Where Used List (Function Module) for SAP ABAP Table FRMLS_HDR_ALL (RMS-FRM: Formula Header Data (Complete))
SAP ABAP Table
FRMLS_HDR_ALL (RMS-FRM: Formula Header Data (Complete)) is used by
| # | Object Type | Object Name | Object Description | Package | Structure Package | Software Component |
|---|---|---|---|---|---|---|
| 1 |
BAPI_FORMULA_GETDETAILMULTIPLE
|
Reading Formulas | ||||
| 2 |
FRML143_EXIT_STD_LORS
|
RMS-FRM: Exitbaustein Standardisierung für Substanzen | ||||
| 3 |
FRML172_CALC_ADD REFERENCE(IS_HDR_ALL) TYPE FRMLS_HDR_ALL OPTIONAL
|
RMS-FRM: Berechnen der ADD-Daten | ||||
| 4 |
FRML172_CALC_ADD_FROM_API REFERENCE(IS_HDR_ALL) TYPE FRMLS_HDR_ALL OPTIONAL
|
RMS-FRM: Füllen der Zusatzdaten | ||||
| 5 |
FRML172_CALC_ADD_FROM_API
|
RMS-FRM: Füllen der Zusatzdaten | ||||
| 6 |
FRML172_CALC_ADD_SUM_ADAPT REFERENCE(IS_HDR_ALL) TYPE FRMLS_HDR_ALL OPTIONAL
|
RMS-FRM: Berechnen der ADD-Daten + angepasste Summen Logik | ||||
| 7 |
FRML172_HD_FILL_API_FROM_IOTAB
|
RMS-FRM: Füllen der API-Strukturen mit Dialogdaten | ||||
| 8 |
FRML172_HD_FILL_IOTAB_FROM_API
|
RMS-FRM: Füllen der Dialog-Strukturen mit API-Daten | ||||
| 9 |
FRML172_PO_FROM_INPUT_CALC REFERENCE(IS_HDR_ALL) TYPE FRMLS_HDR_ALL OPTIONAL
|
Berechnung der Primärausbeute aus den Einsätzen | ||||
| 10 |
FRML174_CHECK_ADAPT_HEADER REFERENCE(IS_HDR_OLD) TYPE FRMLS_HDR_ALL
|
Formelkopf Felder prüfen und anpassen | ||||
| 11 |
FRML174_CHECK_ADAPT_HEADER
|
Formelkopf Felder prüfen und anpassen | ||||
| 12 |
FRML174_CHECK_ADAPT_HEADER REFERENCE(XS_HDR_NEW) TYPE FRMLS_HDR_ALL
|
Formelkopf Felder prüfen und anpassen | ||||
| 13 |
FRML174_CHECK_ADAPT_ITEM
|
Formel Positions Felder prüfen und anpassen | ||||
| 14 |
FRML174_CHECK_ADAPT_ITEM REFERENCE(IS_HDR) TYPE FRMLS_HDR_ALL
|
Formel Positions Felder prüfen und anpassen | ||||
| 15 |
FRML174_FILL_API_FROM_SCR
|
RMS-FRM: Überträgt Screendaten in Pflege-API | ||||
| 16 |
FRML174_FILL_API_FROM_SCR REFERENCE(ES_HDR_ALL) TYPE FRMLS_HDR_ALL
|
RMS-FRM: Überträgt Screendaten in Pflege-API | ||||
| 17 |
FRML174_FILL_SCR_FROM_API REFERENCE(XS_HDR_ALL) TYPE FRMLS_HDR_ALL OPTIONAL
|
RMS-FRM: Screenstruktur über Lese-API füllen | ||||
| 18 |
FRML174_FILL_SCR_FROM_API
|
RMS-FRM: Screenstruktur über Lese-API füllen | ||||
| 19 |
FRML174_IOTAB_FROM_API_GET
|
RMS-FRM: füllt Dialogstruktur über Lese-API | ||||
| 20 |
FRML174_READ_HDR REFERENCE(ES_HDR_DATA_ALL) TYPE FRMLS_HDR_ALL
|
Lesen der Formelkopfdaten durch direkten Zugriff auf das API | ||||
| 21 |
FRML174_READ_HDR
|
Lesen der Formelkopfdaten durch direkten Zugriff auf das API | ||||
| 22 |
