SAP ABAP Class CL_SWF_EVT_INST_LINKAGE (Instance-Dependent Event Linkage)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-BMT-WFM (Application Component) SAP Business Workflow
⤷
SWF_EVT (Package) Workflow: Events
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_SWF_EVT_INSTANCE_LINKAGE | Instance-Dependent Event Linkage | 20000712 |
Properties
| Class | CL_SWF_EVT_INST_LINKAGE | |
| Short Description | Instance-Dependent Event Linkage | |
| Super Class | ||
| Instantiability of a Class | 1 | Protected |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | SWF_EVT | Workflow: Events |
| Created | 20000712 | SAP |
| Last change | 20110908 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class CL_SWF_EVT_INST_LINKAGE has no forward declaration.
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_SWF_EVT_INSTANCE_LINKAGE | Instance-Dependent Event Linkage | 20000712 |
Friends
Class CL_SWF_EVT_INST_LINKAGE has no friend class.
Attributes
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Constructor | Constructor | 20000712 | |
| 2 | Static method | Public | Method | Copies instance linkages | 20000830 | |
| 3 | Static method | Public | Method | Gets a new linkage | 20000712 | |
| 4 | Static method | Public | Method | Deletes an instance linkage | 20000830 | |
| 5 | Static method | Public | Method | Deletes instance linkages using the instance key | 20000830 | |
| 6 | Static method | Public | Method | Deletes for receiver key in various clients | 20001122 | |
| 7 | Static method | Public | Method | Gets an existing linkage | 20000712 | |
| 8 | Static method | Private | Method | Gets the next number for the key | 20001110 | |
| 9 | Instance method | Private | Method | Loads the object from the database | 20000712 | |
| 10 | Static method | Public | Method | Loads several instances using selection criteria | 20000901 | |
| 11 | Instance method | Public | Method | 20000712 | ||
| 12 | Instance method | Private | Method | Sets the interface attributes | 20000901 |
Events
Class CL_SWF_EVT_INST_LINKAGE has no event.
Types
| # | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
|---|---|---|---|---|---|---|---|
| 1 | T_INSTANCE | Private | See coding | T_INSTANCE | 20000712 | |
Method Signatures
Method CONSTRUCTOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_EVENT | Call by reference | Type reference (TYPE) | C | Ereignis | 20000712 | |||
| 2 | IM_EXISTENCE_CHECK | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20000712 | |||
| 3 | IM_FOR_ALL_INSTANCES | Call by reference | Type reference (TYPE) | XFELD | Für alle Instanzen | 20000712 | |||
| 4 | IM_LINKAGE | Call by reference | Type reference (TYPE) | SWFDEVLNK | Ereigniskopplung | 20000901 | |||
| 5 | IM_OBJCATEG | Call by reference | Type reference (TYPE) | SWF_CLSTYP | Workflow: Objekttyp BO , CL ... | 20000921 | |||
| 6 | IM_OBJKEY | Call by reference | Type reference (TYPE) | C | Objektschlüssel | 20000712 | |||
| 7 | IM_OBJTYPE | Call by reference | Type reference (TYPE) | C | Objekttyp | 20000712 | |||
| 8 | IM_RECKEY | Call by reference | Type reference (TYPE) | C | Objektschlüssel (Verbraucher) | 20000712 | |||
| 9 | IM_RECTYPE | Call by reference | Type reference (TYPE) | C | Verbrauchertyp | 20000712 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Kopplung nicht gefunden | 20000712 |
Method COPY_LINKAGES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_CLIENT | Call by reference | Type reference (TYPE) | SY-MANDT | SY-MANDT | R/3-System, Mandantennummer aus Anmeldung | 20000830 | ||
