SAP ABAP Class CL_SWF_BPE_RECEPTOR (BPE: Component for Wait Step)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-BMT-WFM (Application Component) SAP Business Workflow
⤷
SWP (Package) Business Workflow: Processor

⤷

⤷

Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_SWF_WFM_RECEPTOR | WFM: Process Component "Step" | 20061122 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_SWF_WFM_WI_CREATE_ON_DEMAND | Creation of a Work Item on Demand | 20070105 |
Properties
Class | CL_SWF_BPE_RECEPTOR | |
Short Description | BPE: Component for Wait Step | |
Super Class | CL_SWF_WFM_RECEPTOR | WFM: Process Component "Step" |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | SWP | Business Workflow: Processor |
Created | 20061122 | SAP |
Last change | 20110908 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) |
2 | ![]() |
Forward declaration interface (INTERFACE i DEFINITION DEF... | Forward declaration interface (INTERFACE i DEFINITION DEF... |
3 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_SWF_WFM_WI_CREATE_ON_DEMAND | Creation of a Work Item on Demand | 20070105 |
Friends
Class CL_SWF_BPE_RECEPTOR has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Static Attribute | Private | Type reference (TYPE) | SWF_T100MS | 20070103 | |||
2 | ![]() |
Static Attribute | Private | Type reference (TYPE) | TIMESTAMPL | 20070103 | |||
3 | ![]() |
Constant | Private | Type reference (TYPE) | SWFDNAME | SWFCO_TRANSIENT_OBJ_USED | Element ID (32 Characters, Unique, Not Language-Dependent) | 20070305 | |
4 | ![]() |
Instance attribute | Private | Type reference (TYPE) | IF_SWF_RUN_WFM_INTERNAL=>TY_CRLS_T | 20070124 | |||
5 | ![]() |
Instance attribute | Private | Type reference (TYPE) | IF_SWF_RUN_WFM_INTERNAL=>TY_CRLS_T | 20070130 | |||
6 | ![]() |
Instance attribute | Private | Type reference (TYPE) | TIMESTAMPL | 20061130 | |||
7 | ![]() |
Instance attribute | Private | Type reference (TYPE) | FLAG | 20070105 | |||
8 | ![]() |
Instance attribute | Private | Type reference (TYPE) | SIBFLPOR | 20061201 | |||
9 | ![]() |
Instance attribute | Private | Type reference (TYPE) | I | 20070820 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Constructor | 20061122 | |
2 | ![]() |
Static method | Public | Method | 20061122 | |
3 | ![]() |
Static method | Private | Method | 20061123 | |
4 | ![]() |
Instance method | Public | Method | 20061123 | |
5 | ![]() |
Instance method | Private | Method | 20070125 | |
6 | ![]() |
Instance method | Public | Method | 20061130 | |
7 | ![]() |
Instance method | Private | Method | 20061130 | |
8 | ![]() |
Static method | Public | Method | 20061122 | |
9 | ![]() |
Instance method | Public | Method | 20061123 | |
10 | ![]() |
Instance method | Private | Method | 20070305 | |
11 | ![]() |
Instance method | Public | Method | 20070820 |
Events
Class CL_SWF_BPE_RECEPTOR has no event.
Types
Class CL_SWF_BPE_RECEPTOR has no local type.
Method Signatures
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CALLBACK_ENTRY | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_CALLBACK_ENTRY | 20061122 | |||
2 | ![]() |
IM_CALLBACK_RESULT | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_RESULT | 20061122 | |||
3 | ![]() |
IM_COMPONENT_FACTORY | Call by reference | Object reference (TYPE REF TO) | IF_SWF_WFM_CMP_FACT_COMPONENT | 20061122 | |||
4 | ![]() |
IM_DISCARD_AT_CLEANUP | Call by reference | Type reference (TYPE) | FLAG | 20061122 | |||
5 | ![]() |
IM_NODE_DEFINITION | Call by reference | Type reference (TYPE) | SWD_SNODES | 20061122 | |||
6 | ![]() |
IM_NODE_L_IND | Value transfer | Type reference (TYPE) | SWP_LOOPIND | 20061122 | |||
7 | ![]() |
IM_NODE_P_IND | Value transfer | Type reference (TYPE) | SWP_PARIND | 20061122 | |||
8 | ![]() |
IM_PARENT | Call by reference | Object reference (TYPE REF TO) | CL_SWF_WFM_COMPOSITE | 20061122 | |||
9 | ![]() |
IM_PERSISTENCE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_WFM_COMPONENT_PERSIST | 20061122 | |||
10 | ![]() |
IM_PRED_NODE_ID | Value transfer | Type reference (TYPE) | SWD_NODEID | 20061122 | |||
11 | ![]() |
IM_PRED_NODE_P_IND | Value transfer | Type reference (TYPE) | SWP_PARIND | 20061122 | |||
12 | ![]() |
IM_STEP_DEFINITION | Call by reference | Type reference (TYPE) | SWD_SSTEPS | 20061122 | |||
13 | ![]() |
IM_WFM_HANDLE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_WFM_INTERNAL | 20061122 | |||
14 | ![]() |
IM_WIM_HANDLE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_WIM_WFM | 20061122 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20061122 |
Method CREATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_COMPONENT_FACTORY | Call by reference | Object reference (TYPE REF TO) | IF_SWF_WFM_CMP_FACT_COMPONENT | 20061122 | |||
2 | ![]() |
