SAP ABAP Interface IF_EX_WPS_CONNECTION (BAdI Interface IF_EX_WPS_CONNECTION)
Hierarchy
☛
BBPCRM (Software Component) BBPCRM
⤷ CRM (Application Component) Customer Relationship Management
⤷ CRM_APPLICATION (Package) All CRM Components Without Special Structure Packages
⤷ IWO1 (Package) Appl. Development R/3 Plant Maintenance Order Processing
⤷ CRM (Application Component) Customer Relationship Management
⤷ CRM_APPLICATION (Package) All CRM Components Without Special Structure Packages
⤷ IWO1 (Package) Appl. Development R/3 Plant Maintenance Order Processing
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_WPS_CONNECTION | BAdI Class CL_EX_WPS_CONNECTION | 20041126 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_PLM_WPS_CONNECTION | Imp. Class for BAdI Imp. PLM_WPS_CONNECTION | 20030409 |
Properties
Interface | IF_EX_WPS_CONNECTION | |
Short Description | BAdI Interface IF_EX_WPS_CONNECTION |
General Data
Package | IWO1 | Appl. Development R/3 Plant Maintenance Order Processing |
Created | 20030416 | SAP |
Last changed | 20100310 | SAP |
Unicode checks active |
Forward declarations
Interface IF_EX_WPS_CONNECTION has no forward declaration.
Interfaces
Interface IF_EX_WPS_CONNECTION has no interface.
Friends
Interface IF_EX_WPS_CONNECTION has no friend.
Attributes
Interface IF_EX_WPS_CONNECTION has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ACTIVE_CHECK_WPS_CC | Instance method | Public | Method | Check Whether CC or WPS Active | 20030506 |
2 | CHECK_CHANGE_OF_FL | Instance method | Public | Method | Check of Change of Functional Location | 20030416 |
3 | CHECK_CHANGE_OF_REVNR | Instance method | Public | Method | Check of Change of Revision Number | 20030416 |
4 | IQS0_DYNPRO_MOD | Instance method | Public | Method | 20050503 | |
5 | NOTIFICATION_CLOSE | Instance method | Public | Method | Notification Completion for MEB-Controlled Notifications | 20030930 |
6 | REVISION_DATES | Instance method | Public | Method | Copy Deadlines from Revision | 20030416 |
7 | REVISION_F4 | Instance method | Public | Method | F4 Handling for Revision | 20070321 |
8 | RIAUFK20_SELECT | Instance method | Public | Method | Select orders via WPS cross reference for core order reports | 20050428 |
9 | RIAUFK20_SET_DATA | Instance method | Public | Method | 20050504 | |
10 | ROUTING_EXPLOSION | Instance method | Public | Method | Deviating Logic for Task List Explosion | 20030926 |
11 | VIQMEL_REVNR | Instance method | Public | Method | Check the Revision Number | 20030416 |
12 | VIQMEL_TASKLIST | Instance method | Public | Method | 20050422 | |
13 | VIQMEL_TASKLIST_DATE | Instance method | Public | Method | 20050426 |
Events
Interface IF_EX_WPS_CONNECTION has no event.
Types
Interface IF_EX_WPS_CONNECTION has no local type.
Method Signatures
Method ACTIVE_CHECK_WPS_CC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_CC_ACTIVE | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20030506 | ||
2 | Exporting | EV_WPS_ACTIVE | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20030506 |
Method ACTIVE_CHECK_WPS_CC on Interface IF_EX_WPS_CONNECTION has no exception.
Method CHECK_CHANGE_OF_FL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IV_IWERK | Call by reference | Type reference (TYPE) | IWERK | Instandhaltungsplanungswerk | 20030416 | ||
2 | Importing | IV_REVNR | Call by reference | Type reference (TYPE) | REVNI | Revision Instandhaltung und Kundenservice | 20030416 | ||
3 | Importing | IV_TPLNR | Call by reference | Type reference (TYPE) | TPLNR | Technischer Platz | 20030416 |
Method CHECK_CHANGE_OF_FL on Interface IF_EX_WPS_CONNECTION has no exception.
