SAP ABAP Interface IF_EX_COM_CALL_IPC_MODULES (BAdI Interface IF_EX_COM_CALL_PME_MODULES)
Hierarchy
☛
SAP_ABA (Software Component) Cross-Application Component
⤷
AP-MD-PRO (Application Component) Central Part of Product Master
⤷
COM_PME_BRIDGE (Package) Interface Jave/ABAP for Product Modelling

⤷

⤷

Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_COM_CALL_IPC_MODULES | BAdI Class CL_EX_COM_CALL_IPC_MODULES | 20050623 |
Properties
Interface | IF_EX_COM_CALL_IPC_MODULES | |
Short Description | BAdI Interface IF_EX_COM_CALL_PME_MODULES |
General Data
Package | COM_PME_BRIDGE | Interface Jave/ABAP for Product Modelling |
Created | 20030811 | SAP |
Last changed | 20060208 | SAP |
Unicode checks active |
Forward declarations
Interface IF_EX_COM_CALL_IPC_MODULES has no forward declaration.
Interfaces
Interface IF_EX_COM_CALL_IPC_MODULES has no interface.
Friends
Interface IF_EX_COM_CALL_IPC_MODULES has no friend.
Attributes
Interface IF_EX_COM_CALL_IPC_MODULES has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Calls Module COM_CFG_CHECK_CONF_AND_SRV | 20030811 |
2 | ![]() |
Instance method | Public | Method | Calls Module COM_PME_SCE_FIND_KBS | 20030812 |
3 | ![]() |
Instance method | Public | Method | Calls Module COM_PME_SCE_GET_CLASS_CSTICS | 20030812 |
4 | ![]() |
Instance method | Public | Method | Calls Module COM_SCE_CONFIG_RESULT | 20030811 |
5 | ![]() |
Instance method | Public | Method | Calls Module COM_SCE_HAS_DATA | 20030811 |
6 | ![]() |
Instance method | Public | Method | Calls Module IPC_CREATE_CONFIG | 20030811 |
7 | ![]() |
Instance method | Public | Method | Calls Module IPC_GET_CONFIG_ITEM_INFO | 20030811 |
8 | ![]() |
Instance method | Public | Method | Calls Module IPC_GET_KNOWLEDGEBASE | 20030811 |
9 | ![]() |
Instance method | Public | Method | Calls Module IPC_INIT_CONFIG | 20030811 |
10 | ![]() |
Instance method | Public | Method | Calls Module IPC_SET_PROPERTY | 20030811 |
11 | ![]() |
Instance method | Public | Method | Calls Module IPC_SHOW_CONFIG | 20030811 |
Events
Interface IF_EX_COM_CALL_IPC_MODULES has no event.
Types
Interface IF_EX_COM_CALL_IPC_MODULES has no local type.
Method Signatures
Method COM_CFG_CHECK_CONF_AND_SRV Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_ACTIVE | Call by reference | Type reference (TYPE) | COMT_CFGD_FLAG_MD | 20030811 | |||
2 | ![]() |
IV_CLIENT | Call by reference | Type reference (TYPE) | MANDT | 20030811 |
Method COM_CFG_CHECK_CONF_AND_SRV on Interface IF_EX_COM_CALL_IPC_MODULES has no exception.