IM_NODE_DEFINITION | Call by reference | Type reference (TYPE) | SWD_SNODES | 20061122 | |||
3 | ![]() |
IM_NODE_L_IND | Value transfer | Type reference (TYPE) | SWP_LOOPIND | 20061122 | |||
4 | ![]() |
IM_NODE_P_IND | Value transfer | Type reference (TYPE) | SWP_PARIND | 20061122 | |||
5 | ![]() |
IM_PARENT | Call by reference | Object reference (TYPE REF TO) | CL_SWF_WFM_COMPOSITE | 20061122 | |||
6 | ![]() |
IM_PRED_NODE_ID | Call by reference | Type reference (TYPE) | SWD_NODEID | 20061122 | |||
7 | ![]() |
IM_PRED_NODE_P_IND | Call by reference | Type reference (TYPE) | SWP_PARIND | 20061122 | |||
8 | ![]() |
IM_STEP_DEFINITION | Call by reference | Type reference (TYPE) | SWD_SSTEPS | 20061122 | |||
9 | ![]() |
IM_WFM_HANDLE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_WFM_INTERNAL | 20061122 | |||
10 | ![]() |
RE_RECEPTOR | Value transfer | Object reference (TYPE REF TO) | CL_SWF_BPE_RECEPTOR | 20061122 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20061122 |
Method CREATE_EVENT_OBJECT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_MSG_KEY | Call by reference | Type reference (TYPE) | SIBFLPOR | 20061123 | |||
2 | ![]() |
IM_WF_ID | Call by reference | Type reference (TYPE) | SWW_WIID | 20061123 | |||
3 | ![]() |
RE_EVENT_OBJECT | Value transfer | Object reference (TYPE REF TO) | IF_SWF_RUN_WIM_EVENT | 20061123 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20070103 |
Method DELIVER_MESSAGE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_MSG_KEY | Call by reference | Type reference (TYPE) | SIBFLPOR | 20061123 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20070105 |
Method DETERMINE_CORRELATIONS Signature
Method DETERMINE_CORRELATIONS on class CL_SWF_BPE_RECEPTOR has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20070125 |
Method GET_CREATION_TIMESTAMP Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_CREATION_TIMESTAMP | Value transfer | Type reference (TYPE) | TIMESTAMPL | 20061130 |
Method GET_CREATION_TIMESTAMP on class CL_SWF_BPE_RECEPTOR has no exception.
Method INITIALIZE Signature
Method INITIALIZE on class CL_SWF_BPE_RECEPTOR has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20070105 |
Method LOAD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CALLBACK_ENTRY | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_CALLBACK_ENTRY | Callback-Eintrag | 20061122 | ||
2 | ![]() |
IM_CALLBACK_RESULT | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_RESULT | Workflow: Result | 20061122 | ||
3 | ![]() |
IM_COMPATIBILITY_MODE | Value transfer | Type reference (TYPE) | FLAG | allgemeines flag | 20061122 | ||
4 | ![]() |
IM_COMPONENT_FACTORY | Call by reference | Object reference (TYPE REF TO) | IF_SWF_WFM_CMP_FACT_COMPONENT | WFM: Komponentenfabrik-Interface für Komponenten | 20061122 | ||
5 | ![]() |
IM_DISCARD_AT_CLEANUP | Call by reference | Type reference (TYPE) | FLAG | allgemeines flag | 20061122 | ||
6 | ![]() |
IM_PARENT | Call by reference | Object reference (TYPE REF TO) | CL_SWF_WFM_COMPOSITE | WFM: Strukturierte Prozesskomponente | 20061122 | ||
7 | ![]() |
IM_PERSISTENCE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_WFM_COMPONENT_PERSIST | Persistenz für WFM-Komponenten | 20061122 | ||
8 | ![]() |
IM_WFM_HANDLE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_WFM_INTERNAL | WFM-Interface für WFM-Komponenten | 20061122 | ||
9 | ![]() |
IM_WIM_HANDLE | Call by reference | Object reference (TYPE REF TO) | IF_SWF_RUN_WIM_WFM | Workflow: WIM Interface für WFM | 20061122 | ||
10 | ![]() |
RE_COMPONENT | Value transfer | Object reference (TYPE REF TO) | IF_SWF_WFM_COMPONENT | WFM: Prozesskomponente | 20061122 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20061122 |
Method MATCH Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CORRELATIONS | Call by reference | Type reference (TYPE) | CL_SWF_CRL_SP=>TY_CRLKEY_T | 20061123 | |||
2 | ![]() |
IM_MESSAGE | Call by reference | Type reference (TYPE) | SIBFLPOR | 20061201 | |||
3 | ![]() |
RE_MATCH | Value transfer | Type reference (TYPE) | FLAG | 20061123 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
20070105 |
Method REGISTER_FOR_WI2OBJ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_MESSAGE | Call by reference | Type reference (TYPE) | SIBFLPOR | Lokale Persistente Objektreferenz | 20070305 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ausnahme im Container-Service | 20070305 | |
2 | ![]() |
WFM: Ausnahme | 20070305 |
Method SET_RUNTIME_MICROS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_MICROSECONDS | Call by reference | Type reference (TYPE) | I | 20070820 |
Method SET_RUNTIME_MICROS on class CL_SWF_BPE_RECEPTOR has no exception.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 700 |