Hierarchy
⤷ IS-U-BI (Application Component) Contract Billing
⤷ EE20 (Package) IS-U: Billing
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_ISU_BILL_SIM_SCREEN_CONTRCT | Sim. Scenario: Simulate Contract for 1 Year (w/o Reversal) | 20040107 |
2 | Inheritance (c INHERITING FROM c_ref) | CL_ISU_BILL_SIM_SCREEN_RATECAT | Simulation Scenario: Screen for Rate Categ. Change Scenario | 20031201 |
Properties
Class | CL_ISU_BILL_SIM_SCREEN | |
Short Description | Simulation Scenario: Screen Elements | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | EE20 | IS-U: Billing |
Created | 20031201 | SAP |
Last change | 20050224 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | CL_ISU_BILL_SIM_DATA_CONTR | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) |
2 | CL_ISU_FLAG | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) |
3 | CO | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_ISU_BILL_SIM_SCREEN has no interface implemented.
Friends
Class CL_ISU_BILL_SIM_SCREEN has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ALV_CONTAINER | Instance attribute | Protected | Object reference (TYPE REF TO) | CL_GUI_DOCKING_CONTAINER | ALV Grid Control Container | 20031201 | ||
2 | ALV_DATA | Instance attribute | Protected | Type reference (TYPE) | IEASIMLINE | ALV Grid Control: Data (from Structure EASIMLINE) | 20031201 | ||
3 | ALV_GRID | Instance attribute | Protected | Object reference (TYPE REF TO) | CL_GUI_ALV_GRID | ALV List Viewer | 20031201 | ||
4 | ALV_OUTPUT_CONTAINER | Instance attribute | Protected | Type reference (TYPE) | CHAR30 | ALV Grid Control: Results Output Area | 20031201 | ||
5 | ALV_RESULT | Instance attribute | Protected | Type reference (TYPE) | IEASIMLINE | ALV Grid Control: Data (from Structure EASIMLINE) | 20031222 | ||
6 | BADI_EASIM | Instance attribute | Public | Object reference (TYPE REF TO) | IF_EX_ISU_BI_EASIM | BAdI Interface IF_EX_ISU_BI_EASIM | 20040202 | ||
7 | CL_METER_READ | Instance attribute | Public | Object reference (TYPE REF TO) | CL_ISU_ALV_EDIT_METER_READ | Simulation Workbench: Enter Period Consumption | 20031201 | ||
8 | CL_PERCONS | Instance attribute | Public | Object reference (TYPE REF TO) | CL_ISU_ALV_EDIT_PERIOD_CONS | Simulation Workbench: Enter Period Consumption | 20031201 | ||
9 | CL_SIMSCEN | Instance attribute | Public | Object reference (TYPE REF TO) | CL_ISU_BILL_SIM_SCEN | Current Simulation Scenario | 20031201 | ||
10 | CONS_ACTIVETAB | Instance attribute | Public | Type reference (TYPE) | SYUCOMM | Consumption Information: Current Tab Page | 20031202 | ||
11 | CO_ALV_FIELD_BELNR | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'BELNR' | ALV Grid Control: Field BELNR | 20031201 | |
12 | CO_ALV_FIELD_DIFFERENCE_AMOUNT | Instance attribute | Public | Type reference (TYPE) | LVC_FNAME | 'DIFFERENCE_AMOUNT' | ALV Grid Control Field: Difference | 20040203 | |
13 | CO_ALV_FIELD_LINECOLOUR | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'LINECOLOUR' | ALV Grid Control Field: LINECOLOUR | 20040205 | |
14 | CO_ALV_FIELD_PROTOCOL | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'PROTOCOL' | ALV Grid Control: Field PROTOCOL | 20031229 | |
15 | CO_ALV_FIELD_SIMLINEKEY | Instance attribute | Public | Type reference (TYPE) | LVC_FNAME | 'SIMLINEKEY' | ALV Grid Control: Field | 20031201 | |
16 | CO_ALV_FIELD_SIMLINEKEYTXT | Instance attribute | Public | Type reference (TYPE) | LVC_FNAME | 'SIMLINEKEYTXT' | ALV Grid Control: Field SIMLINEKEYTXT | 20031229 | |
17 | CO_ALV_FIELD_SIMMODE | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'SIMMODE' | ALV Grid Control: Field STATUS | 20040109 | |
18 | CO_ALV_FIELD_STATUS | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'STATUS' | ALV Grid Control: Field STATUS | 20031229 | |
19 | CO_ALV_FIELD_SUMMARY | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'SUMMARY_LINE' | ALV Grid Control: Field SUMMARY_LINE | 20031229 | |
