SAP ABAP Table ISU_DM_MR_CARD_S_DEVICE (Device)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷
IS-U-DM-MR (Application Component) Meter Reading
⤷
EE16 (Package) IS-U: Meter Reading Order Creation
⤷
⤷
Basic Data
| Table Category | INTTAB | Structure |
| Structure | ISU_DM_MR_CARD_S_DEVICE |
|
| Short Description | Device |
Delivery and Maintenance
| Pool/cluster | ||
| Delivery Class | ||
| Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
| |
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|---|---|---|---|---|---|---|---|---|---|
| 1 | |
V_EGER | STRU | 0 | 0 | ||||
| 2 | |
MANDT | MANDT | CLNT | 3 | 0 | Client | ||
| 3 | |
EQUNR | EQUNR | CHAR | 18 | 0 | Equipment Number | ||
| 4 | |
BISZEITSCH | DATUM | DATS | 8 | 0 | Date at Which a Time Slice Expires | ||
| 5 | |
ABZEITSCH | DATUM | DATS | 8 | 0 | Date from which time slice is valid | ||
| 6 | |
LOGIKNR | LOGIKNR | NUMC | 18 | 0 | Logical device number | ||
| 7 | |
GERNR | GERNR | CHAR | 18 | 0 | Serial Number | ||
| 8 | |
MATNR | MATNR | CHAR | 18 | 0 | Material Number | ||
| 9 | |
WERKS_D | WERKS | CHAR | 4 | 0 | Plant | ||
| 10 | |
LGORT_D | LGORT | CHAR | 4 | 0 | Storage location | ||
| 11 | |
E_ZWGRUPPE | GEGST | CHAR | 8 | 0 | Register Group | ||
| 12 | |
EINBDAT | DATUM | DATS | 8 | 0 | Installation date | ||
| 13 | |
AUSBDAT | DATUM | DATS | 8 | 0 | Device removal date | ||
| 14 | |
GERWECHS | GERWECHS | CHAR | 2 | 0 | Activity reason | ||
| 15 | |
DEVLOC | TPLNR | CHAR | 30 | 0 | Device Location | ||
| 16 | |
WGRUPPE | GEGST | CHAR | 8 | 0 | Winding group | ||
| 17 | |
PRIMWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active primary winding | ||
| 18 | |
SEKWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active secondary winding | ||
| 19 | |
PRIMWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active primary winding | ||
| 20 | |
SEKWNR | LFDNR2 | NUMC | 2 | 0 | Winding number of active secondary winding | ||
| 21 | |
EAGRUPPE | GEGST | CHAR | 8 | 0 | Input/output group | ||
| 22 | |
KOMGRP | GEGST | CHAR | 8 | 0 | ARCR Command Group | ||
| 23 | |
LOS | GEGST | CHAR | 8 | 0 | Sample lot | ||
| 24 | |
MESSDRCK | MESSDRCK | DEC | 7 | 4 | Measured Pressure (Outlet Pressure) in Bars | ||
| 25 | |
UEBERVER | UEBERV | DEC | 10 | 3 | Transformation ratio | ||
| 26 | |
BESITZ | BESITZ | NUMC | 2 | 0 | Inspection relevance of device | ||
| 27 | |
BGLJAHR | JAHR | NUMC | 4 | 0 | Certification Year | ||
| 28 | |
WECHSEL | JAHR | NUMC | 4 | 0 | Advance replacement year | ||
| 29 | |
BGLSTAT | BGLSTAT | CHAR | 1 | 0 | Certification status | ||
| 30 | |
KZSTICH | KZSTICH | CHAR | 1 | 0 | Status of sample device | ||
| 31 | |
SCHWGRAD | DEC2_1 | DEC | 3 | 1 | Difficulty level: Factor for meter reader payment | ||
| 32 | |
