Created on 19990816    
Customizing Attributes _ISUDMMR_000010   Define Tolerance Limits for Validation Classes 
Customizing Activity _ISUDMMR_000010   Define Tolerance Limits for Validation Classes 
Document
Document Class SIMG   Hypertext: Object Class - Class to which a document belongs.
Document Name _ISUDMMR_000010    

In this IMG activity, you define tolerance limits for the following independent validations allocated to a validation class:

Tolerance limits are defined in relation to consumption limits.

The system determines tolerance limits automatically via the expected consumption and the period duration according to the settings established above. The limits are displayed during Entry and correction of MR results and Monitoring of MR results. If the meter reading result exceeds or falls below these tolerance limits, it becomes implausible.

Example

VCls | Valid-from consump. |I| EC | %PD. | %NDv.| Pos. dev.|Neg. dev.
-----------------------------------------------------------------------

0001 |0 |1| 1 |70 |40 | |

0001 |100 |1| 1 |60 |30 | |

0001 |100 |2| 2 |65 |35 | |

0001 |1000 |1| 2 |50 |20 | |

0002 |0 |1| 1 | | |200 |100

0002 |5000 |1| 2 | | |400 |300


  • Results from registers with validation class 0001 have an upper limit of 70% and a lower limit of 40% within the range of 0 to 99 kwh. If these limits are exceeded, a warning is displayed (EC = 1).
    If consumption is between 100 to 999 kwh, a warning is displayed whenthe upper limit of 60 % or the lower limit 30 % is exceeded.
    A second interval (I = 2) was defined for the same consumption range. If the upper limit of 65 % and the lower limit of 35 % is exceeded, an error message is displayed instead of a warning (EC = 2). The meter reading result is automatically deferred for later processing if tolerance limits are exceeded.
  • Absolute deviations have been defined for validation class 0002. An error or warning message is displayed if tolerance limits exceeded. You can also combine perentage and absolute deviations.

Requirements

Standard settings

Recommendation

Activities

  1. Choose New entries.
  2. Define tolerance limits for each validation class for independent validations.

Further notes

Business Attributes
ASAP Roadmap ID 204   Establish Functions and Processes 
Mandatory / Optional 1   Mandatory activity 
Critical / Non-Critical 2   Non-critical 
Country-Dependency A   Valid for all countries 
Assigned Application Components
Documentation Object Class Documentation Object Name Current line number Application Component Application Component Name
SIMG _ISUDMMR_000010 0 I110004821 Meter Reading 
Maintenance Objects
Maintenance object type C   Customizing Object 
Assigned objects
Customizing Object Object Type Transaction Code Sub-object Do not Summarize Skip Subset Dialog Box Description for multiple selections
TE121 S - Table (with text table) SM30 0000000000 Define Tolerance Limits for Independent Validations 
History
Last changed by/on SAP  19990816 
SAP Release Created in