Method CHECK_CHANGE_OF_REVNR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_CAUFVD | Call by reference | Type reference (TYPE) | CAUFVD | Dialogstruktur fuer Auftragskoepfe und -position | 20030416 | ||
2 | Importing | IS_CAUFVD | Call by reference | Type reference (TYPE) | CAUFVD | Dialogstruktur fuer Auftragskoepfe und -position | 20030416 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CHANGE_NOT_ALLOWED | Änderung der Revisionsnummer nicht erlaubt | 20030416 |
Method IQS0_DYNPRO_MOD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CS_SCREEN | Call by reference | Type reference (TYPE) | SCREEN | 20050504 | |||
2 | Importing | IS_VIQMEL | Call by reference | Type reference (TYPE) | VIQMEL | 20050506 |
Method IQS0_DYNPRO_MOD on Interface IF_EX_WPS_CONNECTION has no exception.
Method NOTIFICATION_CLOSE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_SKIP_STANDARDLOGIC | Call by reference | Type reference (TYPE) | XCHAR | 'X' --> Skip Standardlogic to build H_TAB | 20030930 | ||
2 | Importing | I_ORDER_NUMBER | Call by reference | Type reference (TYPE) | AFIH-AUFNR | 20030930 | |||
3 | Changing | QMEL_TAB | Value transfer | Type reference (TYPE) | QMEL_ESSENCE_TAB | wichtige Felder Tabelle Qmel | 20031017 |
Method NOTIFICATION_CLOSE on Interface IF_EX_WPS_CONNECTION has no exception.
Method REVISION_DATES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EV_LTRMN | Call by reference | Type reference (TYPE) | LTRMN | Gewünschter Endtermin | 20030416 | ||
2 | Exporting | EV_LTRUR | Call by reference | Type reference (TYPE) | LTRUR | Gewünschte Endtermin-Uhrzeit | 20030416 | ||
3 | Exporting | EV_RC | Call by reference | Type reference (TYPE) | SYSUBRC | Rückgabewert, Rückgabewert nach ABAP-Anweisungen | 20030416 | ||
4 | Exporting | EV_REVNR | Call by reference | Type reference (TYPE) | REVNI | Revision Instandhaltung und Kundenservice | 20030416 | ||
5 | Exporting | EV_STRMN | Call by reference | Type reference (TYPE) | STRMN | Gewünschter Starttermin | 20030416 | ||
6 | Exporting | EV_STRUR | Call by reference | Type reference (TYPE) | STRUR | Gewünschte Startuhrzeit | 20030416 | ||
7 | Importing | IV_MESS | Call by reference | Type reference (TYPE) | CHAR2 | Datumsart | 20030416 | ||
8 | Importing | IV_PLANT | Call by reference | Type reference (TYPE) | IWERK | Instandhaltungsplanungswerk | 20030416 | ||
9 | Importing | IV_REVNR | Call by reference | Type reference (TYPE) | REVNI | Revision Instandhaltung und Kundenservice | 20030416 |
Method REVISION_DATES on Interface IF_EX_WPS_CONNECTION has no exception.
Method REVISION_F4 Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_ACTIVE | Call by reference | Type reference (TYPE) | CHAR1 | allgemeines flag | 20070321 | ||
2 | Exporting | E_REVNR | Call by reference | Type reference (TYPE) | T352R-REVNR | Revision Instandhaltung und Kundenservice | 20070321 | ||
3 | Importing | I_IWERK | Call by reference | Type reference (TYPE) | T352R-IWERK | Instandhaltungsplanungswerk | 20070321 |
Method REVISION_F4 on Interface IF_EX_WPS_CONNECTION has no exception.
