SAP ABAP Class CL_SWF_TST_WFUNIT_NO02 (WorkitemSelectionFull (OSP))
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-BMT-WFM (Application Component) SAP Business Workflow
     SWF_TST (Package) Workflow: Test Objects
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_SWF_TST_WFUNIT Workflow: Workflow-Unittest 20050805
Properties
Class CL_SWF_TST_WFUNIT_NO02  
Short Description WorkitemSelectionFull (OSP)    
Super Class CL_SWF_TST_WFUNIT Workflow: Workflow-Unittest 
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status P  SAP Standard Production Program 
Category 0   
Package SWF_TST   Workflow: Test Objects 
Created 20050805   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 SWN1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 SWNU1 Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_SWF_TST_WFUNIT_NO02 has no interface implemented.
Friends
Class CL_SWF_TST_WFUNIT_NO02 has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 C_FILTER_DELTA Constant Private Type reference (TYPE) SWN_FILTID 'WFUNIT_NO02_DELTA' 20050805
2 C_FILTER_FULL Constant Private Type reference (TYPE) SWN_FILTID 'WFUNIT_NO02_ALL' 20050805
3 C_TASK Constant Private Type reference (TYPE) SWW_TASK 'TS56407969' 20050805
4 C_WORKFLOW_TASK Constant Private Type reference (TYPE) SWW_TASK 'WS56400351' 20050805
5 M_CATEGORY Instance attribute Private Type reference (TYPE) SWN_CATID 20050805
6 M_SCENARIO Instance attribute Private Type reference (TYPE) SWN_SCENID 20050805
Methods
# Method Level Visibility Method type Description Created on
1 CHECK_RESULT Instance method Private Method 20050805
2 CLASS_CONSTRUCTOR Static method Public Constructor 20050805
3 CONSTRUCTOR Instance method Public Constructor 20050805
4 DELETE_CONFIGURATION Instance method Private Method 20050805
5 EXECUTE_INTERNAL Instance method Private Method 20050805
6 SET_CONFIGURATION Instance method Private Method 20050805
7 START_NOTIFICATION_PROCESS Instance method Private Method 20050805
Events
Class CL_SWF_TST_WFUNIT_NO02 has no event.
Types
Class CL_SWF_TST_WFUNIT_NO02 has no local type.
Method Signatures

Method CHECK_RESULT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_WIID Call by reference Type reference (TYPE) SWW_WIID Workitem-Kennung 20050805

Method CHECK_RESULT on class CL_SWF_TST_WFUNIT_NO02 has no exception.

Method CLASS_CONSTRUCTOR Signature

Method CLASS_CONSTRUCTOR on class CL_SWF_TST_WFUNIT_NO02 has no parameter.
Method CLASS_CONSTRUCTOR on class CL_SWF_TST_WFUNIT_NO02 has no exception.

Method CONSTRUCTOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_TASK Call by reference Type reference (TYPE) C 20050805
# Exception Resumable Description Created on
1 CX_SWF_RUN_WIM Ausnahme im WIM 20050805

Method DELETE_CONFIGURATION Signature

Method DELETE_CONFIGURATION on class CL_SWF_TST_WFUNIT_NO02 has no parameter.
Method DELETE_CONFIGURATION on class CL_SWF_TST_WFUNIT_NO02 has no exception.

Method EXECUTE_INTERNAL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IM_BASISOFCOMPARISON Call by reference Type reference (TYPE) STRING 20050805
# Exception Resumable Description Created on
1 CX_SWF_RUN_WIM Ausnahme im WIM 20050805

Method SET_CONFIGURATION Signature

Method SET_CONFIGURATION on class CL_SWF_TST_WFUNIT_NO02 has no parameter.
# Exception Resumable Description Created on
1 CONFIGURATION_FAILED Konfiguration konnte nicht angelegt werden 20050805

Method START_NOTIFICATION_PROCESS Signature

Method START_NOTIFICATION_PROCESS on class CL_SWF_TST_WFUNIT_NO02 has no parameter.
Method START_NOTIFICATION_PROCESS on class CL_SWF_TST_WFUNIT_NO02 has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in 710