Hierarchy
⤷
⤷
Properties
| Class | CL_FRML_CHECK_ADAPT_ITEM | |
| Short Description | Checks/Adjustments for Formula Input/Output Items | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | RMINT | |
| Program status | ||
| Category | 0 | |
| Package | RMSFRMSPC | RMS-FRM: RMS Formula - Specification Database |
| Created | 20060720 | SAP |
| Last change | 20110908 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 4 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 5 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_FRML_CHECK_ADAPT_ITEM has no interface implemented.
Friends
Class CL_FRML_CHECK_ADAPT_ITEM has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Private | Type reference (TYPE) | ARBGB | 'C§' | Message Class EH&S | 20061016 | ||
| 2 | Constant | Private | Type reference (TYPE) | ARBGB | 'D9' | Message Class EH&S | 20061016 | ||
| 3 | Constant | Public | Type reference (TYPE) | FLAG | ' ' | False | 20060720 | ||
| 4 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'COMPLOW' | Item Field Name | 20060720 | ||
| 5 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'COMPTGT' | Item Field Name | 20060720 | ||
| 6 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'COMPUPP' | Item Field Name | 20060720 | ||
| 7 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'EXCVAL' | Item Field Name | 20060720 | ||
| 8 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'FLG_OUT' | Item Field Name | 20060921 | ||
| 9 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'MATNR' | Item Field Name | 20060720 | ||
| 10 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'OPLOW' | Item Field Name | 20060720 | ||
| 11 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'OPUP' | Item Field Name | 20060720 | ||
| 12 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'OVR_FACTOR' | Item Field Name | 20060720 | ||
| 13 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'POSNR' | Item Field Name | 20060720 | ||
| 14 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'PO_FLG' | Item Field Name | 20060921 | ||
| 15 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'ROLE' | Item Field Name | 20060720 | ||
| 16 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'STD_ALT_FLG' | Item Field Name | 20061108 | ||
| 17 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'STREAM_ID' | Item Field Name | 20060921 | ||
| 18 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'SUBID' | Item Field Name | 20060720 | ||
| 19 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'SUBRECN' | Item Field Name | 20060823 | ||
| 20 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'TS_PERCENT' | Item Field Name | 20060720 | ||
| 21 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'TS_QTY' | Item Field Name | 20060720 | ||
| 22 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'TS_UNIT' | Item Field Name | 20060720 | ||
| 23 | Constant | Private | Type reference (TYPE) | FIELDNAME | 'UNIT' | Item Field Name | 20060720 | ||
| 24 | Constant | Private | Type reference (TYPE) | ESEPRECL | '>=' | Operator: Greater Than or Equal to | 20061031 | ||
| 25 | Constant | Private | Type reference (TYPE) | ESEPRECL | '>' | Operator: Greater Than | 20061031 | ||
| 26 | Constant | Private | Type reference (TYPE) | ESEPRECU | '<=' | Operator: Less Than or Equal to | 20061031 | ||
| 27 | Constant | Private | Type reference (TYPE) | ESEPRECU | '<' | Operator: Less Than | 20061031 | ||
| 28 | Constant | Public | Type reference (TYPE) | FLAG | 'X' | True | 20060720 | ||
| 29 | Static Attribute | Private | Type reference (TYPE) | FRMLTY_ALLOWED_UNITS | Table of Permitted Units of Measure | 20060720 | |||
| 30 | Static Attribute | Private | Type reference (TYPE) | LVC_T_STYL | All Fields of Alternatives from Customizing | 20060919 | |||
| 31 | Static Attribute | Private | Type reference (TYPE) | RMSTT_FNAME | Key Fields for Key Field Check | 20060921 | |||
| 32 | Static Attribute | Private | Type reference (TYPE) | FRMLE_FUNCNAME | Function Module: Item Check After | 20060720 | |||
| 33 | Static Attribute | Private | Type reference (TYPE) | FRMLE_FUNCNAME | Function Module: Item Check Before | 20060720 | |||
| 34 | Static Attribute | Private | Type reference (TYPE) | FRMLE_FUNCNAME | Function Module: Item Check All | 20060720 | |||
| 35 | Static Attribute | Private | Type reference (TYPE) | FLAG | Indicator: 'X' = Include Material Units | 20060918 | |||