20 | CO_ALV_STRUCTURE | Constant | Public | Type reference (TYPE) | DD02L-TABNAME | 'EASIMLINE' | ALV Grid Control: Data Structure Name | 20031201 | |
21 | CO_ASSOCIATED_MENU | Constant | Public | Type reference (TYPE) | REGEN-OKCODE | 'ALV_ASSOCIATED' | ALV Grid Control: Menu Button for Associated Contract | 20040213 | |
22 | CO_BADI_EASIM | Constant | Public | Type reference (TYPE) | EXIT_DEF | 'ISU_BI_EASIM' | BAdI EASIM | 20040203 | |
23 | CO_BUTTON_PATTERN_VERTRAG | Constant | Public | Type reference (TYPE) | LVC_FNAME | 'PATTERN_CONTRACT' | Button: Copy Contract Template | 20040108 | |
24 | CO_CHECK_CONS_TRANSFER | Constant | Public | Type reference (TYPE) | CHAR1 | 'T' | Check Distribution Factors | 20040122 | |
25 | CO_CHECK_MR_RESULT | Constant | Public | Type reference (TYPE) | CHAR1 | 'Z' | Check Meter Results | 20040122 | |
26 | CO_CHECK_PERIOD | Constant | Public | Type reference (TYPE) | CHAR1 | 'P' | Check Period Consumption | 20040122 | |
27 | CO_DISPLAY_ASSOCIATED | Constant | Public | Type reference (TYPE) | REGEN-OKCODE | 'DISP_ASS' | ALV Grid Control: Displayed Associated Contracts | 20040213 | |
28 | CO_OUTPUT_CONTAINER | Constant | Public | Type reference (TYPE) | CHAR30 | 'WORKBENCH_AUSGABE_CONTROL' | ALV Container Result | 20031201 | |
29 | CO_PROG_SIMULATION_WORKBENCH | Constant | Public | Type reference (TYPE) | PROGNAME | 'SAPLEASIM_WORKBENCH' | Simulation Workbench: Main Program | 20031222 | |
30 | CO_RCATTYPE_ALV_STRUCTURE | Constant | Public | Type reference (TYPE) | STRNAME | 'EASIMRTYPEFACT_ALV' | ALV Structure for Consumption Transfer | 20031203 | |
31 | CO_RCATTYPE_ALV_STYLE | Constant | Public | Type reference (TYPE) | STRNAME | 'CELLTAB' | ALV Structure 'Style': Consumption Transfer | 20031203 | |
32 | CO_SCREEN_RESULT_RATIO | Instance attribute | Public | Type reference (TYPE) | I | 65 | ALV Grid Control: Ratio | 20031222 | |
33 | CO_SCREEN_SIMULATION_WORKBENCH | Constant | Public | Type reference (TYPE) | SYDYNNR | '0200' | Simulation Workbench: Main Screen | 20031222 | |
34 | CO_SIMLINEKEY_DISPLAY_ALL | Constant | Public | Type reference (TYPE) | REGEN-OKCODE | 'DISP_ALL_SIMLINEKEY' | ALV Grid Control: Display all SIMLINEKEY Results | 20031222 | |
35 | CO_SIMLINEKEY_DISPLAY_SUMMARY | Constant | Public | Type reference (TYPE) | REGEN-OKCODE | 'DISP_SIMLINEKEY_SUM' | ALV Grid Control: Display Overview of Results | 20031223 | |
36 | CO_SIMLINEKEY_MENU | Constant | Public | Type reference (TYPE) | REGEN-OKCODE | 'ALV_SIMLINEKEY' | ALV Grid Control: SIMLINEKEY Menu Button | 20031222 | |
37 | CO_SIMULATION_EXECUTE | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMEXEC' | Execute Simulation | 20031201 | |
38 | CO_SIMULATION_FIRST | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMFIRST' | Execute Simulation | 20031201 | |
39 | CO_SIMULATION_INST_FACTS | Constant | Public | Type reference (TYPE) | SYUCOMM | 'COND' | Installation facts | 20040108 | |
40 | CO_SIMULATION_LAST | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMLAST' | Execute Simulation | 20031201 | |
41 | CO_SIMULATION_NEW | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMNEW' | New Simulation | 20031201 | |
42 | CO_SIMULATION_NEXT | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMNEXT' | Execute Simulation | 20031201 | |
43 | CO_SIMULATION_PATTERN_CONTRACT | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PATTERN_CONTRACT' | Execute Simulation | 20040108 | |
44 | CO_SIMULATION_PCONS_TAB1 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC1' | Consumption Information TAB 1 | 20031202 | |
45 | CO_SIMULATION_PCONS_TAB2 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC2' | Consumption Information TAB 2 | 20031202 | |
46 | CO_SIMULATION_PCONS_TAB3 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC3' | Consumption Information TAB 3 | 20031202 | |
47 | CO_SIMULATION_PCONS_TAB4 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC4' | Consumption Information TAB 4 | 20031202 | |
48 | CO_SIMULATION_PCONS_TAB5 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC5' | Consumption Information TAB 5 | 20031202 | |