Method RIAUFK20_SELECT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CT_AUFNR | Call by reference | Type reference (TYPE) | RANGE_AUFNR_TAB | 20050504 | |||
2 | Changing | CT_QMNUM | Call by reference | Type reference (TYPE) | RANGE_QMNUM_TAB | 20050504 |
Method RIAUFK20_SELECT on Interface IF_EX_WPS_CONNECTION has no exception.
Method RIAUFK20_SET_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CT_VIAUFKST | Call by reference | Type reference (TYPE) | VIAUFKST_IFLOS_TAB | 20050504 |
Method RIAUFK20_SET_DATA on Interface IF_EX_WPS_CONNECTION has no exception.
Method ROUTING_EXPLOSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | E_CAUFVD | Value transfer | Type reference (TYPE) | CAUFVD | Dialogstruktur fuer Auftragskoepfe und -position | 20041126 | ||
2 | Exporting | E_SUPPRESS_TL_EXPLOSION | Value transfer | Type reference (TYPE) | XFLAG | 'X' --> Exit; | 20030926 | ||
3 | Importing | I_CAUFVD | Call by reference | Type reference (TYPE) | CAUFVD | Dialogstruktur fuer Auftragskoepfe und -position | 20030926 | ||
4 | Importing | I_FLG_REFRESH | Call by reference | Type reference (TYPE) | RC27X-FLG_SEL | Zurücksetzen der bisherigen Arbeitsplansegmente | 20030926 | ||
5 | Importing | I_NOTIFICATION_EXPLODE | Call by reference | Type reference (TYPE) | RC27X-FLG_SEL | Arbeitsplanauflösung für Meldungen | 20030926 | ||
6 | Importing | I_NO_STRAT | Call by reference | Type reference (TYPE) | CHAR1 | Kopf ohne Strategiebezug | 20030926 | ||
7 | Importing | I_OBZAE_IMP | Call by reference | Type reference (TYPE) | OPROL-OBZAE | Zaehler zur Objektliste | 20030926 | ||
8 | Importing | I_PRODCOST | Call by reference | Type reference (TYPE) | TCA11-FLG_OPR | Kennzeichen: Vorgänge | 20030926 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ESC_SELECTION | 20041126 | ||
2 | NO_OPERATION | 20041126 |
Method VIQMEL_REVNR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IS_VIQMEL | Call by reference | Type reference (TYPE) | VIQMEL | Generierte Tabelle zum View VIQMEL | 20030416 | ||
2 | Importing | IS_VIQMEL_OLD | Call by reference | Type reference (TYPE) | VIQMEL | Generierte Tabelle zum View VIQMEL | 20030416 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CHANGE_NOT_ALLOWED | Änderung der Revisionsnummer nicht erlaubt | 20030416 |
Method VIQMEL_TASKLIST Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | CS_VIQMEL | Call by reference | Type reference (TYPE) | VIQMEL | 20050506 | |||
2 | Changing | C_PLANTEXT | Call by reference | Type reference (TYPE) | RMIPM-PLANTEXT | 20050422 | |||
3 | Changing | C_PLNAL | Call by reference | Type reference (TYPE) | PLKO-PLNAL | 20050422 | |||
4 | Changing | C_PLNNR | Call by reference | Type reference (TYPE) | PLKO-PLNNR | 20050422 | |||
5 | Changing | C_PLNTY | Call by reference | Type reference (TYPE) | PLKO-PLNTY | 20050422 |
Method VIQMEL_TASKLIST on Interface IF_EX_WPS_CONNECTION has no exception.
Method VIQMEL_TASKLIST_DATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Changing | C_STTAG | Call by reference | Type reference (TYPE) | DATUM | 20050426 | |||
2 | Importing | IS_VIQMEL | Call by reference | Type reference (TYPE) | VIQMEL | 20050426 |
Method VIQMEL_TASKLIST_DATE on Interface IF_EX_WPS_CONNECTION has no exception.
History
Last changed by/on | SAP | 20100310 |
SAP Release Created in | 470 |