SAP ABAP Class CL_FRML_CHECK_ADAPT_ITEM (Checks/Adjustments for Formula Input/Output Items)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   PLM-RM (Application Component) Recipe Management
     RMSFRMSPC (Package) RMS-FRM: RMS Formula - Specification Database
Properties
Class CL_FRML_CHECK_ADAPT_ITEM  
Short Description Checks/Adjustments for Formula Input/Output Items    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class RMINT    
Program status     
Category 0   
Package RMSFRMSPC   RMS-FRM: RMS Formula - Specification Database 
Created 20060720   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 FRM11 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
3 FRM20 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
4 FRM31 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
5 RCP31 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_FRML_CHECK_ADAPT_ITEM has no interface implemented.
Friends
Class CL_FRML_CHECK_ADAPT_ITEM has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 CON_EHS_ERRCLASS_C Constant Private Type reference (TYPE) ARBGB 'C§' Message Class EH&S 20061016
2 CON_EHS_ERRCLASS_D Constant Private Type reference (TYPE) ARBGB 'D9' Message Class EH&S 20061016
3 CON_FALSE Constant Public Type reference (TYPE) FLAG ' ' False 20060720
4 CON_FIELD_COMPLOW Constant Private Type reference (TYPE) FIELDNAME 'COMPLOW' Item Field Name 20060720
5 CON_FIELD_COMPTGT Constant Private Type reference (TYPE) FIELDNAME 'COMPTGT' Item Field Name 20060720
6 CON_FIELD_COMPUPP Constant Private Type reference (TYPE) FIELDNAME 'COMPUPP' Item Field Name 20060720
7 CON_FIELD_EXCVAL Constant Private Type reference (TYPE) FIELDNAME 'EXCVAL' Item Field Name 20060720
8 CON_FIELD_FLG_OUT Constant Private Type reference (TYPE) FIELDNAME 'FLG_OUT' Item Field Name 20060921
9 CON_FIELD_MATNR Constant Private Type reference (TYPE) FIELDNAME 'MATNR' Item Field Name 20060720
10 CON_FIELD_OPLOW Constant Private Type reference (TYPE) FIELDNAME 'OPLOW' Item Field Name 20060720
11 CON_FIELD_OPUP Constant Private Type reference (TYPE) FIELDNAME 'OPUP' Item Field Name 20060720
12 CON_FIELD_OVR_FACTOR Constant Private Type reference (TYPE) FIELDNAME 'OVR_FACTOR' Item Field Name 20060720
13 CON_FIELD_POSNR Constant Private Type reference (TYPE) FIELDNAME 'POSNR' Item Field Name 20060720
14 CON_FIELD_PO_FLG Constant Private Type reference (TYPE) FIELDNAME 'PO_FLG' Item Field Name 20060921
15 CON_FIELD_ROLE Constant Private Type reference (TYPE) FIELDNAME 'ROLE' Item Field Name 20060720
16 CON_FIELD_STD_ALT_FLG Constant Private Type reference (TYPE) FIELDNAME 'STD_ALT_FLG' Item Field Name 20061108
17 CON_FIELD_STREAM_ID Constant Private Type reference (TYPE) FIELDNAME 'STREAM_ID' Item Field Name 20060921
18 CON_FIELD_SUBID Constant Private Type reference (TYPE) FIELDNAME 'SUBID' Item Field Name 20060720
19 CON_FIELD_SUBRECN Constant Private Type reference (TYPE) FIELDNAME 'SUBRECN' Item Field Name 20060823
20 CON_FIELD_TS_PERCENT Constant Private Type reference (TYPE) FIELDNAME 'TS_PERCENT' Item Field Name 20060720
21 CON_FIELD_TS_QTY Constant Private Type reference (TYPE) FIELDNAME 'TS_QTY' Item Field Name 20060720
22 CON_FIELD_TS_UNIT Constant Private Type reference (TYPE) FIELDNAME 'TS_UNIT' Item Field Name 20060720
23 CON_FIELD_UNIT Constant Private Type reference (TYPE) FIELDNAME 'UNIT' Item Field Name 20060720
24 CON_OP_GE Constant Private Type reference (TYPE) ESEPRECL '>=' Operator: Greater Than or Equal to 20061031
25 CON_OP_GT Constant Private Type reference (TYPE) ESEPRECL '>' Operator: Greater Than 20061031
26 CON_OP_LE Constant Private Type reference (TYPE) ESEPRECU '<=' Operator: Less Than or Equal to 20061031
27 CON_OP_LT Constant Private Type reference (TYPE) ESEPRECU '<' Operator: Less Than 20061031
28 CON_TRUE Constant Public Type reference (TYPE) FLAG 'X' True 20060720
29 MT_ALLOWED_UNITS Static Attribute Private Type reference (TYPE) FRMLTY_ALLOWED_UNITS Table of Permitted Units of Measure 20060720
30 MT_ALT_FIELDS Static Attribute Private Type reference (TYPE) LVC_T_STYL All Fields of Alternatives from Customizing 20060919
31 MT_KEY_FIELDS Static Attribute Private Type reference (TYPE) RMSTT_FNAME Key Fields for Key Field Check 20060921
32 M_CHECK_FUNCTION_AFTER Static Attribute Private Type reference (TYPE) FRMLE_FUNCNAME Function Module: Item Check After 20060720
33 M_CHECK_FUNCTION_PRE Static Attribute Private Type reference (TYPE) FRMLE_FUNCNAME Function Module: Item Check Before 20060720
34 M_CHECK_FUNCTION_TOTAL Static Attribute Private Type reference (TYPE) FRMLE_FUNCNAME Function Module: Item Check All 20060720
35 M_CHECK_MATERIAL_UNIT Static Attribute Private Type reference (TYPE) FLAG Indicator: 'X' = Include Material Units 20060918