Method COM_PME_SCE_FIND_KBS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_KBS | Call by reference | Type reference (TYPE) | COMT_CFG_KB_HEADER_MD_TAB | 20030812 | |||
2 | ![]() |
IV_DATE | Value transfer | Type reference (TYPE) | COMT_SCE_KB_DATE_MD | 20030812 | |||
3 | ![]() |
IV_KB_USAGE | Value transfer | Type reference (TYPE) | CHAR32 | 20030812 | |||
4 | ![]() |
IV_ORG_ID | Value transfer | Type reference (TYPE) | COMT_CFGD_ORGID_MD | 20030812 | |||
5 | ![]() |
IV_ORG_TYPE | Value transfer | Type reference (TYPE) | CHAR10 | 20030812 | |||
6 | ![]() |
IV_PRODUCT_ID | Value transfer | Type reference (TYPE) | COMT_PRODUCT_ID | 20030812 | |||
7 | ![]() |
IV_PRODUCT_LOGSYS | Value transfer | Type reference (TYPE) | COMT_LOGSYS | 20030812 | |||
8 | ![]() |
IV_PRODUCT_TYPE | Value transfer | Type reference (TYPE) | COMT_PRODUCT_TYPE | 20030812 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20030812 | ||
2 | ![]() |
20030812 |
Method COM_PME_SCE_GET_CLASS_CSTICS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_CSTICS | Call by reference | Type reference (TYPE) | COMT_PME_CSTIC_TABLE | 20030812 | |||
2 | ![]() |
ET_CSTIC_DESCRS | Call by reference | Type reference (TYPE) | COMT_PME_CSTIC_DESCR_TABLE | 20030812 | |||
3 | ![]() |
ET_CSTIC_DOMAINS | Call by reference | Type reference (TYPE) | COMT_PME_CSTIC_DOMAIN | 20030812 | |||
4 | ![]() |
ET_CSTIC_VALUE_DESCRS | Call by reference | Type reference (TYPE) | COMT_PME_CSTIC_VALUE_DESCR_TAB | 20030812 | |||
5 | ![]() |
IV_DATE | Value transfer | Type reference (TYPE) | COMT_SCE_KB_DATE_MD | 20030812 | |||
6 | ![]() |
IV_KB_USAGE | Value transfer | Type reference (TYPE) | CHAR32 | 20030812 | |||
7 | ![]() |
IV_LANGUAGE | Value transfer | Type reference (TYPE) | LANGU | 20030812 | |||
8 | ![]() |
IV_ORG_ID | Value transfer | Type reference (TYPE) | COMT_CFGD_ORGID_MD | 20030812 | |||
9 | ![]() |
IV_ORG_TYPE | Value transfer | Type reference (TYPE) | CHAR10 | 20030812 | |||
10 | ![]() |
IV_PRODUCT_ID | Value transfer | Type reference (TYPE) | COMT_PRODUCT_ID | 20030812 | |||
11 | ![]() |
IV_PRODUCT_LOGSYS | Value transfer | Type reference (TYPE) | COMT_LOGSYS | 20030812 | |||
12 | ![]() |
IV_PRODUCT_TYPE | Value transfer | Type reference (TYPE) | COMT_PRODUCT_TYPE | 20030812 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Fehler im API | 20030812 | |
2 | ![]() |
Knowledge Base nicht gefunden | 20030812 | |
3 | ![]() |
Systemfehler | 20030812 |
Method COM_SCE_CONFIG_RESULT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_CFG | Call by reference | Type reference (TYPE) | COMT_CUCFG_TAB_MD | 20030811 | |||
2 | ![]() |
ET_INS | Call by reference | Type reference (TYPE) | COMT_CUINS_TAB_MD | 20030811 | |||
3 | ![]() |
ET_POS | Call by reference | Type reference (TYPE) | COMT_MAP_INST_POSGUID_MD_TAB | 20030811 | |||
4 | ![]() |
ET_PRT | Call by reference | Type reference (TYPE) | COMT_CUCFG_TAB_MD | 20030811 | |||
5 | ![]() |
ET_VAL | Call by reference | Type reference (TYPE) | COMT_CUVAL_MD_TAB | 20030811 | |||
6 | ![]() |
ET_VAR | Call by reference | Type reference (TYPE) | COMT_CUVAR_MD_TAB | 20030811 | |||
7 | ![]() |
ET_VK | Call by reference | Type reference (TYPE) | COMT_CUVK_MD_TAB | 20030811 | |||
8 | ![]() |
EV_GUID | Call by reference | Type reference (TYPE) | COMT_SCE_GUID_MD | 20030811 | |||
9 | ![]() |
EV_RESULT_PRODUCT_ID | Call by reference | Type reference (TYPE) | COMT_SCE_PRODUCT_ID_MD | 20030811 | |||
10 | ![]() |
EV_RESULT_PRODUCT_LOGSYS | Call by reference | Type reference (TYPE) | COMT_LOGSYS | 20030811 | |||
11 | ![]() |
EV_RESULT_PRODUCT_TYPE | Call by reference | Type reference (TYPE) | COMT_PRODUCT_TYPE | 20030811 | |||
12 | ![]() |
EV_RETCODE | Call by reference | Type reference (TYPE) | SY-SUBRC | 20030811 |
Method COM_SCE_CONFIG_RESULT on Interface IF_EX_COM_CALL_IPC_MODULES has no exception.
Method COM_SCE_HAS_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_DATA | Call by reference | Type reference (TYPE) | COMT_BOOLEAN | 20030812 | |||
2 | ![]() |
EV_RETCODE | Call by reference | Type reference (TYPE) | SY-SUBRC | 20030812 |
Method COM_SCE_HAS_DATA on Interface IF_EX_COM_CALL_IPC_MODULES has no exception.
