SAP ABAP Interface IF_LO_UI_LIST (Interface for modifying WD List)
Hierarchy
☛
SAP_APPL (Software Component) Logistics and Accounting
⤷
SD-SLS (Application Component) Sales
⤷
ERP_SLS_LO_OIF (Package) Lean Order OIF

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_LO_UI_LIST | class for modifying WD list | 20120201 |
Properties
Interface | IF_LO_UI_LIST | |
Short Description | Interface for modifying WD List |
General Data
Package | ERP_SLS_LO_OIF | Lean Order OIF |
Created | 20120201 | SAP |
Last changed | 20130531 | SAP |
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ABAP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Interface IF_LO_UI_LIST has no interface.
Friends
Interface IF_LO_UI_LIST has no friend.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | GC_FIXED_POS_LEFT | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | 02 | Web Dynpro: TableColumnFixedPosition | 20120201 | |
2 | GC_FIXED_POS_NOT | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | 01 | Web Dynpro: TableColumnFixedPosition | 20120201 | |
3 | GC_FIXED_POS_RIGHT | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | 03 | Web Dynpro: TableColumnFixedPosition | 20120201 | |
4 | GC_INVISIBLE | Constant | Public | Type reference (TYPE) | WDUI_VISIBILITY | 01 | Web Dynpro: Visibility | 20120201 | |
5 | GC_TCOL_HALIGN_AUTO | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | 00 | Web Dynpro: TableColumnHAlign | 20120201 | |
6 | GC_TCOL_HALIGN_BOL | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | 07 | Web Dynpro: TableColumnHAlign | 20120201 | |
7 | GC_TCOL_HALIGN_CENTER | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | 01 | Web Dynpro: TableColumnHAlign | 20120201 | |
8 | GC_TCOL_HALIGN_EOL | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | 05 | Web Dynpro: TableColumnHAlign | 20120201 | |
9 | GC_TCOL_HALIGN_LEFT | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | 04 | Web Dynpro: TableColumnHAlign | 20120201 | |
10 | GC_TCOL_HALIGN_RIGHT | Constant | Public | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | 06 | Web Dynpro: TableColumnHAlign | 20120201 | |
11 | GC_TV_HALIGN_AUTO | Constant | Public | Type reference (TYPE) | WDUI_INPUT_FIELD_ALIGNMENT | 03 | Web Dynpro: TableColumnHAlign | 20120201 | |
12 | GC_TV_HALIGN_BOL | Constant | Public | Type reference (TYPE) | WDUI_INPUT_FIELD_ALIGNMENT | 07 | Web Dynpro: TableColumnHAlign | 20120201 | |
13 | GC_TV_HALIGN_CENTER | Constant | Public | Type reference (TYPE) | WDUI_INPUT_FIELD_ALIGNMENT | 01 | Web Dynpro: TableColumnHAlign | 20120201 | |
14 | GC_TV_HALIGN_EOL | Constant | Public | Type reference (TYPE) | WDUI_INPUT_FIELD_ALIGNMENT | 05 | Web Dynpro: TableColumnHAlign | 20120201 | |
15 | GC_TV_HALIGN_LEFT | Constant | Public | Type reference (TYPE) | WDUI_INPUT_FIELD_ALIGNMENT | 04 | Web Dynpro: TableColumnHAlign | 20120201 | |
16 | GC_TV_HALIGN_RIGHT | Constant | Public | Type reference (TYPE) | WDUI_INPUT_FIELD_ALIGNMENT | 06 | Web Dynpro: TableColumnHAlign | 20120201 | |
17 | GC_VISIBLE | Constant | Public | Type reference (TYPE) | WDUI_VISIBILITY | 02 | Web Dynpro: Visibility | 20120201 | |
18 | GV_OBJECT_ID | Instance attribute | Public | Type reference (TYPE) | TABNAME | Table Name | 20120201 | ||
19 | GV_OBJECT_PARENT | Instance attribute | Public | Type reference (TYPE) | TABNAME | Table Name | 20120201 |
Methods
Events
Interface IF_LO_UI_LIST has no event.
Types
Interface IF_LO_UI_LIST has no local type.