| 36 | Static Attribute | Private | Type reference (TYPE) | I | Error messages counter | 20060720 | |||
| 37 | Static Attribute | Private | Type reference (TYPE) | MSEHI | Default Unit | 20060720 | |||
| 38 | Static Attribute | Private | Type reference (TYPE) | DIMID | Default Dimension | 20060720 | |||
| 39 | Static Attribute | Private | Type reference (TYPE) | FRMLE_ROLE_EVENT | Event LOM -> LORS | 20060831 | |||
| 40 | Static Attribute | Private | Type reference (TYPE) | FRMLE_ROLE_EVENT | Event LORS -> LOM | 20060831 | |||
| 41 | Static Attribute | Private | Type reference (TYPE) | SYCHAR255 | Dummy Variable for Internal Message Output | 20060720 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Static method | Public | Method | Transfer Fields from Leading Item to Alternatives | 20060901 | |
| 2 | Static method | Private | Method | Call Customer Check Function | 20060720 | |
| 3 | Static method | Public | Method | Call Customer Check Function: After Standard Check | 20060720 | |
| 4 | Static method | Public | Method | Call Customer Check Function: Before Standard Check | 20060720 | |
| 5 | Static method | Public | Method | Call Customer Check Function: For All Items | 20060720 | |
| 6 | Static method | Public | Constructor | CLASS_CONSTRUCTOR | 20060720 | |
| 7 | Static method | Private | Method | Adjust Fields Dependent on COMPTGT / UNIT | 20060901 | |
| 8 | Static method | Public | Method | Field Check: Quantity + Limit Values and Operators | 20061017 | |
| 9 | Static method | Public | Method | Field Check: Material + Substance | 20060901 | |
| 10 | Static method | Public | Method | Field Check: Component Type + Material + Substance | 20060901 | |
| 11 | Static method | Private | Method | Adjust Fields Dependent on TS_QTY / TS_UNIT | 20060901 | |
| 12 | Static method | Public | Method | Field Check: Item Quantity | 20060901 | |
| 13 | Static method | Public | Method | Field Check: Exception Value | 20060901 | |
| 14 | Static method | Public | Method | Field Check: Output Indicator | 20061017 | |
| 15 | Static method | Public | Method | Field Check: Material Number | 20060901 | |
| 16 | Static method | Public | Method | Field Check: Overrun Factor (Aeration) | 20060901 | |
| 17 | Static method | Public | Method | Field Check: Item Number | 20060901 | |
| 18 | Static method | Public | Method | Field Check: Primary Output Indicator | 20060922 | |
| 19 | Static method | Public | Method | Field Check: Component Type | 20060901 | |
| 20 | Static method | Public | Method | Field Check: Substance | 20060901 | |
| 21 | Static method | Public | Method | Field Check: Proportion of Total Solids | 20060901 | |
| 22 | Static method | Public | Method | Field Check: Total Solids | 20060901 | |
| 23 | Static method | Public | Method | Field Check: Unit of Measure of Total Solids | 20060901 | |
| 24 | Static method | Public | Method | Field Check: Unit of Measure of Item | 20060901 | |
| 25 | Static method | Private | Method | Field Check: Unit of Measure with Material | 20060918 | |
| 26 | Static method | Private | Method | Permitted Units Including Material Units | 20060918 | |
| 27 | Static method | Private | Method | Determines Changeable Fields of Alternatives | 20060918 | |
| 28 | Static method | Public | Method | Transfer Fields from Leading Item to Group Item | 20060901 | |
| 29 | Static method | Public | Method | Check Different Flags for Each Item | 20061108 | |
| 30 | Static method | Public | Method | Final Adjustments to All Items | 20060920 | |
| 31 | Static method | Public | Method | Previous Adjustments to All Items | 20060920 | |
| 32 | Static method | Public | Method | Set Default Values for Empty Item Fields | 20060901 | |
| 33 | Static method | Public | Method | Checks for Item to Be Deleted | 20060901 | |
| 34 | Static method | Public | Method | Checks for New Item | 20060901 | |
| 35 | Static method | Public | Method | Field Checks for Changed, Single Item | 20060901 | |
| 36 | Static method | Public | Method | Check Key Fields for Uniqueness | 20060915 | |
| 37 | Static method | Private | Method | Check Whether Subst. Required for Mat. or Mat. for Subst. | 20060901 | |
| 38 | Static method | Public | Method | Determines Non-Permitted Item Numbers of All Change States | 20060720 | |
| 39 | Static method | Public | Method | Required Entry Field Check | 20060915 | |
| 40 | Static method | Private | Method | Determine Default Values for Units | 20060918 |
Events
Class CL_FRML_CHECK_ADAPT_ITEM has no event.
