SAP ABAP Class CL_WFD_CONTAINER_SERVICES (Services for Definition)
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-BMT-WFM (Application Component) SAP Business Workflow
     SWD (Package) Business Workflow: Process Definition
Properties
Class CL_WFD_CONTAINER_SERVICES  
Short Description Services for Definition    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package SWD   Business Workflow: Process Definition 
Created 20001123   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 SWFCN Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 SWFCO Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_WFD_CONTAINER_SERVICES has no interface implemented.
Friends
Class CL_WFD_CONTAINER_SERVICES has no friend class.
Attributes
Class CL_WFD_CONTAINER_SERVICES has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 ALL_ELEMENTS_GET Static method Public Method 20010122
2 ALL_ELEMENTS_OPTIONAL_SET Static method Public Method 20001220
3 ALL_ELEMENTS_PROPS_SET Static method Public Method 20011015
4 ALL_ELEMENTS_SYSTEM_SET Static method Public Method 20010525
5 BASE_ELEMENT_GET_BY_EXPRESSION Static method Public Method 20021021
6 ELEMENTS_COPY Static method Public Method 20010420
7 ELEMENT_DELETE_BY_NAME Static method Public Method 20021024
8 ELEMENT_GET Static method Public Method 20001206
9 ELEMENT_GET_BY_NAME Static method Public Method 20001123
10 ELEMENT_SET Static method Public Method 20001123
11 ELEMENT_SET_UNIQUE Static method Public Method Sets Unique Name Automatically 20030331
12 SHIFT_INTERFACE_TO_TASK Static method Public Method 20001228
Events
Class CL_WFD_CONTAINER_SERVICES has no event.
Types
Class CL_WFD_CONTAINER_SERVICES has no local type.
Method Signatures

Method ALL_ELEMENTS_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EX_ELEMENTS Call by reference Type reference (TYPE) SWDTCNTELE 20010122
2 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20010122

Method ALL_ELEMENTS_GET on class CL_WFD_CONTAINER_SERVICES has no exception.

Method ALL_ELEMENTS_OPTIONAL_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20001220

Method ALL_ELEMENTS_OPTIONAL_SET on class CL_WFD_CONTAINER_SERVICES has no exception.

Method ALL_ELEMENTS_PROPS_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20011015
2 Importing IM_PROPERTIES Call by reference Type reference (TYPE) SWFDBITS64 Ablage von bis zu 64 Eigenschaften als Bit-Konstante 20011015

Method ALL_ELEMENTS_PROPS_SET on class CL_WFD_CONTAINER_SERVICES has no exception.

Method ALL_ELEMENTS_SYSTEM_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20010525

Method ALL_ELEMENTS_SYSTEM_SET on class CL_WFD_CONTAINER_SERVICES has no exception.

Method BASE_ELEMENT_GET_BY_EXPRESSION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20021021
2 Importing IM_EXPRESSION Call by reference Type reference (TYPE) ANY 20021021
3 Returning RE_ELEMENT Value transfer Type reference (TYPE) SWD_CNTELE 20021021
# Exception Resumable Description Created on
1 ELEMENT_NOT_FOUND 20021021

Method ELEMENTS_COPY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_TASK_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER Container - Implementierung einer 'Collection' 20010420
2 Importing IM_WORKFLOW_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20010420

Method ELEMENTS_COPY on class CL_WFD_CONTAINER_SERVICES has no exception.

Method ELEMENT_DELETE_BY_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER Container - Implementierung einer 'Collection' 20021024
2 Importing IM_ELEMENT_NAME Call by reference Type reference (TYPE) ANY Abstraktion eines Containerelements 20021024

Method ELEMENT_DELETE_BY_NAME on class CL_WFD_CONTAINER_SERVICES has no exception.

Method ELEMENT_GET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_ELEMENT Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_ELEMENT Abstraktion eines Containerelements 20001206
2 Returning RE_ELEMENT Value transfer Type reference (TYPE) SWD_CNTELE 20001206

Method ELEMENT_GET on class CL_WFD_CONTAINER_SERVICES has no exception.

Method ELEMENT_GET_BY_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20001123
2 Importing IM_ELEMENT_NAME Call by reference Type reference (TYPE) ANY 20001123
3 Returning RE_ELEMENT Value transfer Type reference (TYPE) SWD_CNTELE 20001123
# Exception Resumable Description Created on
1 ELEMENT_NOT_FOUND 20001123

Method ELEMENT_SET Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER Container - Implementierung einer 'Collection' 20001123
2 Importing IM_ELEMENT Call by reference Type reference (TYPE) SWD_CNTELE 20001123
# Exception Resumable Description Created on
1 ELEMENT_ALREADY_EXISTS 20001207
2 INVALID_TYPE 20011204

Method ELEMENT_SET_UNIQUE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER Container - Implementierung einer 'Collection' 20030331
2 Importing IM_ELEMENT Value transfer Type reference (TYPE) SWD_CNTELE 20030331
3 Returning RE_NAME Value transfer Type reference (TYPE) SWFDNAME Neuer Name 20030331
# Exception Resumable Description Created on
1 INVALID_TYPE 20030331

Method SHIFT_INTERFACE_TO_TASK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_CONTAINER Call by reference Object reference (TYPE REF TO) IF_SWF_CNT_CONTAINER 20001228
# Exception Resumable Description Created on
1 ERROR 20010403
History
Last changed by/on SAP  20110908 
SAP Release Created in 610