PLOMBDAT | DATUM | DATS | 8 | 0 | Date of last lead sealing | ||
| 33 | |
HERST | TEXT30 | CHAR | 30 | 0 | Manufacturer of asset | ||
| 34 | |
BGLART | BGLART | CHAR | 2 | 0 | Type of certification | ||
| 35 | |
BGLNUM | CHAR15 | CHAR | 15 | 0 | Certification number | ||
| 36 | |
UMBAUDAT | DATUM | DATS | 8 | 0 | Modification date | ||
| 37 | |
UMBAUGR | UMBAUGR | CHAR | 2 | 0 | Modification reason | ||
| 38 | |
EICHFAEL | KENNZX | CHAR | 1 | 0 | Use calibration validity | ||
| 39 | |
PARAMETR | PARAMETR | CHAR | 8 | 0 | Parametrization | ||
| 40 | |
PLOMBE | PLOMBE | CHAR | 2 | 0 | Seal code | ||
| 41 | |
ERDAT | DATUM | DATS | 8 | 0 | Date on which the record was created | ||
| 42 | |
ERNAM | USNAM | CHAR | 12 | 0 | Name of Person who Created the Object | ||
| 43 | |
AEDAT | DATUM | DATS | 8 | 0 | Last Changed On | ||
| 44 | |
AENAM | USNAM | CHAR | 12 | 0 | Name of Person Who Changed Object | ||
| 45 | |
E_ZSPANNS | SPANNUNG | DEC | 4 | 1 | Register factor: secondary transformer voltage | ||
| 46 | |
E_ZSPANNP | WSPANNP | DEC | 6 | 0 | Register factor: primary transformer voltage | ||
| 47 | |
E_ZSTROMS | E_ZSTROMS | DEC | 5 | 2 | Register factor: secondary transformer current | ||
| 48 | |
E_ZSTROMP | E_ZSTROMP | DEC | 5 | 1 | Register factor: primary transformer current | ||
| 49 | |
BAUJJ | CJAHR | CHAR | 4 | 0 | Year of construction | ||
| 50 | |
DEVGRP | DEVGRP | CHAR | 8 | 0 | Device group | ||
| 51 | |
SPARTE | SPART | CHAR | 2 | 0 | Division | ||
| 52 | |
TYPBZ | TYPBZ | CHAR | 20 | 0 | Manufacturer model number | ||
| 53 | |
APPROVALNR | CHAR15 | CHAR | 15 | 0 | Device inspection number | ||
| 54 | |
VLZEIT_DEV | ALLGVLZEIT | DEC | 2 | 0 | Individual cal. validity (years) of dev. subject to certif. | ||
| 55 | |
KOMBINAT | KOMBINAT | CHAR | 8 | 0 | Combination of a device category | ||
| 56 | |
BGLNETZ | KENNZX | CHAR | 1 | 0 | Certify installed devices | ||
| 57 | |
ORDERCODE2 | CHAR004 | CHAR | 4 | 0 | Special Order Code for Dev./Dev. Category in Replacement | ||
| 58 | |
NOTIF_CODE | CHAR004 | CHAR | 4 | 0 | Notification code | ||
| 59 | |
KZEQBS | KZEQBS | CHAR | 1 | 0 | EQSI Exists | ||
| 60 | |
PPM_METER | PPM_METER | NUMC | 2 | 0 | Prepayment Meter | ||
| 61 | |
J_OBJNR | J_OBJNR | CHAR | 22 | 0 | Object number | ||
| 62 | |
EGPL | STRU | 0 | 0 | ||||
| 63 | |
0 | 0 | Device Location | |||||
| 64 | |
MANDT | MANDT | CLNT | 3 | 0 | Client | ||
| 65 | |
DEVLOC | TPLNR | CHAR | 30 | 0 | Device Location | ||
| 66 | |
SPRAS | SPRAS | LANG | 1 | 0 | Language Key | ||
| 67 | |
PLTXT | TEXT40 | CHAR | 40 | 0 | Description of functional location | ||
| 68 | |
KZLTX | XFELD | CHAR | 1 | 0 | Indicator: More long text exists | ||
| 69 | |
TPLKZ | TPLKZ | CHAR | 5 | 0 | Functional location structure indicators | ||
