Hierarchy
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_CPS_EXECUTION_D | BAdI Class CL_EX_CPS_EXECUTION_D | 20041227 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_CPS_EXECUTION_I | Imp. Class for BAdI Imp. CPS_EXECUTION_I | 20030219 |
Properties
| Interface | IF_EX_CPS_EXECUTION_D | |
| Short Description | IF f. PI Set/X Step Connection to Master Recipes/Task List |
General Data
| Package | CPC | R/3 Application Development: PP Task Lists Master Recipes |
| Created | 20010925 | SAP |
| Last changed | 20050219 | SAP |
| Unicode checks active |
Forward declarations
Interface IF_EX_CPS_EXECUTION_D has no forward declaration.
Interfaces
Interface IF_EX_CPS_EXECUTION_D has no interface.
Friends
Interface IF_EX_CPS_EXECUTION_D has no friend.
Attributes
Interface IF_EX_CPS_EXECUTION_D has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Check if Changes Were Made | 20010925 | |
| 2 | Instance method | Public | Method | Check if Changes Were Made at Current X Steps | 20010925 | |
| 3 | Instance method | Public | Method | Filter Change Documents | 20010926 | |
| 4 | Instance method | Public | Method | Determine Object IDs for Change Documents of X Steps | 20010926 | |
| 5 | Instance method | Public | Method | Determine Text for Object ID of Change Documents | 20010926 | |
| 6 | Instance method | Public | Method | Determine Formatting Routine for Change Documents | 20010928 | |
| 7 | Instance method | Public | Method | Determine Change Numbers | 20010928 | |
| 8 | Instance method | Public | Method | Specify Task Lists for Change Number | 20010926 | |
| 9 | Instance method | Public | Method | Change Number Shift | 20010926 | |
| 10 | Instance method | Public | Method | Check if Change Number May Be Shifted | 20010926 | |
| 11 | Instance method | Public | Method | Check if Change Number Was Used | 20010926 | |
| 12 | Instance method | Public | Method | Determine Change Numbers | 20011015 | |
| 13 | Instance method | Public | Method | Concatenate Execution Steps | 20011004 | |
| 14 | Instance method | Public | Method | Consistency Check | 20010925 | |
| 15 | Instance method | Public | Method | Copy | 20010926 | |
| 16 | Instance method | Public | Method | Copy from Exection Step Trees: Table-Supp. Context Switch | 20030324 | |
| 17 | Instance method | Public | Method | Edit Execution Steps (Without Editor) | 20010925 | |
| 18 | Instance method | Public | Method | Call Up Editor for Execution Step Maintenance | 20010925 | |
| 19 | Instance method | Public | Method | Determine Processing Type (PI or execution steps) | 20010925 | |
| 20 | Instance method | Public | Method | Determine Existence of PI Set/Execution Step for Header | 20010925 | |
| 21 | Instance method | Public | Method | Determine PI Set/X Step Existence for Header Incl. Validity | 20010925 | |
| 22 | Instance method | Public | Method | PI Set/Execution Step Completion | 20011008 | |
| 23 | Instance method | Public | Method | Change Operation Context in PI Set/Execution Step | 20010928 | |
| 24 | Instance method | Public | Method | Read History | 20010926 | |
| 25 | Instance method | Public | Method | Output History | 20010926 | |
| 26 | Instance method | Public | Method | History Output: Object Text | 20011015 | |
| 27 | Instance method | Public | Method | Initialize PI Sets/Execution Steps | 20011008 | |
| 28 | Instance method | Public | Method | XStep Migration | 20011009 | |
| 29 | Instance method | Public | Method | Change Operation Context in PI Set/Execution Step | 20010926 | |
| 30 | Instance method | Public | Method | Change Operation Context in PI Set/Execution Step | 20011011 | |
| 31 | Instance method | Public | Method | Change Operation Context in PI Set/Execution Step | 20011011 | |
| 32 | Instance method | Public | Method | Determine Consistency of Profile for Task List Group | 20010925 | |
| 33 | Instance method | Public | Method | Determine Processing Type from Profile (PI, PS/ES) | 20010926 | |
| 34 | Instance method | Public | Method | Determine GUID of PI Set/Execution Step Tree | 20010928 | |
| 35 | Instance method | Public | Method | Remove PI Sets/X Steps Loaded from Memory (Without Saving!) | 20010926 | |
| 36 | Instance method | Public | Method | Update Registration | 20010925 | |
| 37 | Instance method | Public | Method | Archive in Reorganization | 20010926 | |
| 38 | Instance method | Public | Method | Delete in Reorganization | 20010926 | |
| 39 | Instance method | Public | Method | Display PI Sets/Execution Steps in Print Report | 20010926 | |
| 40 | Instance method | Public | Method | Simulation | 20010926 | |
| 41 | Instance method | Public | Method | Syntax Check | 20010926 |
Events
Interface IF_EX_CPS_EXECUTION_D has no event.