Types
Class CL_FRML_CHECK_ADAPT_ITEM has no local type.
Method Signatures
Method ALTERNATIVES_ADAPT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_ITEM_PARENT | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Führende Position (Vater) | 20060919 | |||
| 2 | XS_ITEM_CHILD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Alternativ Position (Kind) | 20060919 |
Method ALTERNATIVES_ADAPT on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method CALL_CUSTOMER_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060720 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060720 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060720 | |||
| 4 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060720 | |||
| 5 | I_CHECK_FUNCTION | Call by reference | Type reference (TYPE) | FRMLE_FUNCNAME | Name Prüffunktion | 20060720 | |||
| 6 | I_FIELDNAME | Call by reference | Type reference (TYPE) | LVC_FNAME | Name Feld, das geändert wurde | 20060720 | |||
| 7 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060720 | |||
| 8 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060720 |
Method CALL_CUSTOMER_CHECK on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method CALL_CUSTOMER_CHECK_AFTER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060720 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060720 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060720 | |||
| 4 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060720 | |||
| 5 | I_FIELDNAME | Call by reference | Type reference (TYPE) | LVC_FNAME | Name Feld, das geändert wurde | 20060720 | |||
| 6 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060720 | |||
| 7 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060720 |
Method CALL_CUSTOMER_CHECK_AFTER on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method CALL_CUSTOMER_CHECK_PRE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060720 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060720 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060720 | |||
| 4 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060720 | |||
| 5 | I_FIELDNAME | Call by reference | Type reference (TYPE) | LVC_FNAME | Name Feld, das geändert wurde | 20060720 | |||
| 6 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060720 | |||
| 7 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060720 |
Method CALL_CUSTOMER_CHECK_PRE on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method CALL_CUSTOMER_CHECK_TOTAL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060720 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060720 | |||
| 3 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060720 | |||
| 4 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | geänderte Positionen | 20060720 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060720 |
Method CALL_CUSTOMER_CHECK_TOTAL on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class CL_FRML_CHECK_ADAPT_ITEM has no parameter.
Method CLASS_CONSTRUCTOR on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method FIELDS_COMPTGT_DEP Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 |
Method FIELDS_COMPTGT_DEP on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method FIELDS_LIMIT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20061017 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20061017 | |||
| 3 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20061017 | |||
| 4 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20061017 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20061017 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20061017 |
Method FIELDS_MAT_SUB Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060901 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELDS_ROLE_MAT_SUB Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | I_FLG_CHECK_EMPTY_ROLE | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfen auch wenn Feld ROLE leer | 20060901 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELDS_TS_DEP Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 |
Method FIELDS_TS_DEP on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method FIELD_COMPTGT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_EXCVAL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 3 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_FLG_OUT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20061017 | |||
| 2 | IS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20061017 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20061017 | |||
| 4 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20061017 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20061017 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20061017 |
Method FIELD_MATNR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060918 | |||
| 4 | I_KEYDATE | Call by reference | Type reference (TYPE) | RCPE_ADATUM | Stichtag | 20060918 | |||
| 5 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 6 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060901 | |||
| 7 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_OVR_FACTOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_POSNR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060915 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060915 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060915 | |||
| 4 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060915 | |||
| 5 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060915 | |||
| 6 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060915 | |||
