Hierarchy

⤷

⤷

Properties
Class | CL_WFD_BINDING_SERVICES | |
Short Description | Binding Generation from Definition | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | SWD | Business Workflow: Process Definition |
Created | 20020228 | SAP |
Last change | 20110908 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_WFD_BINDING_SERVICES has no interface implemented.
Friends
Class CL_WFD_BINDING_SERVICES has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Static Attribute | Public | Type reference (TYPE) | XFELD | Checkbox Field | 20021217 |
Methods
Events
Class CL_WFD_BINDING_SERVICES has no event.
Types
Class CL_WFD_BINDING_SERVICES has no local type.
Method Signatures
Method FOREACH_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20040203 | ||
2 | ![]() |
IM_BLOCK_ELEMENT | Call by reference | Type reference (TYPE) | C | 20040203 |
Method FOREACH_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method FOREACH_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20040203 | |||
2 | ![]() |
IM_BLOCK_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20040203 | |||
3 | ![]() |
IM_BLOCK_ELEMENT | Call by reference | Type reference (TYPE) | C | 20040203 | |||
4 | ![]() |
IM_BLOCK_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20040203 |
Method FOREACH_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2BLOCK_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20021031 | ||
2 | ![]() |
IM_BLOCK_ELEMENT | Call by reference | Type reference (TYPE) | C | 20021031 |
Method WF2BLOCK_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2BLOCK_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20021031 | |||
2 | ![]() |
IM_BLOCK_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20021031 | |||
3 | ![]() |
IM_BLOCK_ELEMENT | Call by reference | Type reference (TYPE) | C | 20021031 | |||
4 | ![]() |
IM_WF_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20021031 | |||
5 | ![]() |
IM_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20021031 |
Method WF2BLOCK_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2CRL_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20021021 | ||
2 | ![]() |
IM_ELEMENT | Call by reference | Type reference (TYPE) | C | 20021021 |
Method WF2CRL_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2CRL_BINDING_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20021021 | |||
2 | ![]() |
IM_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20021021 | |||
3 | ![]() |
IM_CRL_ELEMENT | Call by reference | Type reference (TYPE) | C | 20021021 | |||
4 | ![]() |
IM_INDEX | Call by reference | Type reference (TYPE) | SY-TABIX | 20021021 |
Method WF2CRL_BINDING_GET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2CRL_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20021021 | |||
2 | ![]() |
IM_APPEND | Call by reference | Type reference (TYPE) | XFELD | SPACE | 20021021 | ||
3 | ![]() |
IM_CRL_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20021021 | |||
4 | ![]() |
IM_CRL_ELEMENT | Call by reference | Type reference (TYPE) | C | 20021021 | |||
5 | ![]() |
IM_WF_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20021021 | |||
6 | ![]() |
IM_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20021021 |
Method WF2CRL_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2RULE_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20020514 | ||
2 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | SWFCO_BINDING_WF_TO_AGENT | Workflow-Definition: Typ des Bindings | 20020514 | |
3 | ![]() |
IM_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020514 |
Method WF2RULE_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2RULE_BINDING_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020318 | |||
2 | ![]() |
IM_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020318 | |||
3 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | SWFCO_BINDING_WF_TO_AGENT | Workflow-Definition: Typ des Bindings | 20020318 | |
4 | ![]() |
IM_RULE_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020318 |
Method WF2RULE_BINDING_GET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2RULE_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020318 | |||
2 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | SWFCO_BINDING_WF_TO_AGENT | Workflow-Definition: Typ des Bindings | 20020318 | |
3 | ![]() |
IM_RULE_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020318 | |||
4 | ![]() |
IM_RULE_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020318 | |||
5 | ![]() |
IM_WF_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020318 | |||
6 | ![]() |
IM_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020318 |
Method WF2RULE_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2WI_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20020514 | ||
2 | ![]() |
IM_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020514 |
Method WF2WI_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2WI_BINDING_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020228 | |||