Types
Interface IF_EX_CPS_EXECUTION_D has no local type.
Method Signatures
Method CHANGED Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FLG_CHANGED | Value transfer | Type reference (TYPE) | FLAG | X = XStep wurde geändert | 20010925 | |||
| 2 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010925 | |||
| 3 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 4 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method CHANGED_FOR_GROUP Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CHANGES_IN_PLAN | Value transfer | Type reference (TYPE) | PLAN_CHECK_TAB | Selektion von Planalternativen | 20011011 | |||
| 2 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 3 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method CHGDOC_FILTER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | BELEG_TAB | Call by reference | Type reference (TYPE) | BELEG_TAB | Belegtabelle für Pläne | 20010926 | |||
| 2 | FLG_PV | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = PV selektiert | 20010926 | ||
| 3 | FLG_PVM | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = zusätzlich Merkmale selektiert | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method CHGDOC_OBJID_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | OBJID_TAB | Call by reference | Type reference (TYPE) | PLANOBJ_TAB | Objekt-IDs für Änderungsbelegselektion | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method CHGDOC_OBJTXT_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FNAME_WA | Value transfer | Type reference (TYPE) | FNAME | Tabelle mit Feldnamen | 20010926 | |||
| 2 | LANGU | Value transfer | Type reference (TYPE) | SY-LANGU | SY-LANGU | SAP-System, aktuelle Sprache | 20010926 | ||
| 3 | OBJID | Value transfer | Type reference (TYPE) | I | Objekt-ID | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 | ||
| 2 | Zur Sprache wurde kein Titel gefunden | 20010926 |
Method CHGDOC_PROG_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | FUNCT | Value transfer | Type reference (TYPE) | CHAR1 | A = Belegaufbereitung B = Ausgabeaufbereitung | 20010928 | |||
| 2 | INCLUDE | Value transfer | Type reference (TYPE) | INCLUDE | ABAP-Programmname Include | 20010928 | |||
| 3 | PERFORM | Value transfer | Type reference (TYPE) | PROGRAMM | ABAP-Programmname | 20010928 | |||
| 4 | TABLE | Value transfer | Type reference (TYPE) | TABNAM | Tabellenname | 20010928 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010928 | ||
| 2 | Kein Programm gefunden | 20010928 |
Method CHGNO_DET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR_TAB | Value transfer | Type reference (TYPE) | RC280_TAB | Änderungsnummern | 20010928 | |||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | Datum gültig ab | 20010928 | |||
| 3 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010928 | |||
| 4 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010928 | |||
| 5 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010928 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010928 |
Method CHGNO_DET_ROUTINGS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010926 | |||
| 2 | AENNR_PAC_FLG | Value transfer | Type reference (TYPE) | FLAG | SPACE | Änderungsnummernpaket | 20010926 | ||
| 3 | FLG_USED | Value transfer | Type reference (TYPE) | FLAG | X = Änderungsnummer benutzt | 20010926 | |||
| 4 | PLKO_TAB | Value transfer | Type reference (TYPE) | ROUT_VALID_HEADER | Gültiger Kopf | 20010926 | |||
| 5 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | SPACE | Plangruppenzähler | 20010926 | ||
| 6 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | SPACE | Schlüssel der Plangruppe | 20010926 | ||
| 7 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | SPACE | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method CHGNO_SHIFT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010926 | |||
| 2 | AENNR_PAC_FLG | Value transfer | Type reference (TYPE) | FLAG | SPACE | Änderungsnummernpaket | 20010926 | ||
| 3 | DATUV_NEW | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 4 | DATUV_OLD | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 5 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 6 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 7 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 | ||
| 2 | Änderungsnummer konnte nicht verschoben werden | 20030325 |
Method CHGNO_SHIFT_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010926 | |||
| 2 | AENNR_PAC_FLG | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Änderungsnummernpaket | 20010926 | ||
