SAP ABAP Interface IF_SWF_IFS_PARAMETERS (OBSOLETE: Use IF_SWF_IFS_PARAMETER_CONTAINER)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-BMT-WFM (Application Component) SAP Business Workflow
⤷
SWF_IFS (Package) Workflow: Interfaces

⤷

⤷

Properties
Interface | IF_SWF_IFS_PARAMETERS | |
Short Description | OBSOLETE: Use IF_SWF_IFS_PARAMETER_CONTAINER |
General Data
Package | SWF_IFS | Workflow: Interfaces |
Created | 20000621 | SAP |
Last changed | 20110908 | SAP |
Unicode checks active |
Forward declarations
Interface IF_SWF_IFS_PARAMETERS has no forward declaration.
Interfaces
Interface IF_SWF_IFS_PARAMETERS has no interface.
Friends
Interface IF_SWF_IFS_PARAMETERS has no friend.
Attributes
Interface IF_SWF_IFS_PARAMETERS has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Sets the Parameter to a Type-Based Initial Value | 20000623 |
2 | ![]() |
Instance method | Public | Method | Delivers the Value to a Parameter | 20000623 |
3 | ![]() |
Instance method | Public | Method | Delivers the Data Reference to the Value of a Parameter | 20000623 |
4 | ![]() |
Instance method | Public | Method | Delivers a List with the Names of all Parameters | 20000621 |
5 | ![]() |
Instance method | Public | Method | Sets the Value of a Parameter | 20000623 |
6 | ![]() |
Instance method | Public | Method | Sets the Value of a Parameter Using a Data Reference | 20000623 |
Events
Interface IF_SWF_IFS_PARAMETERS has no event.
Types
Interface IF_SWF_IFS_PARAMETERS has no local type.
Method Signatures
Method CLEAR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
NAME | Value transfer | Type reference (TYPE) | SWFDNAME | Name der zu initialisierenden Komponente | 20000623 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Zugriff auf die Komponente nicht erlaubt | 20000623 | |
2 | ![]() |
Komponente existiert nicht | 20000623 |
Method GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
NAME | Value transfer | Type reference (TYPE) | SWFDNAME | Name der zu Komponente, deren Wert gelesen werden soll | 20000623 | ||
2 | ![]() |
UNIT | Call by reference | Type reference (TYPE) | ANY | Einheit der Komponente | 20000623 | ||
3 | ![]() |
VALUE | Call by reference | Type reference (TYPE) | ANY | Kopie des aktuellen Wertes der Komponente | 20000623 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Elementdefinition (z.B. interner Typname) ungültig | 20000623 | |
2 | ![]() |
Angegebener Name ist unbekannt | 20000623 | |
3 | ![]() |
Wert nicht typkompatibel zum Aktualparameter | 20000623 | |
4 | ![]() |
Einheit nicht typkompatibel zum Aktualparameter | 20000623 |
Method GET_REF Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
NAME | Value transfer | Type reference (TYPE) | SWFDNAME | Name der zu Komponente, deren Wert referenziert werden soll | 20000623 | ||
2 | ![]() |
UNIT_REF | Value transfer | Type reference (TYPE) | REF TO DATA | Datenreferenz, zeigt auf Einheit der Komponente | 20000623 | ||
3 | ![]() |
VALUE_REF | Value transfer | Type reference (TYPE) | REF TO DATA | Datenrererenz, zeigt auf den Wert der Komponente | 20000623 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ändernder Zugriff auf Container nicht erlaubt | 20000703 | |
2 | ![]() |
Element darf nicht verändert werden | 20000703 | |
3 | ![]() |
Elementdefinition (z.B. Typname) ist ungültig | 20000703 | |
4 | ![]() |
Elementdefinition (z.B. Typname) ist ungültig | 20000703 |
Method LIST_NAMES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
LIST_CHANGING | Call by reference | Type reference (TYPE) | XFELD | 'X' | Changing-Parameter auflisten | 20000621 | |
2 | ![]() |
LIST_EXPORT | Call by reference | Type reference (TYPE) | XFELD | 'X' | Exportparameter auflisten | 20000621 | |
3 | ![]() |
LIST_IMPORT | Call by reference | Type reference (TYPE) | XFELD | 'X' | Importparameter auflisten | 20000621 | |
4 | ![]() |
LIST_OTHERS | Call by reference | Type reference (TYPE) | XFELD | 'X' | Elemente ohne Parametereigenschaften auflisten | 20000621 | |
5 | ![]() |
LIST_RETURNING | Call by reference | Type reference (TYPE) | XFELD | 'X' | Returning-Parameter auflisten | 20000621 | |
6 | ![]() |
NAMES | Value transfer | Type reference (TYPE) | SWFDNAMTAB | Liste mit Namen zutreffender Elemente | 20000621 |
Method LIST_NAMES on Interface IF_SWF_IFS_PARAMETERS has no exception.
Method SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
NAME | Value transfer | Type reference (TYPE) | SWFDNAME | Name des Parametes, deren Wert gesetzt werden soll | 20000623 | ||
2 | ![]() |
UNIT | Call by reference | Type reference (TYPE) | ANY | Einheit | 20000623 | ||
3 | ![]() |
VALUE | Call by reference | Type reference (TYPE) | ANY | Wert | 20000623 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ändernder Zugriff nicht erlaubt | 20000623 | |
2 | ![]() |
Wert / Einheit darf nicht verändert werden | 20000623 | |
3 | ![]() |
Elementdefinition ist ungültig (interner Fehler) | 20000623 | |
4 | ![]() |
Angegebener Name ist unbekannt | 20000623 | |
5 | ![]() |
Typkonflikt zwischen Wert und Aktualparameter | 20000623 | |
6 | ![]() |
Typkonflikt zwischen Einheit und Aktualparameter | 20000623 |
Method SET_REF Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
COPY | Call by reference | Type reference (TYPE) | XFELD | SPACE | 'X' referenzierten Wert kopieren, ' ' Referenz übernehmen | 20000623 | |
2 | ![]() |
NAME | Value transfer | Type reference (TYPE) | SWFDNAME | Name der zu Komponente, deren Wert gesetzt werden soll | 20000623 | ||
3 | ![]() |
UNIT_REF | Call by reference | Type reference (TYPE) | REF TO DATA | Datenreferenz, zeigt auf Einheit der Komponente | 20000623 | ||
4 | ![]() |
VALUE_REF | Call by reference | Type reference (TYPE) | REF TO DATA | Datenrererenz, zeigt auf den zu setzenden Wert | 20000623 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ändernder Zugriff auf Container nicht erlaubt | 20000623 | |
2 | ![]() |
Element darf nicht verändert werden | 20000623 | |
3 | ![]() |
Elementdefinition (z.B. Typname) ist ungültig | 20000623 | |
4 | ![]() |
Typkonflikt zwischen Wert und Aktualparameter | 20000623 | |
5 | ![]() |
Typkonflikt zwischen Einheit und Aktualparameter | 20000623 |
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 610 |