Basic Data
Data Element | QGESTICH |
Short Description | Sample Size |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | QMENGEPLOS | |
Data Type | QUAN | Quantity field, points to a unit field with format UNIT |
Length | 13 | |
Decimal Places | 3 | |
Output Length | 17 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | SAMPLE_SIZE | |
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | SampleSize |
Medium | 15 | Sample size |
Long | 20 | Sample size |
Heading | 13 | Sample size |
Documentation
Definition
Size of the entire sample, that is, the sum of all individual samples.
Dependencies
In the material master for each inspection type, you can define how the sample size is calculated.
There are two possibilities for determining the sample size:
- The sample size is entered by the user
If the sample size is to be entered manually during the inspection, you must set the indicators Manual sample entry and Trigger manually.
- The sample size is calculated automatically by the system
If the sample size is to be calculated automatically, a distinction must be made between the following two cases:
- Inspection without an inspection plan or material specification
- To calculate the sample size, you can:
- - Specify a sampling procedure
- - Set the indicator 100% inspection
- - Specify an Inspection percentage
- Inspection with an inspection plan or material specification
- The sample size is calculated on the basis of the sampling procedure defined at the characteristic level of the inspection plan or material specification.
- If a sampling procedure was not defined in the inspection plan or material specification, the system uses the predefined sampling procedure stored in Customizing at plant level to determine the sample size.
- If a sampling procedure is not specified in Customizing, the sample size for the characteristic is calculated as though the indicator for a 100% inspection was set in the material master for the inspection type.
If you set the indicator for a 100% inspection in the material master record, this has priority over all other procedures defined to calculate the inspection size.