Hierarchy
⤷ RE-FX-BD (Application Component) Basic Data
⤷ RE_BD_AO (Package) RE: Arch. Object (Master Data of Architectural Object)
Basic Data
Data Element | REBDPARTLENGTHMAX |
Short Description | AOID Code: Maximum Length |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | REBDPARTLENGTH | |
Data Type | INT1 | 1-byte integer, integer number <= 255 |
Length | 3 | |
Decimal Places | 0 | |
Output Length | 3 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | PART_MAX_LENGTH | |
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | Max.length |
Medium | 15 | Maximum Length |
Long | 20 | Maximum Length |
Heading | 10 | Max.length |
Documentation
Definition
Specifies the maximum length of the AOID code that becomes part of the architectural object ID. If you enter a value here, then the code is not allowed to be longer than this value. If no value is entered here, then the system does not perform a check.
If the AOID code is automatically derived from the architectural object number, then the length entered as the default length is relevant. If no default length is entered, then the maximum length is applied instead.
Use
In Customizing, specify a maximum length for all object types for which an AOID code is used for generating the architectural object ID.
Dependencies
Example
The following was specified in the Customizing table for automatic assignment of the architectural object ID (AOID):
Name of AO Type Max.Length DefLength Use Separator From AONR
Locality 3 X
Bldg complex 13
Building 2 X - X
Part of building 1 X X
Floor 2 1 X . X
Room 3 2 X X
The system assigns the following architectural object IDs based on these object numbers and codes:
Name of Arch. Object Type
AO Number AOID Code Generated AOID
Locality WALLDORF WDF (manual) WDF
Bldg complex 1 COM1 (manual) WDFCOM1
Building 2 02 (automatic) WDF02
Part of building A A (automatic) WDF02-A
Floor 4 4 (automatic) WDF02-A4
Room 56 56 WDF02-A4.56
Explanation:
- Where the Use in Subordinate Objects indicator is set, the codes are used as part of the AOID in the next level.
- If a separator was specified, then this is added after the AOID of the object on the previous level. If the indicator is not set (in the example this applies to the building complex), then the code is only used for assigning the AOID of the current object itself (WDFCOM1 in the example).
- If the From AONR indicator is set, then the AOID code is derived from the number. In this case, the system uses the number of places specified in the DefLength field to create the AOID code. In doing so, the system starts from right to left, and adds leading zeros if needed. If there is no value specified for this Def.Length, the system uses the value in the Max.Length field instead.
History
Last changed by/on | SAP | 20031111 |
SAP Release Created in | 200 |