| 7 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060915 | |||
| 8 | XT_POSNR_NOT_ALLOWED | Call by reference | Type reference (TYPE) | FRMLTY_POSNR_ITEM | Nicht erlaubte Positionsnummern | 20060915 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060915 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060915 |
Method FIELD_PO_FLG Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060922 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060922 | |||
| 3 | IT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060922 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20061017 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060922 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060922 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060922 |
Method FIELD_ROLE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | IT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060915 | |||
| 4 | I_FLG_CHECK_EMPTY_ROLE | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfen auch wenn Feld ROLE leer | 20060901 | |||
| 5 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 6 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_SUBID Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060901 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 5 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060901 | |||
| 6 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_TS_PERCENT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_TS_QTY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 3 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_TS_UNIT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20061017 | |||
| 2 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20061017 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_UNIT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060918 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060901 | |||
| 4 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060918 | |||
| 5 | I_KEYDATE | Call by reference | Type reference (TYPE) | RCPE_ADATUM | Stichtag | 20060901 | |||
| 6 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060901 | |||
| 7 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060918 | |||
| 8 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method FIELD_UNIT_MAT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060918 | |||
| 2 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor Änderung | 20060918 | |||
| 3 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060918 | |||
| 4 | I_KEYDATE | Call by reference | Type reference (TYPE) | RCPE_ADATUM | Stichtag | 20060918 | |||
| 5 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060918 | |||
| 6 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060918 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060918 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060918 |
Method GET_ALLOWED_UNITS_INCL_MAT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_ALLOWED_UNITS | Call by reference | Type reference (TYPE) | FRMLTY_ALLOWED_UNITS | Erlaubte Einheiten, unter Berücksichtigung des Materials | 20060918 | |||
| 2 | IT_ALLOWED_UNITS_CUST | Call by reference | Type reference (TYPE) | FRMLTY_ALLOWED_UNITS | Erlaubte Mengeneinheiten aus Customizing | 20060918 | |||
| 3 | I_MATNR | Call by reference | Type reference (TYPE) | MATNR | Material der zu prüfenden Position | 20060918 |
Method GET_ALLOWED_UNITS_INCL_MAT on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method GET_EDIT_ALT_FIELDS Signature
Method GET_EDIT_ALT_FIELDS on class CL_FRML_CHECK_ADAPT_ITEM has no parameter.
Method GET_EDIT_ALT_FIELDS on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method GROUP_ITEMS_ADAPT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IS_ITEM_PARENT | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Vater Position | 20060919 | |||
| 2 | XS_ITEM_CHILD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Gruppen Position (Kind) | 20060919 |
Method GROUP_ITEMS_ADAPT on class CL_FRML_CHECK_ADAPT_ITEM has no exception.
Method ITEMS_CHECK_FLAGS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Kopfänderungen fehlerhaft | 20061108 | |||
| 2 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20061108 | |||
| 3 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen | 20061108 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20061218 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20061218 |
Method ITEMS_UPDATE_AFTER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060920 | |||
| 2 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060920 | |||
| 3 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen | 20060920 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060920 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060920 |
Method ITEMS_UPDATE_BEFORE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060920 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060920 | |||
| 3 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060920 | |||
| 4 | IT_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Positionen vor der Änderung | 20060920 | |||
| 5 | I_GUID_ROOT | Call by reference | Type reference (TYPE) | PVS_GUID | Rezept/Baustein GUID (Wurzel Objekt bei abh. Formeln) | 20060925 | |||
| 6 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060920 | |||
| 7 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen | 20060920 | |||