FRML174_READ_PROPERTIES REFERENCE(I_HDR_ALL) TYPE FRMLS_HDR_ALL
|
Lesen von Eigenschaften der Formelpositionen | ||||
| 23 |
FRML174_READ_PROPERTIES
|
Lesen von Eigenschaften der Formelpositionen | ||||
| 24 |
FRML174_RECALCULATE_FORMULA
|
Neuberechnung einer Formel mit API Update | ||||
| 25 |
FRML174_WRITE_HDR REFERENCE(ES_HDR_DATA) TYPE FRMLS_HDR_ALL
|
Schreiben/Verändern der Formelkopfdaten durch direkten Zugrif auf das API | ||||
| 26 |
FRML174_WRITE_HDR
|
Schreiben/Verändern der Formelkopfdaten durch direkten Zugrif auf das API | ||||
| 27 |
FRML174_WRITE_HDR REFERENCE(IS_HDR_DATA) TYPE FRMLS_HDR_ALL
|
Schreiben/Verändern der Formelkopfdaten durch direkten Zugrif auf das API | ||||
| 28 |
FRML175_KEY_FIGURES_READ
|
Lesen / Berechnen von Key Figures (Massenfähig) | ||||
| 29 |
FRML180_CONSISTENCY_CHECK
|
RMS_FRM: Konsistenzcheck | ||||
| 30 |
FRML180_CONS_FLG_MANUALLY_SET
|
RMS-FRM: Konsistenz-Flag wurde manuell gesetzt | ||||
| 31 |
FRML180_USEREXIT_CONS_CHECK
|
RMS-FRM: Userexit für Konsistenzprüfung | ||||
| 32 |
FRML180_VIEW_IS_CHANGED
|
RMS-FRM: Formelsicht wurde geändert | ||||
| 33 |
FRML180_VIEW_IS_GENERATE
|
RMS-FRM: Formelsicht wird aus anderer generiert | ||||
| 34 |
FRML209_CHECK_SYNCHRONIZABLE
|
Prüfen, ob Rezept synchronisierbar ist | ||||
| 35 |
FRML209_RCP_SYNC_NEW REFERENCE(XS_HDR_REC) TYPE FRMLS_HDR_ALL OPTIONAL
|
RMS-RMS: Rezeptformel synchronisieren | ||||
| 36 |
FRML209_SYNCHRONIZE
|
Rezeptformel synchronisieren | ||||
| 37 |
FRML209_SYNCHRONIZE REFERENCE(ES_HDR_RCPFRML) TYPE FRMLS_HDR_ALL
|
Rezeptformel synchronisieren | ||||
| 38 |
FRML515_LAYOUT_INIT
|
RMS-FRM: Initialisierung des LayoutScreens | ||||
| 39 |
FRML515_OKCODE_HANDLER
|
RMS-FRM: OK-Code Handling Layout-Screen | ||||
| 40 |
FRML515_UPDATE VALUE(IS_HDR_ALL) TYPE FRMLS_HDR_ALL
|
RMS-FRM: Flags aktualisieren | ||||
| 41 |
FRML515_UPDATE
|
RMS-FRM: Flags aktualisieren | ||||
| 42 |
FRML528_POPUP_UPDATE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL OPTIONAL
|
RMS-FRM: Summary-Popup aktualisieren | ||||
| 43 |
FRML528_POPUP_UPDATE
|
RMS-FRM: Summary-Popup aktualisieren | ||||
| 44 |
FRML529_OKCODE_HANDLER
|
Subscreen: OK Code Summary Tab | ||||
| 45 |
FRML529_TABSCREEN_CLOSE
|
Subscreen: Verlassen (Kopiervorlage) | ||||
| 46 |
FRML529_TABSCREEN_OPEN
|
Subscreen: Öffnen (Kopiervorlage) | ||||
| 47 |
FRML530_HEAD_OBJECTNAME_BUILD
|
RMS-FRM: Für eine Steploop-Zeile einen Objektnamen generieren | ||||
| 48 |
FRML530_HEAD_OBJECTNAME_BUILD VALUE(I_IOREC) LIKE FRMLS_HDR_ALL
|
RMS-FRM: Für eine Steploop-Zeile einen Objektnamen generieren | ||||
| 49 |
FRML530_TABSCREEN_CLOSE
|