| 3 | DATUV_NEW | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 4 | DATUV_OLD | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 5 | FLG_ERROR | Value transfer | Type reference (TYPE) | FLAG | allgemeines flag | 20010926 | |||
| 6 | FLG_WARNING | Value transfer | Type reference (TYPE) | FLAG | allgemeines flag | 20010926 | |||
| 7 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 8 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 9 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method CHGNO_USAGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010926 | |||
| 2 | AENNR_PAC_FLG | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Änderungsnummernpaket | 20010926 | ||
| 3 | FLG_USED | Value transfer | Type reference (TYPE) | FLAG | X = Änderungsnummer benutzt | 20010926 | |||
| 4 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 5 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 6 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method CHGNO_WRITE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20011015 | |||
| 2 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20011015 | |||
| 3 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20011015 | |||
| 4 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20011015 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20011015 |
Method CONCATENATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | MODE | Value transfer | Type reference (TYPE) | CHAR1 | 'A' | Modus: A = Anfügen | 20011004 | ||
| 2 | PLNAL_1 | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20011004 | |||
| 3 | PLNAL_2 | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20011004 | |||
| 4 | PLNNR_1 | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20011004 | |||
| 5 | PLNNR_2 | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20011004 | |||
| 6 | PLNTY_1 | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20011004 | |||
| 7 | PLNTY_2 | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20011004 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20011004 | ||
| 2 | Zusammenführung nicht möglich | 20011004 | ||
| 3 | Modus nicht zulässig | 20011004 |
Method CONSISTENCY_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 2 | FLG_ERROR | Value transfer | Type reference (TYPE) | FLAG | X = Error exists | 20010925 | |||
| 3 | FLG_MESSAGE | Value transfer | Type reference (TYPE) | FLAG | X = Message exists | 20010925 | |||
| 4 | FLG_REF | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Refernzierte Objekte prüfen | 20010925 | ||
| 5 | FLG_WARNING | Value transfer | Type reference (TYPE) | FLAG | X = Warning exists | 20010925 | |||
| 6 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010925 | |||
| 7 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 8 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method COPY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR_NEW | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010926 | |||
| 2 | DATUV_NEW | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 3 | DATUV_OLD | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 4 | PLNAL_NEW | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 5 | PLNAL_OLD | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 6 | PLNNR_NEW | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 7 | PLNNR_OLD | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 8 | PLNTY_NEW | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 | |||
| 9 | PLNTY_OLD | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 | ||
| 2 | Vorlage konnte nicht kopiert werden | 20010926 | ||
| 3 | Keine Vorlage vorhanden | 20010926 |
Method COPY_COMPLETE Signature
Method COPY_COMPLETE on Interface IF_EX_CPS_EXECUTION_D has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20030324 |
Method EDIT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010925 | |||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010925 | ||
| 3 | OBJECT | Value transfer | Type reference (TYPE) | CHAR1 | Objekt H = Kopf F = Folge O = Operation / Phase | 20011010 | |||
| 4 | PLFLD_NEW_WA | Value transfer | Type reference (TYPE) | PLFLD | Folge neu | 20011010 | |||
| 5 | PLFLD_OLD_WA | Value transfer | Type reference (TYPE) | PLFLD | Folge alt | 20011010 | |||
| 6 | PLKOD_NEW_WA | Value transfer | Type reference (TYPE) | PLKOD | Kopf neu | 20011010 | |||
| 7 | PLKOD_OLD_WA | Value transfer | Type reference (TYPE) | PLKOD | Kopf alt | 20011010 | |||
| 8 | PLPO_NEW_WA | Value transfer | Type reference (TYPE) | PLPOD | Vorgang neu | 20010925 | |||
| 9 | PLPO_OLD_WA | Value transfer | Type reference (TYPE) | PLPOD | Vorgang alt | 20010925 | |||
