SAP ABAP Function Module CBIH_LB61_MP_SINGLE_READ (EHS: Lesen eines einzelnen Messprojektes (alle Daten))
Hierarchy
☛
EA-APPL (Software Component) SAP Enterprise Extension PLM, SCM, Financials
⤷
EHS-IHS (Application Component) Industrial Hygiene and Safety
⤷
CBIH (Package) EH&S: Industrial Hygiene and Safety

⤷

⤷

Basic Data
Function Module | CBIH_LB61_MP_SINGLE_READ | EHS: Lesen eines einzelnen Messprojektes (alle Daten) |
Function Group | CBIH_LB61 | EHS: Library - Measurement Project |
Program Name | SAPLCBIH_LB61 | |
INCLUDE Name | LCBIH_LB61U22 |
Parameters
Type | Parameter Name | Typing | Associated Type | Default value | Optional | Pass Value | Short text |
---|---|---|---|---|---|---|---|
![]() |
E_MPIOT | TYPE | CCIHS_MPIOT | Measurement Project Header | |||
![]() |
E_ACTYPE | TYPE | RCGDIALCTR-ACTYPE | Activity Type | |||
![]() |
I_RECN | TYPE | CCIHS_MPIOT-RECN | Measurement Project Key | |||
![]() |
I_ACTYPE | TYPE | RCGDIALCTR-ACTYPE | Activity Type | |||
![]() |
I_ADDINF | TYPE | RCGADDINF | Additional Information | |||
![]() |
I_FLG_AUTHORITY_CHECK | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Berechtigungsprüfung | ||
![]() |
I_FLG_WITH_LOCK | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Sperren setzen | ||
![]() |
I_FLG_WITH_MESSAGE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Fehlermeldungen im Dialog anzeigen | ||
![]() |
I_FLG_MP1_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messprojekt - Beurteilung | ||
![]() |
I_FLG_MP2_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messprojekt - Bemerkung | ||
![]() |
I_FLG_IHVA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Bewertungsinstanzen | ||
![]() |
I_FLG_DVLIST | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Geräteliste | ||
![]() |
I_FLG_MPWA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Arbeitsbereich | ||
![]() |
I_FLG_MPWA_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Arbeitsbereich - Langtext | ||
![]() |
I_FLG_MPPL | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messplan | ||
![]() |
I_FLG_MPPL_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messplan - Langtext | ||
![]() |
I_FLG_MJHEAD | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messung | ||
![]() |
I_FLG_MJ1_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messung - Langtext 1 | ||
![]() |
I_FLG_MJ2_LTXT | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messung - Langtext 2 | ||
![]() |
I_FLG_MJ_IHVA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Bewertungsinstanzen Messung | ||
![]() |
I_FLG_MJVALUE | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messung - Messwerte | ||
![]() |
I_FLG_MJWA | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messung - Arbeitsbereich | ||
![]() |
I_FLG_MJ_PART | TYPE | ESP1_BOOLEAN | ESP1_FALSE | Kennz: Messung - Referenzmessungen | ||
![]() |
I_LANGU | TYPE | SYST-LANGU | SY-LANGU | Language Key of Current Text Environment | ||
![]() |
E_MP_LTXT1_IOTAB | TYPE | CCIHS_LONGTEXTAPI | Assessment | |||
![]() |
E_MP_LTXT2_IOTAB | TYPE | CCIHS_LONGTEXTAPI | Bemerkung | |||
![]() |
E_MPVAL_IOTAB | TYPE | CCIHS_IHVALIOT | Value Assignment Instances | |||
![]() |
E_MPPROP_IOTAB | TYPE | CIH01_IHPRAPI_TAB_TYPE | Characteristics Data | |||
![]() |
E_MPWA_IOTAB | TYPE | CCIHS_MPWAIOT | Assigned work areas | |||
![]() |
E_MPWA_LTXT_IOTAB | TYPE | CCIHS_LONGTEXTAPI | Arbeitsbereiche - Langtext | |||
![]() |
E_DVLIST_IOTAB | TYPE | CCIHS_MPDVIOT | Device List | |||
![]() |
E_MPPL_SUB_IOTAB | TYPE | CCIHS_MPPLIOT | Measurement Plan - Agents | |||
![]() |
E_MPPL_MET_IOTAB | TYPE | CCIHS_MPMTIOT | Measurement Plan - Measurement Method | |||
![]() |
E_MPPL_LTXT_IOTAB | TYPE | CCIHS_LONGTEXTAPI | Messplan - Langtext | |||
![]() |
E_MJ_IOTAB | TYPE | CCIHS_MJIOT | Measurements | |||
![]() |
E_MJ_LTXT1_IOTAB | TYPE | CCIHS_LONGTEXTAPI | Messungen - Langtext 1 | |||
![]() |
E_MJ_LTXT2_IOTAB | TYPE | CCIHS_LONGTEXTAPI | Messungen - Langtext 2 | |||
![]() |
E_MJ_IHVA_IOTAB | TYPE | CCIHS_IHVALIOT | Messung - Bewertungsinstanzen | |||
![]() |
E_MJ_PROP_IOTAB | TYPE | CIH01_IHPRAPI_TAB_TYPE | Messung - Merkmalsdaten | |||
![]() |
E_MJ_VALUE_IOTAB | TYPE | CCIHS_MJVAIOT | Measurements - Measured Values | |||
![]() |
E_MJ_PART_IOTAB | TYPE | CCIHS_RFMJIOT | Measurements - Reference Measurements | |||
![]() |
E_MJ_WAH_IOTAB | TYPE | CCIHS_MJWAIOT | Measurements - Work Areas | |||
![]() |
MP_NOT_FOUND | TYPE | Messprojekt nicht gefunden | ||||
![]() |
NO_AUTHORITY | TYPE | No Authorization | ||||
Processing Type
Normal Function Module | |
![]() |
BaseXML supported |
Update Module | Start immediately |
Immediate Start, No Restart | |
Start Delayed | |
Coll.run | |
JAVA Module Callable from ABAP | |
Remote-Enabled JAVA Module | |
Module Callable from JAVA |
History
Last changed by/on | SAP | 20030327 |
SAP Release Created in |