SAP ABAP Class CL_SWJ_PPF_CONTAINER_FACTORY (Creates Container Instances)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-BMT-WFM (Application Component) SAP Business Workflow
⤷
SWJ_PPF (Package) Workflow Output Medium in PPF
⤷
⤷
Properties
| Class | CL_SWJ_PPF_CONTAINER_FACTORY | |
| Short Description | Creates Container Instances | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | SWJ_PPF | Workflow Output Medium in PPF |
| Created | 20000606 | SAP |
| Last change | 20001020 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_SWJ_PPF_CONTAINER_FACTORY has no interface implemented.
Friends
Class CL_SWJ_PPF_CONTAINER_FACTORY has no friend class.
Attributes
Class CL_SWJ_PPF_CONTAINER_FACTORY has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Static method | Public | Method | Creates an Empty Container (Customizing) | 20000606 | |
| 2 | Static method | Public | Method | Creates Runtime Containers from a Condition | 20000608 | |
| 3 | Static method | Public | Method | Loads the Container (Customizing) of a Condition | 20000608 | |
| 4 | Static method | Public | Method | Loads a Container (Customizing) | 20000606 | |
| 5 | Static method | Public | Method | Loads a Container (RUNTIME) | 20000608 |
Events
Class CL_SWJ_PPF_CONTAINER_FACTORY has no event.
Types
Class CL_SWJ_PPF_CONTAINER_FACTORY has no local type.
Method Signatures
Method CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CONTAINER | Value transfer | Object reference (TYPE REF TO) | IF_SWJ_PPF_CONTAINER | Workflow-Container Erweiterung für PPF | 20000606 | |||
| 2 | DEFINITION_GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | Definitions GUID | 20021018 | |||
| 3 | TR_DISABLED | Call by reference | Type reference (TYPE) | XFLAG | SPACE | Transport abschalten | 20000606 | ||
| 4 | TR_ORDER | Call by reference | Type reference (TYPE) | TRKORR | Auftrag/Aufgabe | 20000606 |
Method CREATE on class CL_SWJ_PPF_CONTAINER_FACTORY has no exception.
Method CREATE_RUNTIME Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CONDITION_GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | ID der Bedingung | 20000608 | |||
| 2 | CONTAINER | Value transfer | Object reference (TYPE REF TO) | IF_SWJ_PPF_CONTAINER | Container RUNTIME | 20000608 | |||
| 3 | CONTAINER_GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | überdefinierter Customizing Container | 20000608 | |||
| 4 | CUST_CONTAINER | Call by reference | Object reference (TYPE REF TO) | IF_SWJ_PPF_CONTAINER | überdefinierter Customizing Container | 20020830 |
Method CREATE_RUNTIME on class CL_SWJ_PPF_CONTAINER_FACTORY has no exception.
Method GET_INSTANCE_BY_COND Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CONDITION_GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | Kennung | 20000608 | |||
| 2 | CONTAINER | Value transfer | Object reference (TYPE REF TO) | IF_SWJ_PPF_CONTAINER | Workflow-Container Erweiterung für PPF | 20000608 |
Method GET_INSTANCE_BY_COND on class CL_SWJ_PPF_CONTAINER_FACTORY has no exception.
Method GET_INSTANCE_BY_KEY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CONTAINER | Value transfer | Object reference (TYPE REF TO) | IF_SWJ_PPF_CONTAINER | Workflow-Container Erweiterung für PPF | 20000606 | |||
| 2 | EDITOR_FUNCNAME | Call by reference | Type reference (TYPE) | SWJ_FNAME | Funktionsbaustein für Parametrisierung | 20000608 | |||
| 3 | GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | Kennung | 20000606 | |||
| 4 | TR_DISABLED | Call by reference | Type reference (TYPE) | XFLAG | SPACE | Transport abschalten | 20000606 | ||
| 5 | TR_ORDER | Call by reference | Type reference (TYPE) | TRKORR | Auftrag/Aufgabe | 20000606 |
Method GET_INSTANCE_BY_KEY on class CL_SWJ_PPF_CONTAINER_FACTORY has no exception.
Method GET_RUNTIME_INSTANCE_BY_KEY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CONTAINER | Value transfer | Object reference (TYPE REF TO) | IF_SWJ_PPF_CONTAINER | Workflow-Container Erweiterung für PPF | 20000608 | |||
| 2 | DEFINITION_GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | ID der Container-Definition | 20000608 | |||
| 3 | EDITOR_FUNCNAME | Call by reference | Type reference (TYPE) | SWJ_FNAME | Funktionsbaustein für Parametrisierung | 20000608 | |||
| 4 | GUID | Call by reference | Type reference (TYPE) | SWJ_CONDID | ID des Laufzeitcontainers | 20000608 |
Method GET_RUNTIME_INSTANCE_BY_KEY on class CL_SWJ_PPF_CONTAINER_FACTORY has no exception.
History
| Last changed by/on | SAP | 20001020 |
| SAP Release Created in | 46D |