SAP ABAP Class CL_REEX_PM_SERVICES (General Access Methods)
Hierarchy
☛
EA-FIN (Software Component) EA-FIN
⤷ RE-FX-BD (Application Component) Basic Data
⤷ RE_EX_PM (Package) RE: Plant Maintenance
⤷ RE-FX-BD (Application Component) Basic Data
⤷ RE_EX_PM (Package) RE: Plant Maintenance
Properties
Class | CL_REEX_PM_SERVICES | |
Short Description | General Access Methods | |
Super Class | ||
Instantiability of a Class | 0 | Private |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | RE_EX_PM | RE: Plant Maintenance |
Created | 20040112 | SAP |
Last change | 20100310 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ABAP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | RECA0 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
3 | RECA1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
4 | RECA4 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
5 | RESC1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_REEX_PM_SERVICES has no interface implemented.
Friends
Class CL_REEX_PM_SERVICES has no friend class.
Attributes
Class CL_REEX_PM_SERVICES has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ADD_BUSOBJ | Static method | Public | Method | Adds the Object | 20040112 |
2 | CLASS_CONSTRUCTOR | Static method | Public | Constructor | CLASS_CONSTRUCTOR | 20040112 |
3 | FIND_BUSOBJ_BY_OBJID | Static method | Public | Method | Gets the Object | 20040112 |
4 | FIND_BUSOBJ_BY_OBJNR | Static method | Public | Method | Gets the Object | 20040112 |
5 | GET_EQUIPMENTS_FOR_FUNCLOC | Static method | Public | Method | Gets All Equipment for a Functional Location | 20060718 |
6 | GET_FIELDS | Static method | Protected | Method | Gets All Necessary Data | 20040402 |
7 | GET_FUNCLOCS_FOR_EQUIPMENT | Static method | Public | Method | Gets All Functional Locations for Pc.of Equipment (Installed | 20060808 |
8 | GET_FUNCLOCS_FOR_ORDER | Static method | Public | Method | Gets All Functional Locations for an Order | 20050603 |
9 | GET_ORDERS_FOR_FUNCLOC | Static method | Public | Method | Gets All Orders for a Functional Location | 20050603 |
10 | HANDLE_BUFFER_RESET_ALL | Static method | Protected | Event handling method | Deletes All Entries in Table Buffer | 20040127 |
11 | RESET | Static method | Protected | Method | Resets Buffer | 20040405 |
Events
Class CL_REEX_PM_SERVICES has no event.
Types
Class CL_REEX_PM_SERVICES has no local type.
Method Signatures
Method ADD_BUSOBJ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_BUSOBJ | Call by reference | Object reference (TYPE REF TO) | IF_RECA_BUS_OBJECT | Business-Objekt | 20040402 |
Method ADD_BUSOBJ on class CL_REEX_PM_SERVICES has no exception.
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class CL_REEX_PM_SERVICES has no parameter.
Method CLASS_CONSTRUCTOR on class CL_REEX_PM_SERVICES has no exception.
Method FIND_BUSOBJ_BY_OBJID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_OBJECT | Call by reference | Type reference (TYPE) | REEXPMOBJINFOFORMETER | Objektnummer zum Anlegen von Zähler | 20040405 | ||
2 | Importing | ID_ACTIVITY | Call by reference | Type reference (TYPE) | RECA1_ACTIVITY | RECA1_ACTIVITY-DISPLAY | Aktivitäte für Berechtigungsprüfung | 20090327 | |
3 | Importing | ID_OBJID | Call by reference | Type reference (TYPE) | IBIPMEAS-BUSOBJID | Objekt-ID eines RE:Objekts | 20040112 | ||
4 | Importing | ID_OBJTYPE | Call by reference | Type reference (TYPE) | IBIPMEAS-BUSOBJTYPE | RE: Objektart | 20040112 | ||
5 | Importing | IF_AUTH_CHECK | Call by reference | Type reference (TYPE) | ABAP_BOOL | ABAP_FALSE | Berechtigungsprüfung durchführen? | 20090327 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20040112 |
Method FIND_BUSOBJ_BY_OBJNR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_OBJECT | Call by reference | Type reference (TYPE) | REEXPMOBJINFOFORMETER | Objektnummer zum Anlegen von Zähler | 20040405 | ||
2 | Importing | ID_OBJNR | Call by reference | Type reference (TYPE) | RECAOBJNR | Objektnummer | 20040112 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ERROR | Fehler | 20040112 |
Method GET_EQUIPMENTS_FOR_FUNCLOC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | ID_KEYDATE | Call by reference | Type reference (TYPE) | RECAKEYDATE | SY-DATUM | Stichtag | 20060718 | |
2 | Importing | ID_OBJNR | Call by reference | Type reference (TYPE) | IFLO-OBJNR | Technischer Platz (Objektnummer) | 20060718 | ||
3 | Importing | ID_TPLNR | Call by reference | Type reference (TYPE) | IFLO-TPLNR | Technischer Platz (Nummer) | 20060718 | ||
4 | Returning | RT_EQUI | Value transfer | Type reference (TYPE) | RE_T_EQUI | Equipments | 20060718 |
Method GET_EQUIPMENTS_FOR_FUNCLOC on class CL_REEX_PM_SERVICES has no exception.