| 10 | PS_ACTIVITY | Value transfer | Type reference (TYPE) | CHAR1 | Duchgeführte Aktivität A = New, V = Changed, D = Deleted | 20011010 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Aktivität nicht durchführbar | 20010928 | ||
| 2 | Methode nicht ausführbar | 20010925 |
Method EDITOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ACTIVITY_NEW | Value transfer | Type reference (TYPE) | CHAR1 | Durchgeführte Aktivität H = Neu A = Ändern L = gelöschtmark | 20010927 | |||
| 2 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20010925 | |||
| 3 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010925 | ||
| 4 | FCODE_XSE | Value transfer | Type reference (TYPE) | FCODE | XStep-Editor Funktionscode | 20030509 | |||
| 5 | FLG_SHOW | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = PI Set nur anzeigen | 20010925 | ||
| 6 | ORIGIN | Value transfer | Type reference (TYPE) | CHAR40 | Herkunft XStep-Editoraufruf (SY-REPID + SY-DYNNR) | 20030509 | |||
| 7 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010925 | |||
| 8 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Plantyp | 20010925 | |||
| 9 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Aktivität nicht durchführbar (anzeigen, ändern, anlegen) | 20030507 | ||
| 2 | Methode nicht ausführbar | 20010925 |
Method EDIT_PRES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010928 | ||
| 2 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010925 | |||
| 3 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 4 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 | |||
| 5 | PRES | Value transfer | Type reference (TYPE) | CHAR1 | Proc. Type 0 = None, 1 = PI, 2 = PI Set/X Step, 3 = Migrat. | 20010925 | |||
| 6 | PROFILE | Value transfer | Type reference (TYPE) | PLKO-PROFIDNETZ | Profil | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method EXIST Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010925 | ||
| 2 | FLG_EXISTS | Value transfer | Type reference (TYPE) | FLAG | X = XStep-Baum zum Stichtag vorhanden | 20010925 | |||
| 3 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010925 | |||
| 4 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 5 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method EXIST_DATA Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010925 | ||
| 2 | FLG_EXISTS | Value transfer | Type reference (TYPE) | FLAG | X = Xstep-Baum zum Stichtag vorhanden | 20010925 | |||
| 3 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010925 | |||
| 4 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 5 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 | |||
| 6 | VALID_FROM_EXISTS | Value transfer | Type reference (TYPE) | PLKO-DATUV | aktueller XStep-Baum gültig seit | 20010925 | |||
| 7 | VALID_FROM_FIRST | Value transfer | Type reference (TYPE) | PLKO-DATUV | Früheste Gültigkeit eines XStep-Baumes | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method FINALIZE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20011008 | |||
| 2 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20011008 | |||
| 3 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20011008 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20011008 |
Method HDR_CONTEXT_CHANGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20011010 | |||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20011010 | ||
| 3 | PLKO_NEW_WA | Value transfer | Type reference (TYPE) | PLKOD | Plankopf neu | 20011010 | |||
| 4 | PLKO_OLD_WA | Value transfer | Type reference (TYPE) | PLKOD | Plankopf alt | 20011010 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010928 |
Method HISTORY_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUB | Value transfer | Type reference (TYPE) | PLPO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLPO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 3 | FLG_PV | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = PV selektiert | 20010926 | ||
| 4 | FLG_PVM | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = zusätzlich Merkmale selektiert | 20010926 | ||
| 5 | HIST_TAB | Value transfer | Type reference (TYPE) | HIST_TAB | Historie zum Plan | 20010926 | |||
| 6 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 7 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 8 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 | |||
| 9 | VALID_PLPO_TAB | Value transfer | Type reference (TYPE) | PLPO_TAB | Plan Vorgang, Phase, Untervorgang | 20010926 |
Method HISTORY_GET on Interface IF_EX_CPS_EXECUTION_D has no exception.