2 | ![]() |
IM_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020228 | |||
3 | ![]() |
IM_INDEX | Call by reference | Type reference (TYPE) | SY-TABIX | 20020627 | |||
4 | ![]() |
IM_WI_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020228 |
Method WF2WI_BINDING_GET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2WI_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020228 | |||
2 | ![]() |
IM_APPEND | Call by reference | Type reference (TYPE) | XFELD | SPACE | 20020627 | ||
3 | ![]() |
IM_WF_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020228 | |||
4 | ![]() |
IM_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020228 | |||
5 | ![]() |
IM_WI_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020228 | |||
6 | ![]() |
IM_WI_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020228 |
Method WF2WI_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2XX_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20020318 | ||
2 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | Workflow-Definition: Typ des Bindings | 20020318 | ||
3 | ![]() |
IM_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020318 |
Method WF2XX_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2XX_BINDING_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_SOURCE_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020318 | |||
2 | ![]() |
IM_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020318 | |||
3 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | 20020318 | |||
4 | ![]() |
IM_INDEX | Call by reference | Type reference (TYPE) | SY-TABIX | 20020627 | |||
5 | ![]() |
IM_TARGET_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020318 |
Method WF2XX_BINDING_GET on class CL_WFD_BINDING_SERVICES has no exception.
Method WF2XX_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020318 | |||
2 | ![]() |
IM_APPEND | Call by reference | Type reference (TYPE) | XFELD | SPACE | 20020627 | ||
3 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | 20020318 | |||
4 | ![]() |
IM_SOURCE_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020318 | |||
5 | ![]() |
IM_SOURCE_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020318 | |||
6 | ![]() |
IM_TARGET_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020318 | |||
7 | ![]() |
IM_TARGET_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020318 |
Method WF2XX_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method WI2WF_BINDING_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020624 | |||
2 | ![]() |
IM_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020624 | |||
3 | ![]() |
IM_WI_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020624 |
Method WI2WF_BINDING_GET on class CL_WFD_BINDING_SERVICES has no exception.
Method WI2WF_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020624 | |||
2 | ![]() |
IM_WF_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020624 | |||
3 | ![]() |
IM_WF_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020624 | |||
4 | ![]() |
IM_WI_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020624 | |||
5 | ![]() |
IM_WI_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020624 |
Method WI2WF_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
Method XX2WF_BINDING_DELETE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | Workflow-Definition: Datenfluß-Tabelle | 20020627 | ||
2 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | Workflow-Definition: Typ des Bindings | 20020627 | ||
3 | ![]() |
IM_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020627 |
Method XX2WF_BINDING_DELETE on class CL_WFD_BINDING_SERVICES has no exception.
Method XX2WF_BINDING_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EX_SOURCE_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020624 | |||
2 | ![]() |
IM_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020624 | |||
3 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | Workflow-Definition: Typ des Bindings | 20020624 | ||
4 | ![]() |
IM_TARGET_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020624 |
Method XX2WF_BINDING_GET on class CL_WFD_BINDING_SERVICES has no exception.
Method XX2WF_BINDING_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CH_BINDING | Call by reference | Type reference (TYPE) | SWDTSTBIND | 20020624 | |||
2 | ![]() |
IM_BINDING_TYPE | Call by reference | Type reference (TYPE) | SWD_BINTYP | Workflow-Definition: Typ des Bindings | 20020624 | ||
3 | ![]() |
IM_SOURCE_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020624 | |||
4 | ![]() |
IM_SOURCE_EXPRESSION | Call by reference | Type reference (TYPE) | C | 20020624 | |||
5 | ![]() |
IM_TARGET_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWF_CNT_CONTAINER | 20020624 | |||
6 | ![]() |
IM_TARGET_ELEMENT | Call by reference | Type reference (TYPE) | C | 20020624 |
Method XX2WF_BINDING_SET on class CL_WFD_BINDING_SERVICES has no exception.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 630 |