Method IPC_CREATE_CONFIG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_CONFIG_ID | Call by reference | Type reference (TYPE) | COMT_IPC_CONFIG_ID_MD | 20030812 | |||
2 | ![]() |
IT_CFG | Call by reference | Type reference (TYPE) | COMT_CUCFG_MD_TAB | 20030812 | |||
3 | ![]() |
IT_CONTEXT | Call by reference | Type reference (TYPE) | COMT_SCE_CONFIG_CONTEXT_MD_TAB | 20030812 | |||
4 | ![]() |
IT_INS | Call by reference | Type reference (TYPE) | COMT_CUINS_MD_TAB | 20030812 | |||
5 | ![]() |
IT_PRT | Call by reference | Type reference (TYPE) | COMT_CUPRT_MD_TAB | 20030812 | |||
6 | ![]() |
IT_VAL | Call by reference | Type reference (TYPE) | COMT_CUVAL_MD_TAB | 20030812 | |||
7 | ![]() |
IT_VK | Call by reference | Type reference (TYPE) | COMT_CUVK_MD_TAB | 20030812 | |||
8 | ![]() |
IV_HANDLE | Call by reference | Type reference (TYPE) | COMT_IPC_SESSION_HANDLE_MD | 20050627 | |||
9 | ![]() |
IV_KB_DATE | Call by reference | Type reference (TYPE) | COMT_IPC_KB_DATE_MD | 20030812 | |||
10 | ![]() |
IV_KB_DISTRIB_CHANNEL | Call by reference | Type reference (TYPE) | COMT_IPC_KB_DISTRIB_CHANNEL_MD | 20030812 | |||
11 | ![]() |
IV_KB_ID | Call by reference | Type reference (TYPE) | COMT_CFGD_KBID_MD | 20030812 | |||
12 | ![]() |
IV_KB_LOGSYS | Call by reference | Type reference (TYPE) | COMT_LOGSYS | 20030812 | |||
13 | ![]() |
IV_KB_NAME | Call by reference | Type reference (TYPE) | COMT_IPC_KB_NAME_MD | 20030812 | |||
14 | ![]() |
IV_KB_PROFILE | Call by reference | Type reference (TYPE) | COMT_IPC_KB_PROFILE_MD | 20030812 | |||
15 | ![]() |
IV_KB_SALES_ORG | Call by reference | Type reference (TYPE) | COMT_IPC_KB_SALES_ORG_MD | 20030812 | |||
16 | ![]() |
IV_KB_VERSION | Call by reference | Type reference (TYPE) | COMT_IPC_KB_VERSION_MD | 20030812 | |||
17 | ![]() |
IV_LANGUAGE | Call by reference | Type reference (TYPE) | CHAR2 | 20030812 | |||
18 | ![]() |
IV_OBJECT_ID | Call by reference | Type reference (TYPE) | COMT_IPC_OBJECT_ID_MD | 20030812 | |||
19 | ![]() |
IV_OBJECT_LOGSYS | Call by reference | Type reference (TYPE) | LOGSYS | 20030812 | |||
20 | ![]() |
IV_OBJECT_TYPE | Call by reference | Type reference (TYPE) | COMT_IPC_OBJECT_TYPE_MD | 20030812 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Fehler am IPC Kommando aufgetreten | 20030812 | |
2 | ![]() |
Interner Fehler aufgetreten | 20030812 |
Method IPC_GET_CONFIG_ITEM_INFO Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ET_CFG | Call by reference | Type reference (TYPE) | COMT_CUCFG_MD_TAB | 20030812 | |||
2 | ![]() |
ET_INS | Call by reference | Type reference (TYPE) | COMT_CUINS_MD_TAB | 20030812 | |||
3 | ![]() |
ET_POS | Call by reference | Type reference (TYPE) | COMT_MAP_INST_POSGUID_MD_TAB | 20030812 | |||
4 | ![]() |
ET_PRT | Call by reference | Type reference (TYPE) | COMT_CUPRT_MD_TAB | 20030812 | |||
5 | ![]() |
ET_VAL | Call by reference | Type reference (TYPE) | COMT_CUVAL_MD_TAB | 20030812 | |||
6 | ![]() |
ET_VAR | Call by reference | Type reference (TYPE) | COMT_CUVAR_MD_TAB | 20030812 | |||
7 | ![]() |
ET_VK | Call by reference | Type reference (TYPE) | COMT_CUVK_MD_TAB | 20030812 | |||
8 | ![]() |
EV_RESULT_OBJECT_GUID | Call by reference | Type reference (TYPE) | COMT_IPC_GUID_EXTERN_MD | 20030812 | |||
9 | ![]() |