Method HISTORY_PRINT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUB | Value transfer | Type reference (TYPE) | PLPO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLPO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 3 | FLG_PV | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = PV selektiert | 20010926 | ||
| 4 | FLG_PVM | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = zusätzlich Merkmale selektiert | 20010926 | ||
| 5 | HIST_TAB | Value transfer | Type reference (TYPE) | HIST_TAB | Historie zum Plan | 20010926 | |||
| 6 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 7 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 8 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 | |||
| 9 | VALID_PLPO_TAB | Value transfer | Type reference (TYPE) | PLPO_TAB | Plan Vorgang, Phase, Untervorgang | 20010926 |
Method HISTORY_PRINT on Interface IF_EX_CPS_EXECUTION_D has no exception.
Method HISTORY_PRINT_OBJ Signature
Method HISTORY_PRINT_OBJ on Interface IF_EX_CPS_EXECUTION_D has no parameter.
Method HISTORY_PRINT_OBJ on Interface IF_EX_CPS_EXECUTION_D has no exception.
Method INITIALIZE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20011008 | |||
| 2 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20011008 | |||
| 3 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20011008 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20011008 |
Method MIGRATION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20011009 | |||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20011009 | ||
| 3 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20011009 | |||
| 4 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Plantyp | 20011009 | |||
| 5 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20011009 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Aktivität nicht durchführbar (anzeigen, ändern, anlegen) | 20011009 | ||
| 2 | Methode nicht ausführbar | 20011009 |
Method OPR_CONTEXT_CHANGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR_NEW | Value transfer | Type reference (TYPE) | PLPO-AENNR | Änderungsnummer | 20010926 | |||
| 2 | DATUV_NEW | Value transfer | Type reference (TYPE) | PLPO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 3 | PLPO_NEW_WA | Value transfer | Type reference (TYPE) | PLPOD | Neuer Vorgang | 20011010 | |||
| 4 | PLPO_OLD_WA | Value transfer | Type reference (TYPE) | PLPOD | Alter Vorgang | 20011010 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method PFL_CONTEXT_CHANGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR_NEW | Value transfer | Type reference (TYPE) | PLPO-AENNR | Änderungsnummer | 20011011 | |||
| 2 | DATUV_NEW | Value transfer | Type reference (TYPE) | PLPO-DATUV | SY-DATLO | Datum gültig ab | 20011011 | ||
| 3 | PLPO_NEW_WA | Value transfer | Type reference (TYPE) | PLFLD | Planfolge E/A-Tabelle | 20011011 | |||
| 4 | PLPO_OLD_WA | Value transfer | Type reference (TYPE) | PLFLD | Planfolge E/A-Tabelle | 20011011 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20011011 |
Method PLAN_EXTERNAL_NUMBERING_SET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | AENNR | Value transfer | Type reference (TYPE) | PLKO-AENNR | Änderungsnummer | 20011011 | |||
| 2 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20011011 | ||
| 3 | PLNNR_NEW | Value transfer | Type reference (TYPE) | PLKOD-PLNNR | Schlüssel der Plangruppe | 20011011 | |||
| 4 | PLNTY | Value transfer | Type reference (TYPE) | PLKOD-PLNTY | Plantyp | 20011011 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20011011 |
Method PROFILE_CONSISTENCY_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 2 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 | |||