49 | CO_SIMULATION_PCONS_TAB6 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC6' | Consumption Information TAB 6 | 20031202 | |
50 | CO_SIMULATION_PCONS_TAB7 | Constant | Public | Type reference (TYPE) | SYUCOMM | 'PCONS_TABSTRIP_FC7' | Consumption Information TAB 7 | 20031202 | |
51 | CO_SIMULATION_PREPARE | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMPREPARE' | Prepare Simulation | 20031201 | |
52 | CO_SIMULATION_PREV | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMPREV' | Execute Simulation | 20031201 | |
53 | CO_SIMULATION_PROTOCOL | Constant | Public | Type reference (TYPE) | SYUCOMM | 'SIMPROTOCOL' | Display Simulation Log | 20031201 | |
54 | CURFIELD | Instance attribute | Public | Type reference (TYPE) | CURFIELD | Cursor Field | 20031201 | ||
55 | ICL_CONS_TRANSFER | Instance attribute | Public | Type reference (TYPE) | IEASIMTARIFTYP_DYN | Simulation Workbench: Enter Consumption Transfer Factor | 20031201 | ||
56 | SIMSCEN | Instance attribute | Public | Type reference (TYPE) | EA_SIMSCEN | Simulation Scenario | 20040108 | ||
57 | SIMSCENCLASS | Instance attribute | Public | Type reference (TYPE) | EA_SIMSCENCLASS | Simulation Scenario Class | 20040212 | ||
58 | SIM_EXECUTED | Instance attribute | Protected | Type reference (TYPE) | KENNZX | Simulation Executed Successfully | 20031201 | ||
59 | SIM_PREPARED | Instance attribute | Protected | Type reference (TYPE) | KENNZX | Simulation Prepared | 20031201 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ACTION | Instance method | Public | Method | Simulation Object Actions | 20031201 |
2 | ACTION_FILTER_SIMLINEKEY | Instance method | Protected | Method | ALV Grid Control: Display Action Results for Each SIMLINEKEY | 20031222 |
3 | ACTION_INPUT_CHECKS | Instance method | Protected | Method | Action: Input Checks (Is it Possible to Start Simulation) | 20031201 |
4 | ACTION_INSTALLATION_FACTS | Instance method | Protected | Method | Action: Enter Installation Facts | 20040108 |
5 | ACTION_PATTERN_CONTRACT | Instance method | Protected | Method | Action: Use Contract Template from Customizing | 20040108 |
6 | ACTION_PREPARE_SIMULATION | Instance method | Protected | Method | Action: Prepare Simulation | 20031201 |
7 | ACTION_PROTOCOL | Instance method | Protected | Method | Action: Display Log for Simulation Run | 20031201 |
8 | ACTION_START_SIMULATION | Instance method | Protected | Method | Acton: Execute Simulation | 20031201 |
9 | ALV_ACTIVATE_EVENT_HANDLER | Instance method | Protected | Method | ALV Grid Control: Define Events | 20031201 |
10 | ALV_CONTAINER_SET_VISIBILITY | Instance method | Public | Method | ALV Grid Control: Display/Hide Container | 20031201 |
11 | ALV_CREATE_AND_INIT | Instance method | Protected | Method | Generate ALV Grid Control for Displaying Simulation Results | 20031201 |
12 | ALV_GET_DATA | Instance method | Public | Method | ALV Grid Control: Maintain Data Area (from Sim. Results) | 20031201 |
13 | ALV_GET_EXCLUDE_FUNCTION | Static method | Protected | Method | ALV Grid Control: Select Permissible Functions | 20031201 |
14 | ALV_GET_FIELD_CATALOG | Instance method | Protected | Method | ALV Grid Control: Define Field Attributes | 20031201 |
15 | ALV_GET_LAYOUT | Static method | Protected | Method | ALV Grid Control: Define Layout | 20031201 |
16 | ALV_HANDLE_HOTSPOT_CLICK | Instance method | Public | Event handling method | ALV Grid Control: Hotspot | 20031201 |
17 | ALV_HANDLE_MENU_BUTTON | Instance method | Public | Event handling method | ALV Grid Control: Event | 20031222 |
18 | ALV_HANDLE_TOOLBAR | Instance method | Public | Event handling method | ALV Grid Control: Event TOOLBAR | 20031222 |
19 | ALV_HANDLE_USER_COMMAND | Instance method | Public | Event handling method | ALV Grid Control: Event USER_COMMAND | 20031222 |
20 | ALV_REFRESH_DISPLAY | Instance method | Public | Method | ALV Grid Control: Refresh Data | 20031201 |