36 M_COUNT_ERROR Static Attribute Private Type reference (TYPE) I Error messages counter 20060720
37 M_DEFAULT_UNIT Static Attribute Private Type reference (TYPE) MSEHI Default Unit 20060720
38 M_DEF_UNIT_DIM Static Attribute Private Type reference (TYPE) DIMID Default Dimension 20060720
39 M_EVENT_LOM2LORS Static Attribute Private Type reference (TYPE) FRMLE_ROLE_EVENT Event LOM -> LORS 20060831
40 M_EVENT_LORS2LOM Static Attribute Private Type reference (TYPE) FRMLE_ROLE_EVENT Event LORS -> LOM 20060831
41 M_MSG_DUMMY Static Attribute Private Type reference (TYPE) SYCHAR255 Dummy Variable for Internal Message Output 20060720
Methods
# Method Level Visibility Method type Description Created on
1 ALTERNATIVES_ADAPT Static method Public Method Transfer Fields from Leading Item to Alternatives 20060901
2 CALL_CUSTOMER_CHECK Static method Private Method Call Customer Check Function 20060720
3 CALL_CUSTOMER_CHECK_AFTER Static method Public Method Call Customer Check Function: After Standard Check 20060720
4 CALL_CUSTOMER_CHECK_PRE Static method Public Method Call Customer Check Function: Before Standard Check 20060720
5 CALL_CUSTOMER_CHECK_TOTAL Static method Public Method Call Customer Check Function: For All Items 20060720
6 CLASS_CONSTRUCTOR Static method Public Constructor CLASS_CONSTRUCTOR 20060720
7 FIELDS_COMPTGT_DEP Static method Private Method Adjust Fields Dependent on COMPTGT / UNIT 20060901
8 FIELDS_LIMIT Static method Public Method Field Check: Quantity + Limit Values and Operators 20061017
9 FIELDS_MAT_SUB Static method Public Method Field Check: Material + Substance 20060901
10 FIELDS_ROLE_MAT_SUB Static method Public Method Field Check: Component Type + Material + Substance 20060901
11 FIELDS_TS_DEP Static method Private Method Adjust Fields Dependent on TS_QTY / TS_UNIT 20060901
12 FIELD_COMPTGT Static method Public Method Field Check: Item Quantity 20060901
13 FIELD_EXCVAL Static method Public Method Field Check: Exception Value 20060901
14 FIELD_FLG_OUT Static method Public Method Field Check: Output Indicator 20061017
15 FIELD_MATNR Static method Public Method Field Check: Material Number 20060901
16 FIELD_OVR_FACTOR Static method Public Method Field Check: Overrun Factor (Aeration) 20060901
17 FIELD_POSNR Static method Public Method Field Check: Item Number 20060901
18 FIELD_PO_FLG Static method Public Method Field Check: Primary Output Indicator 20060922
19 FIELD_ROLE Static method Public Method Field Check: Component Type 20060901
20 FIELD_SUBID Static method Public Method Field Check: Substance 20060901
21 FIELD_TS_PERCENT Static method Public Method Field Check: Proportion of Total Solids 20060901
22 FIELD_TS_QTY Static method Public Method Field Check: Total Solids 20060901
23 FIELD_TS_UNIT Static method Public Method Field Check: Unit of Measure of Total Solids 20060901
24 FIELD_UNIT Static method Public Method Field Check: Unit of Measure of Item 20060901
25 FIELD_UNIT_MAT Static method Private Method Field Check: Unit of Measure with Material 20060918
26 GET_ALLOWED_UNITS_INCL_MAT Static method Private Method Permitted Units Including Material Units 20060918
27 GET_EDIT_ALT_FIELDS Static method Private Method Determines Changeable Fields of Alternatives 20060918
28 GROUP_ITEMS_ADAPT Static method Public Method Transfer Fields from Leading Item to Group Item 20060901
29 ITEMS_CHECK_FLAGS Static method Public Method Check Different Flags for Each Item 20061108
30 ITEMS_UPDATE_AFTER Static method Public Method Final Adjustments to All Items 20060920
31 ITEMS_UPDATE_BEFORE Static method Public Method Previous Adjustments to All Items 20060920
32 ITEM_DEFAULTS_SET Static method Public Method Set Default Values for Empty Item Fields 20060901
33 ITEM_DELETE Static method Public Method Checks for Item to Be Deleted 20060901
34 ITEM_INSERT Static method Public Method Checks for New Item 20060901
35 ITEM_UPDATE Static method Public Method Field Checks for Changed, Single Item 20060901
36 KEYFIELDS_UNIQUE_CHECK Static method Public Method Check Key Fields for Uniqueness 20060915
37 LOM2LORS_LORS2LOM_CHECK Static method Private Method Check Whether Subst. Required for Mat. or Mat. for Subst. 20060901
38 POSNR_GET_NOT_ALLOWED Static method Public Method Determines Non-Permitted Item Numbers of All Change States 20060720
39 REQFIELDS_CHECK Static method Public Method Required Entry Field Check 20060915
40 UNIT_CUSTOMIZING_GET Static method Private Method Determine Default Values for Units 20060918
Events
Class CL_FRML_CHECK_ADAPT_ITEM has no event.
Types
Class CL_FRML_CHECK_ADAPT_ITEM has no local type.
Method Signatures