Method GET_FIELDS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | ES_OBJECT | Call by reference | Type reference (TYPE) | REEXPMOBJINFOFORMETER | Objektnummer zum Anlegen von Zähler | 20040405 | ||
2 | Importing | IO_BUSOBJ | Call by reference | Object reference (TYPE REF TO) | IF_RECA_BUS_OBJECT | Business-Objekt | 20040402 |
Method GET_FIELDS on class CL_REEX_PM_SERVICES has no exception.
Method GET_FUNCLOCS_FOR_EQUIPMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | ID_EQUNR | Call by reference | Type reference (TYPE) | EQUI-EQUNR | Equipment (Nummer) | 20060808 | ||
2 | Importing | ID_KEYDATE | Call by reference | Type reference (TYPE) | RECAKEYDATE | RECA0_DATE-MIN | Stichtag (Alle, wenn initial) | 20060808 | |
3 | Importing | ID_OBJNR | Call by reference | Type reference (TYPE) | IFLO-OBJNR | Equipment (Objektnummer) | 20060808 | ||
4 | Returning | RT_ITOB | Value transfer | Type reference (TYPE) | RE_T_ITOB | Technische Plätze | 20060808 |
Method GET_FUNCLOCS_FOR_EQUIPMENT on class CL_REEX_PM_SERVICES has no exception.
Method GET_FUNCLOCS_FOR_ORDER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | ID_AUFNR | Call by reference | Type reference (TYPE) | VVIEXPMFL2OR-AUFNR | Auftrag (Nummer) | 20050603 | ||
2 | Importing | ID_OBJNR | Call by reference | Type reference (TYPE) | VVIEXPMFL2OR-OBJNR_OR | Auftrag (Objektnummer) | 20050603 | ||
3 | Returning | RT_VVIEXPMFL2OR | Value transfer | Type reference (TYPE) | RE_T_VVIEXPMFL2OR | Technische Plätze zu Aufträgen (VVIEXPMFL2OR) | 20050603 |
Method GET_FUNCLOCS_FOR_ORDER on class CL_REEX_PM_SERVICES has no exception.
Method GET_ORDERS_FOR_FUNCLOC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | ID_OBJNR | Call by reference | Type reference (TYPE) | VVIEXPMOR2FL-OBJNR_FL | Technischer Platz (Objektnummer) | 20050603 | ||
2 | Importing | ID_TPLNR | Call by reference | Type reference (TYPE) | VVIEXPMOR2FL-TPLNR | Technischer Platz (Nummer) | 20050603 | ||
3 | Returning | RT_VVIEXPMOR2FL | Value transfer | Type reference (TYPE) | RE_T_VVIEXPMOR2FL | Aufträge zu Technischen Plätzen (VVIEXPMOR2FL) | 20050603 |
Method GET_ORDERS_FOR_FUNCLOC on class CL_REEX_PM_SERVICES has no exception.
Method HANDLE_BUFFER_RESET_ALL Signature
Method HANDLE_BUFFER_RESET_ALL on class CL_REEX_PM_SERVICES has no parameter.
Method HANDLE_BUFFER_RESET_ALL on class CL_REEX_PM_SERVICES has no exception.
Method RESET Signature
Method RESET on class CL_REEX_PM_SERVICES has no parameter.
Method RESET on class CL_REEX_PM_SERVICES has no exception.
History
Last changed by/on | SAP | 20100310 |
SAP Release Created in | 500 |