SAP ABAP Interface IF_EX_BADI_EAM_TZ_IEL2_CORE (Interface for BAdI: BADI_EAM_TZ_IEL2_CORE)
Hierarchy
SAP_APPL (Software Component) Logistics and Accounting
   PM (Application Component) Plant Maintenance
     PM_TZ_CORE (Package) Time Zone Support SAP_APPL Layer
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_EX_ES_IEL2_TZ_CORE_IMPL Class for BAdI Impl.: BADI_EAM_TZ_SFWS_IEL2_TZ_CORE 20090209
Properties
Interface IF_EX_BADI_EAM_TZ_IEL2_CORE  
Short Description Interface for BAdI: BADI_EAM_TZ_IEL2_CORE    
General Data
Package PM_TZ_CORE   Time Zone Support SAP_APPL Layer 
Created 20090209   SAP 
Last changed 20100310   SAP 
Unicode checks active    
Forward declarations
Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no forward declaration.
Interfaces
# Interface Abstract Final Description Created on
1 IF_BADI_INTERFACE Tag Interface for BAdIs 20090209
Friends
Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no friend.
Attributes
Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CONVERT_EQUI_GEN_SESS2SYS Instance method Public Method Generic method to convert time date of equipment 20090211
2 CONVERT_EQUI_GEN_SYS2SESS Instance method Public Method Generic method to convert time date of equipment 20090211
3 CONVERT_EQUI_MSGCHECK_SESS2SYS Instance method Public Method Convert Equipment in FUBA Date_check_for_equi_location 20090223
4 CONVERT_IEQI_INSTALL_SESS2SYS Instance method Public Method Converts equipment Installation/dismantling popup to system 20090209
5 CONVERT_IEQI_INSTALL_SYS2SESS Instance method Public Method Converts equipment Installation/dismantling popup to session 20090209
6 CONVERT_IEQI_SESS2SYSTEM Instance method Public Method Converts equipment object time/date 20090209
7 CONVERT_IEQI_SYS2SESS Instance method Public Method Changes equipment object time/date 20090210
8 CONVERT_REPLACE_EQUI_SESS2SYS Instance method Public Method Changes date/time on replace equi popup to system time 20090211
9 CONVERT_REPLACE_EQUI_SYS2SESS Instance method Public Method Changes date/time on replace equi popup to session time 20090211
10 CONVERT_SEQUI_CHECK_SYS2SESS Instance method Public Method Converts EQUI date valid from 20090210
11 IS_ACTIVE Instance method Public Method Returns if the customizing entry is active 20090209
12 SET_EQUI_SUB_FLAG Instance method Public Method Sets the flag used in IEQI_SINGLE2SESS 20090210
13 SET_IEQI_REPLACE_FLAG Instance method Public Method Sets the ieqi replace flag 20090212
Events
Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no event.
Types
Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no local type.
Method Signatures

Method CONVERT_EQUI_GEN_SESS2SYS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) DATBI Valid To Date 20090211
2 Changing CV_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090211

Method CONVERT_EQUI_GEN_SESS2SYS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_EQUI_GEN_SYS2SESS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090211
2 Changing CV_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090211

Method CONVERT_EQUI_GEN_SYS2SESS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_EQUI_MSGCHECK_SESS2SYS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090223
2 Changing CV_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090223

Method CONVERT_EQUI_MSGCHECK_SESS2SYS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_IEQI_INSTALL_SESS2SYS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_EQUI_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090209
2 Changing CV_EQUI_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090209
3 Changing CV_H_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090209
4 Changing CV_H_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090209

Method CONVERT_IEQI_INSTALL_SESS2SYS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_IEQI_INSTALL_SYS2SESS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_EQUI_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090209
2 Changing CV_EQUI_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090209
3 Changing CV_H_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090209
4 Changing CV_H_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090209

Method CONVERT_IEQI_INSTALL_SYS2SESS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_IEQI_SESS2SYSTEM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) DATAB Valid-From Date 20090209
2 Changing CV_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090209

Method CONVERT_IEQI_SESS2SYSTEM on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_IEQI_SYS2SESS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) IEQINSTALL-DATUM Date on which installation location of equipment was changed 20090210
2 Changing CV_TIME Call by reference Type reference (TYPE) IEQINSTALL-UZEIT Time at which the InstallLoc of the equipment was changed 20090210

Method CONVERT_IEQI_SYS2SESS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_REPLACE_EQUI_SESS2SYS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) DATBI Valid-From Date 20090211
2 Changing CV_TIME Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090211

Method CONVERT_REPLACE_EQUI_SESS2SYS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_REPLACE_EQUI_SYS2SESS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATE Call by reference Type reference (TYPE) DATBI Valid To Date 20090211
2 Changing CV_TIME Call by reference Type reference (TYPE) TIMBI Valid-From Date 20090211

Method CONVERT_REPLACE_EQUI_SYS2SESS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method CONVERT_SEQUI_CHECK_SYS2SESS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_DATAB Call by reference Type reference (TYPE) DATAB Valid-From Date 20090210
2 Exporting EV_TIMBI Call by reference Type reference (TYPE) TIMBI Equipment usage period time stamp 20090326
3 Importing IV_EQLFN Call by reference Type reference (TYPE) EQUZ-EQLFN Consecutive numbering of EquipUsagePeriods on same day 20090210
4 Importing IV_EQUNR Call by reference Type reference (TYPE) EQUNR Equipment Number 20090210
5 Importing IV_EQUZN Call by reference Type reference (TYPE) EQUZ-EQUZN Number of next EquipUsagePeriod on same day 20090210

Method CONVERT_SEQUI_CHECK_SYS2SESS on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method IS_ACTIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting RV_TIME_ZONE_ACTIVE Call by reference Type reference (TYPE) FLAG General Flag 20090209

Method IS_ACTIVE on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method SET_EQUI_SUB_FLAG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_EQUI_SUB_FLAG Call by reference Type reference (TYPE) FLAG General Flag 20090210

Method SET_EQUI_SUB_FLAG on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.

Method SET_IEQI_REPLACE_FLAG Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_FLAG Call by reference Type reference (TYPE) FLAG General Flag 20090212

Method SET_IEQI_REPLACE_FLAG on Interface IF_EX_BADI_EAM_TZ_IEL2_CORE has no exception.
History
Last changed by/on SAP  20100310 
SAP Release Created in 605