| 3 | PROFILE | Value transfer | Type reference (TYPE) | PLKO-PROFIDNETZ | Task list - header | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Konsistenzfehler zum Profil | 20010928 | ||
| 2 | Methode nicht ausführbar | 20010928 |
Method PROFILE_EDIT_PRES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PRES | Value transfer | Type reference (TYPE) | CHAR1 | Bearbeitungsart: 1 = PV 2 = XSteps | 20010926 | |||
| 2 | PROFILE | Call by reference | Type reference (TYPE) | PLKO-PROFIDNETZ | Profil | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method PS_GUID_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | Datum gültig ab | 20010928 | |||
| 2 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010928 | |||
| 3 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010928 | |||
| 4 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010928 | |||
| 5 | PS_GUID | Value transfer | Type reference (TYPE) | GUID_22 | Globally Unique Identifier | 20010928 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010928 | ||
| 2 | Kein PI Set gefunden | 20010928 |
Method REFRESH Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010928 | |||
| 2 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010928 | |||
| 3 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010928 | |||
| 4 | PS_GUID | Value transfer | Type reference (TYPE) | GUID_22 | Globally Unique Identifier | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method REG_SAVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010925 | |||
| 2 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010925 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010925 |
Method REORG_ARCHIVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | HANDLE_ARCHIVE | Value transfer | Type reference (TYPE) | SY-TABIX | Interne Tabellen, aktueller Zeilenindex | 20010926 | |||
| 2 | PLAS_ARCH_TAB | Value transfer | Type reference (TYPE) | PLAS_TAB | Plan Folge-Vorgangszuordnung: Archivierte Objekte | 20010926 | |||
| 3 | PLFL_ARCH_TAB | Value transfer | Type reference (TYPE) | PLFL_TAB | Planfolge: Archivierte Sätze | 20010926 | |||
| 4 | PLKO_ARCH_TAB | Value transfer | Type reference (TYPE) | PLKO_TAB | Plankopf: Archivierte Sätze | 20010926 | |||
| 5 | PLPO_ARCH_TAB | Value transfer | Type reference (TYPE) | PLPO_TAB | Plan Vorgang, Phase, Untervorgang: Archivierte Objekte | 20010926 | |||
| 6 | PROTOCOL_TAB | Value transfer | Type reference (TYPE) | BALMI_TAB | EHS: Anwendungs-Log; Schnittstelle für APPL_LOG_WRITE_MESSAG | 20010926 | |||
| 7 | SEL_COMMENTS_ARCHIVE | Value transfer | Type reference (TYPE) | ADMI_RUN-COMMENTS | SPACE | Vermerk für einen Archivierungslauf | 20010926 | ||
| 8 | SEL_DATUV_DEL | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab zum Löschen | 20010926 | ||
| 9 | SEL_FLAG_DATUV_DEL | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Objekte ab Stichtag löschen | 20010926 | ||
| 10 | SEL_FLG_ALL_ARCHIVE | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = Gesamte Plangruppe archivieren | 20010926 | ||
| 11 | SEL_FLG_ALL_DEL | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Vollständige Objekte löschen | 20010926 | ||
| 12 | SEL_FLG_ONLINE_DEL | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = Nur online gelöschte Objekte löschen | 20010926 | ||
| 13 | SEL_FLG_PROTOCOL | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = mit Protokoll | 20010926 | ||
| 14 | SEL_FLG_TEST_ARCHIVE | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = Testlauf | 20010926 | ||
| 15 | SEL_FLG_TEST_CREATE_ARCHIVE | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = Archiv auch beim Testlauf | 20010926 | ||
| 16 | SEL_FLG_USAGE_CHECK | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Planverwendung prüfen | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 | ||