Method ALTERNATIVES_ADAPT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_ITEM_PARENT Call by reference Type reference (TYPE) FRMLS_IOT_SCR Führende Position (Vater) 20060919
2 Changing XS_ITEM_CHILD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Alternativ Position (Kind) 20060919

Method ALTERNATIVES_ADAPT on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method CALL_CUSTOMER_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060720
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060720
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060720
4 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060720
5 Importing I_CHECK_FUNCTION Call by reference Type reference (TYPE) FRMLE_FUNCNAME Name Prüffunktion 20060720
6 Importing I_FIELDNAME Call by reference Type reference (TYPE) LVC_FNAME Name Feld, das geändert wurde 20060720
7 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060720
8 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060720

Method CALL_CUSTOMER_CHECK on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method CALL_CUSTOMER_CHECK_AFTER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060720
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060720
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060720
4 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060720
5 Importing I_FIELDNAME Call by reference Type reference (TYPE) LVC_FNAME Name Feld, das geändert wurde 20060720
6 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060720
7 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060720

Method CALL_CUSTOMER_CHECK_AFTER on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method CALL_CUSTOMER_CHECK_PRE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060720
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060720
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060720
4 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060720
5 Importing I_FIELDNAME Call by reference Type reference (TYPE) LVC_FNAME Name Feld, das geändert wurde 20060720
6 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060720
7 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060720

Method CALL_CUSTOMER_CHECK_PRE on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method CALL_CUSTOMER_CHECK_TOTAL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060720
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060720
3 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060720
4 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR geänderte Positionen 20060720
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060720

Method CALL_CUSTOMER_CHECK_TOTAL on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method CLASS_CONSTRUCTOR Signature

