Message Text
Device &1 reg. &2 period &3 - &4: no conversion factor due to gas date
Help Document

Diagnosis

No entry for the device, register and period you have specified was found that can be used to determine the conversion factor.

It is likely that the gas date and the normal meter reading date are too far apart. In this particular case, the month to which the program refers back (which is derived from the gas month of previous billing) is too far in front of the from-date of the earliest time slice of the current billing.

Important: If the weighted average of the conversion factor is calculated by means of degree day weighting, the gas month must not be more than one month before the meter reading date.

System Response

Procedure

  1. Check the gas date setting, in particular in scheduling. You can find the gas date in scheduling once the meter reading results have been entered.
  2. Billings and orders that have already been processed with an impermissible gas month may need to be reversed and processed again.
  3. If neither of the above are the case, the problem may be due to an internal error. If this is the case, contact SAP.

History
Last changed on/by 20110810  SAP 