SAP ABAP Interface DFPS_IF_LM_INT_LBK (Interface for BAdI: DFPS_BADI_LM_INT_LBK)
Hierarchy
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
   PM (Application Component) Plant Maintenance
     DFPS_PM_EA_APPL (Package) Decoupling ALM - DFPS
Properties
Interface DFPS_IF_LM_INT_LBK  
Short Description Interface for BAdI: DFPS_BADI_LM_INT_LBK    
General Data
Package DFPS_PM_EA_APPL   Decoupling ALM - DFPS 
Created 20061013   SAP 
Last changed 20100310   SAP 
Unicode checks active    
Forward declarations
Interface DFPS_IF_LM_INT_LBK has no forward declaration.
Interfaces
# Interface Abstract Final Description Created on
1 IF_BADI_INTERFACE Tag Interface for BAdIs 20061016
Friends
Interface DFPS_IF_LM_INT_LBK has no friend.
Attributes
Interface DFPS_IF_LM_INT_LBK has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CALL_CUS Instance method Public Method Call Controlled Usage Rate 20061016
2 CALL_EVM Instance method Public Method Call Event Monitor 20061016
3 CALL_FLIGHT Instance method Public Method Call Flight 20061016
4 CALL_FLIGHT_PLAN Instance method Public Method Call Flight Plan 20061016
5 CALL_STB Instance method Public Method Call Status Board 20061016
6 CALL_TST Instance method Public Method Call Technical Status List 20061016
7 DFPS_GET_KEY Instance method Public Method Call DFPS Basic Settings 20061016
8 GET_STATUS_ICON Instance method Public Method Determine Status Icons, Taking Priority into Account 20070725
9 IS_MASTER_EQUIPMENT Instance method Public Method Check Whether Equipment is Master Equipment 20061016
10 MASTER_EQUI_SET_OKCODE Instance method Public Method Set OK Code for Master Equipment Screen 20061016
Events
Interface DFPS_IF_LM_INT_LBK has no event.
Types
Interface DFPS_IF_LM_INT_LBK has no local type.
Method Signatures

Method CALL_CUS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_EQUNR Call by reference Type reference (TYPE) DFPS_TB_LM_EQUNR Tabelle mit Equipmentnummern 20061016
2 Importing IT_TPLNR Call by reference Type reference (TYPE) DFPS_TB_LM_TPLNR Tabelle mit Technischen-Platz-Nummern 20061016
3 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20061016
4 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20061016

Method CALL_CUS on Interface DFPS_IF_LM_INT_LBK has no exception.

Method CALL_EVM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_EQUNR Call by reference Type reference (TYPE) DFPS_TB_LM_EQUNR Tabelle mit Equipmentnummern 20061016
2 Importing IT_TPLNR Call by reference Type reference (TYPE) DFPS_TB_LM_TPLNR Tabelle mit Technischen-Platz-Nummern 20061016
3 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20061016
4 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20061016

Method CALL_EVM on Interface DFPS_IF_LM_INT_LBK has no exception.

Method CALL_FLIGHT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AUFNR Call by reference Type reference (TYPE) AUFNR Auftragsnummer 20061016
2 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20061016
3 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20061016

Method CALL_FLIGHT on Interface DFPS_IF_LM_INT_LBK has no exception.

Method CALL_FLIGHT_PLAN Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_EQUNR Call by reference Type reference (TYPE) DFPS_TB_LM_EQUNR Tabelle mit Equipmentnummern 20061016
2 Importing IT_TPLNR Call by reference Type reference (TYPE) DFPS_TB_LM_TPLNR Tabelle mit Technischen-Platz-Nummern 20061016
3 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20061016
4 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20061016

Method CALL_FLIGHT_PLAN on Interface DFPS_IF_LM_INT_LBK has no exception.

Method CALL_STB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_EQUNR Call by reference Type reference (TYPE) DFPS_TB_LM_EQUNR Tabelle mit Equipmentnummern 20061016
2 Importing IT_TPLNR Call by reference Type reference (TYPE) DFPS_TB_LM_TPLNR Tabelle mit Technischen-Platz-Nummern 20061016
3 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20061016
4 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20061016

Method CALL_STB on Interface DFPS_IF_LM_INT_LBK has no exception.

Method CALL_TST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_EQUNR Call by reference Type reference (TYPE) DFPS_TB_LM_EQUNR Tabelle mit Equipmentnummern 20061016
2 Importing IT_TPLNR Call by reference Type reference (TYPE) DFPS_TB_LM_TPLNR Tabelle mit Technischen-Platz-Nummern 20061016
3 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Equipmentnummer 20061016
4 Importing I_TPLNR Call by reference Type reference (TYPE) TPLNR Technischer Platz 20061016

Method CALL_TST on Interface DFPS_IF_LM_INT_LBK has no exception.

Method DFPS_GET_KEY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_DFPS_VALUE Call by reference Type reference (TYPE) CHAR255 char255 20061016
2 Importing I_DFPS_KEY Call by reference Type reference (TYPE) CHAR15 Char 15 20061016
# Exception Resumable Description Created on
1 INITIAL_KEY Initialer Schlüsselwert 20061016
2 INVALID_KEY Ungültiger Schlüsselwert 20061016
3 NO_KEY_TEXT Keine Schlüsselbeschreibung gepflegt 20061016
4 UNKNOWN_ERROR Unbekannter Fehler 20061016

Method GET_STATUS_ICON Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_ICON Call by reference Type reference (TYPE) ICON_D Ikone in Textfeldern (Ersatzdarstellung, Alias) 20070725
2 Exporting E_ICON_NAME Call by reference Type reference (TYPE) ICONNAME Name einer Ikone 20070725
3 Exporting E_ICON_TEXT Call by reference Type reference (TYPE) ICON_TEXT Trägerfeld für Ikonen 20070725
4 Importing IT_ESTAT Call by reference Type reference (TYPE) DFPS_TB_LM_ESTAT Anwenderstatus Tabelle 20070725
5 Importing I_BYPASS_BUFFER Call by reference Type reference (TYPE) XFELD Feld zum Ankreuzen 20070725
6 Importing I_OBJNR Call by reference Type reference (TYPE) J_OBJNR Objektnummer 20070725
7 Importing I_STSMA Call by reference Type reference (TYPE) J_STSMA Statusschema 20070725

Method GET_STATUS_ICON on Interface DFPS_IF_LM_INT_LBK has no exception.

Method IS_MASTER_EQUIPMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_IS_MASTER_EQUI Call by reference Type reference (TYPE) XFELD char255 20061016
2 Importing I_EQUNR Call by reference Type reference (TYPE) EQUNR Char 15 20061016

Method IS_MASTER_EQUIPMENT on Interface DFPS_IF_LM_INT_LBK has no exception.

Method MASTER_EQUI_SET_OKCODE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_ITOB Call by reference Type reference (TYPE) ITOB Generierte Tabelle zu einem View 20061016
2 Importing I_OK_CODE Call by reference Type reference (TYPE) SYUCOMM Funktionscode, der PAI ausgelöst hat 20061016

Method MASTER_EQUI_SET_OKCODE on Interface DFPS_IF_LM_INT_LBK has no exception.
History
Last changed by/on SAP  20100310 
SAP Release Created in