RMS-FRM: Nachverarbeitung Tabstrip Subscreen | ||||
| 50 |
FRML530_TABSCREEN_OPEN
|
RMS-FRM: Vorverarbeitung Tabstrip Subscreen | ||||
| 51 |
FRML531_TABSCREEN_CLOSE
|
RMS-FRM: Nachverarbeitung Tabstrip Subscreen | ||||
| 52 |
FRML532_TABSCREEN_CLOSE
|
RMS-FRM: Nachverarbeitung Tabstrip Subscreen | ||||
| 53 |
FRML534_CALC_RECONSTITUTION
|
RMS-FRM: Berechnung der Reconstitution Rate | ||||
| 54 |
FRML534_CALL_CONVERSION
|
RMS-FRM: Umrechnungsfunktionen | ||||
| 55 |
FRML537_TABSCREEN_OPEN
|
Formelsicht: Öffnen der Sicht (Kopiervorlage) | ||||
| 56 |
FRML538A_CONS_CHECK_DELETE
|
Check consistency and delete Nutrients to formula | ||||
| 57 |
FRML538A_CONS_CHECK_DELETE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and delete Nutrients to formula | ||||
| 58 |
FRML538A_CONS_CHECK_WRITE
|
Check consistency and write Nutrients to formula | ||||
| 59 |
FRML538A_CONS_CHECK_WRITE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and write Nutrients to formula | ||||
| 60 |
FRML538_TABSCREEN_OPEN
|
Formelsicht: Öffnen der Sicht (Kopiervorlage) | ||||
| 61 |
FRML539A_CONS_CHECK_DELETE
|
Check consistency and delete Nutrients to formula | ||||
| 62 |
FRML539A_CONS_CHECK_DELETE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and delete Nutrients to formula | ||||
| 63 |
FRML539A_CONS_CHECK_WRITE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and write Nutrients to formula | ||||
| 64 |
FRML539A_CONS_CHECK_WRITE
|
Check consistency and write Nutrients to formula | ||||
| 65 |
FRML539_CALL_CONVERSION
|
RMS-FRM: Umrechnungsfunktionen | ||||
| 66 |
FRML539_TABSCREEN_OPEN
|
Subscreen: Öffnen (Kopiervorlage) | ||||
| 67 |
FRML540A_CONS_CHECK_DELETE
|
Check consistency and delete Nutrients to formula | ||||
| 68 |
FRML540A_CONS_CHECK_DELETE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and delete Nutrients to formula | ||||
| 69 |
FRML540A_CONS_CHECK_WRITE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and write Nutrients to formula | ||||
| 70 |
FRML540A_CONS_CHECK_WRITE
|
Check consistency and write Nutrients to formula | ||||
| 71 |
FRML540_CALL_CONVERSION
|
RMS-FRM: Umrechnungsfunktionen | ||||
| 72 |
FRML540_TABSCREEN_OPEN
|
Subscreen: Öffnen (Kopiervorlage) | ||||
| 73 |
FRML542_TABSCREEN_OPEN
|
Subscreen: Öffnen | ||||
| 74 |
FRML544_TABSCREEN_OPEN
|
RMS-FRM: Sicht Öffnen | ||||
| 75 |
FRML545_FCAT_ADJUST
|
Gen.I/O: Feldkatalog an Layouteinstellung anpassen | ||||
| 76 |
FRML545_TABSCREEN_CLOSE
|
Gen.I/O: Verlassen der Sicht | ||||
| 77 |
FRML545_TABSCREEN_OPEN
|
Gen.I/O: Öffnen der Sicht | ||||
| 78 |
FRML546_CALL_CONVERSION
|
I/O: Umrechnungsfunktionen | ||||