21 | ALV_VISIBLE_DIFFERENCE | Instance method | Protected | Method | Display/Hide Difference | 20040205 |
22 | CHANGE_CONSUMPTION | Static method | Public | Method | Change Consumption Information | 20040928 |
23 | CHECK_ZWSTAND | Instance method | Protected | Method | Check Validation of Entered Meter Reading | 20101004 |
24 | CLOSE | Instance method | Public | Method | Close Simulation Object | 20031201 |
25 | DEACTIVATE_INPUTS | Instance method | Protected | Method | Lock All Entry Fields | 20031215 |
26 | GET_CURFIELD | Instance method | Public | Method | Read CURFIELD | 20031201 |
27 | GET_SELECTED_RATECAT | Instance method | Public | Method | Return Selected Rate Categories | 20031201 |
28 | GET_SIMULATION_EXECUTED | Instance method | Public | Method | Was Current Simulation Executed | 20031201 |
29 | GET_SIMULATION_OBJECT | Instance method | Public | Method | Return Current Simulation Object | 20031201 |
30 | GET_SIMULATION_PREPARED | Instance method | Public | Method | Was Current Simulation Prepared? | 20031201 |
31 | GET_SIMULATION_RESULT | Instance method | Public | Method | Read Result | 20040924 |
32 | SET_CONS_TRANSFER | Instance method | Public | Method | Determine Consumption Transfer Parameters | 20031202 |
33 | SET_CONS_TRANSFER_ALV | Instance method | Public | Method | ALV Grid Control for Consumption Transfer: Create | 20031202 |
34 | SET_CONS_TRANSFER_TEXT | Instance method | Public | Method | ALV Grid Control for COnsumption Transfer: Read Texts | 20031223 |
35 | SET_CURFIELD | Instance method | Public | Method | Set CURFIELD | 20031201 |
36 | SIMULATE | Static method | Public | Method | Call/Execute Simulation | 20040928 |
Events
Class CL_ISU_BILL_SIM_SCREEN has no event.
Types
Class CL_ISU_BILL_SIM_SCREEN has no local type.
Method Signatures
Method ACTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_OKCODE | Call by reference | Type reference (TYPE) | SYUCOMM | Bildschirmbilder, Funktionscode, der PAI ausgelöst hat | 20031201 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031201 |
Method ACTION_FILTER_SIMLINEKEY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_DISPLAY_ASSOCIATED | Call by reference | Type reference (TYPE) | KENNZX | Assoziierte Verträge Einträge anzeigen | 20040213 | ||
2 | Importing | IM_DISPLAY_SUMMARY | Call by reference | Type reference (TYPE) | KENNZX | Übersicht Einträge anzeigen | 20031223 | ||
3 | Importing | IM_REFRESH | Call by reference | Type reference (TYPE) | KENNZX | 'X' | ALV aktualisieren | 20031223 | |
4 | Importing | IM_SIMLINEKEY | Call by reference | Type reference (TYPE) | EA_SIMLINEKEY | Schlüsselmerkmal für Ergebniszeilen d. Abrechnungssimulation | 20031222 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031222 |
Method ACTION_INPUT_CHECKS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_CHECK_OBJECT | Call by reference | Type reference (TYPE) | CHAR1 | Objekt zu prüfen | 20040122 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031201 | |
2 | USER_ERROR | User fehler | 20031201 |
Method ACTION_INSTALLATION_FACTS Signature
Method ACTION_INSTALLATION_FACTS on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine Fehler | 20040108 |
Method ACTION_PATTERN_CONTRACT Signature
Method ACTION_PATTERN_CONTRACT on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine Fehler | 20040108 |
Method ACTION_PREPARE_SIMULATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_MESSAGE | Call by reference | Type reference (TYPE) | KENNZX | Erfolgsmeldung schreiben? | 20031201 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031201 |
Method ACTION_PROTOCOL Signature
Method ACTION_PROTOCOL on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031201 |
Method ACTION_START_SIMULATION Signature
Method ACTION_START_SIMULATION on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031201 | |
2 | USER_ERROR | Eingabefehler | 20031201 |
Method ALV_ACTIVATE_EVENT_HANDLER Signature
Method ALV_ACTIVATE_EVENT_HANDLER on class CL_ISU_BILL_SIM_SCREEN has no parameter.
