Hierarchy
⤷
⤷
⤷
Basic Data
| Data Element | VVHKVOTYP |
| Short Description | Calculation type of heating cost formula |
Data Type
| Category of Dictionary Type | D | Domain |
| Type of Object Referenced | No Information | |
| Domain / Name of Reference Type | VVHKVOTYP | |
| Data Type | CHAR | Character String |
| Length | 1 | |
| Decimal Places | 0 | |
| Output Length | 1 | |
| Value Table |
Further Characteristics
| Search Help: Name | ||
| Search Help: Parameters | ||
| Parameter ID | ||
| Default Component name | CALC_TYPE_HEAT_CST_FORMULA | |
| Change document | ||
| No Input History | ||
| Basic direction is set to LTR | ||
| No BIDI Filtering |
Field Label
| Length | Field Label | |
| Short | 10 | Type HCDis |
| Medium | 19 | Type of HC distr. |
| Long | 39 | Calc. type of heating cost formula |
| Heading | 39 | Calc. type of heating cost formula |
Documentation
Definition
The percentage share of hot water consumption HW% is calculated in three different ways (B,W,F).
B = Calculation of fuel consumption
HW% = B / W
Where W = Tot.Cons. / Hu and B = (2.5 * V * (tw - 10)) / HV
W = Calculation of heating amount
HW% = Q / Tot.Cons.
Where Q = 2.0 * V * (TW - 10)
F = Fixed flat rate for hot water consumption
Experience has shown that 18% is an appropriate figure to use as the flat rate amount for hot water consumption.
List of abbreviations:
C = Measured volume of consumed hot water in m3
TW = Measured or estimated average hot water temperature
HV = Heating value of consumed fuel in KwH/l or other unit
B = Fuel consumption in unit of measurement used for HV
Tot.Cons. = Total consumed heating amount as input value
W = Total heating amount to be determined
Q = Heating amount of the hot water consumption
All data according to §9 of the German heating expenses regulations.
History
| Last changed by/on | SAP | 20110901 |
| SAP Release Created in |