Method Signatures
Method CREATE_COLUMN_CB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120202 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120202 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120202 | ||
4 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120202 | |
5 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120202 | |
6 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120202 | ||
7 | ![]() |
IV_READONLY | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120202 | |
8 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120202 | |
9 | ![]() |
IV_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120202 | |||
10 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120202 | ||
11 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120202 | |||
12 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120202 | |||
13 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120202 |
Method CREATE_COLUMN_CB on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_DDLB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IT_VALUE_SET | Call by reference | Type reference (TYPE) | WDY_KEY_VALUE_LIST | Business Server Pages (BSP) Value List Search Help | 20120204 | ||
2 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120203 | ||
3 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
4 | ![]() |
IV_DISPLAY_KEY | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120203 | |
5 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120203 | ||
6 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | Web Dynpro: TableColumnFixedPosition | 20120203 | ||
7 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | Web Dynpro: TableColumnHAlign | 20120203 | ||
8 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120203 | ||
9 | ![]() |
IV_READONLY | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120203 | |
10 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120203 | |
11 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120203 | ||
12 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
13 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
14 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120203 |
Method CREATE_COLUMN_DDLB on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_GCB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120203 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120203 | ||
4 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120203 | |
5 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120203 | |
6 | ![]() |
IV_READONLY | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120319 | |
7 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120203 | |
8 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120319 | ||
9 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120319 | |||
10 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
11 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120203 |
Method CREATE_COLUMN_GCB on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_GFD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120202 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120202 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120202 | ||
4 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120202 | |
5 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120202 | |
6 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120202 | |
7 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120319 | ||
8 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120319 | |||
9 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120202 | |||
10 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120202 |
Method CREATE_COLUMN_GFD on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_GL2A Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_ACTION | Call by reference | Type reference (TYPE) | STRING | 20120320 | |||
2 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120320 | ||
3 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120320 | |||
4 | ![]() |
IV_ENABLED | Call by reference | Type reference (TYPE) | FLAG | 'X' | General Flag | 20120320 | |
5 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120320 | ||
6 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120320 | |
7 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120320 | |
8 | ![]() |
IV_PARAM | Call by reference | Type reference (TYPE) | STRING | 20120320 | |||
9 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120320 | |
10 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120320 | ||
11 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120320 | |||
12 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120320 | |||
13 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120320 |
Method CREATE_COLUMN_GL2A on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_GL2U Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | 20120328 | |||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120328 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | 20120328 | |||
4 | ![]() |
IV_FIELD_URL | Call by reference | Type reference (TYPE) | FIELDNAME | 20120328 | |||
5 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | 20120328 | ||
6 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | 20120328 | ||
7 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | 20120328 | ||
8 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | 20120328 | |||
9 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120328 | |||
10 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120328 | |||
11 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120328 |
Method CREATE_COLUMN_GL2U on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_GTV Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120203 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120203 | ||
4 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120203 | |
5 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120203 | |
6 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120203 | |
7 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120320 | ||
8 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120320 | |||
9 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
10 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120203 |
Method CREATE_COLUMN_GTV on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_IF Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120201 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120201 | ||
4 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120201 | |
5 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_AUTO | Web Dynpro: TableColumnHAlign | 20120201 | |
6 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120201 | ||
7 | ![]() |
IV_READONLY | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120201 | |
8 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120201 | |
9 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120201 | ||
10 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
11 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
12 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120201 |
Method CREATE_COLUMN_IF on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_L2A Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_ACTION | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
2 | ![]() |
IV_ACTION_ID | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
3 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120203 | ||
4 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
5 | ![]() |
IV_ENABLED | Call by reference | Type reference (TYPE) | FLAG | 'X' | General Flag | 20120203 | |
6 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120320 | ||
7 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120203 | |
8 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120203 | |
9 | ![]() |
IV_IMAGE | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
10 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120320 | ||
11 | ![]() |
IV_PARAM | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
12 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120203 | |
13 | ![]() |
IV_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
14 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120203 | ||
15 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
16 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120203 | |||
17 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120203 |
Method CREATE_COLUMN_L2A on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_L2U Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120321 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120321 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120321 | ||
4 | ![]() |
IV_FIELD_URL | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120321 | ||
5 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120321 | |
6 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_CENTER | Web Dynpro: TableColumnHAlign | 20120321 | |
7 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120321 | ||
8 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120321 | |
9 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120321 | ||
10 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120321 | |||
11 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120321 | |||
12 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120321 |
Method CREATE_COLUMN_L2U on Interface IF_LO_UI_LIST has no exception.
Method CREATE_COLUMN_TV Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CAPTION_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120201 | ||
2 | ![]() |
IV_CAPTION_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
3 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120201 | ||
4 | ![]() |
IV_FIXEDPOS | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_FIXED_POS | GC_FIXED_POS_NOT | Web Dynpro: TableColumnFixedPosition | 20120201 | |
5 | ![]() |
IV_HALIGN | Call by reference | Type reference (TYPE) | WDUI_TABLE_COLUMN_HALIGN | GC_TCOL_HALIGN_AUTO | Web Dynpro: TableColumnHAlign | 20120201 | |
6 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120201 | ||
7 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120201 | |
8 | ![]() |
IV_TOOLTIP_DDIC | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120201 | ||
9 | ![]() |
IV_TOOLTIP_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
10 | ![]() |
IV_VARIANT | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
11 | ![]() |
IV_WIDTH | Call by reference | Type reference (TYPE) | STRING | 20120201 |
Method CREATE_COLUMN_TV on Interface IF_LO_UI_LIST has no exception.
