SAP ABAP Class CL_DBA_GUI_DATA_RANGE (DBA Cockpit: Visualization of Range Selection)
Hierarchy
☛
SAP_BASIS (Software Component) SAP Basis Component
⤷
BC-DB (Application Component) Database Interface, Database Platforms
⤷
SDBA_RUNTIME (Package) DBA Cockpit: Runtime

⤷

⤷

Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_DBA_GUI_SELECTOR | DBA Cockpit: Visualization of Selection Lists | 20050513 |
Properties
Class | CL_DBA_GUI_DATA_RANGE | |
Short Description | DBA Cockpit: Visualization of Range Selection | |
Super Class | CL_DBA_GUI_SELECTOR | DBA Cockpit: Visualization of Selection Lists |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | SDBA_RUNTIME | DBA Cockpit: Runtime |
Created | 20050513 | SAP |
Last change | 20130531 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_DBA_GUI_DATA_RANGE has no interface implemented.
Friends
Class CL_DBA_GUI_DATA_RANGE has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Instance attribute | Private | Type reference (TYPE) | ABAP_BOOL | 20051027 | |||
2 | ![]() |
Instance attribute | Private | Type reference (TYPE) | ABAP_BOOL | 20051027 | |||
3 | ![]() |
Constant | Public | Type reference (TYPE) | I | 1 | 20050517 | ||
4 | ![]() |
Constant | Public | Type reference (TYPE) | I | 2 | 20050517 | ||
5 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_DB6_ACTION_CONTROLLER_RANGE | DBA Cockpit: Interface to Actions with Data Preselection | 20080110 | ||
6 | ![]() |
Instance attribute | Private | Type reference (TYPE) | I | 20050517 | |||
7 | ![]() |
Instance attribute | Private | Type reference (TYPE) | DBA_XREF_RANGE_MENU | DBA Cockpit: Range Menu | 20050518 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Private | Method | 20051027 | |
2 | ![]() |
Instance method | Private | Method | 20050517 | |
3 | ![]() |
Instance method | Private | Method | 20050517 | |
4 | ![]() |
Instance method | Private | Method | 20051027 | |
5 | ![]() |
Instance method | Public | Constructor | CONSTRUCTOR | 20050517 |
6 | ![]() |
Instance method | Public | Method | 20080110 |
Events
Class CL_DBA_GUI_DATA_RANGE has no event.
Types
Class CL_DBA_GUI_DATA_RANGE has no local type.
Method Signatures
Method ADD_2ND_LEVEL_MENU Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RANGETYPE | Call by reference | Type reference (TYPE) | I | 20051027 | |||
2 | ![]() |
RANGE_CONTROLLER_REF | Call by reference | Object reference (TYPE REF TO) | IF_DB6_ACTION_CONTROLLER_RANGE | DBA Cockpit: Interface to Actions with Data Preselection | 20080110 | ||
3 | ![]() |
SELECTED_NODE | Call by reference | Type reference (TYPE) | TV_NODEKEY | Function code | 20051027 | ||
4 | ![]() |
TEXT | Call by reference | Type reference (TYPE) | STRING | 20051027 |
Method ADD_2ND_LEVEL_MENU on class CL_DBA_GUI_DATA_RANGE has no exception.
Method ADD_2ND_LEVEL_NODE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ID | Call by reference | Type reference (TYPE) | STRING | 20051027 | |||
2 | ![]() |
PARENT | Call by reference | Type reference (TYPE) | STRING | 20050518 | |||
3 | ![]() |
TEXT | Call by reference | Type reference (TYPE) | STRING | 20050517 |
Method ADD_2ND_LEVEL_NODE on class CL_DBA_GUI_DATA_RANGE has no exception.
Method ADD_LEAF Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ID | Call by reference | Type reference (TYPE) | I | 20050518 | |||
2 | ![]() |
PARENT | Call by reference | Type reference (TYPE) | STRING | 20050518 | |||
3 | ![]() |
TEXT | Call by reference | Type reference (TYPE) | STRING | 20050518 |
Method ADD_LEAF on class CL_DBA_GUI_DATA_RANGE has no exception.
Method ADD_LOW_LEVEL_MENU Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RANGETYPE | Call by reference | Type reference (TYPE) | I | 20051027 | |||
2 | ![]() |
RANGE_CONTROLLER_REF | Call by reference | Object reference (TYPE REF TO) | IF_DB6_ACTION_CONTROLLER_RANGE | DBA Cockpit: Interface to Actions with Data Preselection | 20080110 | ||
3 | ![]() |
SELECTED_NODE | Call by reference | Type reference (TYPE) | TV_NODEKEY | Function code | 20051027 | ||
4 | ![]() |
TEXT | Call by reference | Type reference (TYPE) | STRING | 20051027 |
Method ADD_LOW_LEVEL_MENU on class CL_DBA_GUI_DATA_RANGE has no exception.
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CONTAINER | Call by reference | Object reference (TYPE REF TO) | CL_GUI_CONTAINER | Behälter für Custom Controls im Bildbereich | 20050517 | ||
2 | ![]() |
DYNPRO_FIELD | Call by reference | Type reference (TYPE) | CLIKE | 20050517 | |||
3 | ![]() |
FLIP_VIEW | Call by reference | Type reference (TYPE) | ABAP_BOOL | 20050530 | |||
4 | ![]() |
NAV_REF | Call by reference | Object reference (TYPE REF TO) | CL_DB6_TREE_NAVIGATOR | CL_DB6_TREE_NAVIGATOR | 20050524 | ||
5 | ![]() |
RANGE_TYPE | Call by reference | Type reference (TYPE) | I | 20050517 | |||
6 | ![]() |
TITLE | Call by reference | Type reference (TYPE) | CLIKE | 20050517 | |||
7 | ![]() |
VIEW_TYPE | Call by reference | Type reference (TYPE) | I | 20050517 |
Method CONSTRUCTOR on class CL_DBA_GUI_DATA_RANGE has no exception.
Method SET_RANGE_CONTROLLER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RANGE_CONTROLLER_REF | Call by reference | Object reference (TYPE REF TO) | IF_DB6_ACTION_CONTROLLER_RANGE | DBA Cockpit: Interface to Actions with Data Preselection | 20080110 |
Method SET_RANGE_CONTROLLER on class CL_DBA_GUI_DATA_RANGE has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in | 710 |