Method ALV_ACTIVATE_EVENT_HANDLER on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_CONTAINER_SET_VISIBILITY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_VISIBLE | Call by reference | Type reference (TYPE) | KENNZX | Kennzeichen | 20031201 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine Fehler | 20031201 |
Method ALV_CREATE_AND_INIT Signature
Method ALV_CREATE_AND_INIT on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ALREADY_EXISTS | ALV schon vorhanden | 20031201 | |
2 | SYSTEM_ERROR | System fehler | 20031201 |
Method ALV_GET_DATA Signature
Method ALV_GET_DATA on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeiner Fehler | 20031201 |
Method ALV_GET_EXCLUDE_FUNCTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EXT_EXCLUDING | Call by reference | Type reference (TYPE) | UI_FUNCTIONS | Funktionscodestabelle | 20031201 |
Method ALV_GET_EXCLUDE_FUNCTION on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_GET_FIELD_CATALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EXT_FIELD_CATALOG | Call by reference | Type reference (TYPE) | LVC_T_FCAT | Feldkatalog für ListViewerControl | 20031201 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | SYSTEM_ERROR | System Error | 20031201 |
Method ALV_GET_LAYOUT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EX_LAYOUT | Call by reference | Type reference (TYPE) | LVC_S_LAYO | ALV-Control: Layoutstruktur | 20031201 |
Method ALV_GET_LAYOUT on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_HANDLE_HOTSPOT_CLICK Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | ES_ROW_NO | Call by reference | Attribute reference (LIKE) | 20031201 | ||||
2 | Importing | E_COLUMN_ID | Call by reference | Attribute reference (LIKE) | 20031201 | ||||
3 | Importing | E_ROW_ID | Call by reference | Attribute reference (LIKE) | 20031201 |
Method ALV_HANDLE_HOTSPOT_CLICK on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_HANDLE_MENU_BUTTON Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | E_OBJECT | Call by reference | Attribute reference (LIKE) | 20031222 | ||||
2 | Importing | E_UCOMM | Call by reference | Attribute reference (LIKE) | 20031222 |
Method ALV_HANDLE_MENU_BUTTON on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_HANDLE_TOOLBAR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | E_INTERACTIVE | Call by reference | Attribute reference (LIKE) | 20031222 | ||||
2 | Importing | E_OBJECT | Call by reference | Attribute reference (LIKE) | 20031222 |
Method ALV_HANDLE_TOOLBAR on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_HANDLE_USER_COMMAND Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | E_UCOMM | Call by reference | Attribute reference (LIKE) | 20031222 |
Method ALV_HANDLE_USER_COMMAND on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method ALV_REFRESH_DISPLAY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_GET_DATA | Call by reference | Type reference (TYPE) | KENNZX | Flag; ALV Daten sollen gelesen werden | 20031201 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | SYSTEM_ERROR | System fehler | 20031201 |
Method ALV_VISIBLE_DIFFERENCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_VISIBLE | Call by reference | Type reference (TYPE) | KENNZX | Differenzbetrag sichtbar/unsichtbar schalten | 20040205 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20040205 |
Method CHANGE_CONSUMPTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IMT_EASIMPERCONS | Call by reference | Type reference (TYPE) | IEASIMPERCONS | Periodenverbrauch zur Abrechnungssimulation | 20040928 | ||
2 | Importing | IM_SIMSCREEN_OBJECT | Call by reference | Object reference (TYPE REF TO) | CL_ISU_BILL_SIM_SCREEN | Simulationsszenario: Dynproelemente | 20040928 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20040928 |
Method CHECK_ZWSTAND Signature
Method CHECK_ZWSTAND on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeiner Fehler | 20101004 |
Method CLOSE Signature
Method CLOSE on class CL_ISU_BILL_SIM_SCREEN has no parameter.