| 8 | XT_POSNR_NOT_ALLOWED | Call by reference | Type reference (TYPE) | FRMLTY_POSNR_ITEM | Nicht erlaubte Positionsnummern | 20060920 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060920 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060920 |
Method ITEM_DEFAULTS_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060901 | |||
| 3 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor der Änderung | 20060901 | |||
| 4 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060901 | |||
| 5 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Geänderte Position | 20060901 | |||
| 6 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method ITEM_DELETE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060915 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060925 | |||
| 3 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060925 | |||
| 4 | I_GUID_ROOT | Call by reference | Type reference (TYPE) | PVS_GUID | Rezept/Baustein GUID (Wurzel Objekt bei abh. Formeln) | 20060925 | |||
| 5 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060915 | |||
| 6 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060915 | |||
| 7 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060915 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060925 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060915 |
Method ITEM_INSERT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060915 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060915 | |||
| 3 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060915 | |||
| 4 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060915 | |||
| 5 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20061030 | |||
| 6 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060915 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060915 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060915 |
Method ITEM_UPDATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060901 | |||
| 2 | IS_ADDINF | Call by reference | Type reference (TYPE) | FRMLS_ADDINF | Stichtag, AENNR, Gültig von, Gültig bis | 20060901 | |||
| 3 | IS_HDR | Call by reference | Type reference (TYPE) | FRMLS_HDR_ALL | Formel Kopfdaten | 20060901 | |||
| 4 | IS_ITEM_OLD | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position vor der Änderung | 20060901 | |||
| 5 | IS_KEYPATH | Call by reference | Type reference (TYPE) | FRMLS_KEYPATH | Schlüsseldaten zur Formel | 20060901 | |||
| 6 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Geänderte Position | 20060901 | |||
| 7 | XT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060901 | |||
| 8 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen | 20060901 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060901 |
Method KEYFIELDS_UNIQUE_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060920 | |||
| 2 | IS_IGNORE_LINES | Call by reference | Type reference (TYPE) | FRMLS_IGNORE_LINES | Kennzeichen zum Ignorieren best. Positionen | 20060920 | |||
| 3 | IT_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLTY_IOT_SCR | Geänderte Positionen | 20060920 | |||
| 4 | IT_KEYFIELD | Call by reference | Type reference (TYPE) | RMSTT_FNAME | Schlüsselfelder für die Prüfung | 20060920 | |||
| 5 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060920 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060920 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060920 |
Method LOM2LORS_LORS2LOM_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_BOTH_NEEDED | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Material und Stoff müssen gepflegt sein | 20061016 | |||
| 2 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20061016 | |||
| 3 | IS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | Position | 20060901 | |||
| 4 | I_FIELD_FOR_LOG | Call by reference | Type reference (TYPE) | FIELDNAME | Feldname für Log Meldung | 20060901 | |||
| 5 | I_FLG_LOM2LORS | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = LOM2LORS, ' ' = LORS2LOM | 20060901 | |||
| 6 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20061016 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060901 |
Method POSNR_GET_NOT_ALLOWED Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen | 20060720 | |||
| 2 | ET_POSNR_NOT_ALLOWED | Call by reference | Type reference (TYPE) | FRMLTY_POSNR_ITEM | Positionsnummern nachfolgender Änderungsstände | 20060720 | |||
| 3 | I_AENNR | Call by reference | Type reference (TYPE) | AENNR | Änderungsnummer | 20060720 | |||
| 4 | I_GUID | Call by reference | Type reference (TYPE) | FRMLE_RECN | Formel GUID | 20060720 | |||
| 5 | I_KEYDATE | Call by reference | Type reference (TYPE) | FRM31_DATE_TYPE | Stichtag | 20060720 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060720 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060720 |
Method REQFIELDS_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_ERROR | Call by reference | Type reference (TYPE) | FLAG | Kennz.: 'X' = Prüfung liefert Fehler | 20060921 | |||
| 2 | XS_ITEM_NEW | Call by reference | Type reference (TYPE) | FRMLS_IOT_SCR | geänderte Position | 20060921 | |||
| 3 | XT_LOG | Call by reference | Type reference (TYPE) | FRMLTY_LOG_REC | Meldungen aufgrund der Prüfung | 20060921 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060921 | ||
| 2 | Erforderliche Parameter nicht gefüllt | 20060921 |
Method UNIT_CUSTOMIZING_GET Signature
Method UNIT_CUSTOMIZING_GET on class CL_FRML_CHECK_ADAPT_ITEM has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Es ist ein gravierender Fehler aufgetreten | 20060918 |
History
| Last changed by/on | SAP | 20110908 |
| SAP Release Created in | 700 |