| 70 | |
FLTYP | FLTYP | CHAR | 1 | 0 | Functional Location Category | ||
| 71 | |
HAUS | TPLNR | CHAR | 30 | 0 | Connection Object | ||
| 72 | |
DATAB | DATUM | DATS | 8 | 0 | Valid-From Date | ||
| 73 | |
IAUTG | IAUTG | CHAR | 4 | 0 | Authorization Group for Technical Object | ||
| 74 | |
INH_BEGRUI | INHER | CHAR | 1 | 0 | Data origin for authorization group field | ||
| 75 | |
IWERK | WERKS | CHAR | 4 | 0 | Maintenance Planning Plant | ||
| 76 | |
INH_IWERKI | INHER | CHAR | 1 | 0 | Data origin for planning plant field | ||
| 77 | |
ILOM_POSNR | CHAR4 | CHAR | 4 | 0 | Position in superior technical object | ||
| 78 | |
ILOM_ISTYP | ILOM_ISTYP | CHAR | 1 | 0 | Object category for Industry Solutions (IS) | ||
| 79 | |
VSTELLE | VSTELLE | CHAR | 10 | 0 | Premise | ||
| 80 | |
SWERK | WERKS | CHAR | 4 | 0 | Maintenance Plant | ||
| 81 | |
INH_SWERKI | INHER | CHAR | 1 | 0 | Data origin for maintenance plant field | ||
| 82 | |
BUKRS | BUKRS | CHAR | 4 | 0 | Company Code | ||
| 83 | |
INH_BUKRSI | INHER | CHAR | 1 | 0 | Data origin for company code field | ||
| 84 | |
AD_ADDRNUM | AD_ADDRNUM | CHAR | 10 | 0 | Address number | ||
| 85 | |
INH_ADRNRI | INHER | CHAR | 1 | 0 | Data origin for address field | ||
| 86 | |
PMLOC | AP_STAND | CHAR | 10 | 0 | Location of maintenance object | ||
| 87 | |
INH_STORTI | INHER | CHAR | 1 | 0 | Data origin for location field | ||
| 88 | |
STORTZUS | TEXT30 | CHAR | 30 | 0 | Addition to device location | ||
| 89 | |
ILOAN | ILOAN | CHAR | 12 | 0 | Location and account assignment for technical object | ||
| 90 | |
J_OBJNR | J_OBJNR | CHAR | 22 | 0 | Object number | ||
| 91 | |
IEQUI | X | CHAR | 1 | 0 | Installation of equipment allowed at the functional location | ||
| 92 | |
INH_IEQUII | INHER | CHAR | 1 | 0 | Data origin for equip. inst. allowed field | ||
| 93 | |
ICRDT | DATUM | DATS | 8 | 0 | Date on Which Object Was Created | ||
| 94 | |
ICRNA | USNAM | CHAR | 12 | 0 | Name of User Who Created the Object | ||
| 95 | |
IUPDT | DATUM | DATS | 8 | 0 | Date on which the object was last changed | ||
| 96 | |
IUPNA | USNAM | CHAR | 12 | 0 | Name of the User Who Last Changed the Object | ||
| 97 | |
GP_STRNO | ILOM_STRNO | CHAR | 40 | 0 | Device Location Identification | ||
| 98 | |
0 | 0 | ||||||
| 99 | |
T499S | STRU | 0 | 0 | ||||
| 100 | |
MANDT | MANDT | CLNT | 3 | 0 | Client | ||
| 101 | |
WERKS_D | WERKS | CHAR | 4 | 0 | Plant | ||
| 102 | |
STORT_T499S | AP_STAND | CHAR | 10 | 0 | Location | ||
| 103 | |
TEXT40 | TEXT40 | CHAR | 40 | 0 | Text, 40 Characters Long | ||
| 104 | |
AD_ADDRNUM | AD_ADDRNUM | CHAR | 10 | 0 | Address number | ||
| 105 | |
ISU_DM_MR_CARD_T_REGISTER | TTYP | 0 | 0 |
History
| Last changed by/on | SAP | 20130529 |
| SAP Release Created in | 471 |