| 2 | Löschen nicht möglich | 20010926 |
Method REORG_DELETE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | PLAS_DEL_TAB | Value transfer | Type reference (TYPE) | PLAS_TAB | Plan Folge-Vorgangszuordnung: Gelöschte Objekte | 20010926 | |||
| 2 | PLFL_DEL_TAB | Value transfer | Type reference (TYPE) | PLFL_TAB | Planfolge: Gelöschte Sätze | 20010926 | |||
| 3 | PLKO_DEL_TAB | Value transfer | Type reference (TYPE) | PLKO_TAB | Plankopf: Gelöschte Sätze | 20010926 | |||
| 4 | PLPO_DEL_TAB | Value transfer | Type reference (TYPE) | PLPO_TAB | Plan Vorgang, Phase, Untervorgang: Gelöschte Objekte | 20010926 | |||
| 5 | PROTOCOL_TAB | Value transfer | Type reference (TYPE) | BALMI_TAB | EHS: Anwendungs-Log; Schnittstelle für APPL_LOG_WRITE_MESSAG | 20010926 | |||
| 6 | SEL_DATUV_DEL | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab zum Löschen | 20010926 | ||
| 7 | SEL_FLG_ALL_DEL | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Vollständige Objekte löschen | 20010926 | ||
| 8 | SEL_FLG_ONLINE_DEL | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = Nur online gelöschte Objekte löschen | 20010926 | ||
| 9 | SEL_FLG_PROTOCOL | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = mit Protokoll | 20010926 | ||
| 10 | SEL_FLG_USAGE_CHECK | Value transfer | Type reference (TYPE) | FLAG | SPACE | X = Planverwendung prüfen | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 | ||
| 2 | Löschen nicht möglich | 20010926 |
Method REPORT_PRINT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 2 | FLAG_PV | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = XSteps und PV ausgeben | 20010926 | ||
| 3 | FLAG_PVM | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = zusätzlich Merkmale ausgeben | 20010926 | ||
| 4 | FLAG_PVM_LTXT | Value transfer | Type reference (TYPE) | FLAG | 'X' | X = zusätzlich Langtext zu Merkmalen ausgeben | 20010926 | ||
| 5 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 6 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 7 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
Method SIMULATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 2 | FLG_OK | Value transfer | Type reference (TYPE) | FLAG | allgemeines flag | 20010926 | |||
| 3 | PHSEQ_TAB | Value transfer | Type reference (TYPE) | PHSEQ_TAB | Plan: Vorgang | 20010926 | |||
| 4 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 5 | PLNKN_TAB | Value transfer | Type reference (TYPE) | PLNKN_TAB | Plan: Vorgang | 20010926 | |||
| 6 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 7 | PLNTY | Call by reference | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
Method SIMULATE on Interface IF_EX_CPS_EXECUTION_D has no exception.
Method SYNTAX_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DATUV | Value transfer | Type reference (TYPE) | PLKO-DATUV | SY-DATLO | Datum gültig ab | 20010926 | ||
| 2 | FLG_OK | Value transfer | Type reference (TYPE) | FLAG | X = Syntaxprüfung OK | 20010926 | |||
| 3 | PHSEQ_TAB | Value transfer | Type reference (TYPE) | PHSEQ_TAB | Plan: Vorgang | 20010926 | |||
| 4 | PLNAL | Value transfer | Type reference (TYPE) | PLKO-PLNAL | Plangruppenzähler | 20010926 | |||
| 5 | PLNKN_TAB | Value transfer | Type reference (TYPE) | PLNKN_TAB | Plan: Vorgang | 20010926 | |||
| 6 | PLNNR | Value transfer | Type reference (TYPE) | PLKO-PLNNR | Schlüssel der Plangruppe | 20010926 | |||
| 7 | PLNTY | Value transfer | Type reference (TYPE) | PLKO-PLNTY | Plantyp | 20010926 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Methode nicht ausführbar | 20010926 |
History
| Last changed by/on | SAP | 20050219 |
| SAP Release Created in | 470 |