Method CLOSE on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method DEACTIVATE_INPUTS Signature
Method DEACTIVATE_INPUTS on class CL_ISU_BILL_SIM_SCREEN has no parameter.
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031215 |
Method GET_CURFIELD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RET_CURFIELD | Value transfer | Type reference (TYPE) | CURFIELD | 20031201 |
Method GET_CURFIELD on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method GET_SELECTED_RATECAT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RET_RATECAT_SELECTED | Value transfer | Type reference (TYPE) | ITARIFTYP | Tabelle von Tariftypen | 20031201 |
Method GET_SELECTED_RATECAT on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method GET_SIMULATION_EXECUTED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RET_SIMULATION_EXECUTED | Value transfer | Type reference (TYPE) | KENNZX | Simulation ausgeführt | 20031201 |
Method GET_SIMULATION_EXECUTED on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method GET_SIMULATION_OBJECT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RET_SIMULATION_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_ISU_BILL_SIM_SCEN | Simulationsszenario | 20031201 |
Method GET_SIMULATION_OBJECT on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method GET_SIMULATION_PREPARED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RET_SIMULATION_PREPARED | Value transfer | Type reference (TYPE) | KENNZX | Simulation vorbereitet | 20031201 |
Method GET_SIMULATION_PREPARED on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method GET_SIMULATION_RESULT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EXT_IEASIMLINE | Call by reference | Type reference (TYPE) | IEASIMLINE | Tbellentyp zu EASIMLINE | 20040924 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | NO_RESULTS_AVAILABLE | Es sind keine Ergebnisse vorhanden | 20040924 |
Method SET_CONS_TRANSFER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EX_NUM_CONS_TRANSFER | Call by reference | Type reference (TYPE) | I | Anzahl Verbrauchsübernahme Objekte | 20031204 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031202 |
Method SET_CONS_TRANSFER_ALV Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_CONTAINER_NAME | Call by reference | Type reference (TYPE) | CHAR30 | ALV Custom Container | 20031203 | ||
2 | Importing | IM_SCREEN | Call by reference | Type reference (TYPE) | I | Dynpronummer | 20031202 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20031202 | |
2 | NOT_FOUND | Es wurde keine passende Verbrauchsübernahme-Information gef. | 20031203 |
Method SET_CONS_TRANSFER_TEXT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EX_TEXT | Call by reference | Type reference (TYPE) | CHAR25 | Text zum Tab-Reiter | 20031223 | ||
2 | Importing | IM_SCREEN | Call by reference | Type reference (TYPE) | I | Dynpronummer | 20031223 |
Method SET_CONS_TRANSFER_TEXT on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method SET_CURFIELD Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_CURFIELD | Call by reference | Type reference (TYPE) | CURFIELD | 20031201 |
Method SET_CURFIELD on class CL_ISU_BILL_SIM_SCREEN has no exception.
Method SIMULATE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EXT_IEASIMLINE | Call by reference | Type reference (TYPE) | IEASIMLINE | Tbellentyp zu EASIMLINE | 20040928 | ||
2 | Importing | IM_EXECUTE_SIMULATION | Call by reference | Type reference (TYPE) | KENNZX | Simulation soll ausgeführt werden | 20040928 | ||
3 | Importing | IM_NO_DIALOG | Call by reference | Type reference (TYPE) | REGEN-NO_DIALOG | Pflegebilder unterdrücken | 20040928 | ||
4 | Importing | IM_PREPARE_SIMULATION | Call by reference | Type reference (TYPE) | KENNZX | Simulation soll vorbereitet werden | 20040928 | ||
5 | Importing | IM_SIMSCEN | Call by reference | Type reference (TYPE) | EA_SIMSCEN | Simulationsszenario | 20040928 | ||
6 | Importing | IM_SIMSCREEN_OBJECT | Call by reference | Object reference (TYPE REF TO) | CL_ISU_BILL_SIM_SCREEN | Simulationsszenario: Dynproelemente | 20040928 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | GENERAL_FAULT | Allgemeine fehler | 20040928 | |
2 | NO_RESULTS_AVAILABLE | Es sind keine Simulationsergebnisse erzeugt worden | 20040928 |
History
Last changed by/on | SAP | 20050224 |
SAP Release Created in | 472 |