Method CREATE_TBITEM_BTN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IF_SELECTION | Call by reference | Type reference (TYPE) | FLAG | 'X' | General Flag | 20120201 | |
2 | ![]() |
IV_ACTION | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
3 | ![]() |
IV_ACTION_ID | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
4 | ![]() |
IV_ENABLED | Call by reference | Type reference (TYPE) | FLAG | 'X' | General Flag | 20120229 | |
5 | ![]() |
IV_IMAGE | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
6 | ![]() |
IV_PARAM | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
7 | ![]() |
IV_RIGHT | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120207 | |
8 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | 0 | Natural Number | 20120201 | |
9 | ![]() |
IV_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 |
Method CREATE_TBITEM_BTN on Interface IF_LO_UI_LIST has no exception.
Method CREATE_TBITEM_BTNC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IF_REPEAT_SELECTED_ACTION | Call by reference | Type reference (TYPE) | WDY_BOOLEAN | ABAP_FALSE | Replacement for Real Boolean Type: 'X' == True '' == False | 20120201 | |
2 | ![]() |
IT_ACTION | Call by reference | Type reference (TYPE) | TDT_LOUI_ACTION_INFO | Table Type for Structure TDS_LOUI_ACTION_INFO | 20120201 | ||
3 | ![]() |
IV_ENABLED | Call by reference | Type reference (TYPE) | FLAG | 'X' | General Flag | 20120229 | |
4 | ![]() |
IV_ID | Call by reference | Type reference (TYPE) | STRING | 20120201 | |||
5 | ![]() |
IV_IMAGE | Call by reference | Type reference (TYPE) | STRING | 20120229 | |||
6 | ![]() |
IV_RIGHT | Call by reference | Type reference (TYPE) | FLAG | SPACE | General Flag | 20120207 | |
7 | ![]() |
IV_SEQNO | Call by reference | Type reference (TYPE) | INT4 | Natural Number | 20120201 | ||
8 | ![]() |
IV_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 |
Method CREATE_TBITEM_BTNC on Interface IF_LO_UI_LIST has no exception.
Method GET_POPIN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RR_POPIN | Value transfer | Object reference (TYPE REF TO) | IF_LO_UI_FORM | Interface for modifying WD Form | 20120312 |
Method GET_POPIN on Interface IF_LO_UI_LIST has no exception.
Method SET_FIELD_ATTRIBUTES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_FIELD_NAME | Call by reference | Type reference (TYPE) | FIELDNAME | Field Name | 20120203 | ||
2 | ![]() |
IV_NULL_AS_BLANK | Call by reference | Type reference (TYPE) | WDY_ATTRFORM_NULL | Attribute Formatting: Zeros as Blanks | 20120203 | ||
3 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | TABNAME | Table Name | 20120203 | ||
4 | ![]() |
IV_VALUE_HELP_MODE | Call by reference | Type reference (TYPE) | I | 20120317 | |||
5 | ![]() |
IV_VALUE_HELP_NAME | Call by reference | Type reference (TYPE) | CSEQUENCE | 20120317 |
Method SET_FIELD_ATTRIBUTES on Interface IF_LO_UI_LIST has no exception.
Method SET_HGB Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_HEIGHT | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120403 |
Method SET_HGB on Interface IF_LO_UI_LIST has no exception.
Method SET_HGT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_HEIGHT | Call by reference | Type reference (TYPE) | NUMC2 | Two digit number | 20120403 |
Method SET_HGT on Interface IF_LO_UI_LIST has no exception.
Method SET_LIST_CAPTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_TEXT | Call by reference | Type reference (TYPE) | STRING | 20120201 |
Method SET_LIST_CAPTION on Interface IF_LO_UI_LIST has no exception.
Method SET_NO_EMPTY_ROWS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_NO_EMPTY_ROWS | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_TRUE | 20120320 |
Method SET_NO_EMPTY_ROWS on Interface IF_LO_UI_LIST has no exception.
Method SET_SCROLLABLE_COL_COUNT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_COUNT | Call by reference | Type reference (TYPE) | I | 20120201 |
Method SET_SCROLLABLE_COL_COUNT on Interface IF_LO_UI_LIST has no exception.
Method SET_VISIBLE_ROW_COUNT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_COUNT | Call by reference | Type reference (TYPE) | I | 10 | 20120203 |
Method SET_VISIBLE_ROW_COUNT on Interface IF_LO_UI_LIST has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 607 |