| 2 | IM_NEW_RECKEY | Call by reference | Type reference (TYPE) | SIBFBORIID | Instanzident. in BOR kompat. Persistenten Objektreferenzen | 20000830 | |||
| 3 | IM_NEW_RECTYPE | Call by reference | Type reference (TYPE) | SWFERECTYP | Name des Verbrauchertyps | 20000830 | |||
| 4 | IM_ORG_RECKEY | Call by reference | Type reference (TYPE) | SIBFBORIID | Instanzidentifikation in Persistenten Objektreferenzen | 20000830 | |||
| 5 | IM_ORG_RECTYPE | Call by reference | Type reference (TYPE) | SWFERECTYP | Name des Verbrauchertyps | 20000830 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Ausnahme beim Ändern auf DB | 20000830 |
Method CREATE_LINKAGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_EVENT | Call by reference | Type reference (TYPE) | C | Ereignis | 20000712 | |||
| 2 | IM_FOR_ALL_INSTANCES | Call by reference | Type reference (TYPE) | XFELD | Feld zum Ankreuzen | 20000712 | |||
| 3 | IM_OBJCATEG | Call by reference | Type reference (TYPE) | SWF_CLSTYP | Objektkategorie | 20000921 | |||
| 4 | IM_OBJKEY | Call by reference | Type reference (TYPE) | C | Objektschlüssel | 20000712 | |||
| 5 | IM_OBJTYPE | Call by reference | Type reference (TYPE) | C | Objekttyp | 20000712 | |||
| 6 | IM_RECKEY | Call by reference | Type reference (TYPE) | C | Objektschlüssel (Verbraucher) | 20000712 | |||
| 7 | IM_RECTYPE | Call by reference | Type reference (TYPE) | C | Verbrauchertyp | 20000712 | |||
| 8 | RE_INST_LINKAGE | Value transfer | Object reference (TYPE REF TO) | CL_SWF_EVT_INST_LINKAGE | Instanzabhängige Ereigniskopplung | 20000712 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Kopplung existiert bereits | 20000712 | ||
| 2 | Kopplung nicht gefunden | 20000712 |
Method DELETE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_CLIENT | Call by reference | Type reference (TYPE) | SY-MANDT | SY-MANDT | R/3-System, Mandantennummer aus Anmeldung | 20000830 | ||
| 2 | IM_EVENT | Value transfer | Type reference (TYPE) | SWO_EVENT | Ereignis | 20000830 | |||
| 3 | IM_OBJCATEG | Call by reference | Type reference (TYPE) | SWF_CLSTYP | Objektkategorie | 20000921 | |||
| 4 | IM_OBJKEY | Call by reference | Type reference (TYPE) | SIBFBORIID | Instanzident. in BOR kompat. Persistenten Objektreferenzen | 20000830 | |||
| 5 | IM_OBJTYPE | Call by reference | Type reference (TYPE) | SIBFTYPEID | Typ von Objekten in Persistenten Objektreferenzen | 20000830 | |||
| 6 | IM_RECKEY | Call by reference | Type reference (TYPE) | SIBFBORIID | Instanzident. in BOR kompat. Persistenten Objektreferenzen | 20000830 | |||
| 7 | IM_RECTYPE | Call by reference | Type reference (TYPE) | SWFERECTYP | Name des Verbrauchertyps | 20000830 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Ausnahme beim Ändern auf DB | 20000830 |
Method DELETE_BY_KEY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_CLIENT | Call by reference | Type reference (TYPE) | SY-MANDT | SY-MANDT | R/3-System, Mandantennummer aus Anmeldung | 20000830 | ||
| 2 | IM_EVENT | Value transfer | Type reference (TYPE) | C | Ereignis | 20000830 | |||
| 3 | IM_RECKEY | Call by reference | Type reference (TYPE) | C | Instanzident. in BOR kompat. Persistenten Objektreferenzen | 20000830 | |||
| 4 | IM_RECTYPE | Call by reference | Type reference (TYPE) | C | Verbrauchertyp | 20010221 | |||
| 5 | IM_VALIDATE | Call by reference | Type reference (TYPE) | XFELD | 'X' | 20031114 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Ausnahme beim Ändern auf DB | 20000830 |
Method DELETE_BY_RECKEY_CLIENT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_EVENT | Call by reference | Type reference (TYPE) | C | Ereignis | 20001122 | |||