| 79 |
FRML546_CONS_UNSET_AND_RECALC
|
Neuberechnung nachfolgender Stufenformeln und Entfernen d. Konsistenzflags | ||||
| 80 |
FRML546_CONS_UNSET_AND_RECALC REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Neuberechnung nachfolgender Stufenformeln und Entfernen d. Konsistenzflags | ||||
| 81 |
FRML556_TABSCREEN_CLOSE
|
Key Figures: Verlassen der Sicht | ||||
| 82 |
FRML556_TABSCREEN_OPEN
|
Key Figures: Öffnen der Sicht | ||||
| 83 |
FRML558A_CONS_CHECK_DELETE
|
Check consistency and delete Diets to formula | ||||
| 84 |
FRML558A_CONS_CHECK_DELETE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and delete Diets to formula | ||||
| 85 |
FRML558A_CONS_CHECK_WRITE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL
|
Check consistency and write Diets to formula | ||||
| 86 |
FRML558A_CONS_CHECK_WRITE
|
Check consistency and write Diets to formula | ||||
| 87 |
FRML558_TABSCREEN_OPEN
|
Diets Sum: Öffnen der Sicht | ||||
| 88 |
FRML559_SCALE_UP_DOWN
|
RM22. Scale UP/DOWN | ||||
| 89 |
FRML560_TABSCREEN_CLOSE
|
LoM I/O: Verlassen der Sicht | ||||
| 90 |
FRML560_TABSCREEN_OPEN
|
LoM I/O: Öffnen der Sicht | ||||
| 91 |
FRML562_CHECK_UNIT
|
RMS-FRM: Überprüfen, ob die Mengeneinheit erlaubt ist | ||||
| 92 |
FRML565_CHECK_ENABLE_SCREEN
|
RMS-FRM:Ermittlung der Sichtbarkeit | ||||
| 93 |
FRML565_CHECK_LOSS_UPDATE REFERENCE(IS_HDR_ALL) TYPE FRMLS_HDR_ALL
|
Prüft, ob ein Verlust an Verdunstungsformel existiert | ||||
| 94 |
FRML565_CHECK_LOSS_UPDATE
|
Prüft, ob ein Verlust an Verdunstungsformel existiert | ||||
| 95 |
FRML565_CHECK_SCREEN_MODE
|
Formula View: Exitmodule for nutrients screen: Write Data to EH&S | ||||
| 96 |
FRML565_CHECK_SCREEN_MODE REFERENCE(IS_FRML_HDR) TYPE FRMLS_HDR_ALL OPTIONAL
|
Formula View: Exitmodule for nutrients screen: Write Data to EH&S | ||||
| 97 |
FRML565_INSERT_VIA_DRAG_DROP
|
RMS-FRM: Anlegen Positionen via drag&drop | ||||
| 98 |
FRML566_TABSCREEN_CLOSE
|
LoRS I/O: Verlassen der Sicht | ||||
| 99 |
FRML566_TABSCREEN_OPEN
|
LoRS I/O: Öffnen der Sicht | ||||
| 100 |
FRML600_OKCODE_HANDLER
|
Sicht OK Code Handling | ||||
| 101 |
FRML600_TABSCREEN_CLOSE
|
Sicht Verlassen | ||||
| 102 |
FRML600_TABSCREEN_OPEN
|
Sicht Öffnen | ||||
| 103 |
FRML781_LOM_CREATE_FROM_BOM_2
|
RMS_FRM: Interface BOM - LOM | ||||
| 104 |
FRML983_PROPDATA_WRITE REFERENCE(IS_HDR) TYPE FRMLS_HDR_ALL OPTIONAL
|
RM22: Schreibt Merkmalswerte vom PO/Formel ins EHS | ||||
| 105 |
FRML983_PROPDATA_WRITE
|
RM22: Schreibt Merkmalswerte vom PO/Formel ins EHS | ||||
| 106 |
RMXT752_GET_RCP_FRML2
|
TMS-DIA: Datenbeschaffung aus Recipe- / Formula API |