SAP ABAP Interface IF_SWF_CCMS_STRUCTURE (CCMS: Definition of the Internal Tree Structure)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷ BC-BMT-WFM (Application Component) SAP Business Workflow
⤷ SWF_ALM (Package) Workflow: Alert Monitor Connection
⤷ BC-BMT-WFM (Application Component) SAP Business Workflow
⤷ SWF_ALM (Package) Workflow: Alert Monitor Connection
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SWF_CCMS_STRUCTURE | CCMS: Tree Structure (Basis Routine) | 20060301 |
Properties
Interface | IF_SWF_CCMS_STRUCTURE | |
Short Description | CCMS: Definition of the Internal Tree Structure |
General Data
Package | SWF_ALM | Workflow: Alert Monitor Connection |
Created | 20060221 | SAP |
Last changed | 20110908 | SAP |
Unicode checks active |
Forward declarations
Interface IF_SWF_CCMS_STRUCTURE has no forward declaration.
Interfaces
Interface IF_SWF_CCMS_STRUCTURE has no interface.
Friends
Interface IF_SWF_CCMS_STRUCTURE has no friend.
Attributes
Interface IF_SWF_CCMS_STRUCTURE has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | BUILD_STRUCTURE | Instance method | Public | Method | Create and Save CCMS Structure | 20060221 |
2 | GET_METHOD_PROPERTIES_BY_ID | Instance method | Public | Method | Gets Method Information By Using the ID | 20060315 |
3 | GET_PROCESS_CATEGORY | Instance method | Public | Method | Gets Process Category | 20060301 |
4 | GET_SHORTTEXT_BY_ID | Instance method | Public | Method | Gets Short Text of a Node By Using the ID | 20060308 |
5 | GET_TID_BY_ID | Instance method | Public | Method | Gets TID Using the Internal ID (Name) | 20060221 |
Events
Interface IF_SWF_CCMS_STRUCTURE has no event.
Types
Interface IF_SWF_CCMS_STRUCTURE has no local type.
Method Signatures
Method BUILD_STRUCTURE Signature
Method BUILD_STRUCTURE on Interface IF_SWF_CCMS_STRUCTURE has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SWF_CCMS_EXCEPTION | CCMS: (Basis) Ausnahmeklasse | 20060221 |
Method GET_METHOD_PROPERTIES_BY_ID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_MTE_CLASS | Call by reference | Type reference (TYPE) | ALCUSGROUP | Alert: Customization: Name of Customization Group | 20060315 | ||
2 | Exporting | E_SECS_TIL_COLLECTING | Call by reference | Type reference (TYPE) | ALTIMSECS | Intervall für Datensammlermethode in Sekunden | 20060315 | ||
3 | Exporting | E_SECS_WARMUPTIME | Call by reference | Type reference (TYPE) | ALTIMSECS | Aufwärmzeit, in der Alerts ignoriert werden | 20060315 | ||
4 | Exporting | E_SEC_UNTIL_SET_INACTIVE | Call by reference | Type reference (TYPE) | ALTIMSECS | Zeit in Sekunden für Deaktivierung | 20060315 | ||
5 | Exporting | E_TOOL_ANALYZE | Call by reference | Type reference (TYPE) | ALTOOLKEY | Logischer Name der Analysemethode im CCMS | 20060315 | ||
6 | Exporting | E_TOOL_COLLECTING | Call by reference | Type reference (TYPE) | ALTOOLKEY | Logischer Name der Datensammelmethode im CCMS | 20060315 | ||
7 | Exporting | E_TOOL_DISPATCHER | Call by reference | Type reference (TYPE) | ALTOOLDISP | Tooldispatcher für Hintergrund oder Dialog | 20060315 | ||
8 | Exporting | E_TOOL_ONALERT | Call by reference | Type reference (TYPE) | ALTOOLKEY | Logischer Name der Autoreaktionsmethode im CCMS | 20060315 | ||
9 | Importing | I_ID | Call by reference | Type reference (TYPE) | SWF_CCMS_ID | Interne ID für den CCMS-Knoten | 20060315 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SWF_CCMS_EXCEPTION | CCMS: (Basis) Ausnahmeklasse | 20060315 |
Method GET_PROCESS_CATEGORY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | R_PROCCAT | Value transfer | Type reference (TYPE) | SWD_PROCCAT | Prozesskategorie | 20060301 |
Method GET_PROCESS_CATEGORY on Interface IF_SWF_CCMS_STRUCTURE has no exception.
Method GET_SHORTTEXT_BY_ID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_ID | Call by reference | Type reference (TYPE) | SWF_CCMS_ID | Interne ID für den CCMS-Knoten | 20060308 | ||
2 | Returning | R_SHORTTEXT | Value transfer | Type reference (TYPE) | ALMCNAME | Alert: Name eines Monitorkontextes | 20060308 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SWF_CCMS_EXCEPTION | CCMS: (Basis) Ausnahmeklasse | 20060308 |
Method GET_TID_BY_ID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | I_ID | Call by reference | Type reference (TYPE) | SWF_CCMS_ID | Interne ID für den CCMS-Knoten | 20060221 | ||
2 | Returning | R_TID | Value transfer | Type reference (TYPE) | ALGLOBTID | Alert: global monitoring type identifier | 20060221 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_SWF_CCMS_EXCEPTION | CCMS: (Basis) Ausnahmeklasse | 20060221 |
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 640 |