SAP ABAP Message Class AH Message Number 811 (Device &1 reg. &2 period &3 - &4: standard volume cannot be determined)
Hierarchy
IS-UT (Software Component) SAP Utilities/Telecommunication
   IS-U-BI (Application Component) Contract Billing
     EE20 (Package) IS-U: Billing
Attribute
Message class AH  
Short Description IS-U billing (master data)    
Message Number 811  
Documentation status       Space: object requires documentation
Authorization check Error Message      
Changed On 20050224   
Message Text
Device &1 reg. &2 period &3 - &4: standard volume cannot be determined
Help Document

Diagnosis

A gas procedure is to be carried out for the register. For this procedure, the volume correction factor component is determined by a special procedure that uses the register relationship "volume correction factor calculation".

The specified register is linked to the operation code "Register contains standard volume" via the register relationship.

No or not enough meter reading results could be found for the specified register and period; these are needed to determine the standard volume.

System Response

Procedure

Check the meter reading results for the period in question. Enter the missing meter reading results, or correct existing unbillable meter meter results.

Billable meter reading results should be available for the specified dates.

If the meter reading results are correct, then an internal error may have occurred. In this case, contact SAP.

History
Last changed on/by 20110810  SAP 
SAP Release Created in