| 2 | IM_OBJCATEG | Call by reference | Type reference (TYPE) | SWF_CLSTYP | Workflow: Objektkategorie | 20001122 | |||
| 3 | IM_OBJTYPE | Call by reference | Type reference (TYPE) | C | Objekttyp, Klasse | 20001122 | |||
| 4 | IM_RECKEYS_CLIENT | Call by reference | Type reference (TYPE) | SWFDEVRCKYT | Tabelle für Verbraucherschlüssel je Mandant | 20001122 | |||
| 5 | IM_RECTYPE | Call by reference | Type reference (TYPE) | C | Verbrauchertyp | 20001122 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Ausnahme beim Löschen aus DB | 20001122 |
Method GET_LINKAGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_EVENT | Call by reference | Type reference (TYPE) | C | Ereignis | 20000712 | |||
| 2 | IM_FOR_ALL_INSTANCES | Call by reference | Type reference (TYPE) | XFELD | Für alle Instanzen | 20000712 | |||
| 3 | IM_LINKAGE | Call by reference | Type reference (TYPE) | SWFDEVLNK | Ereigniskopplung | 20000901 | |||
| 4 | IM_OBJCATEG | Call by reference | Type reference (TYPE) | SWF_CLSTYP | Objektkategorie | 20000921 | |||
| 5 | IM_OBJKEY | Call by reference | Type reference (TYPE) | C | Objektschlüssel des Auslösers | 20000712 | |||
| 6 | IM_OBJTYPE | Call by reference | Type reference (TYPE) | C | Objekttyp | 20000712 | |||
| 7 | IM_RECKEY | Call by reference | Type reference (TYPE) | C | Objektschlüssel des Verbrauchers | 20000712 | |||
| 8 | IM_RECTYPE | Call by reference | Type reference (TYPE) | C | Verbrauchertyp | 20000712 | |||
| 9 | RE_INST_LINKAGE | Value transfer | Object reference (TYPE REF TO) | CL_SWF_EVT_INST_LINKAGE | Instanzabhängige Ereigniskopplung | 20000712 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Kopplung nicht gefunden | 20000712 |
Method GET_NEXT_NUMBER Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | RE_NUMBER | Value transfer | Type reference (TYPE) | SWE_NUMBER | Fortlaufende Nummer der Instanzkopplung (Keyersatz) | 20001110 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Ausnahme beim Ändern auf DB | 20001110 |
Method LOAD Signature
Method LOAD on class CL_SWF_EVT_INST_LINKAGE has no parameter.
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Kopplung nicht gefunden | 20000712 |
Method LOAD_LINKAGES Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_RANGE_EVENT | Call by reference | Type reference (TYPE) | STANDARD TABLE | Range für Ereignis | 20000901 | |||
| 2 | IM_RANGE_OBJCATEG | Call by reference | Type reference (TYPE) | STANDARD TABLE | Range für Objekt-Kategory | 20000921 | |||
| 3 | IM_RANGE_OBJKEY | Call by reference | Type reference (TYPE) | STANDARD TABLE | Range für Objektschlüssel | 20000901 | |||
| 4 | IM_RANGE_OBJTYPE | Call by reference | Type reference (TYPE) | STANDARD TABLE | Range für Objekttyp | 20000901 | |||
| 5 | IM_RANGE_RECKEY | Call by reference | Type reference (TYPE) | STANDARD TABLE | Range für Verbraucherschlüssel | 20001018 | |||
| 6 | RE_LINKAGES | Value transfer | Type reference (TYPE) | SWFDINSTLNKS | Tabelle für Referenzen von Ereignis-Instanz-Kopplungen | 20000901 |
Method LOAD_LINKAGES on class CL_SWF_EVT_INST_LINKAGE has no exception.
Method SAVE_TO_DATABASE Signature
Method SAVE_TO_DATABASE on class CL_SWF_EVT_INST_LINKAGE has no parameter.
Method SAVE_TO_DATABASE on class CL_SWF_EVT_INST_LINKAGE has no exception.
Method SET_INTERFACE_ATTRIBUTES Signature
Method SET_INTERFACE_ATTRIBUTES on class CL_SWF_EVT_INST_LINKAGE has no parameter.
Method SET_INTERFACE_ATTRIBUTES on class CL_SWF_EVT_INST_LINKAGE has no exception.
History
| Last changed by/on | SAP | 20110908 |
| SAP Release Created in | 610 |