EV_RESULT_OBJECT_ID | Call by reference | Type reference (TYPE) | COMT_IPC_OBJECT_ID_MD | 20030812 | |||
10 | ![]() |
EV_RESULT_OBJECT_LOGSYS | Call by reference | Type reference (TYPE) | LOGSYS | 20030812 | |||
11 | ![]() |
EV_RESULT_OBJECT_TYPE | Call by reference | Type reference (TYPE) | COMT_IPC_OBJECT_TYPE_MD | 20030812 | |||
12 | ![]() |
IV_CONFIG_ID | Call by reference | Type reference (TYPE) | COMT_IPC_CONFIG_ID_MD | 20030812 | |||
13 | ![]() |
IV_ENABLE_AUTOMATIC_SEARCH | Call by reference | Type reference (TYPE) | COMT_BOOLEAN | 20030812 | |||
14 | ![]() |
IV_HANDLE | Call by reference | Type reference (TYPE) | COMT_IPC_SESSION_HANDLE_MD | 20050627 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Fehler am IPC Kommando aufgetreten | 20030812 | |
2 | ![]() |
Interner Fehler aufgetreten | 20030812 |
Method IPC_GET_KNOWLEDGEBASE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_KB_UINAME | Call by reference | Type reference (TYPE) | COMT_CFGD_UINAME_MD | 20030812 | |||
2 | ![]() |
IV_HANDLE | Call by reference | Type reference (TYPE) | COMT_IPC_SESSION_HANDLE_MD | 20050627 | |||
3 | ![]() |
IV_KB_ID | Call by reference | Type reference (TYPE) | COMT_CFGD_KBID_MD | 20030812 | |||
4 | ![]() |
IV_KB_LOGSYS | Call by reference | Type reference (TYPE) | COMT_IPC_KB_LOGSYS_MD | 20030812 | |||
5 | ![]() |
IV_KB_NAME | Call by reference | Type reference (TYPE) | COMT_IPC_KB_NAME_MD | 20030812 | |||
6 | ![]() |
IV_KB_PROFILE | Call by reference | Type reference (TYPE) | COMT_IPC_KB_PROFILE_MD | 20030812 | |||
7 | ![]() |
IV_KB_VERSION | Call by reference | Type reference (TYPE) | COMT_IPC_KB_VERSION_MD | 20030812 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20030812 | ||
2 | ![]() |
20030812 |
Method IPC_INIT_CONFIG Signature
Method IPC_INIT_CONFIG on Interface IF_EX_COM_CALL_IPC_MODULES has no parameter.
Method IPC_INIT_CONFIG on Interface IF_EX_COM_CALL_IPC_MODULES has no exception.
Method IPC_SET_PROPERTY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_PROPERTY | Value transfer | Type reference (TYPE) | COMC_IPC_PROP_MD | 20030812 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20030812 | ||
2 | ![]() |
20030812 | ||
3 | ![]() |
20030812 |
Method IPC_SHOW_CONFIG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_CALLER | Call by reference | Type reference (TYPE) | COMT_IPC_COMPONENT_MD | 20030812 | |||
2 | ![]() |
IV_CONFIG_ID | Call by reference | Type reference (TYPE) | COMT_IPC_CONFIG_ID_MD | 20030812 | |||
3 | ![]() |
IV_DISPLAY | Call by reference | Type reference (TYPE) | COMT_BOOLEAN | 20030812 | |||
4 | ![]() |
IV_HANDLE | Call by reference | Type reference (TYPE) | I | 20050627 | |||
5 | ![]() |
IV_INITIALIZE_HTML | Call by reference | Type reference (TYPE) | XFELD | SPACE | Feld zum Ankreuzen | 20040908 | |
6 | ![]() |
IV_KB_UINAME | Call by reference | Type reference (TYPE) | COMT_CFGD_UINAME_MD | 20030812 | |||
7 | ![]() |
IV_LANGUAGE | Call by reference | Type reference (TYPE) | COMT_SCE_LANGUAGE_MD | 20030812 | |||
8 | ![]() |
IV_SCENARIO | Call by reference | Type reference (TYPE) | COMT_IPC_COMPONENT_MD | 20030812 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Programminternes Problem aufgetreten | 20030812 | |
2 | ![]() |
Keine registrierte Session gefunden | 20030812 |
History
Last changed by/on | SAP | 20060208 |
SAP Release Created in | 400 |