SAP ABAP Class CL_FDT_GTC_SFW (BRFplus unit tests for Switch Framework (SFW))
Hierarchy
SAP_BASIS (Software Component) SAP Basis Component
   BC-SRV-BR (Application Component) BRFplus - ABAP-Based Business Rules
     SFDT_TEST (Package) BRFplus: Global Test Classes
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_FDT_UNITTEST_HELPERS Toolset for global unit tests 20111207
Properties
Class CL_FDT_GTC_SFW  
Short Description BRFplus unit tests for Switch Framework (SFW)    
Super Class CL_FDT_UNITTEST_HELPERS Toolset for global unit tests 
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status T  Test Program 
Category 5   
Package SFDT_TEST   BRFplus: Global Test Classes 
Created 20111207   SAP 
Last change 20130531   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 CL_FDT_DEPLOYMENT Forward declaration class (CLASS c DEFINITION DEFERRED)  Forward declaration class (CLASS c DEFINITION DEFERRED)
3 CL_FDT_SFW Forward declaration class (CLASS c DEFINITION DEFERRED)  Forward declaration class (CLASS c DEFINITION DEFERRED)
4 IF_FDT_TYPES Forward declaration interface (INTERFACE i DEFINITION DEF...  Forward declaration interface (INTERFACE i DEFINITION DEF...
Interfaces
Class CL_FDT_GTC_SFW has no interface implemented.
Friends
Class CL_FDT_GTC_SFW has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 GC_NAME_ELEM1_GENDER Constant Protected Type reference (TYPE) IF_FDT_TYPES=>NAME 'GENDER' Beschreibung 20111207
2 GC_NAME_ELEM2_AGE Constant Protected Type reference (TYPE) IF_FDT_TYPES=>NAME 'AGE' Beschreibung 20111207
3 GC_NAME_ELEM3_RISK Constant Protected Type reference (TYPE) IF_FDT_TYPES=>NAME 'RISK' Beschreibung 20111207
4 GC_NAME_FUNCTION Constant Protected Type reference (TYPE) IF_FDT_TYPES=>NAME 'DEPLOYMENT_FUNCTION' Beschreibung 20111207
5 GC_SWITCH_ID_DUMMY Constant Public Type reference (TYPE) CL_FDT_SFW=>S_SWITCH_INFO-ID 'FDT_DUMMY' Dummy Switch 20111208
6 GC_SWITCH_ID_OFF Constant Public Type reference (TYPE) CL_FDT_SFW=>S_SWITCH_INFO-ID 'FDT_TEST_SWITCH_OFF' Inactive Switch 20111207
7 GC_SWITCH_ID_ON Constant Public Type reference (TYPE) CL_FDT_SFW=>S_SWITCH_INFO-ID 'FDT_TEST_SWITCH_ON' Active Switch 20111207
8 MO_FACTORY Instance attribute Private Object reference (TYPE REF TO) IF_FDT_FACTORY FDT: Factory 20111207
9 MV_ELEM2_AGE_ID Instance attribute Private Type reference (TYPE) IF_FDT_TYPES=>ID Universal Unique Identifier 20111207
Methods
# Method Level Visibility Method type Description Created on
1 ENQUEUE Static method Protected Method Enqueue passed object 20111207
2 HANDLE_UNCAUGHT_EXCEPTION Static method Private Method Handle CX_FDT exception that were not caught elsewhere 20111207
3 INIT Instance method Protected Method Check environment 20111207
4 MFT_SFW_0001 Instance method Protected Test Method for ABAP Unit Check class CL_FDT_SFW_SERVICES 20111207
5 MFT_SFW_0002 Instance method Protected Test Method for ABAP Unit Check class CL_FDT_SFW 20111208
6 MFT_SFW_0003 Instance method Protected Test Method for ABAP Unit Check class CL_FDT_DDIC_SERVICES for switch information 20111208
Events
Class CL_FDT_GTC_SFW has no event.
Types
Class CL_FDT_GTC_SFW has no local type.
Method Signatures

Method ENQUEUE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_OBJECT Call by reference Object reference (TYPE REF TO) IF_FDT_TRANSACTION FDT: Transaction 20111207
# Exception Resumable Description Created on
1 CX_FDT FDT: Abstract Exception Class 20111207

Method HANDLE_UNCAUGHT_EXCEPTION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IX_FDT Call by reference Object reference (TYPE REF TO) CX_FDT FDT: Abstract Exception Class 20111207

Method HANDLE_UNCAUGHT_EXCEPTION on class CL_FDT_GTC_SFW has no exception.

Method INIT Signature

Method INIT on class CL_FDT_GTC_SFW has no parameter.
Method INIT on class CL_FDT_GTC_SFW has no exception.

Method MFT_SFW_0001 Signature

Method MFT_SFW_0001 on class CL_FDT_GTC_SFW has no parameter.
Method MFT_SFW_0001 on class CL_FDT_GTC_SFW has no exception.

Method MFT_SFW_0002 Signature

Method MFT_SFW_0002 on class CL_FDT_GTC_SFW has no parameter.
Method MFT_SFW_0002 on class CL_FDT_GTC_SFW has no exception.

Method MFT_SFW_0003 Signature

Method MFT_SFW_0003 on class CL_FDT_GTC_SFW has no parameter.
Method MFT_SFW_0003 on class CL_FDT_GTC_SFW has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in 732