SAP ABAP Table ERCHV_INSTGR_DISP (Consumption Lines for Installation Groups)
Hierarchy
☛
IS-UT (Software Component) SAP Utilities/Telecommunication
⤷ IS-U-BI (Application Component) Contract Billing
⤷ EE20 (Package) IS-U: Billing
⤷ IS-U-BI (Application Component) Contract Billing
⤷ EE20 (Package) IS-U: Billing
Basic Data
Table Category | INTTAB | Structure |
Structure | ERCHV_INSTGR_DISP | Table Relationship Diagram |
Short Description | Consumption Lines for Installation Groups |
Delivery and Maintenance
Pool/cluster | ||
Delivery Class | ||
Data Browser/Table View Maintenance | Display/Maintenance Allowed with Restrictions |
Components
Field | Key | Data Element | Domain | Data Type |
Length | Decimal Places |
Short Description | Check table |
|
---|---|---|---|---|---|---|---|---|---|
1 | BELNR | E_BELNR | E_BELNR | CHAR | 12 | 0 | Number of a billing document | ||
2 | ANLAGE | ANLAGE | ANLAGE | CHAR | 10 | 0 | Installation | * | |
3 | INSTGRTYPE | INSTGRTYPE | INSTGRTYPE | CHAR | 4 | 0 | Grouping Type for Installation Group | * | |
4 | INSTROLE | INSTROLE | INSTROLE | CHAR | 4 | 0 | Role of an Installation Within the Installation Group | * | |
5 | MAININST | MAININST | ANLAGE | CHAR | 10 | 0 | Key of Primary Installation | * | |
6 | MAINDOCNO | MAINDOCNO | E_BELNR | CHAR | 12 | 0 | Billing Document Number of Primary Installation | ||
7 | LFDNR | LFDNR | LFDNR | CHAR | 3 | 0 | Sequence Number | ||
8 | AB | ABZEITSCH | DATUM | DATS | 8 | 0 | Date from which time slice is valid | ||
9 | BIS | BISZEITSCH | DATUM | DATS | 8 | 0 | Date at Which a Time Slice Expires | ||
10 | OPERAND | E_OPERAND | E_OPERAND | CHAR | 10 | 0 | Operand | * | |
11 | I_ABRMENGE | I_ABRMENGE | I_ABRMENGE | DEC | 31 | 14 | Billing quantity for internal billing format | ||
12 | MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) | ||
13 | NETTOBTR | NETTOBTR | WRTV7 | CURR | 13 | 2 | Net amount of billing line item | ||
14 | TWAERS | TWAERS | WAERS | CUKY | 5 | 0 | Transaction Currency | * | |
15 | SUBINST | SUBINST | ANLAGE | CHAR | 10 | 0 | Secondary Installation: Key | * | |
16 | SUBABRDATS | SUBABRDATS | DATUM | DATS | 8 | 0 | Scheduled Billing Date of Secondary Installation | ||
17 | SUBABRVORG | SUBABRVORG | ABRVORG | CHAR | 2 | 0 | Billing Transaction for Secondary Installation | ||
18 | TARGET_OP_MAIN1 | TARGET_OP_MAIN | E_OPERAND | CHAR | 10 | 0 | Target Operand for Data Ex. from Second. to Prim. Installatn | * | |
19 | TM1_MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) | ||
20 | TARGET_OP_MAIN2 | TARGET_OP_MAIN | E_OPERAND | CHAR | 10 | 0 | Target Operand for Data Ex. from Second. to Prim. Installatn | * | |
21 | TM2_MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) | ||
22 | TARGET_OP_MAIN3 | TARGET_OP_MAIN | E_OPERAND | CHAR | 10 | 0 | Target Operand for Data Ex. from Second. to Prim. Installatn | * | |
23 | TM3_MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) | ||
24 | TARGET_OP_SUB1 | TARGET_OP_SUB | E_OPERAND | CHAR | 10 | 0 | Target Operand for Data Ex. from Primary to Second. Inst. | * | |
25 | TS1_MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) | ||
26 | TARGET_OP_SUB2 | TARGET_OP_SUB | E_OPERAND | CHAR | 10 | 0 | Target Operand for Data Ex. from Primary to Second. Inst. | * | |
27 | TS2_MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) | ||
28 | TARGET_OP_SUB3 | TARGET_OP_SUB | E_OPERAND | CHAR | 10 | 0 | Target Operand for Data Ex. from Primary to Second. Inst. | * | |
29 | TS3_MSEH6 | MSEH6 | MSEH6 | CHAR | 6 | 0 | External Unit of Measurement in Technical Format (6-Char.) |
History
Last changed by/on | SAP | 20110901 |
SAP Release Created in | 472 |