Method CLASS_CONSTRUCTOR on class CL_FRML_CHECK_ADAPT_ITEM has no parameter.
Method CLASS_CONSTRUCTOR on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method FIELDS_COMPTGT_DEP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901

Method FIELDS_COMPTGT_DEP on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method FIELDS_LIMIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20061017
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20061017
3 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20061017
4 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20061017
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20061017
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20061017

Method FIELDS_MAT_SUB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060901
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELDS_ROLE_MAT_SUB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Importing I_FLG_CHECK_EMPTY_ROLE Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfen auch wenn Feld ROLE leer 20060901
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELDS_TS_DEP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901

Method FIELDS_TS_DEP on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method FIELD_COMPTGT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_EXCVAL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
3 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_FLG_OUT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20061017
2 Importing IS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20061017
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20061017
4 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20061017
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20061017
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20061017

Method FIELD_MATNR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060918
4 Importing I_KEYDATE Call by reference Type reference (TYPE) RCPE_ADATUM Stichtag 20060918
5 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
6 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060901
7 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_OVR_FACTOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
# Exception Resumable Description Created on
1 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_POSNR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060915
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060915
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060915
4 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060915
5 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060915
6 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060915
7 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060915
8 Changing XT_POSNR_NOT_ALLOWED Call by reference Type reference (TYPE) FRMLTY_POSNR_ITEM Nicht erlaubte Positionsnummern 20060915
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060915
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060915

Method FIELD_PO_FLG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060922
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060922
3 Importing IT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060922
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20061017
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060922
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060922
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060922

Method FIELD_ROLE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Importing IT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060915
4 Importing I_FLG_CHECK_EMPTY_ROLE Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfen auch wenn Feld ROLE leer 20060901
5 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
6 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_SUBID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060901
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
5 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060901
6 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_TS_PERCENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
# Exception Resumable Description Created on
1 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_TS_QTY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
3 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
# Exception Resumable Description Created on
1 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_TS_UNIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20061017
2 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20061017
# Exception Resumable Description Created on
1 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_UNIT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060918
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060901
4 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060918
5 Importing I_KEYDATE Call by reference Type reference (TYPE) RCPE_ADATUM Stichtag 20060901
6 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060901
7 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060918
8 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method FIELD_UNIT_MAT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060918
2 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor Änderung 20060918
3 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060918
4 Importing I_KEYDATE Call by reference Type reference (TYPE) RCPE_ADATUM Stichtag 20060918
5 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060918
6 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060918
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060918
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060918

Method GET_ALLOWED_UNITS_INCL_MAT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_ALLOWED_UNITS Call by reference Type reference (TYPE) FRMLTY_ALLOWED_UNITS Erlaubte Einheiten, unter Berücksichtigung des Materials 20060918
2 Importing IT_ALLOWED_UNITS_CUST Call by reference Type reference (TYPE) FRMLTY_ALLOWED_UNITS Erlaubte Mengeneinheiten aus Customizing 20060918
3 Importing I_MATNR Call by reference Type reference (TYPE) MATNR Material der zu prüfenden Position 20060918

Method GET_ALLOWED_UNITS_INCL_MAT on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method GET_EDIT_ALT_FIELDS Signature

Method GET_EDIT_ALT_FIELDS on class CL_FRML_CHECK_ADAPT_ITEM has no parameter.
Method GET_EDIT_ALT_FIELDS on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method GROUP_ITEMS_ADAPT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IS_ITEM_PARENT Call by reference Type reference (TYPE) FRMLS_IOT_SCR Vater Position 20060919
2 Changing XS_ITEM_CHILD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Gruppen Position (Kind) 20060919

Method GROUP_ITEMS_ADAPT on class CL_FRML_CHECK_ADAPT_ITEM has no exception.

