() |
CL_FRML_CHECK_ADAPT_HEADER Method: CHECK_UNIT
|
Checks/Adjustments for Formula Header Data | ![]() |
![]() |
![]() |
40 | ![]() |
CL_FRML_CHECK_ADAPT_ITEM Method: FIELD_UNIT
|
Checks/Adjustments for Formula Input/Output Items | ![]() |
![]() |
![]() |
41 | ![]() |
CL_FRML_CMP_MAPPING Method: MAP_SYNC_IO_LINE
|
Mapping for Compositions | ![]() |
![]() |
![]() |