Method ITEMS_CHECK_FLAGS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Kopfänderungen fehlerhaft 20061108
2 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20061108
3 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen 20061108
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20061218
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20061218

Method ITEMS_UPDATE_AFTER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060920
2 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060920
3 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen 20060920
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060920
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060920

Method ITEMS_UPDATE_BEFORE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060920
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060920
3 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060920
4 Importing IT_ITEM_OLD Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Positionen vor der Änderung 20060920
5 Importing I_GUID_ROOT Call by reference Type reference (TYPE) PVS_GUID Rezept/Baustein GUID (Wurzel Objekt bei abh. Formeln) 20060925
6 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060920
7 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen 20060920
8 Changing XT_POSNR_NOT_ALLOWED Call by reference Type reference (TYPE) FRMLTY_POSNR_ITEM Nicht erlaubte Positionsnummern 20060920
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060920
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060920

Method ITEM_DEFAULTS_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060901
3 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor der Änderung 20060901
4 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060901
5 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR Geänderte Position 20060901
6 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method ITEM_DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060915
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060925
3 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060925
4 Importing I_GUID_ROOT Call by reference Type reference (TYPE) PVS_GUID Rezept/Baustein GUID (Wurzel Objekt bei abh. Formeln) 20060925
5 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060915
6 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060915
7 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060915
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060925
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060915

Method ITEM_INSERT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060915
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060915
3 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060915
4 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060915
5 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20061030
6 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060915
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060915
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060915

Method ITEM_UPDATE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060901
2 Importing IS_ADDINF Call by reference Type reference (TYPE) FRMLS_ADDINF Stichtag, AENNR, Gültig von, Gültig bis 20060901
3 Importing IS_HDR Call by reference Type reference (TYPE) FRMLS_HDR_ALL Formel Kopfdaten 20060901
4 Importing IS_ITEM_OLD Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position vor der Änderung 20060901
5 Importing IS_KEYPATH Call by reference Type reference (TYPE) FRMLS_KEYPATH Schlüsseldaten zur Formel 20060901
6 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR Geänderte Position 20060901
7 Changing XT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060901
8 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen 20060901
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060901

Method KEYFIELDS_UNIQUE_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060920
2 Importing IS_IGNORE_LINES Call by reference Type reference (TYPE) FRMLS_IGNORE_LINES Kennzeichen zum Ignorieren best. Positionen 20060920
3 Importing IT_ITEM_NEW Call by reference Type reference (TYPE) FRMLTY_IOT_SCR Geänderte Positionen 20060920
4 Importing IT_KEYFIELD Call by reference Type reference (TYPE) RMSTT_FNAME Schlüsselfelder für die Prüfung 20060920
5 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060920
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060920
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060920

Method LOM2LORS_LORS2LOM_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_BOTH_NEEDED Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Material und Stoff müssen gepflegt sein 20061016
2 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20061016
3 Importing IS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR Position 20060901
4 Importing I_FIELD_FOR_LOG Call by reference Type reference (TYPE) FIELDNAME Feldname für Log Meldung 20060901
5 Importing I_FLG_LOM2LORS Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = LOM2LORS, ' ' = LORS2LOM 20060901
6 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20061016
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060901

Method POSNR_GET_NOT_ALLOWED Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen 20060720
2 Exporting ET_POSNR_NOT_ALLOWED Call by reference Type reference (TYPE) FRMLTY_POSNR_ITEM Positionsnummern nachfolgender Änderungsstände 20060720
3 Importing I_AENNR Call by reference Type reference (TYPE) AENNR Änderungsnummer 20060720
4 Importing I_GUID Call by reference Type reference (TYPE) FRMLE_RECN Formel GUID 20060720
5 Importing I_KEYDATE Call by reference Type reference (TYPE) FRM31_DATE_TYPE Stichtag 20060720
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060720
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060720

Method REQFIELDS_CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_FLG_ERROR Call by reference Type reference (TYPE) FLAG Kennz.: 'X' = Prüfung liefert Fehler 20060921
2 Changing XS_ITEM_NEW Call by reference Type reference (TYPE) FRMLS_IOT_SCR geänderte Position 20060921
3 Changing XT_LOG Call by reference Type reference (TYPE) FRMLTY_LOG_REC Meldungen aufgrund der Prüfung 20060921
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060921
2 MISSING_PARAMETER Erforderliche Parameter nicht gefüllt 20060921

Method UNIT_CUSTOMIZING_GET Signature

Method UNIT_CUSTOMIZING_GET on class CL_FRML_CHECK_ADAPT_ITEM has no parameter.
# Exception Resumable Description Created on
1 ERROR Es ist ein gravierender Fehler aufgetreten 20060918
History
Last changed by/on SAP  20110908 
SAP Release Created in 700